Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 426
Filtrar
1.
BJU Int ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38994628

RESUMEN

OBJECTIVES: To assess laser-tissue interactions through ablation, coagulation, and carbonisation characteristics in a non-perfused porcine kidney model between three pulsed lasers: holmium (Ho): yttrium-aluminium-garnet (YAG), thulium fiber laser (TFL), and pulsed thulium (p-Tm):YAG. MATERIALS AND METHODS: A 150-W Ho:YAG, a 60-W TFL, and a 100-W p-Tm:YAG lasers were compared. The laser settings that can be set identically between the three lasers and be clinically relevant for prostate laser enucleation were identified and used on fresh, unfrozen porcine kidneys. Laser incisions were performed using stripped laser fibers of 365 and 550 µm, set at distances of 0 and 1 mm from the tissue surface at a constant speed of 2 mm/s. Histological analysis evaluated shape, depth, width of the incision, axial coagulation depth, and presence of carbonisation. RESULTS: Incision depths, widths, and coagulation zones were greater with Ho:YAG and p-Tm:YAG lasers than TFL. Although no carbonisation was found with the Ho:YAG and p-Tm:YAG lasers, it was common with TFL, especially at high frequencies. The shapes of the incisions and coagulation zones were more regular and homogeneous with the p-Tm:YAG laser and TFL than with Ho:YAG laser. Regardless of the laser used, short pulse durations resulted in deeper incisions than long pulse durations. Concerning the distance, we found that to be effective, TFL had to be used in contact with the tissue. Finally, 365-µm fibers resulted in deeper incisions, while 550-µm fibers led to wider incisions and larger coagulation zones. CONCLUSION: Histological analysis revealed greater tissue penetration with the p-Tm:YAG laser compared to the TFL, while remaining less than with Ho:YAG. Its coagulation properties seem interesting insofar as it provides homogeneous coagulation without carbonisation, while incisions remained uniform without tissue laceration. Thus, the p-Tm:YAG laser appears to be an effective alternative to Ho:YAG and TFL lasers in prostate surgery.

2.
BJU Int ; 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38813615

RESUMEN

OBJECTIVE: To perform a collaborative review of the literature exploring the microsatellite instability/deficient mismatch repair (MSI/dMMR) phenotype in patients with upper tract urothelial carcinoma (UTUC). METHOD: A collaborative review of the literature available on Medline was conducted by the Cancer Committee of the French Association of Urology to report studies describing the genetic mechanisms, investigation, prevalence and impact of the MSI/dMMR phenotype in UTUC patients. RESULTS: The predominant genetic mechanism leading to the MSI/dMMR phenotype in UTUC patients is related to the constitutional mutation of one allele of the MMR genes MLH1, MSH2, MSH6 and PMS2 within Lynch syndrome. Indications for its investigation currently remain limited to patients with a clinical suspicion for sporadic UTUC to refer only those with a positive testing for germline DNA sequencing to screen for this syndrome. With regard to technical aspects, despite the interest of MSIsensor, only PCR and immunohistochemistry are routinely used to somatically investigate the MSI and dMMR phenotypes, respectively. The prevalence of the MSI/dMMR phenotype in UTUC patients ranges from 1.7% to 57%, depending on the study population, investigation method and definition of a positive test. Younger age and a more balanced male to female ratio at initial diagnosis are the main specific clinical characteristics of UTUC patients with an MSI/dMMR phenotype. Despite the conflicting results available in the literature, these patients may have a better prognosis, potentially related to more favourable pathological features. Finally, they may also have lower sensitivity to chemotherapy but greater sensitivity to immunotherapy. CONCLUSION: Our collaborative review summarises the available data from published studies exploring the MSI/dMMR phenotype in UTUC patients, the majority of which are limited by a low level of evidence.

3.
World J Urol ; 42(1): 280, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693433

RESUMEN

OBJECTIVE: To perform a comprehensive narrative review that will examine the risk factors and treatment outcomes of arterial pseudoaneurysm following laser flexible ureteroscopy (F-URS). METHODS: A retrospective case series and a review of literature was performed. Clinical records from three patients treated for postoperative arterial pseudoaneurysm from January of 2021 to November 2023 were identified. A comprehensive literature review was also performed. The MEDLINE and Scopus databases were searched. The analysis was made by a narrative synthesis. RESULTS: Three cases of postoperative arterial pseudoaneurysm were included, one from our center, one from Dubai, UAE, and one from Barcelona. The literature review identified six case reports, two after endocorporeal laser lithotripsy with thulium fiber laser (TFL) and four with Ho:YAG laser. All cases, from our series and literature review, presented with macroscopic hematuria and used high-power laser settings. All cases were treated by selective embolization. CONCLUSION: Ho:YAG or TFL lasers are both capable of causing arterial pseudoaneurysms following F-URS if high-power settings are used. Selective artery embolization continues to be the treatment of choice with good outcomes.


Asunto(s)
Aneurisma Falso , Litotripsia por Láser , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Litotripsia por Láser/efectos adversos , Litotripsia por Láser/métodos , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Ureteroscopía/efectos adversos , Adulto
4.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38478094

RESUMEN

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Asunto(s)
Cálculos Renales , Láseres de Estado Sólido , Litotripsia por Láser , Litotricia , Humanos , Tulio/uso terapéutico , Litotripsia por Láser/métodos , Cálculos Renales/cirugía
5.
World J Urol ; 42(1): 388, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985297

RESUMEN

PURPOSE: We assessed the impact of the one-year endourological society fellowship program (ESFP) on the achievement of optimal surgical outcomes (OSO) in stone patients treated with ureteroscopy (URS). MATERIALS AND METHODS: We identified 303 stone patients treated with URS from January 2018 to June 2022 by five experienced surgeons (ES). Of those, two attended ESFP. OSO was defined as the presence of residual fragments ≤ 4 mm at 1-month post-operative imaging (Ultrasound + X - Ray or CT scan). Descriptive statistics explored patients' characteristics and the rate of OSO according to the attendance of ESFP. Uni- and multivariate logistic regression analyses (UVA and MVA) tested the impact of stone characteristics, surgical data, ESFP, and imaging technique on the rate of OSO. The LOWESS curve explored the graphical association between stone size and the multivariable-adjusted probability of OSO in the two groups of surgeons. RESULTS: Of 303 patients, 208 (69%) were treated by the two surgeons who attended ESFP. OSO was achieved in 66% and 52% of patients treated by ES with and without ESFP, respectively (p = 0.01). At UVA, ESFP (OR = 1.78; 95% CI = 1.09-2.90), stone diameter (OR = 0.92; 95% CI = 0.88-0.96), stone location (kidney vs. ureter; OR = 0.34; 95% CI = 0.21-0.58), imaging technique (CT scan vs. Ultrasound + X-Ray; OR = 0.28; 95% CI = 0.16-0.47) predicted OSO achievement (all p < 0.05). At MVA analyses, ESFP was associated with OSO (OR = 2.24; 95% CI = 1.29-3.88; p < 0.05), along with the other aforementioned variables. The LOWESS curve showed that the greater the stone size, the greater the difference in OSO in the two groups of surgeons. CONCLUSIONS: ESFP positively affects OSO achievement after URS, especially in patients with a high stone burden.


Asunto(s)
Becas , Cálculos Ureterales , Ureteroscopía , Urología , Humanos , Femenino , Persona de Mediana Edad , Masculino , Urología/educación , Resultado del Tratamiento , Estudios Retrospectivos , Cálculos Ureterales/cirugía , Cálculos Ureterales/diagnóstico por imagen , Cálculos Renales/cirugía , Cálculos Renales/diagnóstico por imagen , Adulto , Sociedades Médicas , Anciano
6.
World J Urol ; 42(1): 292, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38704492

RESUMEN

PURPOSE: During endoscopic stone surgery, Holmium:YAG (Ho:YAG) and Thulium Fiber Laser (TFL) technologies allow to pulverize urinary stones into fine particles, ie DUST. Yet, currently there is no consensus on the exact definition of DUST. This review aimed to define stone DUST and Clinically Insignificant Residual Fragments (CIRF). METHODS: Embase, MEDLINE (PubMed) and Cochrane databases were searched for both in vitro and in vivo articles relating to DUST and CIRF definitions, in November 2023, using keyword combinations: "dust", "stones", "urinary calculi", "urolithiasis", "residual fragments", "dusting", "fragments", "lasers" and "clinical insignificant residual fragments". RESULTS: DUST relates to the fine pulverization of urinary stones, defined in vitro as particles spontaneously floating with a sedimentation duration ≥ 2 sec and suited for aspiration through a 3.6Fr-working channel (WC) of a flexible ureteroscope (FURS). Generally, an upper size limit of 250 µm seems to agree with the definition of DUST. Ho:YAG with and without "Moses Technology", TFL and the recent pulsed-Thulium:YAG (pTm:YAG) can produce DUST, but no perioperative technology can currently measure DUST size. The TFL and pTm:YAG achieve better dusting compared to Ho:YAG. CIRF relates to residual fragments (RF) that are not associated with imminent stone-related events: loin pain, acute renal colic, medical or interventional retreatment. CIRF size definition has decreased from older studies based on Shock Wave Lithotripsy (SWL) (≤ 4 mm) to more recent studies based on FURS (≤ 2 mm) and Percutaneous Nephrolithotomy(PCNL) (≤ 4 mm). RF ≤ 2 mm are associated with lower stone recurrence, regrowth and clinical events rates. While CIRF should be evaluated postoperatively using Non-Contrast Computed Tomography(NCCT), there is no consensus on the best diagnostic modality to assess the presence and quantity of DUST. CONCLUSION: DUST and CIRF refer to independent entities. DUST is defined in vitro by a stone particle size criteria of 250 µm, translating clinically as particles able to be fully aspirated through a 3.6Fr-WC without blockage. CIRF relates to ≤ 2 RF on postoperative NCCT.


Asunto(s)
Ureteroscopía , Cálculos Urinarios , Humanos , Cálculos Urinarios/terapia , Litotripsia por Láser/métodos , Polvo , Tamaño de la Partícula
7.
World J Urol ; 42(1): 266, 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38676726

RESUMEN

PURPOSE: Considering the existing gaps in the literature regarding patient radiation dose (RD) and its associated risks, a systematic review of the literature on RD was conducted, focusing on percutaneous nephrolithotomy (PCNL), extracorporeal shock wave lithotripsy (SWL), and ureteroscopy (URS). METHODS: Two authors conducted a literature search on PubMed, Web of Science, and Google Scholar to identify studies on RD during endourological procedures. Two thousand two hundred sixty-six articles were screened. Sixty-five publications met the inclusion criteria using the PRISMA standards. RESULTS: RD was generally highest for PCNL, reaching levels up to 33 mSv, 28,700 mGycm2, and 430.8 mGy. This was followed by SWL, with RD reaching up to 7.32 mSv, 13,082 mGycm2, and 142 mGy. URS demonstrated lower RD, reaching up to 6.07 mSv, 8920 mGycm2, and 46.99 mGy. Surgeon experience and case load were inversely associated with RD. Strategies such as optimizing fluoroscopy settings, implementing ultrasound (US), and following the ALARA (As Low As Reasonably Achievable) principle minimized RD. CONCLUSIONS: This is the first systematic review analyzing RD, which was generally highest during PCNL, followed by SWL and URS. There is no specific RD limit for these procedures. Implementation of strategies such as optimizing fluoroscopy settings, utilizing US, and adhering to the ALARA principle proved effective in reducing RD. However, further research is needed to explore the factors influencing RD, assess their impact on patient outcomes, and establish procedure-specific reference levels for RD.


Asunto(s)
Litotricia , Nefrolitotomía Percutánea , Exposición a la Radiación , Ureteroscopía , Humanos , Ureteroscopía/efectos adversos , Nefrolitotomía Percutánea/efectos adversos , Nefrolitotomía Percutánea/métodos , Litotricia/efectos adversos , Litotricia/métodos , Dosis de Radiación
8.
World J Urol ; 42(1): 46, 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38244083

RESUMEN

PURPOSE: Urolithiasis has become increasingly prevalent, leading to higher disability-adjusted life years and deaths. Various stone classification systems have been developed to enhance the understanding of lithogenesis, aid urologists in treatment decisions, and predict recurrence risk. The aim of this manuscript is to provide an overview of different stone classification criteria. METHODS: Two authors conducted a review of literature on studies relating to the classification of urolithiasis. A narrative synthesis for analysis of the studies was used. RESULTS: Stones can be categorized based on anatomical position, size, medical imaging features, risk of recurrence, etiology, composition, and morphoconstitutional analysis. The first three mentioned offer a straightforward approach to stone classification, directly influencing treatment recommendations. With the routine use of CT imaging before treatment, precise details like anatomical location, stone dimensions, and Hounsfield Units can be easily determined, aiding treatment planning. In contrast, classifying stones based on risk of recurrence and etiology is more complex due to dependencies on multiple variables, including stone composition and morphology. A classification system based on morphoconstitutional analysis, which combines morphological stone appearance and chemical composition, has demonstrated its value. It allows for the rapid identification of crystalline phase principles, the detection of crystalline conversion processes, the determination of etiopathogenesis, the recognition of lithogenic processes, the assessment of crystal formation speed, related recurrence rates, and guidance for selecting appropriate treatment modalities. CONCLUSIONS: Recognizing that no single classification system can comprehensively cover all aspects, the integration of all classification approaches is essential for tailoring urolithiasis patient-specific management.


Asunto(s)
Litotricia , Urolitiasis , Humanos , Urolitiasis/terapia , Diagnóstico por Imagen , Litotricia/métodos , Urólogos
9.
World J Urol ; 42(1): 500, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39217581

RESUMEN

PURPOSE: To evaluate the stone clearance rate and limitations of a novel integrated suction capability within a single-use flexible ureteroscope according to stone particle size. METHODS: Varying sized stone particles were created using a stone phantom (Begostone Plus, Bego ©, Lincoln, RI, USA). Particle size ranged as follows: 63-125 µm, 125-250 µm, 250-500 µm, 500 µm- 1 mm and 1-2 mm. These were mixed with Normal saline (0.9%) to mimic in vivo conditions. The suction enabled single-use flexible ureteroscope (Pusen, Zhuhai, China) was used to aspirate stone fragments in three trials. Firstly, aspiration of 5 g of each dust range was attempted. Secondly, a direct comparison of the integrated suction to a manual syringe technique was applied to 1 g of each size range. Finally, aspiration was applied to 5 g of a heterogenous 1:1:1:1:1 mixture. Endoscopic clearance rate (g/min) and number of blockages were recorded. Each challenge was repeated three times. RESULTS: The integrated suction cleared 100% of dust < 250 µm. Endoscopic clearance rates were significantly faster than manual aspiration (3.01 g/min versus 0.41 g/min) for dust between 125 and 250 µm (p = 0.008). Complete endoscopic clearance by 180 s (without encountering test limiting blockages) was unsuccessful for particles > 250 µm. Clearance rates were greatly limited by stone particle size heterogeneity above 250 µm, to 0.09 g/min. CONCLUSION: This technology works better in vitro than previously DISS evaluated methods when challenged by stone dust < 250 µm. However, this adaptation is significantly challenged in the presence of stone dust particles > 250 µm.


Asunto(s)
Ureteroscopios , Succión , Humanos , Diseño de Equipo , Tamaño de la Partícula , Técnicas In Vitro , Ureteroscopía/instrumentación , Ureteroscopía/métodos
10.
World J Urol ; 42(1): 487, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39158747

RESUMEN

OBJECTIVE: To evaluate the stone ablation rate and direct thermal damage from thulium fiber laser (TFL) lithotripsy using continuous (C) and burst (B) lasing techniques on an in vitro ureteral model. METHODS: The TFL Drive (Coloplast, Humlebaek, Denmark) was used in an in vitro saline-submerged ureteral model. Ten participants, including five junior and five experienced urologists, conducted the experimental setup with 7 different settings comparing two lasing techniques: steady-state lasing (0.5 J/10 Hz = 5W for 300 s and 0.5 J/20 Hz = 10W for 150 s) and burst, intermittent 5 s on/off lasing (0.5 J/20 Hz, 0.5 J/30 Hz, 0.5 J/60 Hz, 0.1 J/200 Hz, and 0.05 J/400 Hz) with a target cumulative energy of 1500 J using cubic 125 mm3 phantom BegoStonesTM. Ureteral damage was graded 1-3 based on the severity of burns and holes observed on the surface of the ureteral model. RESULTS: The were no significant differences in stone ablation mass neither between C and B lasing techniques, nor between expertise levels. At C lasing technique had only mild ureteral lesions with no significant differences between expertise levels (p: 0.97) or laser settings (p: 0.71). At B lasing technique, different types of thermal lesions were found with no expertise (p: 0.11) or setting (p: 0.83) differences. However, B laser setting had higher grade direct thermal lesions than C (p: 0.048). CONCLUSION: Regarding efficacy, C and B lasing techniques achieve comparable stone ablation rates. Safety-wise, B lasing mode showed higher grade of direct thermal lesions. These results should be further investigated to verify which of the lasing mode is the safest in vivo. Until then and unless proven otherwise, a C mode with low frequency should be recommended to avoid ureteral wall lesions.


Asunto(s)
Litotripsia por Láser , Tulio , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Humanos , Uréter/cirugía , Cálculos Ureterales/cirugía , Técnicas In Vitro , Láseres de Estado Sólido/uso terapéutico
11.
World J Urol ; 42(1): 57, 2024 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-38280001

RESUMEN

INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Litotripsia por Láser , Nefrolitiasis , Cálculos Urinarios , Humanos , Litotripsia por Láser/métodos , Tulio , Cistina , Cálculos Urinarios/cirugía , Láseres de Estado Sólido/uso terapéutico , Holmio
12.
World J Urol ; 42(1): 525, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39292299

RESUMEN

PURPOSE: Previous studies have demonstrated an association between video-gaming experience (VGE) and improved robotics skills. We aimed to evaluate the initial learning curve for the Ily® robotics system (Sterlab, Sophia Antipolis, France) when applied to flexible ureteroscopy (FU) among both medical students and urology surgeons. METHODS: There were two groups, surgeons and students. An initial questionnaire was completed detailing basic demographics and experience. In part one, both groups performed two simple timed tasks using an Ily® mounted single-use RAU. In part two, group 1 repeated both tasks using a hand-held FU. A subjective assessment of comfort, intuitiveness and a NASA Task Load Index were then completed. RESULTS: There was a total of 28 participants. Among medical students with VGE (n = 9, 64%)., average calyceal inspection time was 185 ± 80 s; 133 ± 42 s; 121 ± 71 s. For non-gamers (n = 5, 36%), average times were longer at 221 ± 97 s; 134 ± 35 s; 143 ± 68 s respectively. Average calyceal inspection time for videogaming surgeons (n = 8, 57%) was 126 ± 95 s; 98 ± 40 s; 107 ± 71 s, respectively. For non-gamers average inspection times were longer at 150 ± 73 s; 114 ± 82 s; 111 ± 47 s, respectively. None of these differences achieved statistical significance. Surgeons trial speeds were, however, significantly faster by hand-held compared to RAU: by 103, 81 and 82 s respectively (p < 0.05). CONCLUSION: These results show that ex- or current- video gamers do not have a significant advantage in time to perform FU. Any early advantage conferred to ex- or current- gamers may be rapidly overcome.


Asunto(s)
Curva de Aprendizaje , Procedimientos Quirúrgicos Robotizados , Estudiantes de Medicina , Ureteroscopía , Urología , Juegos de Video , Humanos , Ureteroscopía/instrumentación , Ureteroscopía/educación , Procedimientos Quirúrgicos Robotizados/educación , Masculino , Femenino , Urología/educación , Internado y Residencia/métodos , Adulto , Competencia Clínica
13.
World J Urol ; 42(1): 310, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38722553

RESUMEN

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Urólogos , Humanos , Urología , Procedimientos Quirúrgicos Urológicos
14.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520528

RESUMEN

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Asunto(s)
Iluminación , Ureteroscopios , Humanos , Diseño de Equipo , Urólogos , Equipos Desechables , Ureteroscopía
15.
World J Urol ; 42(1): 355, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38796790

RESUMEN

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Asunto(s)
Diseño de Equipo , Iluminación , Ureteroscopios , Ureteroscopía , Luz , Humanos , Solución Salina , Color
16.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613608

RESUMEN

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Holmio , Tulio , Ureteroscopía , Estudios Prospectivos , Cálculos Renales/cirugía , Rayos Láser
17.
World J Urol ; 42(1): 362, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38814457

RESUMEN

OBJECTIVE: To evaluate long-term surgical and functional outcomes of cystinuric patients exclusively treated with Ureteroscopy (URS). METHODS: Data from patients treated for cystine stones at a single academic center were retrospectively analyzed. The management protocol consisted of (i) treating symptomatic or > 7 mm stones, (ii) multi-staged URS for voluminous stones, (iii) referring patients to a dedicated nephrological clinic. The eGFR was calculated according to the MDRD formula. CKD category was assessed according to the NKF classification. Relevant CKD was defined as CKD category ≥ 3a. Descriptive statistics were used to analyze the cohort data. RESULTS: Data from 46 cystinuric patients treated with 332 URS were available. Median age at diagnosis and at first URS in our center were 18 and 32 years, respectively. Median follow-up was 101 months. Median number of URS and recurrences per patient were 6 and 2, respectively. The median interval between the first and the last available creatinine level was 64 months. Median first and last eGFR were 72 and 74 mL/min, respectively. Overall, 83% of patients had stable or improved renal function within the study period. Ureteral stricture occurred in 3 (6.5%) patients. CONCLUSIONS: Cystinuria requires intensive endoscopic management. Most patients treated with URS have stable or improved renal function within a long-term follow-up. CKD is a not neglectable event that potentially occurs at an early stage of life. Current findings should be considered for the surgical management of cystinuric patients.


Asunto(s)
Cistinuria , Centros de Atención Terciaria , Ureteroscopía , Humanos , Masculino , Estudios Retrospectivos , Adulto , Femenino , Adolescente , Cistinuria/complicaciones , Adulto Joven , Resultado del Tratamiento , Factores de Tiempo , Cálculos Renales/cirugía , Persona de Mediana Edad , Niño
18.
World J Urol ; 42(1): 294, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38704777

RESUMEN

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Asunto(s)
Ureteroscopios , Ureteroscopía , Humanos , Diseño de Equipo , Iluminación , Docilidad , Cálices Renales
19.
World J Urol ; 42(1): 298, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709327

RESUMEN

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Asunto(s)
Diseño de Equipo , Riñón , Iluminación , Ureteroscopios , Modelos Anatómicos , Humanos
20.
World J Urol ; 42(1): 453, 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39073430

RESUMEN

PURPOSE: To examine temporal-spatial distribution of heat generated upon laser activation in a bench model of renal calyx. To establish reference values for a safety distance between the laser fiber and healthy tissue during laser lithotripsy. METHODS: We developed an in-vitro experimental setup employing a glass pipette and laser activation under various intra-operative parameters, such as power and presence of irrigation. A thermal camera was used to monitor both temporal and spatial temperature changes during uninterrupted 60-second laser activation. We computed the thermal dose according to Sapareto and Dewey's formula at different distances from the laser fiber tip, in order to determine a safety distance. RESULTS: A positive correlation was observed between average power and the highest recorded temperature (Spearman's coefficient 0.94, p < 0.001). Irrigation was found to reduce the highest recorded temperature, with a maximum average reduction of 9.4 °C at 40 W (p = 0.002). A positive correlation existed between average power and safety distance values (Spearman's coefficient 0.86, p = 0.001). A thermal dose indicative of tissue damage was observed at 20 W without irrigation (safety distance 0.93±0.11 mm). While at 40 W, irrigation led to slight reduction in mean safety distance (4.47±0.85 vs. 5.22±0.09 mm, p = 0.08). CONCLUSIONS: Laser settings with an average power greater than 10 W deliver a thermal dose indicative of tissue damage, which increases with higher average power values. According to safety distance values from this study, a maximum of 10 W should be used in the ureter, and a maximum of 20 W should be used in kidney in presence of irrigation.


Asunto(s)
Litotripsia por Láser , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Humanos , Calor , Cálices Renales , Irrigación Terapéutica/métodos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda