Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 83-88, 2022 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-35165472

RESUMEN

OBJECTIVE: To investigate the effect of a noval radio-frequency atmospheric-pressure glow discharge (RF-APGD) plasma jet on crosslinking of dentin collagen. METHODS: (1) Twenty intact third molars were collected. The middle dentin discs were prepared for each tooth by low-speed water-cooled Isomet saw, and then immersed in 10% (mass fraction) H3PO4 solution for 16 h to obtain fully demine-ralized dentin collagen. The twenty dentin discs were then randomly divided into five groups. The control group was untreated while the four experimental groups were treated by plasma jet with gas temperature of 4 ℃ for different times (20 s, 30 s, 40 s, and 50 s). The structure and crosslinking degree of dentin collagen were characterized by attenuated total reflection-Fourier transform infrared spectroscopy. The surface morphology of demineralized dentin was observed by scanning electron microscope, and the microstructure was observed by transmission electron microscope. (2) Fourty non-caries third molars were collected to prepare 5 g fine dentin powder, then completely demineralized with 10% H3PO4 solution. The control group was untreated, while the four experimental groups were treated by plasma jet for 20 s, 30 s, 40 s and 50 s. The crosslinking degree of each group was determined by ninhydrin colorimetric method. (3) Forty intact third molars were collected to obtain dentin strips. Only two central symmetrical dentin strips (nasty 80) were taken from each tooth and immersed in 10% H3PO4 solution for 16 h to obtain fully demineralized dentin collagen. Eighty dentine collagen fiber strips were randomly divided into five groups. The control group was untreated and the axial surfaces of dentin collagen fiber strips in the expe-rimental groups were treated with the plasma jet for 20 s, 30 s, 40 s and 50 s. The ultimate tensile strength of dentin was measured by universal mechanical machine. RESULTS: (1) The surface morphology of demineralized dentin observed by scanning electron microscope showed that the network structure of collagen fibers on the surface of demineralized dentin treated with the plasma jet for 20 s, 30 s and 40 s could maintain the uncollapsed three-dimensional structure, and part of the microstructure was destroyed after plasma jet treated for 50 s. After being treated by plasma jet for 20 s, 30 s and 40 s, the three-dimensional structure was uncollapsed, and the typical periodic transverse pattern of natural type Ⅰ collagen fiber could be seen. The results of infrared spectra showed that the secondary conformation of dentin collagen fibers was the same as that of the control group after being treated with the plasma jet, and the intensity of amide band was significantly increased after being treated for 30 s and 40 s. (2) The results of ninhydrin crosslinking test showed that the crosslinking ratio of dentin collagen treated by plasma jet for 30 s and 40 s was the highest, and the difference was statistically significant (P < 0.05). (3) The results of dentin ultimate tensile strength showed that the control group was (1.67±0.24) MPa, and the plasma jet treated 20 s, 30 s, 40 s and 50 s groups were (4.21±0.15) MPa, (7.06±0.30) MPa, (7.32±0.27) MPa, and (6.87±0.17) MPa, which were significantly different from that of the control group (P < 0.05). CONCLUSION: The novel RF-APGD plasma jet treatment can promote the crosslinking degree of demineralized dentin collagen and improve their ultimate tensile strength.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Colágeno , Dentina , Microscopía Electrónica de Rastreo , Resistencia a la Tracción
2.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 140-145, 2022 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-35165481

RESUMEN

OBJECTIVE: To analyze the marginal roughness and marginal fitness of chairside computer-aided design and computer-aided manufacturing (CAD/CAM) laminate veneers with different materials and thicknesses, and to provide a reference for the clinical application of laminate veneers. METHODS: The butt-to-butt type laminate veneers were prepared on resin typodonts, the preparations were scanned, and the laminate veneers were manufactured by chairside CAD/CAM equipment. The laminate veneers were divided into four groups (n=9) according to the materials (glass-matrix ceramics and resin-matrix ceramics) and thickness (0.3 mm and 0.5 mm) of the veneers, with a total of 36. The marginal topo-graphies of each laminate veneer were digitally recorded by stereomicroscope, and the marginal rough-nesses of the laminate veneers were determined by ImageJ software. The marginal fitness of the laminate veneers was measured by a fit checker and digital scanning and measuring method. At the same time, the mechanical properties of glass-matrix ceramic and resin-matrix ceramic bars (n=20) were tested by a universal testing device. RESULTS: The marginal roughness of 0.3 mm and 0.5 mm glass-matrix ceramic laminate veneers was (24.48±5.55) µm and (19.06±5.75) µm, respectively, with a statistically significant difference (P < 0.001). The marginal roughness of 0.3 mm and 0.5 mm resin-matrix ceramic laminate veneers was (6.13±1.27) µm and (6.84±2.19) µm, respectively, without a statistically significant difference (P>0.05). The marginal roughness of the glass-matrix ceramic laminate veneers was higher than that of the resin-matrix ceramic laminate veneers with a statistically significant difference (P < 0.001). The marginal fitness of 0.3 mm and 0.5 mm glass-matrix ceramic laminate veneers were (66.30±26.71) µm and (85.48±30.44) µm, respectively. The marginal fitness of 0.3 mm and 0.5 mm resin-matrix ceramic laminate veneers were (56.42±19.27) µm and (58.36±8.33) µm, respectively. There was no statistically significant difference among the 4 groups (P>0.05). For glass-matrix ceramics, the flexural strength was (327.40±54.25) MPa, the flexural modulus was (44.40±4.39) GPa, and the modulus of resilience was (1.24±0.37) MPa. For resin-matrix ceramics, the flexural strength was (173.71±16.61) MPa, the flexural modulus was (11.88±0.51) GPa, and the modulus of resilience was (1.29±0.27) MPa. The flexural strength and modulus of glass-matrix ceramics were significantly higher than those of resin-matrix ceramics (P < 0.001), but there was no statistically significant difference in the modulus of resilience between the two materials (P>0.05). CONCLUSION: The marginal roughness of CAD/CAM glass-matrix ceramic laminate veneers is greater than that of resin-matrix ceramic laminate veneers, but there was no statistically significant difference in marginal fitness among them. Increasing the thickness can reduce the marginal roughness of glass-matrix ceramic laminate veneers, but has no effect on the marginal roughness of resin-matrix ceramic laminate veneers.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Porcelana Dental , Coronas con Frente Estético , Ensayo de Materiales , Propiedades de Superficie
3.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(5): 977-982, 2021 Oct 18.
Artículo en Zh | MEDLINE | ID: mdl-34650305

RESUMEN

OBJECTIVE: To evaluate the morphology accuracy of direct occlusal veneer using two types of modified stamp-technique, comparing the Results of two types of stamp and different composite resin. METHODS: Model scanner was used to get the original data from the standard resin teeth in plastic model. Two types of stamps were made: solid silicon stamp and transparent silicon stamp. In the study, 54 resin tooth were randomly divided into 9 groups: Groups 1-8 were restored by direct composite resin, using general and bulk-filled composite resin in occlusal veneer (1 mm or 2 mm) with two types of stamp-technique (the solid silicon, and the transparent silicon), and the control group was restored by indirect way using CAD/CAM composite resin restoration by biocopy technique to mimic the original shape of the teeth. After the resin teeth were prepared for occlusal veneer, the direct and indirect composite resins were restored. After the restoration was finished, the data were obtained again by the same model scanner in the plastic model. 3D comparisons were made using the original and restoration data, the average difference and the root mean square of difference (RMS) were recoded from the software. The RMS of all the groups were analyzed using one way ANOVA (α=0.05). RESULTS: The RMS of occlusal surface in solid silicon stamp group was (0.136±0.031) mm, in transparent silicon group was (0.130±0.024) mm, and in control group was (0.130±0.009) mm. There were no significant difference. While the RMS of buccal/lingual surface in solid silicon stamp group was the smallest [(0.135±0.020) mm, P < 0.05], and in transparent silicon group it was (0.147±0.021) mm, and control group (0.153±0.014) mm. The general composite resin using the two types of stamp had the largest occlusal RMS in 2 mm occlusal veneer, which were significantly larger than control group (P < 0.05). CONCLUSION: The direct occlusal veneer using two types of modified "stamp-technique" had relatively good morphology accuracy. Direct occlusal veneer using bulk-filled composite resin made with two types of stamp technique had even more accurate morphology than using general composite resin. The solid silicon stamp had a better morphology accuracy in buccal/lingual surface than the transparent silicon stamp.


Asunto(s)
Fracturas de los Dientes , Diente , Resinas Compuestas , Diseño Asistido por Computadora , Restauración Dental Permanente , Humanos , Ensayo de Materiales
4.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(3): 594-597, 2021 Jun 18.
Artículo en Zh | MEDLINE | ID: mdl-34145867

RESUMEN

OBJECTIVE: To observe the movement of posterior teeth after losing the interproximal and occlusal contacts in adults from the amount and speed of mesial-distal, buccal-lingual, occlusal-gingival and three-dimensional movements. METHODS: Twenty cases of metal post-core restoration from the Department of Prosthodontics, Peking University School and Hospital of Stomatology were recruited into this study, which was an observational study. The restored teeth had complete mesial, distal, and occlusal contacts before treatment. All the interproximal and occlusal contacts were removed during the preparation for the post-core. The three-dimensional positions of the post-core preparation were obtained by the intraoral scanner at the day of tooth preparation and that of post-core placement. The amounts of mesial-distal, buccal-lingual and occlusal-gingival tooth movement were measured in the software. On this basis, the amount of three-dimensional tooth movement was calculated. The speed of tooth movement was calculated based on the elapsed time between the two scans. RESULTS: Ten females and ten males with an average age of (29.5±4.9) years were recruited. The average elapsed time was (10.9±2.7) days. The amount of the mesial-distal tooth movement was (134.8±61.2) µm, of the buccal-lingual tooth movement was (110.3±39.5) µm, of the occlusal-gingival tooth movement was (104.8±57.5) µm, and of the three-dimensional tooth movement was (211.4±71.0) µm, respectively. The amounts of mesial-distal, buccal-lingual and three-dimensional tooth movements were larger in female than in male (P < 0.05). The speed of the mesial-distal tooth movement was (13.1±7.8) µm/d, of the buccal-lingual tooth movement was (10.6±4.5) µm/d, of the occlusal-gingival tooth movement was (10.1±6.8) µm/d, and of the three-dimensional tooth movement was (20.5±9.7) µm/d, respectively. The speed of mesial-distal and buccal-lingual tooth movements were larger in female than in male (P < 0.05). The speed of three-dimensional tooth movement was slightly larger in female than in male, while there was no significant difference between different genders (P>0.05). CONCLUSION: The three-dimensional position of posterior teeth changed after losing the interproximal and occlusal contacts in adults. The female had more significant and faster tooth movement than the male.


Asunto(s)
Diente , Adulto , Femenino , Humanos , Masculino , Programas Informáticos , Técnicas de Movimiento Dental , Adulto Joven
5.
Beijing Da Xue Xue Bao Yi Xue Ban ; 52(6): 1130-1134, 2020 Dec 18.
Artículo en Zh | MEDLINE | ID: mdl-33331326

RESUMEN

OBJECTIVE: To analyze the esthetic proportions of maxillary anterior teeth in term of the apparent widths proportion of the adjacent teeth and width/height ratio of the clinical crown in 120 Chinese adults. METHODS: Maxillary gypsum casts were obtained from the dental laboratories of stomatological hospitals in North China, Southeast China, and Southwest China, according to the inclusion criteria and exclusion criteria. Standardized digital photographs of each cast were recorded. The apparent widths and actual widths and heights of the central incisors, lateral incisors and canines were determined by ImageJ software for the calculation of apparent widths proportion of the adjacent teeth and width/height ratio of the clinical crown. The ideal apparent widths proportion (Golden proportion and Preston proportion) and width/height ratio (0.80) were tested. The gender, arch side, and regional differences were investigated. RESULTS: The apparent widths proportion of the lateral/central incisor was 0.724±0.047, of the canine/lateral incisor was 0.814±0.092. The width/height ratio of the central incisor was 0.848±0.072, of the lateral incisor was 0.834±0.094, of the canine was 0.883±0.098. The esthetic proportions were different from the predicted ideal ratio (P < 0.001). The apparent widths proportion of lateral/central incisor was significantly larger in the right side than that in the left side (0.730± 0.044 vs. 0.718±0.050), and was significantly smaller in North China than that in Southwest China (0.711±0.051 vs. 0.731±0.044). The width/height ratio of the central incisor was significantly larger in the female than that in the male (0.855±0.074 vs. 0.835±0.068), and in the right side than that in the left side (0.855±0.073 vs. 0.842±0.072). The width/height ratio of the lateral incisor was significantly larger in the female than that in the male (0.843±0.097 vs. 0.817±0.084). CONCLUSION: The apparent widths proportion of adjacent teeth and the width/height ratio of the clinical crown in Chinese adults are different from the foreigner's. The esthetic proportion parameters have significant population specificity, and the measurements cannot be generalized as well as it should be applied with caution.


Asunto(s)
Diente Canino , Corona del Diente , Adulto , Pueblo Asiatico , China , Estética , Estética Dental , Femenino , Humanos , Masculino , Maxilar/anatomía & histología , Odontometría , Corona del Diente/anatomía & histología
6.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(2): 390-395, 2020 Dec 30.
Artículo en Zh | MEDLINE | ID: mdl-33879916

RESUMEN

OBJECTIVE: To investigate the blood pressure and heart rate changes and influencing factors during single dental implant surgery. METHODS: A retrospective cohort study was conducted. Six hundred and forty cases underwent single dental implant placement in Department of Prosthodontics, Peking University School and Hospital of Stomatology from January 2016 to December 2016 were recruited in this study according to the inclusion and exclusion criteria. They were divided into different groups according to the exposure factors which were patient characteristics (gender, age) and surgical procedures (immediate placement, flap elevation, bone grafting). The correlation between blood pressure and heart rate variability during single dental implant surgery and the patient characteristics and surgical procedures were analyzed. RESULTS: The average systolic blood pressure variability was 9.47%±6.45% (maximum 46.04%), the average diastolic blood pressure variability was 12.18%±9.39% (maximum 88.00%), and the average heart rate variability was 10.59%±7.68% (maximum 49.12%). The effects of age and bone grafting on blood pressure variability, and of gender and immediate placement on heart rate variability, were statistically significant (P < 0.05), respectively. The incidence of abnormal intraoperative blood pressure rise was 4.69%, of which there were 4 cases (0.63%) of systolic blood pressure ≥180 mmHg and/or diastolic blood pressure ≥110 mmHg. The incidence of abnormal intraoperative heart rate rise was 6.72%. Hierarchical analysis showed a higher risk of abnormal intraoperative blood pressure rise in the elderly (≥60 years) male patients [P < 0.05, RR=3.409 (95%CI: 1.155-10.062) ] and flap elevation with bone grafting cases [P < 0.05, RR=2.382 (95%CI: 1.126-5.040)], respectively. There was no statistically significant association between abnormal heart rate rise and patient characteristics or surgical procedures (P>0.05). CONCLUSION: There was a certain risk of blood pressure and heart rate variability during dental implant surgery. Elderly male patients and flap elevation with bone grafting were risk factors of abnormal intraoperative blood pressure rise.


Asunto(s)
Implantes Dentales , Anciano , Presión Sanguínea , Implantación Dental Endoósea , Frecuencia Cardíaca , Humanos , Masculino , Maxilar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
7.
Beijing Da Xue Xue Bao Yi Xue Ban ; 52(5): 948-951, 2020 Oct 18.
Artículo en Zh | MEDLINE | ID: mdl-33047735

RESUMEN

OBJECTIVE: To assess the effects of loupes and microscope on the posture of prosthodontists when preparing the laminate veneer, and to assess the clinical value of loupes and microscope from the ergonomic aspects. METHODS: Twenty young prosthodontists from Department of Prosthodontics, Peking University School and Hospital of Stomatology were recruited into this study, which was a prospective, single blind, self-control trials. The research hypothesis was concealed and the participants were deceived about the precise purpose of the study to counterbalance the lack of direct blinding. The prosthodontists prepared laminate veneers of open window type in the artificial dental model, under routine visual field (control group), 2.5× headwear loupes (loupes group), and 8× operating microscope (microscopic group) by turning. The participants were photographed from profile view and front view. Thereafter, the subjective assessment was performed by themselves using the visual analogue score (VAS). The expert assessment was performed by two professors using modified-dental operator posture assessment instrument on the basis of photographs of the profile view and front view. RESULTS: The subjective assessment scores for the control group, loupes group and microscopic group were 4.55±1.96, 7.90±1.12, and 9.00±0.92, respectively. There was significant difference between the three groups' subjective scores (P < 0.05). The expert assessment scores for the control group, loupes group and microscopic group were 16.38±1.52, 15.15±1.30, and 13.60±0.88, respectively. There was significant difference between the three groups' expert assessment scores (P < 0.05). Specifically, the three groups' expert assessment scores were significantly different (P < 0.05) in trunk position (front to back) (1.33±0.41, 1.03±0.11, 1.00±0.00), head and neck position (front to back) (2.75±0.38, 2.13±0.36, 1.23±0.38), elbows level (1.38±0.43, 1.40±0.45, 1.13±0.22), and shoulders level (1.43±0.41, 1.23±0.34, 1.13±0.28). Thereinto, the microscopic group was better than loupes group in head and neck position (front to back) and elbows level (P < 0.05). CONCLUSION: Loupes and microscope improve the posture of the prosthodontist when preparing the laminate veneer, in which the microscope is better than loupes. Therefore, the magnification devices have clinical value from the ergonomic aspects.


Asunto(s)
Ergonomía , Postura , Odontólogos , Humanos , Estudios Prospectivos , Método Simple Ciego
8.
Beijing Da Xue Xue Bao Yi Xue Ban ; 51(2): 315-320, 2019 Apr 18.
Artículo en Zh | MEDLINE | ID: mdl-30996375

RESUMEN

OBJECTIVE: To evaluate the effect of different cold atmospheric plasma (CAP) treatment on the surface chemical and physical properties of zirconia and adhensive behaviour of human gingival fibroblasts (HGFs) cultured on zirconia disks. METHODS: The zirconia disks were divided into four groups and treated using helium, argon and mixture of argon and oxygen cold atmospheric plasma for 90 s or left untreated. The surface morphology, wettability and chemical elements were analyzed right after treatment. Human gingival fibroblasts were grown from biopsies obtained from a periodontally healthy human subject during periodontal surgery. HGFs were seeded on zirconia disk, and cells density was measured at the time point of 3 hours. Indirect immunofluorescence (IIF) was performed for morphometric examination at the time point of 3 hours. RESULTS: The crystallographic structure of zirconia was analyzed previously and the results suggested that it fitted the properties of zirconium yttrium oxide. After helium, argon and mixture of argon and oxygen cold atmospheric plasma treatment, the surface morphology and roughness of zirconia disks remained the same. The contact angle of zirconia decreased significantly(P<0.05)after CAP treatment: from 68.38° to 17.90°. After different CAP plasmas treatment, the atomic percentage of carbon on the outermost surface of the three groups decreased, as did the surface C/O ratio. The surface C/O ratio of zirconia decreased from 1.07 to 0.33. Fibroblasts density increased on CAP treated disks, especially the ones treated by mixture of argon and oxygen CAP(P<0.05). Cells of the three CAP plasma treatment groups spread better and had more protrusions, as well as larger surficial areas. CONCLUSION: Based on the results of this study after being treated by different kinds of CAP plasmas for 90 s, the surface wettability increased and the elements changed significantly with no changes in the tomography and roughness of the materials. The CAP treatment enhances the adhensive behavior of fibroblasts on zirconia by increasing the oxygen functional groups and promoting the cell density. Wettability of zirconia, an important physicochemical property, has a vital influence on the cell behaviors.


Asunto(s)
Encía , Circonio , Fibroblastos , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
9.
Beijing Da Xue Xue Bao Yi Xue Ban ; 51(1): 43-48, 2019 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-30773542

RESUMEN

OBJECTIVE: To investigate the effect of different treatment temperatures of a novel cold atmospheric plasma jet treatment on the resin-dentin bonding. METHODS: (1) Fifty-two freshly extracted, non-carious and intact third molars were collected. The occlusal one-third of the crown was removed by means of a water-cooled low-speed Isomet saw. One dentin disc [(900 ±100) µm] was prepared for each tooth. The fifty-two dentin discs were randomly divided into control group and experimental groups, of which four were in control group, and forty-eight were divided into four experimental groups according to the different treatment temperatures (4 °C, 10 °C, 20 °C and 30 °C) of the novel radio-frequency atmospheric-pressure glow discharge (RF-APGD) plasma jet, twelve in each group. Each experimental group was divided into three subgroups according to different treatment time (10 s, 20 s and 30 s), with four in each subgroup. The occlusal one-third of the crown was removed by means of a water-cooled low-speed Isomet saw. The morphology of demineralized dentin surfaces was analyzed using field emission scanning electron microscopy. (2) Twenty unerupted, non-carious and intact third molars were randomly divided into five groups, four in each group: control group, untreated; 4 °C, 10 °C, 20 °C and 30 °C experimental groups, each group was treated with the RF-APGD plasma jet for 20 s. The micro-tensile resin dentin bond strength was tested after 20 s RF-APGD plasma jet treatment with different temperatures, using a universal mechanical machine. RESULTS: (1) The field emission scanning electron microscopy results indicated that when compared with the control group, a 10 s RF-APGD plasma jet treatment with 30 °C and 20 °C collapsed the collagen scaffold. Collagen fibrils maintained an uncollapsed three-dimensional structure after the 4 °C RF-APGD plasma jet treatment for even 30 s treatment. (2) The microtensile resin dentin bond strength results of the 4 °C RF-APGD plasma jet treatment group (57.8±0.7) MPa were significantly higher than that of the control group [(47.4±0.5) MPa] and 10 s, 20 s and 30 s RF-APGD plasma treatment group [(51.9±0.7) MPa,(29.7±1.0) MPa and (22.2±1.5) MPa] with statistically significant difference (P<0.05). Compared with the control group, the micro-tensile bond strength increased about 21.9% and 9.5% after 4 °C and 10 °C RF-APGD plasma jet treatment, respectively. CONCLUSION: Compared with other treatment temperatures, this novel RF-APGD plasma jet treatment with the temperature of 4 °C can preserve the three-dimensional morphology of demineralized dentin better, and can improve the resin-dentin bonding.


Asunto(s)
Recubrimiento Dental Adhesivo , Gases em Plasma , Resinas Compuestas , Dentina , Recubrimientos Dentinarios , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Temperatura , Resistencia a la Tracción
10.
Beijing Da Xue Xue Bao Yi Xue Ban ; 50(1): 53-57, 2018 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-29483722

RESUMEN

OBJECTIVE: To evaluate the effects of different surface treatments on the shear bond strength between zirconia and resin cement. METHODS: Forty zirconia discs were randomly divided into four groups (10 discs in each group) for different surface treatments: control, no surface treatment; sandblast, applied air abrasion with aluminum oxide particles; ultraviolet (UV), the zirconia sample was placed in the UV sterilizer at the bottom of the UV lamp at 10 mm, and irradiated for 48 h; cold plasma, the discs were put in the cold plasma cabinet with the cold plasma generated from the gas of He for 30 s. Specimens of all the groups were surface treated prior to cementation with Panavia F 2.0 cement. The surface morphology and contact angle of water were measured. The shear bond strengths were tested and the failure modes were examined with a stereomicroscope. RESULTS: Surface morphology showed no difference between the UV/cold plasma group and the control group. Sandblasted zirconia displayed an overall heterogeneous distribution of micropores. The contact angle of the control group was 64.1°±2.0°. After sandblasting, UV irradiation and cold plasma exposure, the values significantly decreased to 48.8°±2.6°, 27.1°±3.6° and 32.0°±3.3°. The values of shear bond strength of the specimens with sandblasted (14.82±2.01) MPa were higher than those with no treatment (9.41±1.07) MPa with statistically significant difference (P<0.05). The values of shear bond strength of the specimens with UV irradiation (10.02±0.64) MPa were higher than those with no treatment (9.41±1.07) MPa, but without statistically significant difference (P>0.05). The values of cold plasma group (18.34±3.05) MPa were significantly higher than those of control group (9.41±1.07) MPa, even more than those with sandblast(14.82±2.01) MPa (P<0.05). X-ray photoelectron spectroscopy (XPS) showed increase in oxygen (O) and decrease in carbon (C) elements after UV and cold plasma treatment. The surface C/O ratio also decreased after UV and cold plasma treatment. CONCLUSION: Zirconia specimens treated with UV and cold plasma could significantly improve the hydrophilicity. The surface morphology was unaffected by the UV irradiation and cold plasma treatments. The improvements of ziconia shear bond strength were slight in UV group without statistically significant difference. Cold plasma treatment significantly improved the shear bond strength between zirconia and resin cement.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Distribución Aleatoria , Resistencia al Corte , Propiedades de Superficie , Circonio
11.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(6): 546-550, 2024 Jun 09.
Artículo en Zh | MEDLINE | ID: mdl-38808414

RESUMEN

Dental and facial esthetics is an essential part of modern stomatology. With the development of science and technology and the advancement of interdisciplinary studies, the research of robot technology in the field of dental and facial esthetics is becoming more extensive, and its clinical applications are gradually increasing. This article provides insights into the research and application of robot technology in dental hard tissue esthetics, periodontal soft tissue esthetics, dentition space esthetics, and maxillofacial esthetics. It also highlights the current limitations and development trends and provides references for future research and application of robots in oral esthetics.


Asunto(s)
Estética Dental , Cara , Robótica , Humanos , Cara/anatomía & histología
12.
Trop Med Int Health ; 18(12): 1531-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24118535

RESUMEN

OBJECTIVE: To investigate prevalence and risk factors of syphilis infection among female sex workers (FSWs) in Shenzhen, China. METHODS: Observational study among (2009-2012) 1653 FSWs recruited by venue-based sampling using questionnaire-based interviews for socio-demographics, behaviours and syphilis testing results. Logistic regression was used to assess risk factors of syphilis infection. RESULTS: The overall syphilis prevalence was 4.7%, showing a slightly decreasing trend. Factors significantly associated with syphilis infection were inconsistent condom use (OR = 1.87, P = 0.015), illicit drug use (OR = 5.45, P < 0.001) and older age in years (OR = 1.08, P < 0.001). Venues where FSWs were recruited and duration of commercial sex work were not significantly associated with syphilis infection (P > 0.05). CONCLUSIONS: Syphilis is still common among FSWs in Shenzhen, China. Current comprehensive prevention programmes (e.g. condom promotion and peer education) should be continued to maintain and increase safe sexual practices and to reduce illicit drug use among FSWs. Expanding point-of-care syphilis screening programmes may be an important strategy for early diagnosis. We recommend timely and effective treatment programmes to be linked to such screening programmes.


Asunto(s)
Trabajadores Sexuales/estadística & datos numéricos , Sífilis/epidemiología , Adulto , Factores de Edad , China/epidemiología , Condones/estadística & datos numéricos , Femenino , Humanos , Modelos Logísticos , Prevalencia , Factores de Riesgo , Trastornos Relacionados con Sustancias/complicaciones , Sífilis/etiología , Adulto Joven
13.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(10): 1009-1014, 2022 Oct 09.
Artículo en Zh | MEDLINE | ID: mdl-36266073

RESUMEN

Severely worn dentition seriously affects patient's esthetics and function. Its etiology is complex, differential diagnosis is difficult, treatment process involves multiple disciplines, and requires esthetic and functional rehabilitation. A "8-step sequential treatment" for the rehabilitation of severely worn dentition has been established. In recent years, digital technology has been increasingly applied to the esthetic and functional rehabilitation of severely worn dentition. This article will describe the application of digital methods in the 8-step sequential treatment of severely worn dentition.


Asunto(s)
Desgaste de los Dientes , Humanos , Desgaste de los Dientes/rehabilitación , Estética Dental , Dentición , Tecnología Digital
14.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(4): 418-423, 2022 Apr 09.
Artículo en Zh | MEDLINE | ID: mdl-35368170

RESUMEN

Zirconia is widely used in the field of dentistry because of its superior mechanical and esthetic characteristics. However, the tetragonal zirconia polycrystal restorations commonly used in clinics will degrade at low temperatures in the oral environment, resulting in increased surface roughness, microcracks, and decreased mechanical properties. Low-temperature degradation of zirconia can be affected by grain size, stress, stabilizer content and type, surface treatment, sintering conditions, and other factors. Through a literature review and analysis, this review summarizes the research progress on the low-temperature degradation of zirconia in prosthetic dentistry to provide references for the improvement of zirconia in clinical and research applications.


Asunto(s)
Estética Dental , Prostodoncia , Cerámica , Materiales Dentales , Ensayo de Materiales , Propiedades de Superficie , Temperatura , Itrio/química , Circonio
15.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 57(4): 346-351, 2022 Apr 09.
Artículo en Zh | MEDLINE | ID: mdl-35368160

RESUMEN

Objective: To evaluate the pink and white esthetics of conventional and socket shield technique (SST) immediate implant restoration. Methods: Thirty volunteers were recruited according to preset criteria, and were assigned to 3 groups. Natural teeth group (ten undergraduates or postgraduates from Peking University School and Hospital of Stomatology in January 2020, n=10): all volunteers' maxillary anterior teeth were natural teeth with healthy gingiva, and none of the teeth were restored by crowns or composite. Conventional group and SST group (patients had a maxillary central incisor immediate implant placed in Department of Prosthodontics, Peking University School and Hospital of Stomatology during October 2016 to January 2021, n=10 for each group): the volunteer had an unrestored natural maxillary central incisor, and the contralateral maxillary central incisor was restored by conventional or SST immediate implant placement, temporization and all ceramic final restoration, photos were taken 12 months post-surgery. Three groups of evaluators namely layperson (staff from Second Clinical Division of Peking University School and Hospital of Stomatology and 2 family members, n=10), dental students (class 2015 undergraduates from Peking University School and Hospital of Stomatology, n=10) and prosthodontists (from Department of Prosthodontics, Peking University School and Hospital of Stomatology, n=10) were invited to assess the esthetics using pink esthetic score (PES) and white esthetic score (WES). The results were statistically analyzed. Results: PES and WES of natural teeth group [9(8, 10) and 8(7, 10)] were significantly higher than conventional group [7(6,8) and 7(6,9)] (H=287.08, 132.79,P<0.01) and SST group [7(6, 9) and 8(7, 9)] (H=216.01, 101.21, P<0.01). SST group yielded higher PES than the conventional group (H=-71.06, P<0.01), yet had similar WES (H=-31.57, P>0.05). Dental students had significant lower PES and WES than prosthodontists (H=-120.90, -218.86, P<0.01) and layperson (H=-109.55, 134.97, P<0.01). Prosthodontists and layperson got similar PES (H=-11.36, P>0.05), however yielded different WES (H=-83.89, P<0.01). Conclusions: SST immediate implant placement obtained better pink esthetics than conventional protocol 12-month after implant surgery, profession may have significant impact on evaluators during pink and white esthetic evaluation.


Asunto(s)
Implantes Dentales de Diente Único , Implantes Dentales , Carga Inmediata del Implante Dental , Coronas , Estética Dental , Humanos , Maxilar/cirugía , Resultado del Tratamiento
16.
J Appl Lab Med ; 5(6): 1313-1323, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32717060

RESUMEN

BACKGROUND: Little is known about the performance of the Roche novel severe acute respiratory syndrome coronavirus 2 antibody (anti-SARS-CoV-2) assay. We provide an extensive evaluation of this fully automated assay on Cobas e801/e602 immunoassay analyzers. METHODS: We assessed the linearity, precision, and throughput of the Roche anti-SARS-CoV-2 assay. Sensitivity was calculated from 349 SARS-CoV-2 polymerase chain reaction (PCR) positive samples; specificity was determined from 715 coronavirus disease 2019 (COVID-19)-naive samples. We examined cross-reactivity against other antibody positive samples [syphilis, rheumatoid factor (RF), antinuclear antibody (ANA), double-stranded DNA (ds-DNA), influenza, dengue, hepatitis B (HBV), hepatitis C (HCV)] and the anti-SARS-CoV-2 kinetics. RESULTS: The assay cut-off index (COI) was linear up to 90.8. The interassay precision was 2.9% for a negative control (COI = 0.1) and 5.1% for a positive control (COI = 3.0). Assay time is 18 min and results are available 1 min later; throughput for 300 samples was 76 min. Only 1 case positive for HBsAg tested falsely positive; specificity was 99.9%. The assay has a sensitivity of 97.1% 14 days after PCR positivity (POS) and 100% at ≥21 days POS; 48.2% of cases had anti-SARS-CoV-2 within 6 days POS. In 11 patients in whom serum was available prior to a positive antibody signal (COI ≥1.0) the interval between the last negative and first positive COI (time to "seroconversion") on average is 3 days (range 1-6 days) and 4 more days (range 1-7) for the anti-SARS-CoV-2 to plateau. CONCLUSION: The Roche anti-SARS-CoV-2 assay shows excellent performance with minimal cross-reactivity from other viral and confounding antibodies. Antibody development and seroconversion appears quite early.


Asunto(s)
Anticuerpos Antivirales/sangre , Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/instrumentación , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Pruebas Serológicas/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antivirales/inmunología , Betacoronavirus/genética , Betacoronavirus/inmunología , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/estadística & datos numéricos , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/inmunología , Infecciones por Coronavirus/virología , Reacciones Cruzadas/inmunología , Femenino , Fluoroinmunoensayo/instrumentación , Fluoroinmunoensayo/estadística & datos numéricos , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Mediciones Luminiscentes/instrumentación , Mediciones Luminiscentes/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/sangre , Neumonía Viral/inmunología , Neumonía Viral/virología , Reacción en Cadena de la Polimerasa/estadística & datos numéricos , Valor Predictivo de las Pruebas , ARN Viral/aislamiento & purificación , Juego de Reactivos para Diagnóstico , SARS-CoV-2 , Seroconversión , Pruebas Serológicas/estadística & datos numéricos , Factores de Tiempo , Adulto Joven
17.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 54(6): 368-372, 2019 Jun 09.
Artículo en Zh | MEDLINE | ID: mdl-31177672

RESUMEN

Oral aesthetics is a branch of stomatology. It is based on oral medicine and guided by medical esthetics, and includes maintainance, restoration and construction of the beauty of teeth, oral cavity and maxillofacial region. The development of oral esthetics in China has a long history. The late 1980s and early 1990s are the important historical periods of the development of oral esthetics in China. In recent years, with the development of social economy and culture, China's oral esthetics has developed rapidly. In September 2016, Chinese Society of Esthetic Dentistry, Chinese Stomatological Association was established in Shanghai. With the goal of esthetics, multidisciplinary integration has become the future development trend of oral esthetics.


Asunto(s)
Estética Dental , Medicina Oral , China , Odontología , Predicción
18.
IUCrJ ; 5(Pt 6): 794-800, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30443362

RESUMEN

This study investigated the structural and magnetic properties of Mn3-x Fe x Ga alloys (x = 0, 0.2, 0.4, 0.6, 0.8, 1) under different heat-treatment conditions. A tetragonal structure was observed in samples that were heat treated at 623 K for three days followed by quenching in ice water. These tetragonal alloys present large coercive fields in the range 0.8-5 kOe and low saturation magnetization, and have great potential for application in spin-transfer torque-based devices. A hexagonal structure was observed in samples subjected to heat treatment at 883 K for three days following quenching in ice water. A moderate decrease in the coercive field has been observed for the hexagonal alloys compared with those with a tetragonal structure. However, the Mn3-x Fe x Ga alloys with a hexagonal structure exhibit other attractive magnetic properties, including collinear and non-collinear magnetic properties, holding high promise for technological applications. A face-centred-cubic (f.c.c.) structure was observed when subjected to annealing at 1073 K for three days followed by quenching in ice water. In contrast to the tetragonal and hexagonal structures, all f.c.c. alloys exhibit antiferromagnetic behaviour. This versatile material can display a wide range of multi-functionalities attributed to its tuneable crystal structure. This investigation will guide the design of multiple structures of these materials in order to utilise the wide functionalities for practical applications.

19.
Eur Rev Med Pharmacol Sci ; 21(6): 1290-1295, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28387899

RESUMEN

OBJECTIVE: Chemokine receptor and its ligand participate in viral immunity and HCV infection, which are important inflammatory mediators. The current study showed the different roles of Th cell secreted chemokines CXCR3, CCR5 and CCR6 in chronic liver inflammation after HCV infection. As one important chemokine receptor, the role of polypeptide property and ligand level in HCV prognosis is still unclear. This study aims to investigate gene polymorphism of chemokine genes and ligand level, and their correlation with patient liver function, to provide evidence for HCV prognosis and chronic transition mechanism. PATIENTS AND METHODS: Whole blood samples were collected. Participants were divided into chronic hepatitis, HCV cirrhosis and self-clearance groups. Chemokine level, gene polymorphism of CXCR3 gene at loci rs2280964 and liver index were measured to analyze their correlation with HCV infection or prognosis. RESULTS: Gene polymorphism of CXCR3 at loci rs22809064 is one factor-affecting prognosis of HCV patients. CG genotype at these loci is one independent risk factor affecting chronic HCV infection. IP-10, Mig and I-TAC levels were significantly elevated in chronic hepatitis group or HCV cirrhosis group (p< 0.05 compared to self-clearance group). CONCLUSIONS: Gene polymorphism at rs2280964 locus of chemokine receptor CXCR3 is one possible reason explaining differential processes of chronic transition. CXCR3 ligands IP-10, Mig and I-TAC levels were all significantly elevated in chronic hepatitis and HCV cirrhosis patients, possibly functioning as one clinical index for HCV prognosis.


Asunto(s)
Linfocitos T CD4-Positivos/metabolismo , Hepatitis C Crónica/genética , Receptores CXCR3/genética , Adulto , Quimiocina CXCL10/sangre , Quimiocina CXCL11/sangre , Quimiocina CXCL9/sangre , Femenino , Hepatitis C Crónica/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Polimorfismo Genético
20.
Zhonghua Liu Xing Bing Xue Za Zhi ; 38(2): 147-153, 2017 Feb 10.
Artículo en Zh | MEDLINE | ID: mdl-28231656

RESUMEN

Objective: To study the acute effects of compound ambient air pollution on small airway lung functions among school children in Shanghai. Method: A longitudinal survey on lung functions was conducted among 233 school-children from three schools (A, B and C, located in innerring, mid-ring and outer-ring areas). Lung function test was performed once a week for 3 times respectively, among children in school A and B in Dec. 2013 and in school C in Dec. 2014. The fourth lung function test was tested in Jun. 2014 and May 2015 in the respective schools. Results: from the lung function would include items as: forced mid-expiratory flow at 25% of forced vital capacity (MEF(25%)), mid-expiratory flow at 50% of forced vital capacity (MEF(50%)), mid-expiratory flow at 75% of forced vital capacity (MEF(75%)) and mid-expiratory flow between 25% and 75% of the forced vital capacity (FEF(25%-75%)). Data regarding the daily air quality real-time of PM(2.5), PM(10), SO(2) and NO(2) in Dec. 2013, Dec. 2014, Jun. 2014 and May. 2015 from the three environmental monitoring spots and meteorological data from the Shanghai Meteorological Service system which were physically close to the three schools, were collected simultaneously. Linear mixed effect model was used to examine the levels of correlation between lung function indicators and ambient air pollutants. Results When confounding factors on meteorology and individuals were controlled, the lag effects and accumulated lag effects were found to have existed between the internal quarter rang (IQR) concentration of PM(2.5) and PM(10) in lag2 day and lag02 days, IQR concentration of SO(2) in lag02 day and IQR concentration of NO(2) lag0 day, when small airway lung functions like MEF(25%), MEF(50%), MEF(75%) and FEF(25%-75%)(P<0.05) were inspected. Results from the two air pollutants model analysis showed that SO(2) and NO(2) presenting interactive effects with PM(2.5), PM(10) and lag effects more significant than the individual SO(2) and NO(2), respectively (P<0.05). Conclusion: Contents on the ambient air pollutants as PM(2.5), PM(10), SO(2) and NO(2) were negatively associated with the lung functions in the small airways of children, in Shanghai.


Asunto(s)
Contaminantes Atmosféricos/efectos adversos , Contaminación del Aire/efectos adversos , Pulmón/fisiología , Pruebas de Función Respiratoria , Niño , China , Monitoreo del Ambiente , Femenino , Flujo Espiratorio Forzado , Volumen Espiratorio Forzado , Humanos , Estudios Longitudinales , Pulmón/fisiopatología , Masculino , Enfermedades Respiratorias/etiología , Enfermedades Respiratorias/fisiopatología , Capacidad Vital
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda