Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Phys Med ; 24(2): 117-21, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18291697

RESUMEN

I-ImaS (Intelligent Imaging Sensors) is a European project aiming to produce real-time adaptive X-ray imaging systems using Monolithic Active Pixel Sensors (MAPS) to create images with maximum diagnostic information within given dose constraints. Initial systems concentrate on mammography and cephalography. In our system, the exposure in each image region is optimised and the beam intensity is a function of tissue thickness and attenuation, and also of local physical and statistical parameters in the image. Using a linear array of detectors, the system will perform on-line analysis of the image during the scan, followed by optimisation of the X-ray intensity to obtain the maximum diagnostic information from the region of interest while minimising exposure of diagnostically less important regions. This paper presents preliminary images obtained with a small area CMOS detector developed for this application. Wedge systems were used to modulate the beam intensity during breast and dental imaging using suitable X-ray spectra. The sensitive imaging area of the sensor is 512 x 32 pixels 32 x 32 microm(2) in size. The sensors' X-ray sensitivity was increased by coupling to a structured CsI(Tl) scintillator. In order to develop the I-ImaS prototype, the on-line data analysis and data acquisition control are based on custom-developed electronics using multiple FPGAs. Images of both breast tissues and jaw samples were acquired and different exposure optimisation algorithms applied. Results are very promising since the average dose has been reduced to around 60% of the dose delivered by conventional imaging systems without decrease in the visibility of details.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Algoritmos , Fenómenos Biofísicos , Biofisica , Femenino , Humanos , Maxilares/diagnóstico por imagen , Mamografía/instrumentación , Mamografía/estadística & datos numéricos , Radiografía Dental/instrumentación , Radiografía Dental/estadística & datos numéricos
3.
Dentomaxillofac Radiol ; 35(3): 147-51, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16618846

RESUMEN

OBJECTIVE: To survey end-user opinions on dental digital sensor characteristics for the design of a new X-ray imaging sensor. MATERIALS AND METHODS: 100 questionnaires were sent out to dentists and dental radiologists. The questionnaire consisted of six parts related to dental sensors. A: Details about the respondent; B: Prioritization of most important aspects of digital sensors; C: Rating advantages and D: disadvantages of digital sensors; F: Dental features that need to be enhanced by digital sensors; G: End-user comments. RESULTS: Fifty-six questionnaires were returned. Contrast resolution and imaging time were assessed as the most and the least important aspects, respectively. Aspects considered as advantages by approximately 80% of respondents were: optimal contrast resolution, increased specificity, increased discrimination between diseased and healthy tissue, increased sensitivity, lower dose to the patient by more than 20%; as a disadvantage, increased patient dose was given. Dental features considered important by over 80% of the respondents were for intraoral radiographs: the visibility of caries, periapical, periodontal, and bone lesions; for panoramic radiographs: reduction of ghost images, image sharpness and bone. Bone and soft tissues on cephalograms and bone on temporomandibular joint (TMJ) tomograms were mentioned by over 70%. CONCLUSION: The most desired characteristic for a new sensor is contrast resolution. Dose saving is not considered as important unless it is more than 20%. Examination time is not a major issue. Caries, periapical and periodontal, and bone lesions for intraoral radiographs, reduction of ghost images, image sharpness and bone for panoramic radiographs were the most frequently mentioned dental features that should be enhanced by digital sensors.


Asunto(s)
Radiografía Dental Digital , Pantallas Intensificadoras de Rayos X , Artefactos , Medios de Contraste , Odontólogos , Humanos , Proyectos Piloto , Dosis de Radiación , Radiología , Encuestas y Cuestionarios
4.
Nephron ; 84(4): 320-5, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10754408

RESUMEN

BACKGROUND/AIM: Decreased sensitivity to the hypoglycaemic action of insulin is an almost universal phenomenon in uraemic patients, and it is attributed either to uraemic toxins or to anaemia or even to secondary hyperparathyroidism. Considering the conflicting data of few existing studies, we examined the influence of erythropoietin (EPO) treatment on insulin resistance and tested the probable correlation of this influence with sympathetic nervous system (SNS) activity. METHODS: We studied 8 non-obese, non-diabetic, stable dialysis patients using the euglycaemic insulin clamp technique before administration of EPO (phase A), 10 days after (phase B), and after the correction of the haematocrit level, at least 8 weeks later (phase C). We estimated the indices (glucose infusion rate, mg/kg/min), M/G (glucose clearance), and M/I (tissue sensitivity to insulin), and we measured haematocrit, haemoglobin, triglyceride, ferritin, EPO, and fasting insulin levels in each phase. During each phase, we tested the SNS activity using the response of blood pressure to persistent handgrip and the response of blood pressure to the standing position. RESULTS: Our patients appeared to have an increased insulin resistance in phase A (M(A) = 6.24 +/- 1.01) which was significantly improved 10 days after the beginning of EPO treatment and before the rise of haematocrit (M(B) = 7.71 +/- 1.54, p < 0.05). There was no further improvement in phase C. Indices M/G and M/I behaved similarly. The serum triglyceride levels decreased in response to the increased insulin sensitivity. The patients studied did not demonstrate fasting hyperinsulinaemia, while the SNS activity was abnormal and remained unchanged throughout the study period in spite of some individual improvement. CONCLUSIONS: Our study proves the beneficial effect of EPO treatment on insulin resistance in dialysis patients which could be attributed to the EPO itself and not to the correction of anaemia and is accompanied by improvement in triglyceride levels. Amelioration of insulin resistance did not influence the SNS activity, making the association between EPO treatment and SNS-derived changes in blood pressure quite improbable.


Asunto(s)
Eritropoyetina/farmacología , Resistencia a la Insulina , Diálisis Renal , Anciano , Anciano de 80 o más Años , Eritropoyetina/administración & dosificación , Eritropoyetina/efectos adversos , Femenino , Técnica de Clampeo de la Glucosa , Humanos , Hipertensión/etiología , Hipertensión/fisiopatología , Fallo Renal Crónico/tratamiento farmacológico , Fallo Renal Crónico/fisiopatología , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Proteínas Recombinantes , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda