Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Langmuir ; 40(9): 4709-4718, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-38388349

RESUMEN

Constructing three-dimensional (3D) aligned nanofiber scaffolds is significant for the development of cardiac tissue engineering, which is promising in the field of drug discovery and disease mechanism study. However, the current nanofiber scaffold preparation strategy, which mainly includes manual assembly and hybrid 3D printing, faces the challenge of integrated fabrication of morphology-controllable nanofibers due to its cross-scale structural feature. In this research, a trench-guided electrospinning (ES) strategy was proposed to directly fabricate 3D aligned nanofiber scaffolds with alternative ES and a direct ink writing (DIW) process. The electric field effect of DIW poly(dimethylsiloxane) (PDMS) side walls on guiding whipping ES nanofibers was investigated to construct trench design rules. It was found that the width/height ratio of trenches greatly affected the nanofiber alignment, and the trench width/height ratio of 1.5 provided the nanofiber alignment degree over 60%. As a proof of principle, 3D nanofiber scaffolds with controllable porosity (60-80%) and alignment (30-60%) were fabricated. The effect of the scaffolds was verified by culturing human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), which resulted in the uniform 3D distribution of aligned hiPSC-CMs with ∼1000 µm thickness. Therefore, this printing strategy shows great potential for the efficient engineered tissue construction.


Asunto(s)
Nanofibras , Ingeniería de Tejidos , Humanos , Nanofibras/química , Andamios del Tejido/química , Miocitos Cardíacos
2.
Small ; 19(5): e2206628, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36446727

RESUMEN

The in situ free carbon generated in polymer-derived ceramics (PDCs) plays a crucial role in their unique microstructure and resultant properties. This study advances a new phenomenon of graphitization of PDCs. Specifically, whether in micro-/nanoscale films or millimeter-scale bulks, the surface/interface radically changes the fate of carbon and the evolution of PDC nanodomains, promotes the graphitization of carbon, and evolves a free carbon enriched layer in the near-surface/interface region. Affected by the enrichment behavior of free carbon in the near-surface/interface region, PDCs exhibit highly abnormal properties such as the skin behavior and edge effect of the current. The current intensity in the near-surface/interface region of PDCs is orders of magnitude higher than that in its interior. Ultrahigh conductivity of up to 14.47 S cm-1 is obtained under the action of the interface and surface, which is 5-8 orders of magnitude higher than that of the bulk prepared under the same conditions. Such surface/interface interactions are of interest for the regulation of free carbon and its resultant properties, which are the core of PDC applications. Finally, the first PDC thin-film strain gauge that can survive a butane flame with a high temperature of up to ≈1300 °C is fabricated.

3.
Biochem Biophys Res Commun ; 552: 84-90, 2021 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-33743352

RESUMEN

BACKGROUND: Angiotensin II (Ang II), an important component of the renin-angiotensin system (RAS), plays a critical role in the pathogenesis of cardiovascular disorders. In addition, human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) have been considered as a promising platform for studying personalized medicine for heart diseases. However, whether Ang II can induce the apoptosis of hiPSC-CMs is not known. METHODS: In this study, we treated hiPSC-CMs with different concentrations of Ang II [0 nM (vehicle as a control), 1 nM, 10 nM, 100 nM, 1 µM, 10 µM, 100 µM, and 1 mM] for various time periods (24 h, 48 h, 6 days, and 10 days) and analyzed the viability and apoptosis of hiPSC-CMs. RESULTS: We found that treatment with 1 mM Ang II for 10 days reduced the viability of hiPSC-CMs by 41% (p = 2.073E-08) and increased apoptosis by 2.74-fold, compared to the control group (p = 6.248E-12). MYOG, which encodes the muscle-specific transcription factor myogenin, was also identified as an apoptosis-suppressor gene in Ang II-treated hiPSC-CMs. Ectopic MYOG expression decreased the apoptosis and increased the viability of Ang II-treated hiPSC-CMs. Further analysis of the RNA sequencing (RNA-seq) data illustrated that myogenin ameliorated Ang II-induced apoptosis of hiPSC-CMs by downregulating the expression of proinflammatory genes. CONCLUSION: Our findings suggest that Ang II induces the apoptosis of hiPSC-CMs and that myogenin attenuates Ang II-induced apoptosis.


Asunto(s)
Angiotensina II/farmacología , Apoptosis/efectos de los fármacos , Regulación de la Expresión Génica , Células Madre Pluripotentes Inducidas/metabolismo , Miocitos Cardíacos/metabolismo , Miogenina/genética , Apoptosis/genética , Células Cultivadas , Perfilación de la Expresión Génica/métodos , Humanos , Células Madre Pluripotentes Inducidas/citología , Miocitos Cardíacos/citología , Miogenina/metabolismo , Factores de Tiempo
4.
Langmuir ; 34(45): 13788-13793, 2018 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-30354156

RESUMEN

Gap electrospinning is a facile technique to produce aligned nanofibers useful for many applications, but its potential has not yet been fully exploited in nature, leading to the fiber length still limited to several tens of centimeters at present. In this work, we report a breakthrough in the production of well-aligned nanofibers with record length and efficiency. Using a suitable poly(vinylidene fluoride) solution and a pair of parallel plates that are substrate-free and negatively connected, we demonstrate the ease of this technique to prepare length-controllable aligned fibers in a wide range (≤125 cm). Because of the crucial roles of both the jet whipping instability that continuously drives the jet to span across the static plates and the negative voltage on the plates that effectively attracts the positively charged jet, the jet can be made to move back and forth over the superlarge gap to form ultralong aligned nanofibers. By introducing a projection method, we also redefine fiber alignment in a broader sense. This work is believed to provide a new insight into the nature of gap electrospinning, which will greatly expand the versatility of this technique to create devices for a myriad of applications.

5.
Sensors (Basel) ; 18(12)2018 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-30551579

RESUMEN

Ammonia gas sensors are very essential in many industries and everyday life. However, their complicated fabrication process, severe environmental fabrication requirements and desorption of residual ammonia molecules result in high cost and hinder their market acceptance. Here, laser direct writing is used to fabricate three parallel porous 3D graphene lines on a polyimide (PI) tape to simply construct an ammonia gas sensor. The middle one works as an ammonia sensing element and the other two on both sides work as heaters to improve the desorption performance of the sensing element to ammonia gas molecules. The graphene lines were characterized by scanning electron microscopy and Raman spectroscopy. The response and recovery time of the sensor without heating are 214 s and 222 s with a sensitivity of 0.087% ppm-1 for sensing 75 ppm ammonia gas, respectively. The experimental results prove that under the optimized heating temperature of about 70 °C the heaters successfully help implement complete desorption of residual NH3 showing a good sensitivity and cyclic stability.

6.
Opt Lett ; 42(24): 5106-5109, 2017 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-29240148

RESUMEN

A simple fabrication method of micro/nano-optical fibers (MNOFs) based on near-field melt electrospinning (NMES) is proposed in this Letter. Single fibers with diameters ranging from 500 nm to 6 µm were directly written by near-field electrospinning of molten poly(methyl methacrylate) (PMMA). The morphology and transmission characteristics of single PMMA MNOFs were experimentally measured. The results showed that PMMA MNOFs have the advantages of smooth surfaces, uniform diameters, and low loss. As an example of one-step fabrication for MNOF devices, a planar helical MNOF structure was directly written and optically characterized. To demonstrate the versatility of the NMES process, in combination with the microfluidic technique, a liquid refractive index-sensing chip was fabricated and tested. Our results demonstrate that the proposed fabrication method has strong potential in the direct writing of patterned optical devices and heterogeneous integrated devices.

7.
Nanotechnology ; 27(31): 31LT01, 2016 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-27324992

RESUMEN

The rapid production and accurate deposition of graphene composites are first integrated into one process, due to the strong interaction between the polymer bond with sodium dodecyl sulfonate (SDS) and graphene. It is demonstrated that tension-shear exfoliation in high viscosity fluid may get a higher graphene production rate than in N-methyl-pyrrolidone. In addition, the micro-scale patterns of graphene nanomaterials produced by this method show high electrical conductivity and superior sensitivity to pressure due to their porous structure.

8.
Sensors (Basel) ; 16(2): 158, 2016 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-26821031

RESUMEN

A novel structure of the resonant pressure sensor is presented in this paper, which tactfully employs intercoupling between dual pressure-sensing diaphragms and a laterally driven resonant strain gauge. After the resonant pressure sensor principle is introduced, the coupling mechanism of the diaphragms and resonator is analyzed and the frequency equation of the resonator based on the triangle geometry theory is developed for this new coupling structure. The finite element (FE) simulation results match the theoretical analysis over the full scale of the device. This pressure sensor was first fabricated by dry/wet etching and thermal silicon bonding, followed by vacuum-packaging using anodic bonding technology. The test maximum error of the fabricated sensor is 0.0310%F.S. (full scale) in the range of 30 to 190 kPa, its pressure sensitivity is negative and exceeding 8 Hz/kPa, and its Q-factor reaches 20,000 after wafer vacuum-packaging. A novel resonant pressure sensor with high accuracy is presented in this paper.

9.
Talanta ; 276: 126261, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38761659

RESUMEN

Intracellular calcium ion detection is of great significance for understanding the cell metabolism and signaling pathways. Most of the current ionic sensors either face the size issue or sensitivity limit for the intracellular solution with high background ion concentrations. In this paper, we proposed a calmodulin (CaM) functionalized nanopore for sensitive and selective Ca2+ detection inside living cells. A salt gradient was created when the nanopore sensor filled with a low concentration electrolyte was in contact with a high background concentration solution, which enhanced the surface charge-based detection sensitivity. The nanopore sensor showed a 10 × sensitivity enhancement by application of a 100-fold salt gradient, and a detection limit of sub nM. The sensor had a wide detection range from 1 nM to 1 mM, and allowed for quick calcium ion quantification in a few seconds. The sensor was demonstrated for intracellular Ca2+ detection in A549 cells in response to ionomycin.


Asunto(s)
Calcio , Calmodulina , Nanoporos , Humanos , Calcio/análisis , Calmodulina/análisis , Calmodulina/química , Calmodulina/metabolismo , Células A549 , Límite de Detección , Técnicas Biosensibles/métodos , Ionomicina/farmacología
10.
Microsyst Nanoeng ; 10: 96, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39006908

RESUMEN

Heart-on-a-chip (HoC) has emerged as a highly efficient, cost-effective device for the development of engineered cardiac tissue, facilitating high-throughput testing in drug development and clinical treatment. HoC is primarily used to create a biomimetic microphysiological environment conducive to fostering the maturation of cardiac tissue and to gather information regarding the real-time condition of cardiac tissue. The development of architectural design and advanced manufacturing for these "3S" components, scaffolds, stimulation, and sensors is essential for improving the maturity of cardiac tissue cultivated on-chip, as well as the precision and accuracy of tissue states. In this review, the typical structures and manufacturing technologies of the "3S" components are summarized. The design and manufacturing suggestions for each component are proposed. Furthermore, key challenges and future perspectives of HoC platforms with integrated "3S" components are discussed. Architecture design concepts of scaffolds, stimulation and sensors in chips.

11.
Sci Rep ; 14(1): 15695, 2024 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977824

RESUMEN

Hydrogels are extensively explored as biomaterials for tissue scaffolds, and their controlled fabrication has been the subject of wide investigation. However, the tedious mechanical property adjusting process through formula control hindered their application for diverse tissue scaffolds. To overcome this limitation, we proposed a two-step process to realize simple adjustment of mechanical modulus over a broad range, by combining digital light processing (DLP) and post-processing steps. UV-curable hydrogels (polyacrylamide-alginate) are 3D printed via DLP, with the ability to create complex 3D patterns. Subsequent post-processing with Fe3+ ions bath induces secondary crosslinking of hydrogel scaffolds, tuning the modulus as required through soaking in solutions with different Fe3+ concentrations. This innovative two-step process offers high-precision (10 µm) and broad modulus adjusting capability (15.8-345 kPa), covering a broad range of tissues in the human body. As a practical demonstration, hydrogel scaffolds with tissue-mimicking patterns were printed for cultivating cardiac tissue and vascular scaffolds, which can effectively support tissue growth and induce tissue morphologies.


Asunto(s)
Hidrogeles , Impresión Tridimensional , Ingeniería de Tejidos , Andamios del Tejido , Andamios del Tejido/química , Hidrogeles/química , Ingeniería de Tejidos/métodos , Humanos , Alginatos/química , Materiales Biocompatibles/química , Resinas Acrílicas/química , Módulo de Elasticidad , Luz
12.
ACS Appl Mater Interfaces ; 16(1): 966-974, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38109359

RESUMEN

Monitoring high-temperature strain on curved components in harsh environments is a challenge for a wide range of applications, including in aircraft engines, gas turbines, and hypersonic vehicles. Although there are significant improvements in the preparation of high-temperature piezoresistive film on planar surfaces using 3D printing methods, there are still difficulties with poor surface compatibility and high-temperature strain testing on curved surfaces. Herein, a conformal direct ink writing (CDIW) system coupled with an error feedback regulation strategy was used to fabricate high-precision, thick films on curved surfaces. This strategy enabled the maximum amount of error in the distance between the needle and the substrate on a curved surface to be regulated from 155 to 4 µm. A conformal Pt thick-film strain gauge (CPTFSG) with a room-temperature strain coefficient of 1.7 was created on a curved metallic substrate for the first time. The resistance drift rate at 800 °C for 1 h was 1.1%, which demonstrated the excellent stability and oxidation resistance of the CPTFSG. High-temperature dynamic strain tests up to 769 °C revealed that the sensor had excellent high-temperature strain test performance. Furthermore, the CPTFSG was conformally deposited on an aero-engine turbine blade to perform in situ tensile and compressive strain testing at room temperature. High-temperature strain tests were conducted at 100 and 200 °C for 600 and 580 µÎµ, respectively, demonstrating a high steady-state response consistent with the commercial high-temperature strain transducer. In addition, steady-state strain tests at high temperatures up to 496 °C were tested. The CDIW error modulation strategy provides a highly promising approach for the high-precision fabrication of Pt thick films on complex surfaces and driving in situ sensing of high-temperature parameters on curved components toward practical applications.

13.
J Colloid Interface Sci ; 658: 913-922, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38157615

RESUMEN

Thin-film sensors are essential for real-time monitoring of components in high-temperature environments. Traditional fabrication methods often involve complicated fabrication steps or require prolonged high-temperature annealing, limiting their practical applicability. Here, we present an approach using direct ink writing and laser scanning (DIW-LS) to fabricate high-temperature functional thin films. An indium tin oxide (ITO)/preceramic polymer (PP) ink suitable for DIW was developed. Under LS, the ITO/PP thin film shrank in volume. Meanwhile, the rapid pyrolysis of PP into amorphous precursor-derived ceramic (PDC) facilitated the faster sintering of ITO nanoparticles and improved the densification of the thin film. This process realized the formation of a conductive network of interconnected ITO nanoparticles. The results show that the ITO/PDC thin film exhibits excellent stability, with a drift rate of 4.7 % at 1000 °C for 25 h, and withstands temperatures up to 1250 °C in the ambient atmosphere. It is also sensitive to strain, with a maximum gauge factor of -6.0. As a proof of concept, we have used DIW-LS technology to fabricate a thin-film heat flux sensor on the surface of the turbine blade, capable of measuring heat flux densities over 1 MW/m2. This DIW-LS process provides a viable approach for the integrated, rapid, and flexible fabrication of thin film sensors for harsh environments.

14.
Front Biosci (Landmark Ed) ; 29(2): 49, 2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38420814

RESUMEN

BACKGROUND: Myogenin is well known as a crucial transcription factor in skeletal muscle development, yet its other biological functions remain unexplored. Previous research showed that myogenin suppresses apoptosis induced by angiotensin II in human induced pluripotent stem cell-derived cardiomyocytes, and offered a new perspective on myogenin's role in cardioprotection. However, the detailed mechanism of this cardioprotection, especially under oxidative stress, is still unclear. METHODS: In this study, hydrogen peroxide (H2O2) was used to generate reactive oxygen species in myogenin-overexpressing cardiomyocytes. The apoptosis was examined by flow cytometry. Transcriptome sequencing (RNA-seq) was performed to identify genes regulated by myogenin. Western blotting was used to detect the protein level of DUSP13 and the phosphorylation level of p38 mitogen-activated protein kinase (MAPK). The dual-luciferase reporter assay and ChIP assay were used to confirm the binding of myogenin to the promoter region of DUSP13. DUSP13 overexpression and knockdown assays were performed to study its anti-apoptotic role. RESULTS: Flow cytometry analysis of apoptosis showed that overexpressing myogenin for 24 and 48 hours decreased the apoptotic ratio by 47.9% and 63.5%, respectively, compared with untreated controls. Transcriptome sequencing performed on cardiomyocytes that expressed myogenin for different amounts of time (6, 12, 24, and 48 hours) identified DUSP13 as being up-regulated by myogenin. Western blotting showed that overexpression of myogenin increased the expression of DUSP13 and decreased the phosphorylation level of p38 MAPK. A dual-luciferase reporter assay proved that myogenin bound directly to the promoter region of DUSP13 and led to strong relative luciferase activity. Direct expression of DUSP13A and DUSP13B significantly reduced the rates of apoptosis and necrosis in cells treated with H2O2. Knockdown of DUSP13B significantly increased the rate of apoptosis in cells treated with H2O2. CONCLUSIONS: The present findings suggest that myogenin might attenuate apoptosis induced by reactive oxygen species by up-regulating DUSP13 and inactivating the p38 MAPK pathway.


Asunto(s)
Peróxido de Hidrógeno , Células Madre Pluripotentes Inducidas , Humanos , Especies Reactivas de Oxígeno/metabolismo , Peróxido de Hidrógeno/farmacología , Miogenina/genética , Miogenina/metabolismo , Células Madre Pluripotentes Inducidas/metabolismo , Apoptosis , Estrés Oxidativo , Proteínas Quinasas p38 Activadas por Mitógenos/genética , Proteínas Quinasas p38 Activadas por Mitógenos/metabolismo , Luciferasas/metabolismo
15.
Polymers (Basel) ; 15(15)2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37571213

RESUMEN

Polymer-derived ceramic (PDC) thin-film sensors have a very high potential for extreme environments. However, the erosion caused by high-temperature airflow at the hot-end poses a significant challenge to the stability of PDC thin-film sensors. Here, we fabricate a thin-film coating by PDC/TiB2/B composite ceramic material, which can be used to enhance the oxidation resistance and ablation resistance of the sensors. Due to the formation of a dense oxide layer on the surface of the thin-film coating in a high-temperature air environment, it effectively prevents the ingress of oxygen as a pivotal barrier. The coating exhibits an exceptionally thin oxide layer thickness of merely 8 µm, while its oxidation resistance was rigorously assessed under air exposure at 800 °C, proving its enduring protection for a minimum duration of 10 h. Additionally, during ablation testing using a flame gun that can generate temperatures of up to 1000 °C, the linear ablation rate of thin-film coating is merely 1.04 µm/min. Our analysis reveals that the volatilization of B2O3 occurs while new SiO2 is formed on the thin-film coating surface. This phenomenon leads to the absorption of heat, thereby enhancing the ablative resistance performance of the thin-film sensor. The results indicate that the thin-film sensor exhibits exceptional resistance to oxidation and ablation when protected by the coating, which has great potential for aerospace applications.

16.
Micromachines (Basel) ; 14(9)2023 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-37763882

RESUMEN

Thin-film sensors are regarded as advanced technologies for in situ condition monitoring of components operating in harsh environments, such as aerospace engines. Nevertheless, these sensors encounter challenges due to the high-temperature oxidation of materials and intricate manufacturing processes. This paper presents a simple method to fabricate high temperature-resistant oxidized SiCN precursor and La(Ca)CrO3 composite thin film temperature sensors by screen printing and air annealing. The developed sensor demonstrates a broad temperature response ranging from 200 °C to 1100 °C with negative temperature coefficients (NTC). It exhibits exceptional resistance to high-temperature oxidation and maintains performance stability. Notably, the sensor's resistance changes by 3% after exposure to an 1100 °C air environment for 1 h. This oxidation resistance improvement surpasses the currently reported SiCN precursor thin-film sensors. Additionally, the sensor's temperature coefficient of resistance (TCR) can reach up to -7900 ppm/°C at 200 °C. This strategy is expected to be used for other high-temperature thin-film sensors such as strain gauges, heat flux sensors, and thermocouples. There is great potential for applications in high-temperature field monitoring.

17.
Microsyst Nanoeng ; 9: 5, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36620391

RESUMEN

The tactile pressure sensor is of great significance in flexible electronics, but sensitivity customization over the required working range with high linearity still remains a critical challenge. Despite numerous efforts to achieve high sensitivity and a wide working range, most sensitive microstructures tend to be obtained only by inverting naturally existing templates without rational design based on fundamental contact principles or models for piezoresistive pressure sensors. Here, a positive design strategy with a hyperelastic model and a Hertzian contact model for comparison was proposed to develop a flexible pressure sensor with highly customizable linear sensitivity and linearity, in which the microstructure distribution was precalculated according to the desired requirement prior to fabrication. As a proof of concept, three flexible pressure sensors exhibited sensitivities of 0.7, 1.0, and 1.3 kPa- 1 over a linear region of up to 200 kPa, with a low sensitivity error (<5%) and high linearity (~0.99), as expected. Based on the superior electromechanical performance of these sensors, potential applications in physiological signal recognition are demonstrated as well, and such a strategy could shed more light on demand-oriented scenarios, including designable working ranges and linear sensitivity for next-generation wearable devices.

18.
ACS Appl Mater Interfaces ; 15(3): 4713-4723, 2023 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-36623166

RESUMEN

Stretchable electrodes are desirable in flexible electronics for the transmission and acquisition of electrical signals, but their fabrication process remains challenging. Herein, we report an approach based on patterned liquid metals (LMs) as stretchable electrodes using a super-hydrophilic laser-induced graphene (SHL-LIG) process with electroless plating copper on a polyimide (PI) film. The LMs/SHL-LIG structures are then transferred from the PI film to an Ecoflex substrate as stretchable electrodes with an ultralow sheet resistance of 3.54 mΩ per square and excellent stretchability up to 480% in elongation. Furthermore, these electrodes show outstanding performances of only 8% electrical resistance changes under a tensile strain of 300%, and strong immunity to temperature and pressure changes. As demonstration examples, these electrodes are integrated with a stretchable strain sensing system and a smart magnetic soft robot toward practical applications.

19.
Artículo en Inglés | MEDLINE | ID: mdl-36780511

RESUMEN

Polymer-derived ceramic (PDC)-based high-temperature thin-film sensors (HTTFSs) exhibit promising applications in the condition monitoring of critical components in aerospace. However, fabricating PDC-based HTTFS integrated with high-efficiency, high-temperature anti-oxidation, and customized patterns remains challenging. In this work, we introduce a rapid and flexible selecting laser pyrolysis combined with a direct ink writing process to print double-layer high-temperature antioxidant PDC composite thin-film thermistors under ambient conditions. The sensitive layer (SL) was directly written on an insulating substrate with excellent conductivity by laser-induced graphitization. Then, the antioxidant layer (AOL) was written on the surface of the SL to realize the integrated manufacturing of double-functional layers. Through characterization analysis, it was shown that B2O3 and SiO2 glass phases generated by the PDC composite AOL could effectively prevent oxygen intrusion. Therefore, the fabricated PDC composite thermistors exhibited a negative temperature coefficient in the temperature range from 100 to 1100 °C and high repeatability below 800 °C. Meanwhile, it has excellent high-temperature stability at 800 °C with a resistance change of only 2.4% in 2 h. Furthermore, the high-temperature electrical behavior of the thermistor was analyzed. The temperature dependence of the conductivity for this thermistor has shown an agreement with the Mott's variable range hopping mechanism. Additionally, the thermistor was fabricated on the surface of an aero-engine blade to verify its feasibility below 800 °C, showing the great potential of this work for state sensing on the surface of high-temperature components, especially for customized requirements.

20.
Micromachines (Basel) ; 14(8)2023 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-37630157

RESUMEN

Current methods for thin film sensors preparation include screen printing, inkjet printing, and MEMS (microelectromechanical systems) techniques. However, their limitations in achieving sub-10 µm line widths hinder high-density sensors array fabrication. Electrohydrodynamic (EHD) printing is a promising alternative due to its ability to print multiple materials and multilayer structures with patterned films less than 10 µm width. In this paper, we innovatively proposed a method using only EHD printing to prepare ultra-micro thin film temperature sensors array. The sensitive layer of the four sensors was compactly integrated within an area measuring 450 µm × 450 µm, featuring a line width of less than 10 µm, and a film thickness ranging from 150 nm to 230 nm. The conductive network of silver nanoparticles exhibited a porosity of 0.86%. After a 17 h temperature-resistance test, significant differences in the performance of the four sensors were observed. Sensor 3 showcased relatively superior performance, boasting a fitted linearity of 0.99994 and a TCR of 937.8 ppm/°C within the temperature range of 20 °C to 120 °C. Moreover, after the 17 h test, a resistance change rate of 0.17% was recorded at 20 °C.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda