Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Crit Care Med ; 38(1): 167-74, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19829103

RESUMEN

OBJECTIVES: To relate early somatosensory evoked potential grades from comatose traumatic brain injury patients to neuropsychological and functional outcome 1 yr later; to determine the day (within the first week after traumatic brain injury) that somatosensory evoked potential grade best correlates with outcome; to determine whether somatosensory evoked potential grade improvement in the first week after traumatic brain injury is associated with improved outcome. DESIGN: Prospective cohort study. SETTING: Critical care unit at a university hospital. PATIENTS: Median nerve somatosensory evoked potentials were obtained from 81 comatose patients with traumatic brain injury. Somatosensory evoked potential grades were calculated from results obtained on days 1, 3, and 7 after traumatic brain injury. Glasgow Outcome Scale, Barthel Index, Rivermead Head Injury Follow-up Questionnaire, General Health Questionnaire, Stroop Color-Word Test, Paced Auditory Serial Addition Task, and Symbol-Digit Modalities Test scores were obtained 1 yr after injury. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Somatosensory evoked potential grade on days 1, 3, and 7 related significantly with Glasgow Outcome Scale and Barthel scores (day 3 better than day 1) but did not relate with Rivermead Head Injury Follow-up Questionnaire or General Health Questionnaire scores. Day 3 and day 7 somatosensory evoked potential grades related significantly with Stroop scores. Day 3 somatosensory evoked potential grades related significantly with Symbol-Digit Modalities Test scores. Patients with bilaterally present but abnormal somatosensory evoked potentials, whose somatosensory evoked potential grade improved between days 1 and 3, had marginally better functional outcome than those without somatosensory evoked potential grade improvement. CONCLUSIONS: Day 3 somatosensory evoked potential grade related to information-processing speed, working memory, and the ability to attend to tasks 1 yr after traumatic brain injury. Day 3 somatosensory evoked potential grade had the strongest relationship with functional outcome. Somatosensory evoked potential grades were not related to emotional well-being.


Asunto(s)
Lesiones Encefálicas/complicaciones , Lesiones Encefálicas/diagnóstico , Trastornos del Conocimiento/etiología , Potenciales Evocados Somatosensoriales , Recuperación de la Función , Actividades Cotidianas , Adulto , Anciano , Lesiones Encefálicas/terapia , Trastornos del Conocimiento/epidemiología , Trastornos del Conocimiento/fisiopatología , Estudios de Cohortes , Coma/complicaciones , Coma/diagnóstico , Coma/terapia , Cuidados Críticos/métodos , Diagnóstico Precoz , Femenino , Estudios de Seguimiento , Escala de Coma de Glasgow , Escala de Consecuencias de Glasgow , Hospitales Universitarios , Humanos , Puntaje de Gravedad del Traumatismo , Unidades de Cuidados Intensivos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Valor Predictivo de las Pruebas , Probabilidad , Estudios Prospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Adulto Joven
2.
Can J Neurol Sci ; 31(3): 347-56, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15376479

RESUMEN

OBJECTIVE: To prospectively compare somatosensory evoked potentials, electroencephalography (EEG) and transcranial Doppler ultrasound (TCD) for detection of cerebral ischemia during carotid endarterectomy (CEA). METHODS: Somatosensory evoked potentials and EEG recordings were attempted in 156 consecutive CEAs and TCD was also attempted in 91 of them. Recordings from all three modalities were obtained for at least 10 minutes before CEA, during CEA and for at least 15 minutes after CEA. Somatosensory evoked potentials peak-to-peak amplitude decrease of >50%, EEG amplitude decrease of >75%, and ipsilateral middle cerebral artery mean blood flow velocity (mean VMCAi) decrease >75% persisting for the entire period of internal carotid artery occlusion were individually considered to be diagnostic of cerebral ischemia. Clinical neurological examination was performed immediately prior to surgery and following recovery from general anaesthesia. RESULTS: Somatosensory evoked potentials, EEG, and TCD were successfully obtained throughout the entire period of internal carotid artery occlusion in 99%, 95%, and 63% of patients respectively. Two patients (1.3%) suffered intraoperative cerebral infarction detected by clinical neurological examination and subsequent magnetic resonance imaging. Somatosensory evoked potentials accurately predicted intraoperative cerebral infarction in both instances without false negatives or false positives, EEG yielded one false negative result and no false positive results and VMCAi one true positive, four false positive and no false negative results. Transcranial Doppler ultrasound detection of emboli did not correlate with postoperative neurological deficits. Nevertheless the sensitivity and specificity of each test was not significantly different than the others because of the small number of disagreements between tests. CONCLUSION: A >50% decrease in the cortically generated P25 amplitude of the median somatosensory evoked potentials, which persisted during the entire period of internal carotid artery occlusion, appears to be the most reliable method of monitoring for intraoperative ischemia in our hands because it accurately detected both intraoperative strokes with no false positive or false negative results.


Asunto(s)
Isquemia Encefálica/diagnóstico , Isquemia Encefálica/cirugía , Endarterectomía Carotidea , Monitoreo Intraoperatorio/métodos , Anciano , Infarto Cerebral/prevención & control , Electroencefalografía , Potenciales Evocados Somatosensoriales , Humanos , Embolia Intracraneal/diagnóstico , Monitoreo Intraoperatorio/normas , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía Doppler Transcraneal
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda