Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Hyperthermia ; 36(1): 554-561, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31132888

RESUMEN

Purpose: This study aimed to evaluate the effects of various computed tomography (CT) acquisition parameters and metal artifacts on CT number measurement for CT thermometry during CT-guided thermal ablation. Methods: The effects of tube voltage (100-140 kVp), tube current (20-250 mAs), pitch (0.6-1.5) and gantry rotation time (0.5, 1.0 s) as well as metal artifacts from a radiofrequency ablation (RFA) needle on CT number were evaluated using liver tissue equivalent polyacrylamide (PAA) phantom. The correlation between CT number and temperature from 37 to 80 °C was studied on PAA phantom using optimum CT acquisition parameters. Results: No statistical significant difference (p > 0.05) was found on CT numbers under the variation of different acquisition parameters for the same temperature setting. On the other hand, the RFA needle has induced metal artifacts on the CT images of up to 8 mm. The CT numbers decreased linearly when the phantom temperature increased from 37 to 80 °C. A linear regression analysis on the CT numbers and temperature suggested that the CT thermal sensitivity was -0.521 ± 0.061 HU/°C (R2 = 0.998). Conclusion: CT thermometry is feasible for temperature assessment during RFA with the current CT technology, which produced a high CT number reproducibility and stable measurement at different CT acquisition parameters. Despite being affected by metal artifacts, the CT-based thermometry could be further developed as a tissue temperature monitoring tool during CT-guided thermal ablation.


Asunto(s)
Resinas Acrílicas/química , Ablación por Radiofrecuencia/métodos , Termometría/métodos , Tomografía Computarizada por Rayos X/métodos
2.
J Vasc Access ; 23(2): 225-231, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33438482

RESUMEN

OBJECTIVE: To compare catheter related blood stream infection (CRBSI) rate between cuffed tunnelled and non-cuffed tunnelled PICC. METHODS: We prospectively followed 100 patients (50:50 cuffed and non-cuffed PICC) and compared CRBSI rate between these groups. Daily review and similar catheter care were performed until a PICC-related complication, completion of therapy, death or defined end-of-study date necessitate removal. CRBSI was confirmed in each case by demonstrating concordance between isolates colonizing the PICC at the time of infection and from peripheral blood cultures. RESULTS: A total of 50 cuffed PICC were placed for 1864 catheter-days. Of these, 12 patients (24%) developed infection, for which 5 patients (10%) had a CRBSI for a rate of 2.7 per 1000 catheter-days. Another 50 tunnelled non-cuffed PICCs were placed for 2057 catheter-days. Of these, 7 patients (14%) developed infection, for which 3 patients (6%) had a CRBSI. for a rate of 1.5 per 1000 catheter-days. The mean time to development of infection is 24 days in cuffed and 19 days in non-cuffed groups. The mean duration of utilization was significantly longer in non-cuffed than in cuffed group (43 days in non-cuffed vs 37 days in cuffed group, p = 0.008). CONCLUSIONS: Cuffed PICC does not further reduce the rate of local or bloodstream infection. Tunnelled non-cuffed PICC is shown to be as effective if not better at reducing risk of CRBSI and providing longer catheter dwell time compared to cuffed PICC.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Sepsis , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/etiología , Cateterismo Venoso Central/efectos adversos , Cateterismo Periférico/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Humanos , Estudios Retrospectivos
3.
Sci Rep ; 11(1): 2299, 2021 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-33504909

RESUMEN

Microwave ablation (MWA) is gaining popularity for the treatment of small primary hepatocellular carcinoma and metastatic lesions especially if patients are not candidates for surgical resection. Deep neuromuscular blockade (DMB) is perceived to improve surgical working conditions compared to moderate neuromuscular blockade (MMB) but no studies have examined the same benefits in MWA of liver tumours. This study aimed to compare the clinical outcomes of DMB and MMB in MWA of liver tumours in terms of liver excursion, performance scores by the interventional radiologists and patients, requirements of additional muscle relaxants and complications. 50 patients were recruited and 45 patients (22 in MMB group, 23 in DMB group) completed the study. The mean liver excursion for the MMB group (1.42 ± 1.83 mm) was significantly higher than the DMB group (0.26 ± 0.38 mm) (p = 0.001). The mean Leiden-Surgical Rating Scale (L-SRS) rated by the two interventional radiologists were 4.5 ± 0.59 and 3.6 ± 0.85 for the DMB and MMB groups, respectively (p = 0.01). There was also statistically significant difference on patient satisfaction scores (0-10: Extremely Dissatisfied-Extremely Satisfied) between DMB (8.74 ± 1.1) and MMB (7.86 ± 1.25) groups (p = 0.01). 5 patients from MMB group and none from DMB group required bolus relaxant during the MWA procedure. Adverse events were also noted to be more severe in the MMB group. In conclusion, DMB significantly reduced liver excursion and movement leading to improved accuracy, safety and success in ablating liver tumour.


Asunto(s)
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Microondas , Bloqueo Neuromuscular/métodos , Anciano , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Phys Med ; 82: 40-45, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33581616

RESUMEN

PURPOSE: To investigate the efficacy of a newly-developed laser-heated core biopsy needle in the thermal ablation of biopsy tract to reduce hemorrhage after biopsy using in vivo rabbit's liver model. MATERIALS AND METHODS: Five male New Zealand White rabbits weighed between 1.5 and 4.0 kg were anesthetized and their livers were exposed. 18 liver biopsies were performed under control group (without tract ablation, n = 9) and study group (with tract ablation, n = 9) settings. The needle insertion depth (~3 cm) and rate of retraction (~3 mm/s) were fixed in all the experiments. For tract ablation, three different needle temperatures (100, 120 and 150 °C) were compared. The blood loss at each biopsy site was measured by weighing the gauze pads before and after blood absorption. The rabbits were euthanized immediately and the liver specimens were stained with hematoxylin-eosin (H&E) for further histopathological examination (HPE). RESULTS: The average blood loss in the study group was reduced significantly (p < 0.05) compared to the control group. The highest percentage of bleeding reduction was observed at the needle temperature of 150 °C (93.8%), followed by 120 °C (85.8%) and 100 °C (84.2%). The HPE results show that the laser-heated core biopsy needle was able to cause lateral coagulative necrosis up to 14 mm diameter along the ablation tract. CONCLUSION: The laser-heated core biopsy needle reduced hemorrhage up to 93.8% and induced homogenous coagulative necrosis along the ablation tract in the rabbits' livers. This could potentially reduce the risk of tumor seeding in clinical settings.


Asunto(s)
Hemorragia , Hígado , Animales , Biopsia con Aguja , Calor , Rayos Láser , Masculino , Conejos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda