RESUMEN
PURPOSE: To study the biomechanical characteristics (percent stretch, stiffness, and ultimate load) of 2 distal fixation techniques for an active tendon implant used in the reconstruction of flexor tendons. METHODS: We evaluated percent stretch after cyclical loading and at failure, stiffness during load-to-failure, and peak load of 28 bone-prosthesis junctions using cadaveric canine middle phalanges to study 2 fixation techniques: metal cleat and screw versus polyester cords secured with a knot. RESULTS: The knot constructs displayed greater percent stretch during and following cyclical loading between 2 N and 50 N and at peak load. The screw construct showed greater stiffness from 50 N to 150 N during load-to-failure. Both fixation techniques failed at a mean peak load greater than 340 N. CONCLUSIONS: Both fixation techniques for active tendon implants withstood loads seen with passive and active motion in the immediate postoperative period. Knot constructs displayed significant stretch during cyclical and load-to-failure testing, which would need to be compensated for during surgery. The screw constructs showed greater stiffness than the constructs secured with the surgeon's knot, but failure created an intra-articular fracture. CLINICAL RELEVANCE: The results may aid the surgeon in choosing which fixation technique to use, during tensioning of cords, and in permitting active motion following surgery.
Asunto(s)
Tornillos Óseos , Anclas para Sutura , Traumatismos de los Tendones/cirugía , Tenodesis/métodos , Animales , Perros , Ensayo de Materiales , Soporte de PesoRESUMEN
OBJECTIVES: To determine the early implant failure rate of a novel retrograde intramedullary femoral nail. DESIGN: Retrospective cohort study. SETTING: Academic level 1 trauma center. PATIENTS SELECTION CRITERIA: Patients aged 18 years and older with an acute OTA/AO 32-A, 32-B, 32-C, and 33-A fractures or periprosthetic distal femur fracture from April 2018 to April 2022 were included in the study. The 2 interventions compared were the Synthes Expert retrograde/antegrade femoral nail (or control implant) versus the next-generation retrograde femoral nail (RFN)-advanced retrograde femoral nail (RFNA or experimental implant) (Synthes, West Chester, PA). OUTCOME MEASURES AND COMPARISONS: Early implant-related complications between the experimental and control implants were assessed including locking screw back out, screw breakage, intramedullary nail failure, need for secondary surgery, and loss of fracture reduction. RESULTS: Three hundred fourteen patients were identified with a mean age of 31.0 years, and 62.4% of the patients being male. Open fractures occurred in 32.5% of patients with 3.8% of injuries being distal femur periprosthetic fractures. Fifty-six patients were in the experimental group and 258 patients in the control group. Mean follow-up was 46.8 weeks for the control cohort and 21.0 weeks for the experimental cohort. Distal interlocking screw back out occurred in 23.2% (13 of 56) of the experimental group patients and 1.9% (5 of 258) of the control group patients ( P < 0.0001). Initial diagnosis of interlocking screw back out occurred at an average of 3.2 weeks postoperatively (range, 2-12 weeks). Fifty-four percent of patients who sustained screw back out underwent a secondary operation to remove the symptomatic screws (12.5% of all patients treated with the experimental implant required an unplanned secondary operation due to screw back out). A logistic regression model was used to predict screw back out and found the experimental implant group was 4.3 times as likely to experience distal locking screw back out compared with the control group ( P = 0.01). CONCLUSIONS: The retrograde femoral nail-advanced implant was associated with a significantly higher rate of screw back out with a substantial number of unplanned secondary surgeries compared with the previous generation of this implant. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)
Clavos Ortopédicos , Fracturas del Fémur , Fijación Intramedular de Fracturas , Humanos , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Masculino , Femenino , Estudios Retrospectivos , Adulto , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Persona de Mediana Edad , Adulto Joven , Estudios de Cohortes , AncianoRESUMEN
Objectives: Tibial shaft fractures are treated with both intramedullary nailing (IMN) and plate fixation (ORIF). Using a large national database, we aimed to explore the differences in thirty-day complication rates between IMN and ORIF. Methods: Patients in the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database who had undergone either tibial IMN or ORIF for closed fractures from 2010 to 2018 were identified using current procedural terminology (CPT) codes. After excluding all patients with open fractures, the propensity score was matching. Univariate and multivariate logistic regressions were used to identify risk factors associated with the thirty-day incidence of complications in the two cohorts. Results: A total of 5,400 patients were identified with 3,902 (72.3%) undergoing IMN and 1,498 (27.7%) ORIF. After excluding any ICD-10 diagnosis codes not pertaining to closed, traumatic tibial shaft fractures, 2,136 IMN and 621 ORIF cases remained. After matching, the baseline demographics were not significantly different between the cohorts. Following matching, the rate of any adverse event (aae) did not differ significantly between the IMN (7.08% (n = 44)) and ORIF (8.86% (n = 55)) cohorts (p=0.13). There was also no significant difference in operative time (IMN = 98.5 min, ORIF = 100 min; p=0.3) or length of stay (IMN = 3.7 days, ORIF = 3.3 days; p=0.08) between the cohorts. Conclusion: There were no significant differences in short-term complications between cohorts. These are important data for the surgeon when considering surgical management of closed tibial shaft fractures.
RESUMEN
OBJECTIVE: (1) To assess the rate of fracture-related infection (FRI) and unplanned reoperation of disinfecting and prepping in the external fixator (Ex-Fix) instrument during definitive open reduction and internal fixation (ORIF) of pilon fractures treated by a staged protocol and (2) to determine whether the amount of time from external fixation to ORIF influences the risk of FRI. DESIGN: Retrospective cohort study. SETTING: Level 1 academic trauma center. PATIENTS: One hundred thirty-three patients who underwent operative treatment for pilon fracture between 2010 and 2020. INTERVENTION: External fixation and ORIF with or without the Ex-Fix prepped in situ during definitive fixation. MAIN OUTCOME MEASUREMENTS: FRI and unplanned reoperation rates. RESULTS: 133 patients were enrolled, of which 47 (35.3%) had Ex-Fix elements prepped in situ. There was an overall infection rate of 23.3% and unplanned reoperation rate of 11.3%, and there was no significant difference in rates between the 2 cohorts. Patients with Ex-Fix elements prepped in situ who developed an FRI had a higher rate of MRSA and MSSA . Diabetes ( P = 0.0019), open fracture ( P = 0.0014), and longer (≥30 days) interval to ORIF ( P = 0.0001) were associated with postoperative FRI. CONCLUSIONS: Prepping elements of the Ex-Fix in situ did not lead to an increase in rates of FRI or unplanned reoperation. Although diabetes and open fracture were associated with FRI risk, a stronger association was a longer interval of Ex-Fix utilization before definitive internal fixation, specifically 30 days or greater. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)
Fracturas de Tobillo , Fracturas Abiertas , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Fracturas Abiertas/cirugía , Fracturas Abiertas/etiología , Estudios de Cohortes , Resultado del Tratamiento , Infección de la Herida Quirúrgica/epidemiología , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/etiología , Fijación Interna de Fracturas/métodos , Fijadores Externos , Fracturas de Tobillo/cirugía , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/etiologíaRESUMEN
OBJECTIVE: To determine patient-specific and injury-specific factors that may predict infection and other adverse clinical results in the setting of tibial pilon fractures. DESIGN: Retrospective chart review. SETTING: Level 1 academic trauma center. PATIENTS: Two hundred forty-eight patients who underwent operative treatment for tibial pilon fractures between 2010 and 2020. INTERVENTION: External fixation and/or open reduction and internal fixation. MAIN OUTCOME MEASUREMENTS: Fracture-related infection rates and specific bacteriology, risk factors associated with development of a fracture-related infection, and predictors of adverse clinical results. RESULTS: Two hundred forty-eight patients were enrolled. There was an infection rate of 21%. The 3 most common pathogens cultured were methicillin-resistant Staphylococcus aureus (20.3%), Enterobacter cloacae (16.7%), and methicillin-resistant Staphylococcus aureus (15.5%). There was no significant difference in age, sex, race, body mass index, or smoking status between those who developed an infection and those who did not. Patients with diabetes mellitus ( P = 0.0001), open fractures ( P = 0.0043), and comminuted fractures (OTA/AO 43C2 and 43C3) ( P = 0.0065) were more likely to develop a fracture-related infection. The presence of a polymicrobial infection was positively associated with adverse clinical results ( P = 0.006). History of diabetes was also positively associated with adverse results ( P = 0.019). CONCLUSIONS: History of diabetes and severe fractures, such as those that were open or comminuted fractures, were positively associated with developing a fracture-related infection after the operative fixation of tibial pilon fractures. History of diabetes and presence of a polymicrobial infection were independently associated with adverse clinical results. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)
Fracturas de Tobillo , Coinfección , Fracturas Conminutas , Fracturas Abiertas , Staphylococcus aureus Resistente a Meticilina , Fracturas de la Tibia , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fracturas Abiertas/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Fracturas de la Tibia/cirugía , Resultado del TratamientoRESUMEN
Posterior wall acetabulum fractures typically result from high-energy mechanisms and can be associated with various orthopaedic and nonorthopaedic injuries. They range from isolated simple patterns to multifragmentary with or without marginal impaction. Determination of hip stability, which can depend on fragment location, size, and displacement, directs management. Although important in the assessment of posterior wall fractures, CT is unreliable when used to determine stability. The dynamic fluoroscopic examination under anesthesia (EUA) is the benchmark in assessment of hip stability, and fractures deemed stable by EUA have good radiographic and functional outcomes. In fractures that meet surgical criteria, accurate joint reduction guides outcomes. Joint débridement, identification and elevation of impaction, and adjunctive fixation of posterosuperior and peripheral rim fragments along with standard buttress plate fixation are critical. Complications of the fracture and surgical fixation include sciatic nerve injury, posttraumatic osteoarthritis, osteonecrosis of the femoral head, and heterotopic ossification. Although accuracy of joint reduction is paramount for successful results, other factors out of the surgeon's control such as comminution, femoral head lesions, and dislocation contribute to poor outcomes. Even with anatomic restoration of the joint surface, good clinical outcomes are not guaranteed and residual functional deficits can be expected.
Asunto(s)
Fracturas Óseas , Luxaciones Articulares , Acetábulo/diagnóstico por imagen , Placas Óseas , Fijación Interna de Fracturas , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Humanos , Resultado del TratamientoRESUMEN
CASE: A 62-year-old man without significant medical history (no anticoagulation) presented to the emergency department with intense leg pain following a short track race, during which he felt a pop in his calf. His physical exam was highly concerning for acute compartment syndrome (ACS) despite the lack of a typical mechanism or fracture. Compartment pressures were measured and found to be significantly elevated. He underwent compartment releases revealing a medial soleus tear with 400-500 cc hematoma. CONCLUSION: The case presents a patient with ACS after a soleus muscle tear. Prompt recognition and fasciotomy led to a good clinical outcome. Physicians should recognize that not only gastrocnemius tears can lead to compartment syndrome.
RESUMEN
OBJECTIVES: (1) Evaluate intentional temporary limb deformation for closure of soft-tissue defects as a reconstruction strategy in open tibia fractures and (2) analyze the deformity parameters required for such reconstruction. DESIGN: Multicenter retrospective cohort. SETTING: Level I trauma center. PATIENTS/PARTICIPANTS: Nineteen patients 18 years of age and older at the time of initial trauma, with a Gustilo-Anderson type IIIB or IIIC open tibia fracture treated with hexapod external fixation and intentional bony deformity created to facilitate soft-tissue closure. INTERVENTION: Intentional limb deformation for soft-tissue closure, followed by gradual correction with a hexapod external fixator. OUTCOME MEASUREMENTS: Radiographic healing, radiographic assessment of limb alignment, and functional and bony Application of the Method of Ilizarov Group score. RESULTS: The average age was 45.3 (20-70), and 79% of patients were men. The most common mechanism of injury was motor vehicle accidents. The distal 1 of 5 of the tibia was the most common fracture location, with 37% of these involving the articular surface at the plafond. After wound closure, deformity correction was initiated after 30 days on average. Varus and apex posterior were the most common initial deformity required for primary soft-tissue closure. Bony and functional Application of the Method of Ilizarov Group outcomes were good or excellent in 94% of patients. CONCLUSION: Intentional deformation followed by a gradual correction can be an effective strategy to obtain bone union and soft-tissue coverage in certain open fractures. This technique, in essence, converts these injuries from type IIIB to IIIA. This strategy obviates the need for flap coverage and results in satisfactory outcomes. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Asunto(s)
Fracturas Abiertas , Fracturas de la Tibia , Adolescente , Adulto , Fijadores Externos , Femenino , Fracturas Abiertas/diagnóstico por imagen , Fracturas Abiertas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tibia , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del TratamientoRESUMEN
INTRODUCTION: High-energy mechanisms of acetabular fracture in the geriatric population are becoming increasingly common as older adults remain active later in life. This study compared outcomes for high- versus low-energy acetabular fractures in older adults. MATERIALS AND METHODS: We studied outcomes of 22 older adults with acetabular fracture who were treated at a level-I trauma center over a 4-year period. Fourteen patients were categorized as low-energy mechanism of injury, and 8 were identified as a high-energy mechanism. We analyzed patient demographics with univariate logistic regressions performed to assess differences in high- and low-energy group as well as patient characteristics compared with surgical outcomes. RESULTS: Most high-energy mechanisms were caused by motor vehicle collision (n = 4, 50.0%), with most having posterior wall fractures (50.0%). Among patient characteristics, the mechanism of injury, hip dislocation, fracture types, and fracture gap had the largest differences between energy groups effect size (ES: 2.45, 1.43, 1.36, and 0.83, respectively). The high-energy group was more likely to require surgery (odds ratio [OR] = 2.80, 95% CI: 0.26-30.70), develop heterotopic bone (OR = 4.33, 95% CI: 0.33-57.65), develop arthritis (OR = 3.60, 95% CI: 0.45-28.56), and had longer time to surgery (mean = 4.8 days, standard deviation [SD] = 5.8 days) compared to low-energy group (mean = 2.5 days, SD = 2.3 days). DISCUSSION: The results of this case series confirm previous findings that patients with high-energy acetabular fractures are predominantly male, younger, and have fewer comorbidities than those who sustained low-energy fractures. Our results demonstrate that the majority of the high-energy fracture patients also suffered a concurrent hip dislocation with posterior wall fracture and experienced a longer time to surgery than the low-energy group. CONCLUSION: Geriatric patients who sustained high-energy acetabular fractures tend to have higher overall rates of complications, including infection, traumatic arthritis, and heterotopic bone formation when compared with patients with a low-energy fracture mechanism.