Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Vox Sang ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38950904

RESUMEN

BACKGROUND AND OBJECTIVES: Quantifying the contribution of individual coagulation factors to haemostasis may aid our understanding of the haemostatic function in patients with rare coagulation deficiencies (RCDs) and the exploration of suitable treatments. MATERIALS AND METHODS: Reconstituted blood prepared from specific coagulation factor-deficient plasma (factor [F]II; prothrombin, FV, FVII, FVIII, FIX, FX, FXI or FXII) and red blood cell/platelet products were used to simulate the whole blood of patients with RCD. We prepared in vitro treatment models for patients with prothrombin deficiency using coagulation factor agents and fresh frozen plasma. Haemostatic function was measured using a microchip flow chamber system at 600 s-1. RESULTS: The haemostatic function was low, especially in blood samples reconstituted with prothrombin- and FX-deficient plasma. In a plasma transfusion model of prothrombin deficiency, haemostatic function recovered after 10% replacement with normal plasma and reached a plateau at ≧60% replacement. A treatment model of prothrombin deficiency with prothrombin complex concentrates revealed dose-dependent therapeutic effects in the range of 0-50 IU/kg. CONCLUSION: Microchip flow chamber system-based quantification of haemostatic function using reconstituted blood could predict haemostasis and therapeutic effects of treatments in patients with prothrombin deficiency.

2.
Vox Sang ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38785048

RESUMEN

BACKGROUND AND OBJECTIVES: The total thrombus-formation analysis system (T-TAS) can quantitatively analyse the contribution of platelets to haemostasis using reconstituted blood samples. However, it is unsuitable in cases with low platelet counts. We introduced a haemodilution (HD) chip with a shallow chamber depth, adapted to low platelet counts and high shear conditions (1500 s-1). MATERIALS AND METHODS: Blood samples were prepared by mixing red blood cell products, standard human plasma and platelet products; the final platelet count was 50 × 103/µL. Aggregation tests were performed by using the aggregation inducers collagen, adenosine diphosphate (ADP) and ristocetin. Samples with 2-, 4- and 9-day-old platelet products (N = 10) were evaluated. RESULTS: The HD chip enabled the stable analysis of the haemostatic function of all samples at a platelet count of 50 × 103/µL. Haemostatic function was correlated with ADP aggregation (time to 10 kPa [T10]: r = -0.53; area under the curve for 30 min: r = 0.40) and storage period (T10: r = 0.44). CONCLUSION: The HD chip-mounted T-TAS can stably analyse haemostatic function under low platelet counts and high shear conditions; this approach is expected to serve as a bridge to in vivo haemostatic tests with experimental animals.

3.
Vox Sang ; 118(5): 367-375, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36862116

RESUMEN

BACKGROUND AND OBJECTIVES: Currently, the quality of platelet (PLT) products is evaluated using a series of in vitro tests, which only analyse PLTs as an inspection material. However, it would be ideal to assess the physiological functions of PLTs under conditions similar to the sequential blood haemostatic process. In this study, we attempted to establish an in vitro system where the thrombogenicity of PLT products was evaluated in the presence of red blood cells (RBCs) and plasma using a microchamber under constant shear stress (600/s). MATERIALS AND METHODS: Blood samples were reconstituted by mixing PLT products, standard human plasma (SHP) and standard RBCs. Each component was serially diluted keeping the other two components fixed. The samples were applied onto a flow chamber system (Total Thrombus-formation Analysis System [T-TAS]), and white thrombus formation (WTF) was assessed under large arterial shear conditions. RESULTS: We observed a good correlation between the PLT numbers in the test samples and WTF. The WTF of samples containing ≦10% SHP was significantly lower than those containing ≧40% SHP, and no difference was observed in WTF among samples containing 40%-100% SHP. WTF significantly declined in the absence of RBCs, whereas no change in WTF was observed in the presence of RBCs, over haematocrit range of 12.5%-50%. CONCLUSION: The WTF assessed on the T-TAS using reconstituted blood may serve as a new physiological blood thrombus test to quantitatively determine the quality of PLT products.


Asunto(s)
Trombosis , Humanos , Plaquetas , Eritrocitos , Hemostasis , Recuento de Plaquetas
4.
Transfusion ; 62(11): 2262-2270, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36148524

RESUMEN

BACKGROUND: Washed platelet concentrates (WPC), prepared with an automated system cell processor (ACP), have recently been approved to be manufactured and marketed in Japan. From the perspective of risk management, it is preferable to secure alternative technologies for ACP. Here, we conducted a study to evaluate the quality of WPC prepared using an automated membrane filtration-based system, Lovo. STUDY DESIGN AND METHODS: Replaced PCs prepared from apheresis PCs were equally divided into control and test units, and subsequently washed using ACP and Lovo respectively. Work and operational efficiencies were evaluated by in vitro analyses, including total handling time, platelet recovery, and plasma protein removal rate. Product quality, including a set of biochemical and physiological indicators of platelets and supernatants, were assessed before and 3 days after washing. RESULTS: In vitro platelet recovery rates and plasma protein removal rates were >85% and >95%, respectively, in both groups. The pH values on day 0 were significantly high (6.97 vs. 6.86) due to low pCO2 in the test group, while no significant differences in glucose consumption and lactate production were observed between the two groups. The levels of hypotonic shock responses, aggregation response, platelet shape, CD62P expression, and sCD62P concentration were similar in both groups during the 3-day storage period. CONCLUSION: Platelet washing with Lovo provides platelet quality equivalent to, or better than, conventional washing with ACP. Thus, the new automated system, Lovo, can be considered as an alternative to ACP for WPC preparation.


Asunto(s)
Eliminación de Componentes Sanguíneos , Conservación de la Sangre , Humanos , Plaquetas/metabolismo , Proteínas Sanguíneas/metabolismo , Japón , Filtración
5.
Vox Sang ; 117(6): 812-821, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35262934

RESUMEN

BACKGROUND AND OBJECTIVES: Frozen-thawed red blood cells (FTRCs) are useful blood components to patients with rare blood phenotypes. However, frozen red blood cells (FRCs) sometimes cause significant haemolysis after thawing due to the freeze/thaw process. In this study, we aimed to focus on the former process and reduce process-related haemolysis. MATERIALS AND METHODS: Five-day-old red blood cells (RBCs) (5D) or 9-week-old RBCs (9 W) were glycerolized, pooled and split into two aliquots. RBCs were frozen using either the programmed freezer (PF) method or the deep freezer (DF) method. After 4-8 weeks, the FRCs were thawed and washed. In vitro characteristics were compared between the PF and DF methods. Nine week were used as a starting material for FTRCs with the assumption that they can mimic disqualified FTRCs with respect to Hb recovery. RESULTS: The PF method resulted in a significantly higher Hb recovery rate than the DF method (5D: 85.9 ± 2.1 vs. 81.1% ± 3.5%, p < 0.001) (9 W: 56.8 ± 4.0 vs. 52.4% ± 3.5%, p < 0.001). Both 5D and 9W-derived FTRCs immediately after preparation prepared by the PF method were more resistible to haemolysis than those prepared by the DF method. On the other hand, there were no significant differences between PF and DF methods in Adenosine 5'-triphosphate (ATP) and 2,3-diphosphoglycerate (2,3-DPG). CONCLUSION: The PF method was more suitable for RBC freezing than the DF method in terms of Hb recovery in FTRCs. Although it was only 4%-5%, the improvement in the Hb recovery rate will contribute to a more stable supply.


Asunto(s)
Conservación de la Sangre , Hemólisis , Adenosina Trifosfato , Conservación de la Sangre/métodos , Criopreservación/métodos , Recuento de Eritrocitos , Eritrocitos , Congelación , Humanos
6.
Vox Sang ; 117(1): 49-57, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34082471

RESUMEN

BACKGROUND AND OBJECTIVES: Platelet concentrates suspended in a platelet additive solution (PAS-PC) are associated with a reduction in allergic response and are suitable for preparing pathogen-inactivated PC. We aimed to develop an efficient platform for the dual preparation of PAS-PC and platelet-poor plasma. MATERIALS AND METHODS: PAS-PC was prepared in six steps by using a hollow-fibre system based on cross-flow filtration: priming, loading PC, loading PAS, collection of filtered liquid (flow-through) and collection of platelets by washing with PAS followed by washing with air. In this study, the efficacy of platelet and plasma protein recovery and characteristics of recovered PAS-PC and flow-through plasma were analysed in detail. RESULTS: Recoveries of platelet in PAS-PC and plasma protein in the flow-through were 95.4% ± 3.7% and 61.6% ± 5.0%, respectively. The residual plasma protein in PAS-PC was 34.1% ± 2.8%. Although the expression level of CD62P, a platelet activation marker, in recovered platelets was approximately 1.2-fold of that in original platelets, swirling patterns were well retained, and aggregation in PAS-PC was not visible. Agonist-induced aggregabilities, platelet morphology and hypotonic shock recovery were conserved. The patterns of plasma protein and lipoprotein in the flow-through were comparable with those in the original PCs. The multimeric pattern analysis of VWF remained unaltered. CONCLUSION: We propose a highly efficient preparation system that enables the simultaneous production of PAS-PC and platelet-poor plasma. It also achieves a high recovery of functionally well-retained platelets with very low activation.


Asunto(s)
Conservación de la Sangre , Activación Plaquetaria , Plaquetas , Humanos , Presión Osmótica , Plasma
7.
Vox Sang ; 117(1): 119-127, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34081781

RESUMEN

BACKGROUND AND OBJECTIVES: Haematopoietic cell transplantation (HCT) therapy tends to be associated with various complications including engraftment failure, regimen-related toxicities, and infectious diseases. In addition, HC infusion itself occasionally elicits adverse events (AEs), one of the most common AEs is an allergic reaction. As appropriate laboratory tests have not yet been established to distinguish allergy-mediated AEs from other complications, clinical responses for HCT-related AEs can only be nonspecific. In this pilot study, using passive immune basophil activation test (pi-BAT), we attempted to distinguish an HC infusion-induced allergic reaction from various HCT-related AEs. MATERIALS AND METHODS: Using pi-BAT, we examined 34 patients who underwent HCT, that is, 11 with AEs and 23 without AEs as controls. RESULTS: Two of the eleven AE cases were pi-BAT positive and, the rest of nine AE cases were negative, while all non-AE cases were negative. Both of the two positive cases showed erythema, tachycardia, plus cough. Because erythema is one of the representative symptom of allergy, those cases could be classified as allergic reaction cases or anaphylaxis cases if tachycardia and cough were concomitant symptoms of erythema. Among the nine AEs with pi-BAT negative result, four cases showed urticaria, four showed vomiting plus diarrhoea, and one showed cough. Urticaria case was strongly suspected of allergy, however, the AE cases were pi-BAT negative. CONCLUSION: The pi-BAT may be useful as an auxiliary diagnostic tool to confirm the possible involvement of HC infusion in HCT-related AEs and identify an immunologic mechanism for HCT-related hypersensitivity reactions.


Asunto(s)
Anafilaxia , Trasplante de Células Madre Hematopoyéticas , Prueba de Desgranulación de los Basófilos , Basófilos , Humanos , Inmunoglobulina E , Proyectos Piloto , Pruebas Cutáneas
8.
Transfusion ; 61(3): 738-743, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33166416

RESUMEN

BACKGROUND: Alloantibodies against human platelet antigen (HPA)-15 are sometimes detected in patients with platelet transfusion refractoriness (PTR); however, little is known about their impact on PTR. STUDY DESIGN AND METHODS: Two patients who possessed HPA-15 alloantibodies (Patient 1, anti-HPA-15b; Patient 2, anti-HPA-15a) and human leukocyte antigen (HLA) antibodies were enrolled. The efficacy of HPA-15-compatible vs -incompatible platelet transfusion was compared by focusing on ABO- and HLA-matched transfusions on the basis of the 24-hour corrected count increment (CCI-24 hours) for platelets. The titers of HPA-15 antibodies in the patients' sera were also monitored. RESULTS: The patients received 71 and 12 ABO-compatible, HLA-matched platelet transfusions, respectively, during the monitoring periods. Among these transfusions, CCI-24 hours could be calculated in 27 and 10 transfusions, respectively, and the HPA-15 genotype of the donors was determined. There were no significant differences in the CCI-24 hours between the HPA-15 compatible and incompatible transfusions in both patients (P = .30 and .56, respectively, Mann-Whitney U test). There was no significant change in the HPA-15b antibody titer in Patient 1 during the monitoring period, while the HPA-15a antibody level in Patient 2 was undetectable at the end of the monitoring period, although the titer was low at the beginning. CONCLUSION: The efficacy of HPA-15-incompatible platelet transfusions was not necessarily inferior to that of HPA-15 compatible ones. Although the case number was limited, our results suggest that HPA-15 antibodies do not have a significant impact on the effects of platelet transfusion.


Asunto(s)
Antígenos CD/inmunología , Antígenos de Plaqueta Humana/inmunología , Isoanticuerpos/sangre , Leucemia Mieloide Aguda/inmunología , Síndromes Mielodisplásicos/inmunología , Proteínas de Neoplasias/inmunología , Transfusión de Plaquetas , Anciano , Antígenos CD/sangre , Incompatibilidad de Grupos Sanguíneos , Femenino , Proteínas Ligadas a GPI/sangre , Proteínas Ligadas a GPI/inmunología , Humanos , Isoanticuerpos/inmunología , Japón , Leucemia Mieloide Aguda/sangre , Masculino , Persona de Mediana Edad , Síndromes Mielodisplásicos/sangre , Proteínas de Neoplasias/sangre , Proyectos Piloto , Transfusión de Plaquetas/efectos adversos , Estadísticas no Paramétricas
9.
Br J Haematol ; 191(5): 920-926, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32705675

RESUMEN

The Kg-antigen was first discovered in an investigation of a mother whose infant had haemolytic disease of the newborn (HDN). The antibody against the Kg-antigen is believed to be responsible for HDN. The Kg-antigen is provisionally registered under the number 700045, according to the Red Cell Immunogenetics and Blood Group Terminology. However, the molecular nature of the Kg-antigen has remained a mystery for over 30 years. In this study, a monoclonal antibody against the Kg-antigen and the recombinant protein were developed that allowed for the immunoprecipitation analysis. Immunoprecipitants from the propositus' red blood cell ghosts were subjected to mass spectrometry analysis, and DNA sequence analysis of the genes was also performed. A candidate for the Kg-antigen was molecularly isolated and confirmed to be a determinant of the Kg-antigen by cell transfection and flow cytometry analyses. The Kg-antigen and the genetic mutation were then screened for in a Japanese population. The molecular nature of the Kg-antigen was shown to be RhAG with a Lys164Gln mutation. Kg phenotyping further clarified that 0.22% of the Japanese population studied was positive for the Kg-antigen. These findings provide important information on the Kg-antigen, which has been clinically presumed to give rise to HDN.


Asunto(s)
Eritroblastosis Fetal/genética , Membrana Eritrocítica/genética , Isoantígenos/genética , Mutación Missense , Sistema del Grupo Sanguíneo Rh-Hr/genética , Sustitución de Aminoácidos , Eritroblastosis Fetal/metabolismo , Membrana Eritrocítica/metabolismo , Femenino , Humanos , Recién Nacido , Masculino , Sistema del Grupo Sanguíneo Rh-Hr/metabolismo
10.
Transfusion ; 60(11): 2702-2713, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32710598

RESUMEN

BACKGROUND: Antibodies against human platelet antigens (HPAs) cause thrombocytopenias. It is thus important to know the frequency of "b" allotypes in each HPA system for the diagnosis and treatment of anti-HPA antibody-mediated thrombocytopenia. STUDY DESIGN AND METHODS: Genomic DNA was extracted from peripheral blood cells obtained from 2170 blood donors in Japan and was subjected to high-resolution melt (HRM) analysis using polymerase chain reaction for each of the HPA genes, using 23 primer pairs. For genotyping, the resulting amplicons were classified based on their HRM curves. In some cases, direct sequence analysis was performed after HRM analysis to determine nucleotide substitutions. In cases where amino acid substitutions were predicted, protein expression levels were examined in a cell line using 293T cells. RESULTS: The frequencies of each of the HPA-b genotypes were as follows: HPA-1b, 0.4%; HPA-2b, 11.8%; HPA-3b, 41.3%; HPA-4b, 0.8%; HPA-5b, 4.3%; HPA-6b, 1.9%; HPA-15b, 48.8%; HPA-21b, 0.6%; and "b" allotype in the other HPA systems, 0.0%. Twenty-eight variants were found; nine of them were predicted to cause amino acid substitution. However, expression analysis revealed that they did not affect protein expression levels on the cell surface. CONCLUSION: Nine HPA systems are of primary importance in Japan in potentially triggering thrombocytopenia via the HPA antibodies. Similar studies in other countries or races, together with ours, could provide basic information for clinicians in multiethnic societies.


Asunto(s)
Antígenos de Plaqueta Humana , Donantes de Sangre , Regulación de la Expresión Génica , Técnicas de Genotipaje , Reacción en Cadena de la Polimerasa , Antígenos de Plaqueta Humana/biosíntesis , Antígenos de Plaqueta Humana/genética , ADN/genética , Femenino , Humanos , Japón , Masculino , Desnaturalización de Ácido Nucleico
11.
Vox Sang ; 115(2): 159-166, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31769038

RESUMEN

BACKGROUND AND OBJECTIVES: Although HLA-eliminated platelets can facilitate transfusions to patients possessing HLA antibodies, no such products are currently available commercially perhaps because the platelet collection rate is not yet economically viable. We have improved this process' efficiency by employing a hollow-fibre system at the last step of the production process after an acid and a reaction buffer have been washed out conventionally by centrifugation. MATERIALS AND METHODS: HLA-eliminated platelets were prepared via four distinct steps: chilled on ice, treated with an acid solution, diluted and finally washed using the hollow-fibre system. The efficiency of this platelet recovery process was determined. The resulting products' platelet characteristics, including a capacity for HLA expression, were evaluated in vitro and compared in detail to their corresponding originals. RESULTS: The average efficiency of platelet recovery was 91%. Although the expression levels of CD62P, a molecular marker for platelet activation, were approximately threefold higher on new platelets than on the original platelets, their HLA expression levels were lower. The phagocytosis assay, with monoclonal antibodies and cognate HLA antibody-containing sera, suggested that HLA-ABC molecules on the cell surface were sufficiently removed. The platelet functions, including the agonist-induced aggregability and adherence/aggregability of the collagen-coated plates under certain conditions, were conserved and not significantly different from the original ones. CONCLUSION: We propose a novel preparation system for producing HLA-eliminated platelets without centrifugation, which ensures a highly efficient, and therefore, much more economical method of platelet recovery that also retains their key functionality.


Asunto(s)
Plaquetas/citología , Separación Celular/métodos , Anticuerpos Monoclonales/inmunología , Plaquetas/inmunología , Separación Celular/instrumentación , Separación Celular/normas , Centrifugación/efectos adversos , Antígenos HLA/inmunología , Humanos , Selectina-P/genética , Selectina-P/metabolismo , Activación Plaquetaria
12.
Mol Cell ; 47(5): 694-706, 2012 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-22864114

RESUMEN

During prometaphase, dense microtubule nucleation sites at centrosomes form robust spindles that align chromosomes promptly. Failure of centrosome maturation leaves chromosomes scattered, as seen routinely in cancer cells, including myelodysplastic syndrome (MDS). We previously reported that the Miki (LOC253012) gene is frequently deleted in MDS patients, and that low levels of Miki are associated with abnormal mitosis. Here we demonstrate that Miki localizes to the Golgi apparatus and is poly(ADP-ribosyl)ated by tankyrase-1 during late G2 and prophase. PARsylated Miki then translocates to mitotic centrosomes and anchors CG-NAP, a large scaffold protein of the γ-tubulin ring complex. Due to impairment of microtubule aster formation, cells in which tankyrase-1, Miki, or CG-NAP expression is downregulated all show prometaphase disturbances, including scattered and lagging chromosomes. Our data suggest that PARsylation of Miki by tankyrase-1 is a key initial event promoting prometaphase.


Asunto(s)
Proteínas de Ciclo Celular/metabolismo , Centrosoma/metabolismo , Poli Adenosina Difosfato Ribosa/metabolismo , Proteínas/metabolismo , Tanquirasas/metabolismo , Proteínas de Ciclo Celular/química , Células Cultivadas , Centrosoma/química , Aparato de Golgi/química , Aparato de Golgi/metabolismo , Células HEK293 , Células HeLa , Humanos , Huso Acromático/química , Huso Acromático/metabolismo
13.
Transfusion ; 59(11): 3308-3313, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31587279

RESUMEN

BACKGROUND: The basophil activation test (BAT), performed with patient blood samples and supernatants from transfused blood, was developed to elucidate the mechanistic relationship between transfusion and the resultant allergic transfusion reactions (ATRs). This test cannot be performed on myelosuppressed patients and neonates because of the absence of basophils. Therefore, we devised the passive immune basophil activation test (pi-BAT) using patients' plasma and residual transfused blood as sources of immunoglobulin E and allergen, respectively, and the basophils of healthy volunteers served as a source of the responder cells. The sensitivity and specificity of the pi-BAT, however, remained largely unknown. STUDY DESIGN AND METHODS: In this study, the pi-BAT was performed on 31 patients with nonhemolytic transfusion reactions including nine non-ATR and 22 ATR (12 mild and 10 moderate-to-severe) cases to examine its sensitivity and specificity. RESULTS: Nine of the 10 cases with moderate-to-severe ATR tested positive, whereas all the non-ATR cases negative, strongly indicating immunoglobulin E and allergens are involved in the pathogenesis underlying the blood transfusion-triggered adverse effects. CONCLUSION: Thus, we propose that pi-BAT can be used to detect moderate-to-severe ATRs and their underlying mechanisms.


Asunto(s)
Basófilos/inmunología , Hipersensibilidad/diagnóstico , Reacción a la Transfusión/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inmunoglobulina E/inmunología , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Tetraspanina 30/análisis , Reacción a la Transfusión/etiología
15.
Cancer Sci ; 107(2): 140-8, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26583567

RESUMEN

Recent strategies for treating CML patients have focused on investigating new combinations of tyrosine kinase inhibitors (TKIs) as well as identifying novel translational research agents that can eradicate CML leukemia-initiating cells (CML-LICs). However, little is known about the therapeutic benefits such CML-LIC targeting therapies might bring to CML patients. In this study, we investigated the therapeutic potential of EW-7197, an orally bioavailable transforming growth factor-ß signaling inhibitor which has recently been approved as an Investigational New Drug (NIH, USA), to suppress CML-LICs in vivo. Compared to TKI treatment alone, administration of TKI plus EW-7197 to CML-affected mice significantly delayed disease relapse and prolonged survival. Notably, combined treatment with EW-7197 plus TKI was effective in eliminating CML-LICs even if they expressed the TKI-resistant T315I mutant BCR-ABL1 oncogene. Collectively, these results indicate that EW-7197 may be a promising candidate for a new therapeutic that can greatly benefit CML patients by working in combination with TKIs to eradicate CML-LICs.


Asunto(s)
Compuestos de Anilina/farmacología , Protocolos de Quimioterapia Combinada Antineoplásica/farmacología , Leucemia Mielógena Crónica BCR-ABL Positiva/patología , Triazoles/farmacología , Animales , Proliferación Celular/efectos de los fármacos , Modelos Animales de Enfermedad , Humanos , Imidazoles/administración & dosificación , Ratones , Ratones Endogámicos C57BL , Inhibidores de Proteínas Quinasas/administración & dosificación , Proteínas Serina-Treonina Quinasas/antagonistas & inhibidores , Piridazinas/administración & dosificación , Receptor Tipo I de Factor de Crecimiento Transformador beta , Receptores de Factores de Crecimiento Transformadores beta/antagonistas & inhibidores , Transfección , Factor de Crecimiento Transformador beta/antagonistas & inhibidores
16.
Mol Genet Metab ; 118(1): 9-14, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26947917

RESUMEN

BACKGROUND: Since the first case was detected in 2000, there has been a remarkable increase in Japanese patients diagnosed with medium-chain acyl-CoA dehydrogenase (MCAD) deficiency. Genetic analysis has revealed a spectrum of mutations that is quite different from those observed in Caucasian populations. In 2014, Japan initiated nationwide newborn screening (NBS) for MCAD using tandem mass spectrometry (MS/MS). It is an urgent issue to assess the risk of acute metabolic decompensation from the respective novel mutations found thus far. METHODS: To evaluate the pathogenic effect of each mutation, we established a eukaryotic cell expression system and prepared 11 mutant proteins identified in five symptomatic patients and eight MS/MS-NBS-positive newborns, as well as two common Caucasian mutations, p.K329E (c.985G>A) and p.Y67H (c.157C>T) for comparison. RESULTS: The expression of four mutant proteins (p.Q45R, p.P92L, p.P128X and p.Y397N) were severely impaired, whereas the others expressed normally, as did p.K329E and p.Y67H. Based on their dehydrogenase activities toward n-octanoyl-CoA, we determined three mutations (p.R53C, p.R281S and p.G362E) to be disease-causing, two mutations having (p.R17H and p.M274V) to be of marginal risk, and two mutations (p.K271E and p.I416T) as benign. Their allele-specific activities were as a whole in accordance with those estimated from the results of measurement in peripheral blood mononuclear cells. CONCLUSION: As most of the mutations detected in the Japanese population are unique, prudent genetic and enzymatic analysis is essential to precisely evaluate the latent risk of clinical onset for screening-positive newborns.


Asunto(s)
Acil-CoA Deshidrogenasa/deficiencia , Acil-CoA Deshidrogenasa/genética , Acil-CoA Deshidrogenasa/metabolismo , Errores Innatos del Metabolismo Lipídico/diagnóstico , Mutación , Tamizaje Neonatal/métodos , Espectrometría de Masas en Tándem/métodos , Pueblo Asiatico/genética , Femenino , Predisposición Genética a la Enfermedad , Humanos , Lactante , Recién Nacido , Japón , Errores Innatos del Metabolismo Lipídico/etnología , Errores Innatos del Metabolismo Lipídico/genética , Masculino , Población Blanca/genética
19.
J Clin Immunol ; 35(5): 512-6, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25912133

RESUMEN

PURPOSE: To confirm and characterize mosaicism of the cyclic neutropenia (CyN)-related mutation in the ELANE gene identified in the asymptomatic mother of patients with CyN. METHODS: We identified sibling cases with CyN due to a novel heterozygous splicing site mutation, IVS4 +5SD G>T, in the ELANE gene, resulting in an internal in-frame deletion of 30 nucleotides (corresponding to a ten amino acid deletion, V161-F170). The mutated allele was also detected in their asymptomatic mother but at low frequency. We measured the frequency of the mutant allele from peripheral blood leukocytes (PBLs) by subcloning, and confirmed the allelic frequency of mosaicism in various cell types by massively parallel DNA sequencing (MPS) analysis. RESULTS: In the subcloning analysis, the mutant allele was identified in 21.36 % of PBLs from the asymptomatic mother, compared with 54.72 % of PBLs from the CyN patient. In the MPS analysis, the mutant allele was observed in approximately 30 % of mononuclear cells, CD3(+) T cells, CD14(+) monocytes and the buccal mucosa. Conversely, it was detected in low frequency in polymorphonuclear leukocytes (PLMLs) (3-4 %) and CD16(+) granulocytes (2-3 %). CONCLUSIONS: Mosaicism of the ELANE mutation has only previously been identified in one confirmed and one unconfirmed case of SCN. This is the first report of mosaicism of the ELANE mutation in a case of CyN. The MPS results suggest that this de novo mutation occurred during the two-cell stage of embryogenesis. PLMLs expressing the ELANE mutation were found to be actively undergoing apoptosis.


Asunto(s)
Elastasa de Leucocito/genética , Monocitos/fisiología , Neutropenia/diagnóstico , Eliminación de Secuencia/genética , Linfocitos T/fisiología , Adulto , Enfermedades Asintomáticas , Desarrollo Embrionario/genética , Femenino , Frecuencia de los Genes , Humanos , Receptores de Lipopolisacáridos/metabolismo , Masculino , Mosaicismo , Madres , Mucosa Nasal/fisiología , Neutropenia/genética , Linaje , Hermanos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda