RESUMEN
PURPOSE: The recent development and approval of new diagnostic imaging and therapy approaches in the field of theranostics have revolutionised nuclear medicine practice. To ensure the provision of these new imaging and therapy approaches in a safe and high-quality manner, training of nuclear medicine physicians and qualified specialists is paramount. This is required for trainees who are learning theranostics practice, and for ensuring minimum standards for knowledge and competency in existing practising specialists. METHODS: To address the need for a training curriculum in theranostics that would be utilised at a global level, a Consultancy Meeting was held at the IAEA in May 2023, with participation by experts in radiopharmaceutical therapy and theranostics including representatives of major international organisations relevant to theranostics practice. RESULTS: Through extensive discussions and review of existing curriculum and guidelines, a harmonised training program for theranostics was developed, which aims to ensure safe and high quality theranostics practice in all countries. CONCLUSION: The guiding principles for theranostics training outlined in this paper have immediate relevance for the safe and effective practice of theranostics.
Asunto(s)
Medicina Nuclear , Humanos , Medicina Nuclear/educación , Nanomedicina Teranóstica , CurriculumRESUMEN
AIM: The aim of this study was to assess the recovery rates of diagnostic cardiac procedure volumes in the Oceania Region, midway through the coronavirus disease 2019 (COVID-19) pandemic. METHODS: A survey was performed comparing procedure volumes between March 2019 (pre-pandemic), April 2020 (during first wave of COVID-19 pandemic), and April 2021 (1 year into the COVID-19 pandemic). A total of 31 health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, as well as teaching and non-teaching hospitals. A comparison was made with 549 centres in 96 countries in the rest of the world (RoW) outside of Oceania. The total number and median percentage change in procedure volume were measured between the three timepoints, compared by test type and by facility. RESULTS: A total of 11,902 cardiac diagnostic procedures were performed in Oceania in April 2021 as compared with 11,835 pre-pandemic in March 2019 and 5,986 in April 2020; whereas, in the RoW, 499,079 procedures were performed in April 2021 compared with 497,615 pre-pandemic in March 2019 and 179,014 in April 2020. There was no significant difference in the median recovery rates for total procedure volumes between Oceania (-6%) and the RoW (-3%) (p=0.81). While there was no statistically significant difference in percentage recovery been functional ischaemia testing and anatomical coronary testing in Oceania as compared with the RoW, there was, however, a suggestion of poorer recovery in anatomical coronary testing in Oceania as compared with the RoW (CT coronary angiography -16% in Oceania vs -1% in RoW, and invasive coronary angiography -20% in Oceania vs -9% in RoW). There was no statistically significant difference in recovery rates in procedure volume between metropolitan vs regional (p=0.44), public vs private (p=0.92), hospital vs outpatient (p=0.79), or teaching vs non-teaching centres (p=0.73). CONCLUSIONS: Total cardiology procedure volumes in Oceania normalised 1 year post-pandemic compared to pre-pandemic levels, with no significant difference compared with the RoW and between the different types of health care facilities.
Asunto(s)
COVID-19 , Cardiología , Humanos , COVID-19/epidemiología , Pandemias , Encuestas y Cuestionarios , Angiografía Coronaria , Prueba de COVID-19RESUMEN
OBJECTIVES: The INCAPS COVID Oceania study aimed to assess the impact caused by the COVID-19 pandemic on cardiac procedure volume provided in the Oceania region. METHODS: A retrospective survey was performed comparing procedure volumes within March 2019 (pre-COVID-19) with April 2020 (during first wave of COVID-19 pandemic). Sixty-three (63) health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, and 846 facilities outside of Oceania. The percentage change in procedure volume was measured between March 2019 and April 2020, compared by test type and by facility. RESULTS: In Oceania, the total cardiac diagnostic procedure volume was reduced by 52.2% from March 2019 to April 2020, compared to a reduction of 75.9% seen in the rest of the world (p<0.001). Within Oceania sites, this reduction varied significantly between procedure types, but not between types of health care facility. All procedure types (other than stress cardiac magnetic resonance [CMR] and positron emission tomography [PET]) saw significant reductions in volume over this time period (p<0.001). In Oceania, transthoracic echocardiography (TTE) decreased by 51.6%, transoesophageal echocardiography (TOE) by 74.0%, and stress tests by 65% overall, which was more pronounced for stress electrocardiograph (ECG) (81.8%) and stress echocardiography (76.7%) compared to stress single-photon emission computerised tomography (SPECT) (44.3%). Invasive coronary angiography decreased by 36.7% in Oceania. CONCLUSION: A significant reduction in cardiac diagnostic procedure volume was seen across all facility types in Oceania and was likely a function of recommendations from cardiac societies and directives from government to minimise spread of COVID-19 amongst patients and staff. Longer term evaluation is important to assess for negative patient outcomes which may relate to deferral of usual models of care within cardiology.
Asunto(s)
COVID-19 , Cardiología , Humanos , Pandemias , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND: A large proportion of the huge global burden of extrapulmonary tuberculosis (EPTB) cases are treated empirically without accurate definition of disease sites and extent of multi-organ disease involvement. Positron emission tomography (PET) imaging using 2-deoxy-2-(fluorine-18) fluoro-d-glucose (18F-FDG) in tuberculosis could be a useful imaging technique for localising disease sites and extent of disease. METHODS: We conducted a study of HIV-negative adult patients with a new clinical diagnosis of EPTB across eight centres located in six countries: India, Pakistan, Thailand, South Africa, Serbia and Bangladesh, to assess the extent of disease and common sites involved at first presentation. 18F-FDG PET/computed tomography (CT) scans were performed within 2â weeks of presentation. FINDINGS: 358 patients with EPTB (189 females; 169 males) were recruited over 45â months, with an age range of 18-83â years (females median 30â years; males median 38â years). 350 (98%) out of 358 patients (183 female, 167 male) had positive scans. 118 (33.7%) out of 350 had a single extrapulmonary site and 232 (66.3%) out of 350 had more than one site (organ) affected. Lymph nodes, skeleton, pleura and brain were common sites. 100 (28%) out of 358 EPTB patients had 18F-FDG PET/CT-positive sites in the lung. 110 patients were 18F-FDG PET/CT-positive in more body sites than were noted clinically at first presentation and 160 patients had the same number of positive body sites. INTERPRETATION: 18F-FDG PET/CT scan has potential for further elucidating the spectrum of disease, pathogenesis of EPTB and monitoring the effects of treatment on active lesions over time, and requires longitudinal cohort studies, twinned with biopsy and molecular studies.
Asunto(s)
Fluorodesoxiglucosa F18 , Tuberculosis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Bangladesh , Estudios Transversales , Femenino , Humanos , India , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pakistán , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Radiofármacos , Sudáfrica , Tuberculosis/diagnóstico por imagen , Adulto JovenRESUMEN
BACKGROUND: Initial studies of tuberculosis (TB) in macaques and humans using 18F-FDG positron emission tomography (PET) imaging as a research tool suggest its usefulness in localising disease sites and as a clinical biomarker. Sequential serial scans in patients with extrapulmonary TB (EPTB) could inform on the value of PET-CT for monitoring response to treatment and defining cure. PATIENTS AND METHODS: HIV-negative adults with EPTB from eight sites across six countries had three 18F-FDG PET/CT scans: (i) within 2 weeks of enrolment, (ii) at 2 months into TB treatment and (iii) at end of ATT treatment. Scanning was performed according to the EANM guidelines. 18F-FDG PET/CT scans were performed 60 ± 10 min after intravenous injection of 2.5-5.0 MBq/kg of 18F-FDG. FINDINGS: One hundred and forty-seven patients with EPTB underwent 3 sequential scans. A progressive reduction over time of both the number of active sites and the uptake level (SUVmax) at these sites was seen. At the end of WHO recommended treatment, 53/147 (36.0%) patients had negative PET/CT scans, and 94/147 (63.9%) patients remained PET/CT positive, of which 12 patients had developed MDR TB. One died of brain tuberculoma. INTERPRETATION: Current 18F-FDG PET/CT imaging technology cannot be used clinically as a biomarker of treatment response, cure or for decision-making on when to stop EPTB treatment. PET/CT remains a research tool for TB and further development of PET/CT is required using new Mycobacterium tuberculosis-specific radiopharmaceuticals targeting high-density surface epitopes, gene targets or metabolic pathways.
Asunto(s)
Fluorodesoxiglucosa F18 , Tuberculosis , Adulto , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Radiofármacos , Tuberculosis/diagnóstico por imagenRESUMEN
BACKGROUND: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. METHODS AND RESULTS: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight "best practices" were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus. CONCLUSIONS: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the "as low as reasonably achievable" (ALARA) principle.
Asunto(s)
Cardiología/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Exposición a la Radiación/prevención & control , Protección Radiológica/estadística & datos numéricos , Tomografía Computarizada de Emisión/estadística & datos numéricos , Cardiología/estadística & datos numéricos , Adhesión a Directriz/normas , Adhesión a Directriz/estadística & datos numéricos , Encuestas de Atención de la Salud , Humanos , Internacionalidad , América Latina/epidemiología , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Pautas de la Práctica en Medicina/normas , Mejoramiento de la Calidad , Protección Radiológica/normas , Tomografía Computarizada de Emisión/normas , Revisión de Utilización de RecursosRESUMEN
BACKGROUND: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia.MethodsâandâResults:Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. CONCLUSIONS: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.
Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Pautas de la Práctica en Medicina/normas , Exposición a la Radiación/estadística & datos numéricos , Anciano , Asia , Cardiología/métodos , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medicina Nuclear/métodos , Calidad de la Atención de Salud , Dosis de Radiación , Tecnecio/administración & dosificación , Talio/administración & dosificaciónRESUMEN
BACKGROUND: There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. METHODS: Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. RESULTS: In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). CONCLUSION: Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world.
Asunto(s)
Imagen de Perfusión Miocárdica/efectos adversos , Dosis de Radiación , Exposición a la Radiación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , OceaníaRESUMEN
PURPOSE: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. METHODS: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). RESULTS: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. CONCLUSION: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.
Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Tomografía de Emisión de Positrones/métodos , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Técnicas de Imagen Cardíaca/efectos adversos , Técnicas de Imagen Cardíaca/instrumentación , Técnicas de Imagen Cardíaca/normas , Cardiología/organización & administración , Unión Europea , Medicina Nuclear/organización & administración , Tomografía de Emisión de Positrones/efectos adversos , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/normas , Sociedades CientíficasRESUMEN
AIMS: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. METHODS AND RESULTS: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. CONCLUSION: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.
Asunto(s)
Adhesión a Directriz/normas , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Guías de Práctica Clínica como Asunto/normas , Dosis de Radiación , Exposición a la Radiación/análisis , Anciano , Cardiología/normas , Protocolos Clínicos/normas , Estudios Transversales , Femenino , Salud Global , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Tomografía de Emisión de Positrones/normas , Tomografía de Emisión de Positrones/estadística & datos numéricos , Práctica Profesional/normas , Práctica Profesional/estadística & datos numéricos , Calidad de la Atención de Salud/normas , Calidad de la Atención de Salud/estadística & datos numéricos , Análisis de Regresión , Tomografía Computarizada de Emisión de Fotón Único/normas , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricosRESUMEN
The number of lung transplantations is limited due to the shortage of donor lungs fulfilling the standard criteria. The ex vivo lung perfusion (EVLP) technique provides the ability of re-evaluating and potentially improving and treating marginal donor lungs. Accordingly, the technique has emerged as an essential tool to increase the much-needed donor lung pool. One of the major EVLP protocols, the Lund protocol, characterized by high pulmonary artery flow (100% of cardiac output [CO]), an open atrium, and a cellular perfusate, has demonstrated encouraging short-EVLP duration results. However, the potential of the longer EVLP duration of the protocol is yet to be investigated, a duration which is considered necessary to rescue more marginal donor lungs in future. This study aimed to achieve stable 8-h EVLP using an open-atrium cellular model with three different pulmonary artery flows in addition to determining the most optimal flow in terms of best lung performance, including lung electrolytes and least lung edema formation, perfusate and tissue inflammation, and histopathological changes, using the porcine model. EVLP was performed using a flow of either 40% (n = 6), 80% (n = 6), or 100% (n = 6) of CO. No flow rate demonstrated stable 8-h EVLP. Stable 2-h EVLP was observed in all three groups. Insignificant deterioration was observed in dynamic compliance, peak airway pressure, and oxygenation between the groups. Pulmonary vascular resistance increased significantly in the 40% group (p < .05). Electrolytes demonstrated an insignificant worsening trend with longer EVLP. Interleukin-8 (IL-8) in perfusate and tissue, wet-to-dry weight ratio, and histopathological changes after EVLP were insignificantly time dependent between the groups. This study demonstrated that stable 8-h EVLP was not feasible in an open-atrium cellular model regardless of the flow of 40%, 80%, or 100% of CO. No flow was superior in terms of lung performance, lung electrolytes changes, least lung edema formation, minimal IL-8 expression in perfusate and tissue, and histopathological changes.
RESUMEN
The COVID-19 pandemic disrupted the delivery of cardiovascular care, including noninvasive testing protocols and test selection for the evaluation of coronary artery disease (CAD). Trends in test selection in traditional versus advanced noninvasive tests for CAD during the pandemic and in countries of varying income status have not been well studied. The International Atomic Energy Agency conducted a global survey to assess the pandemic-related changes in the practice of cardiovascular diagnostic testing. Site procedural volumes for noninvasive tests to evaluate CAD from March 2019 (prepandemic), April 2020 (onset), and April 2021 (initial recovery) were collected. We considered traditional testing modalities, such as exercise electrocardiography, stress echocardiography, and stress single-photon emission computed tomography, and advanced testing modalities, such as stress cardiac magnetic resonance, coronary computed tomography angiography, and stress positron emission tomography. Survey data were obtained from 669 centers in 107 countries, reporting the performance of 367,933 studies for CAD during the study period. Compared with 2019, traditional tests were performed 14% less frequently (recovery rate 82%) in 2021 versus advanced tests, which were performed 15% more frequently (128% recovery rate). Coronary computed tomography angiography, stress cardiac magnetic resonance, and stress positron emission tomography showed 14%, 25%, and 25% increases in volumes from 2019 to 2021, respectively. The increase in advanced testing was isolated to high- and upper middle-income countries, with 132% recovery in advanced tests by 2021 compared with 55% in lower income nations. The COVID-19 pandemic exacerbated economic disparities in CAD testing practice between wealthy and poorer countries. Greater recovery rates and even new growth were observed for advanced imaging modalities; however, this growth was restricted to wealthy countries. Efforts to reduce practice variations in CAD testing because of economic status are warranted.
Asunto(s)
COVID-19 , Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Angiografía Coronaria/métodos , Pandemias , COVID-19/epidemiología , Tomografía Computarizada de Emisión de Fotón Único/métodos , Prueba de EsfuerzoRESUMEN
Background: The COVID-19 pandemic disproportionately impacted Latin America (LATAM), significantly disrupting cardiovascular testing. This study evaluated cardiac procedure recovery in LATAM one year after the outbreak. Methods: The International Atomic Energy Agency (IAEA) surveyed 669 centers in 107 countries worldwide, including 135 facilities in 19 LATAM countries, to assess cardiovascular procedure volumes in March 2019, April 2020, and April 2021, and changes in center practices and staffing conditions one year into the COVID-19 pandemic. Findings: LATAM centers reported a 21 % decrease in procedure volumes in April 2021 from pre-pandemic-baseline, vs. a 0 % change in the rest of the world (RoW), and greater volume reductions for almost all procedure types. Centers in Central America and Mexico reported the largest procedure reductions (47 % reduction) compared to the Caribbean (15 %), and South America (14 %, p = 0.01), and this LATAM region was a significant predictor of lower procedure recovery in multivariable regression. More LATAM centers reported reduced salaries and increased layoffs of clinical staff compared to RoW, and LATAM respondents estimated that half of physician and non-physician staff experienced excess psychological stress related to the pandemic, compared to 25 % and 30 % in RoW (p < 0.001). Conclusions: Cardiovascular testing recovery in LATAM trailed behind RoW for most procedure types, with centers in Central America and Mexico reporting the greatest volume reductions. This study found lasting impacts of COVID-19 on cardiovascular care in LATAM and the need for mental health support for LATAM healthcare workers in current and future pandemics.
RESUMEN
Aims: Recovery of cardiovascular diagnostic testing in Italy after the coronavirus disease-2019 (COVID-19) pandemic has not been quantified. The study aims to describe cardiac diagnostic procedure volumes, centres practice and protocols, and staff members' well-being 1 year after COVID-19 outbreak in Italy. Methods and results: A global survey was conducted by the International Atomic Energy Agency to evaluate changes in cardiac diagnostic procedure volumes in April 2021. Evaluated procedures were transoesophageal echocardiogram, coronary computed tomography angiography, coronary artery calcium scanning, nuclear medicine infection studies, invasive coronary angiography, rest and stress transthoracic echocardiogram, cardiac magnetic resonance, single-photon emission computed tomography and positron emission tomography, and stress electrocardiogram. Data were compared with April 2020 and March 2019. Forty-two Italian centres took part in the survey. In April 2020, there was a 72% decrease of median volumes of cardiac diagnostic procedures compared with March 2019. In April 2021, volumes of cardiac diagnostic procedures remained decreased by 3% when compared with March 2019. Stress electrocardiogram, coronary computed tomography angiography, and stress cardiac magnetic resonance volumes increased in April 2021 compared with baseline (29%, 6%, and 16%, respectively). The majority of centres had adopted physical distancing measures (93%), COVID-19 screening through questionnaires (76%), or temperature checks (93%). Twenty-five per cent of physicians at Italian responding sites reported excessive levels of psychological stress. Conclusion: In April 2021, volumes of cardiac diagnostic procedures at Italian responding sites were still recovering. Centres had implemented several adaptations to ensure the provision of care to their patients. Even 1 year after the pandemic, a substantial minority of Italian healthcare providers were still experiencing excessive psychological stress.
The coronavirus disease-2019 pandemic has had an impact on cardiovascular care provision, leading to a decrease in the number of diagnostic procedures performed. As of April 2021, volumes of cardiovascular diagnostic procedures in Italy were still recovering, despite the implementation of several adaptations by healthcare centres to deal with the pandemic.
RESUMEN
Purpose: To characterize the recovery of diagnostic cardiovascular procedure volumes in U.S. and non-U.S. facilities in the year following the initial COVID-19 outbreak. Materials and Methods: The International Atomic Energy Agency (IAEA) coordinated a worldwide study called the IAEA Noninvasive Cardiology Protocols Study of COVID-19 2 (INCAPS COVID 2), collecting data from 669 facilities in 107 countries, including 93 facilities in 34 U.S. states, to determine the impact of the pandemic on diagnostic cardiovascular procedure volumes. Participants reported volumes for each diagnostic imaging modality used at their facility for March 2019 (baseline), April 2020, and April 2021. This secondary analysis of INCAPS COVID 2 evaluated differences in changes in procedure volume between U.S. and non-U.S. facilities and among U.S. regions. Factors associated with return to prepandemic volumes in the United States were also analyzed in a multivariable regression analysis. Results: Reduction in procedure volumes in April 2020 compared with baseline was similar for U.S. and non-U.S. facilities (-66% vs -71%, P = .27). U.S. facilities reported greater return to baseline in April 2021 than did all non-U.S. facilities (4% vs -6%, P = .008), but there was no evidence of a difference when comparing U.S. facilities with non-U.S. high-income country (NUHIC) facilities (4% vs 0%, P = .18). U.S. regional differences in return to baseline were observed between the Midwest (11%), Northeast (9%), South (1%), and West (-7%, P = .03), but no studied factors were significant predictors of 2021 change from prepandemic baseline. Conclusion: The reductions in cardiac testing during the early pandemic have recovered within a year to prepandemic baselines in the United States and NUHICs, while procedure volumes remain depressed in lower-income countries.Keywords: SPECT, Cardiac, Epidemiology, Angiography, CT Angiography, CT, Echocardiography, SPECT/CT, MR Imaging, Radionuclide Studies, COVID-19, Cardiovascular Imaging, Diagnostic Cardiovascular Procedure, Cardiovascular Disease, Cardiac Testing Supplemental material is available for this article. © RSNA, 2023.
RESUMEN
BACKGROUND: The extent to which health care systems have adapted to the COVID-19 pandemic to provide necessary cardiac diagnostic services is unknown. OBJECTIVES: The aim of this study was to determine the impact of the pandemic on cardiac testing practices, volumes and types of diagnostic services, and perceived psychological stress to health care providers worldwide. METHODS: The International Atomic Energy Agency conducted a worldwide survey assessing alterations from baseline in cardiovascular diagnostic care at the pandemic's onset and 1 year later. Multivariable regression was used to determine factors associated with procedure volume recovery. RESULTS: Surveys were submitted from 669 centers in 107 countries. Worldwide reduction in cardiac procedure volumes of 64% from March 2019 to April 2020 recovered by April 2021 in high- and upper middle-income countries (recovery rates of 108% and 99%) but remained depressed in lower middle- and low-income countries (46% and 30% recovery). Although stress testing was used 12% less frequently in 2021 than in 2019, coronary computed tomographic angiography was used 14% more, a trend also seen for other advanced cardiac imaging modalities (positron emission tomography and magnetic resonance; 22%-25% increases). Pandemic-related psychological stress was estimated to have affected nearly 40% of staff, impacting patient care at 78% of sites. In multivariable regression, only lower-income status and physicians' psychological stress were significant in predicting recovery of cardiac testing. CONCLUSIONS: Cardiac diagnostic testing has yet to recover to prepandemic levels in lower-income countries. Worldwide, the decrease in standard stress testing is offset by greater use of advanced cardiac imaging modalities. Pandemic-related psychological stress among providers is widespread and associated with poor recovery of cardiac testing.
Asunto(s)
COVID-19 , COVID-19/epidemiología , Atención a la Salud , Personal de Salud , Humanos , Pandemias , Encuestas y CuestionariosRESUMEN
BACKGROUND: The COVID-19 pandemic has disrupted the delivery of care for cardiovascular diseases in Latin America. However, the effect of the pandemic on the cardiac diagnostic procedure volumes has not been quantified. OBJECTIVE: To assess (1) the impact of COVID-19 on cardiac diagnostic volumes in Latin America and (2) determine its relationship with COVID-19 case incidence and social distancing measures. METHODS: The International Atomic Energy Agency conducted a worldwide survey assessing changes in cardiac diagnostic volumes resulting from COVID-19. Cardiac diagnostic volumes were obtained from participating sites for March and April 2020 and compared to March 2019. Social distancing data were collected from Google COVID-19 community mobility reports and COVID-19 incidence per country from the Our World in Data. RESULTS: Surveys were conducted in 194 centers performing cardiac diagnostic procedures, in 19 countries in Latin America. Procedure volumes decreased 36% from March 2019 to March 2020, and 82% from March 2019 to April 2020. The greatest decreases occurred in echocardiogram stress tests (91%), exercise treadmill tests (88%), and computed tomography calcium scores (87%), with slight variations between sub-regions of Latin America. Changes in social distancing patterns (p < 0.001) were more strongly associated with volume reduction than COVID-19 incidence (p = 0.003). CONCLUSIONS: COVID-19 was associated with a significant reduction in cardiac diagnostic procedures in Latin America, which was more related to social distancing than to the COVID-19 incidence. Better balance and timing of social distancing measures and planning to maintain access to medical care is warranted during a pandemic surge, especially in regions with high cardiovascular mortality.
FUNDAMENTO: A pandemia de COVID-19 interferiu na prestação de atendimento a doenças cardiovasculares na América Latina. No entanto, o efeito da pandemia nos volumes de procedimentos cardíacos diagnósticos ainda não foi quantificado. OBJETIVO: Avaliar (1) o impacto de COVID-19 nos volumes de diagnóstico cardíaco na América Latina e (2) determinar sua relação com a incidência de casos de COVID-19 e as medidas de distanciamento social. MÉTODOS: A International Atomic Energy Agency realizou uma pesquisa mundial avaliando mudanças nos volumes diagnósticos cardíacos decorrentes da COVID-19. Foram obtidos os volumes diagnósticos cardíacos dos locais participantes para março e abril de 2020 e comparados com março de 2019. Foram coletados dados de distanciamento social a partir dos Relatórios de mobilidade da comunidade de Google e a incidência de COVID-19 por país a partir de Our World in Data. RESULTADOS: Foram realizadas pesquisas em 194 centros que realizam procedimentos diagnósticos cardíacos, em 19 países da América Latina. Em comparação com o mês de março de 2019, os volumes dos procedimentos diagnósticos cardíacos diminuíram 36% em março de 2020 e 82% em abril de 2020.As maiores reduções ocorreram em relação aos testes de estresse ecocardiográfico (91%), testes ergométricos de esteira (88%) e escore de cálcio por tomografia computadorizada (87%), com pequenas variações entre as sub-regiões da América Latina. As mudanças em padrões de distanciamento social (p < 0,001) estavam mais fortemente associadas com a redução do volume do que a incidência de COVID-19 (p = 0,003). CONCLUSÕES: A COVID-19 foi associada a uma redução significativa de procedimentos diagnósticos cardíacos na América Latina, a qual foi mais relacionada ao distanciamento social do que ao aumento da incidência da COVID-19. São necessários melhor equilíbrio e timing de medidas de distanciamento social e planejamento para manter o acesso ao atendimento médico durante um surto pandêmico, especialmente em regiões com alta mortalidade cardiovascular.
Asunto(s)
COVID-19 , Cardiopatías , COVID-19/diagnóstico , COVID-19/epidemiología , Cardiopatías/epidemiología , Humanos , América Latina/epidemiología , Pandemias , Encuestas y CuestionariosRESUMEN
BACKGROUND: In early 2020, COVID-19 massively hit Italy, earlier and harder than any other European country. This caused a series of strict containment measures, aimed at blocking the spread of the pandemic. Healthcare delivery was also affected when resources were diverted towards care of COVID-19 patients, including intensive care wards. AIM OF THE STUDY: The aim is assessing the impact of COVID-19 on cardiac imaging in Italy, compare to the Rest of Europe (RoE) and the World (RoW). METHODS: A global survey was conducted in May-June 2020 worldwide, through a questionnaire distributed online. The survey covered three periods: March and April 2020, and March 2019. Data from 52 Italian centres, a subset of the 909 participating centres from 108 countries, were analyzed. RESULTS: In Italy, volumes decreased by 67% in March 2020, compared to March 2019, as opposed to a significantly lower decrease (p < 0.001) in RoE and RoW (41% and 40%, respectively). A further decrease from March 2020 to April 2020 summed up to 76% for the North, 77% for the Centre and 86% for the South. When compared to the RoE and RoW, this further decrease from March 2020 to April 2020 in Italy was significantly less (p = 0.005), most likely reflecting the earlier effects of the containment measures in Italy, taken earlier than anywhere else in the West. CONCLUSIONS: The COVID-19 pandemic massively hit Italy and caused a disruption of healthcare services, including cardiac imaging studies. This raises concern about the medium- and long-term consequences for the high number of patients who were denied timely diagnoses and the subsequent lifesaving therapies and procedures.
Asunto(s)
COVID-19 , Cardiología , Humanos , Italia/epidemiología , Pandemias , SARS-CoV-2 , Encuestas y CuestionariosRESUMEN
Background: The coronavirus disease-2019 (COVID-19) pandemic significantly affected management of cardiovascular disease around the world. The effect of the pandemic on volume of cardiovascular diagnostic procedures is not known. Objectives: This study sought to evaluate the effects of the early phase of the COVID-19 pandemic on cardiovascular diagnostic procedures and safety practices in Asia. Methods: The International Atomic Energy Agency conducted a worldwide survey to assess changes in cardiovascular procedure volume and safety practices caused by COVID-19. Testing volumes were reported for March 2020 and April 2020 and were compared to those from March 2019. Data from 180 centers across 33 Asian countries were grouped into 4 subregions for comparison. Results: Procedure volumes decreased by 47% from March 2019 to March 2020, showing recovery from March 2020 to April 2020 in Eastern Asia, particularly in China. The majority of centers cancelled outpatient activities and increased time per study. Practice changes included implementing physical distancing and restricting visitors. Although COVID testing was not commonly performed, it was conducted in one-third of facilities in Eastern Asia. The most severe reductions in procedure volumes were observed in lower-income countries, where volumes decreased 81% from March 2019 to April 2020. Conclusions: The COVID-19 pandemic in Asia caused significant reductions in cardiovascular diagnostic procedures, particularly in low-income countries. Further studies on effects of COVID-19 on cardiovascular outcomes and changes in care delivery are warranted.
RESUMEN
OBJECTIVES: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED). BACKGROUND: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED. RESULTS: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv. CONCLUSIONS: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions.