1.
J Cardiovasc Magn Reson ; 15: 23, 2013 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-23497030

RESUMEN

BACKGROUND: Functional and morphologic assessment of the right ventricle (RV) is of clinical importance. Cardiovascular magnetic resonance (CMR) at 1.5T has become gold standard for RV chamber quantification and assessment of even small wall motion abnormalities, but tissue analysis is still hampered by limited spatial resolution. CMR at 7T promises increased resolution, but is technically challenging. We examined the feasibility of cine imaging at 7T to assess the RV. METHODS: Nine healthy volunteers underwent CMR at 7T using a 16-element TX/RX coil and acoustic cardiac gating. 1.5T served as gold standard. At 1.5T, steady-state free-precession (SSFP) cine imaging with voxel size (1.2 x 1.2 x 6) mm3 was used; at 7T, fast gradient echo (FGRE) with voxel size (1.2 x 1.2 x 6) mm3 and (1.3 x 1.3 x 4) mm3 were applied. RV dimensions (RVEDV, RVESV), RV mass (RVM) and RV function (RVEF) were quantified in transverse slices. Overall image quality, image contrast and image homogeneity were assessed in transverse and sagittal views. RESULTS: All scans provided diagnostic image quality. Overall image quality and image contrast of transverse RV views were rated equally for SSFP at 1.5T and FGRE at 7T with voxel size (1.3 x 1.3 x 4)mm3. FGRE at 7T provided significantly lower image homogeneity compared to SSFP at 1.5T. RVEDV, RVESV, RVEF and RVM did not differ significantly and agreed close between SSFP at 1.5T and FGRE at 7T (p=0.5850; p=0.5462; p=0.2789; p=0.0743). FGRE at 7T with voxel size (1.3 x 1.3 x 4) mm3 tended to overestimate RV volumes compared to SSFP at 1.5T (mean difference of RVEDV 8.2 ± 9.3 ml) and to FGRE at 7T with voxel size (1.2 x 1.2 x 6) mm3 (mean difference of RVEDV 9.3 ± 8.6 ml). CONCLUSIONS: FGRE cine imaging of the RV at 7T was feasible and provided good image quality. RV dimensions and function were comparable to SSFP at 1.5T as gold standard.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Imagen por Resonancia Cinemagnética , Volumen Sistólico , Función Ventricular Derecha , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Fonocardiografía , Valor Predictivo de las Pruebas , Valores de Referencia , Adulto Joven
2.
J Magn Reson Imaging ; 36(4): 847-57, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22706727

RESUMEN

PURPOSE: To design, evaluate, and apply a 2D 16-channel transmit/receive (TX/RX) coil array tailored for cardiac magnetic resonance imaging (MRI) at 7.0 T. MATERIALS AND METHODS: The cardiac coil array consists of two sections each using eight elements arranged in a 2 × 4 array. Radiofrequency (RF) safety was validated by specific absorption rate (SAR) simulations. Cardiac imaging was performed using 2D CINE FLASH imaging, T 2 mapping, and fat-water separation imaging. The characteristics of the coil array were analyzed including parallel imaging performance, left ventricular chamber quantification, and overall image quality. RESULTS: RF characteristics were found to be appropriate for all subjects included in the study. The SAR values derived from the simulations fall well within the limits of legal guidelines. The baseline signal-to-noise ratio (SNR) advantage at 7.0 T was put to use to acquire 2D CINE images of the heart with a very high spatial resolution of (1 × 1 × 4) mm(3) . The proposed coil array supports 1D acceleration factors of up to R = 4 without significantly impairing image quality. CONCLUSION: The 16-channel TX/RX coil has the capability to acquire high contrast and high spatial resolution images of the heart at 7.0 T.


Asunto(s)
Corazón/anatomía & histología , Aumento de la Imagen/instrumentación , Imagen por Resonancia Cinemagnética/métodos , Magnetismo/instrumentación , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Eur Radiol ; 22(10): 2211-20, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22653280

RESUMEN

OBJECTIVES: To implement, examine, and compare three multichannel transmit/receive coil configurations for cardiovascular MR (CMR) at 7T. METHODS: Three radiofrequency transmit-receive (TX/RX) coils with 4-, 8-, and 16-coil elements were used. Ten healthy volunteers (seven males, age 28 ± 4 years) underwent CMR at 7T. For all three RX/TX coils, 2D CINE FLASH images of the heart were acquired. Cardiac chamber quantification, signal-to-noise ratio (SNR) analysis, parallel imaging performance assessment, and image quality scoring were performed. RESULTS: Mean total examination time was 29 ± 5 min. All images obtained with the 8- and 16-channel coils were diagnostic. No significant difference in ejection fraction (EF) (P > 0.09) or left ventricular mass (LVM) (P > 0.31) was observed between the coils. The 8- and 16-channel arrays yielded a higher mean SNR in the septum versus the 4-channel coil. The lowest geometry factors were found for the 16-channel coil (mean ± SD 2.3 ± 0.5 for R = 4). Image quality was rated significantly higher (P < 0.04) for the 16-channel coil versus the 8- and 4-channel coils. CONCLUSIONS: All three coil configurations are suitable for CMR at 7.0T under routine circumstances. A larger number of coil elements enhances image quality and parallel imaging performance but does not impact the accuracy of cardiac chamber quantification. KEY POINTS : • Cardiac chamber quantification using 7.0T magnetic resonance imaging is feasible. • Examination times for cardiac chamber quantification at 7.0T match current clinical practice. • Multichannel transceiver RF technology facilitates improved image quality and parallel imaging performance. • Increasing the number of RF channels does not influence cardiac chamber quantification.


Asunto(s)
Técnicas de Imagen Cardíaca , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Masculino , Adulto Joven
4.
PLoS One ; 10(1): e0117095, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25621491

RESUMEN

PURPOSE: This study examines the subjective acceptance during UHF-CMR in a cohort of healthy volunteers who underwent a cardiac MR examination at 7.0T. METHODS: Within a period of two-and-a-half years (January 2012 to June 2014) a total of 165 healthy volunteers (41 female, 124 male) without any known history of cardiac disease underwent UHF-CMR. For the assessment of the subjective acceptance a questionnaire was used to examine the participants experience prior, during and after the UHF-CMR examination. For this purpose, subjects were asked to respond to the questionnaire in an exit interview held immediately after the completion of the UHF-CMR examination under supervision of a study nurse to ensure accurate understanding of the questions. All questions were answered with "yes" or "no" including space for additional comments. RESULTS: Transient muscular contraction was documented in 12.7% of the questionnaires. Muscular contraction was reported to occur only during periods of scanning with the magnetic field gradients being rapidly switched. Dizziness during the study was reported by 12.7% of the subjects. Taste of metal was reported by 10.1% of the study population. Light flashes were reported by 3.6% of the entire cohort. 13% of the subjects reported side effects/observations which were not explicitly listed in the questionnaire but covered by the question about other side effects. No severe side effects as vomiting or syncope after scanning occurred. No increase in heart rate was observed during the UHF-CMR exam versus the baseline clinical examination. CONCLUSIONS: This study adds to the literature by detailing the subjective acceptance of cardiovascular magnetic resonance imaging examinations at a magnetic field strength of 7.0T. Cardiac MR examinations at 7.0T are well tolerated by healthy subjects. Broader observational and multi-center studies including patient cohorts with cardiac diseases are required to gain further insights into the subjective acceptance of UHF-CMR examinations.


Asunto(s)
Corazón/anatomía & histología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Encuestas y Cuestionarios , Adulto Joven
5.
Eur J Radiol ; 82(5): 752-9, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-21920683

RESUMEN

The objective of this work is to design, examine and apply an eight channel transmit/receive coil array tailored for cardiac magnetic resonance imaging at 7.0 T that provides image quality suitable for clinical use, patient comfort, and ease of use. The cardiac coil array was designed to consist of a planar posterior section and a modestly curved anterior section. For radio frequency (RF) safety validation, numerical computations of the electromagnetic field (EMF) and the specific absorption rate (SAR) distribution were conducted. In vivo cardiac imaging was performed using a 2D CINE FLASH technique. For signal-to-noise ratio (SNR) assessment reconstructed images were scaled in SNR units. The parallel imaging capabilities of the coil were examined using GRAPPA and SENSE reconstruction with reduction factors of up to R=4. The assessment of the RF characteristics yielded a maximum noise correlation of 0.33. The baseline SNR advantage at 7.0 T was put to use to acquire 2D CINE images of the heart with a spatial resolution of 1 mm × 1 mm × 4 mm. The coil array supports 1D acceleration factors of up to R=3 without impairing image quality significantly. For un-accelerated 2D CINE FLASH acquisitions the results revealed an SNR of approximately 140 for the left ventricular blood pool. Blood/myocardium contrast was found to be approximately 90 for un-accelerated 2D CINE FLASH acquisitions. The proposed 8 channel cardiac transceiver surface coil has the capability to acquire high contrast, high spatial and temporal resolution in vivo images of the heart at 7.0 T.


Asunto(s)
Ventrículos Cardíacos/anatomía & histología , Aumento de la Imagen/instrumentación , Imagen por Resonancia Cinemagnética/instrumentación , Magnetismo/instrumentación , Volumen Sistólico/fisiología , Transductores , Función Ventricular Izquierda/fisiología , Adulto , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Magn Reson ; 229: 208-22, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23290625

RESUMEN

A growing number of reports eloquently speak about explorations into cardiac magnetic resonance (CMR) at ultrahigh magnetic fields (B0≥7.0 T). Realizing the progress, promises and challenges of ultrahigh field (UHF) CMR this perspective outlines current trends in enabling MR technology tailored for cardiac MR in the short wavelength regime. For this purpose many channel radiofrequency (RF) technology concepts are outlined. Basic principles of mapping and shimming of transmission fields including RF power deposition considerations are presented. Explorations motivated by the safe operation of UHF-CMR even in the presence of conductive implants are described together with the physics, numerical simulations and experiments, all of which detailing antenna effects and RF heating induced by intracoronary stents at 7.0 T. Early applications of CMR at 7.0 T and their clinical implications for explorations into cardiovascular diseases are explored including assessment of cardiac function, myocardial tissue characterization, MR angiography of large and small vessels as well as heteronuclear MR of the heart and the skin. A concluding section ventures a glance beyond the horizon and explores future directions. The goal here is not to be comprehensive but to inspire the biomedical and diagnostic imaging communities to throw further weight behind the solution of the many remaining unsolved problems and technical obstacles of UHF-CMR with the goal to transfer MR physics driven methodological advancements into extra clinical value.


Asunto(s)
Campos Electromagnéticos , Corazón/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Algoritmos , Animales , Vasos Coronarios/patología , Corazón/fisiología , Humanos , Imagen por Resonancia Magnética/tendencias , Física , Ondas de Radio , Stents
7.
PLoS One ; 7(12): e52324, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23251708

RESUMEN

Myocardial tissue characterization using T(2)(*) relaxation mapping techniques is an emerging application of (pre)clinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T(2)(*) mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T(2)(*) imaging at 7.0 T and examines the applicability of temporally-resolved and high spatial resolution myocardial T(2)(*) mapping. In phantom experiments single cardiac phase and dynamic (CINE) gradient echo imaging techniques provided similar T(2)(*) maps. In vivo studies showed that the peak-to-peak B(0) difference following volume selective shimming was reduced to approximately 80 Hz for the four chamber view and mid-ventricular short axis view of the heart and to 65 Hz for the left ventricle. No severe susceptibility artifacts were detected in the septum and in the lateral wall for T(2)(*) weighting ranging from TE = 2.04 ms to TE = 10.2 ms. For TE >7 ms, a susceptibility weighting induced signal void was observed within the anterior and inferior myocardial segments. The longest T(2)(*) values were found for anterior (T(2)(*) = 14.0 ms), anteroseptal (T(2)(*) = 17.2 ms) and inferoseptal (T(2)(*) = 16.5 ms) myocardial segments. Shorter T(2)(*) values were observed for inferior (T(2)(*) = 10.6 ms) and inferolateral (T(2)(*) = 11.4 ms) segments. A significant difference (p = 0.002) in T(2)(*) values was observed between end-diastole and end-systole with T(2)(*) changes of up to approximately 27% over the cardiac cycle which were pronounced in the septum. To conclude, these results underscore the challenges of myocardial T(2)(*) mapping at 7.0 T but demonstrate that these issues can be offset by using tailored shimming techniques and dedicated acquisition schemes.


Asunto(s)
Corazón/anatomía & histología , Imagen por Resonancia Magnética/métodos , Estudios de Factibilidad , Corazón/fisiología , Humanos , Campos Magnéticos , Fantasmas de Imagen