Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Pediatr Diabetes ; 15(2): 91-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23944875

RESUMEN

BACKGROUND: Artificial pancreas (AP) systems have shown an improvement in glucose control and a reduced risk of nocturnal hypoglycemia under controlled conditions but remain to be evaluated under daily-life conditions. OBJECTIVE: To assess the feasibility, safety, and efficacy of the MD-Logic AP in controlling nocturnal glucose levels in the patient's home. METHODS: Two-arm study, each covering four consecutive nights comparing the MD-Logic AP ('closed-loop' arm) with sensor-augmented pump therapy ('control' arm). Fifteen patients (mean age 19 ± 10.4 yr, A1c 7.5 ± 0.5% or 58 ± 5.9 mmol/mol, diabetes duration 9.9 ± 8.2 yr) were randomly assigned either to 'Group A' (first 'closed-loop', then 'control' arm) or to 'Group B' (vice versa). Investigators were masked to treatment intervention. Primary endpoints were the time spent with glucose levels below 70 mg/dL and the percentage of nights in which the mean overnight glucose levels were within 90-140 mg/dL. Endpoint analyses were based on unmodified sensor glucose readings of the four study nights. RESULTS: Time of glucose levels spent below 70 mg/dL was significantly shorter on the closed-loop nights than on control nights, median and interquartile range 3.8 (0, 11.6) and 48.7 (0.6, 67.9) min, respectively; p = 0.0034. The percentage of individual nights in which mean overnight glucose level was within 90-140 mg/dL was 67 (33, 88), and 50 (25, 75), under closed-loop and control nights, respectively, with no statistical difference. Secondary endpoint analyses demonstrated significant improvements in hypoglycemia parameters. No serious adverse events were reported. CONCLUSION: This interim analysis demonstrates the feasibility, safety, and efficiency of the MD-Logic AP system in home use, and demonstrates an improvement over sensor-augmented pump therapy. (ClinicalTrials.gov identifier NCT01726829).


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Servicios de Atención de Salud a Domicilio , Páncreas Artificial , Adolescente , Adulto , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Automonitorización de la Glucosa Sanguínea/efectos adversos , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Niño , Ritmo Circadiano , Estudios Cruzados , Diabetes Mellitus Tipo 1/epidemiología , Estudios de Factibilidad , Femenino , Humanos , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Masculino , Páncreas Artificial/efectos adversos , Método Simple Ciego , Adulto Joven
2.
J Diabetes Sci Technol ; 9(2): 206-8, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25411060

RESUMEN

The objectives were to evaluate the current prevalence of lipoatrophy at insulin injection sites in young patients with type 1 diabetes. Standardized examination of insulin injection sites in all 678 patients with type 1 diabetes treated in 2013 in our outpatient clinic were conducted. In case of lipoatrophy photo documentation and standardized interview with parents and patients were performed. We identified a total of 16 patients (43.8% male) with lipoatrophy (overall prevalence 2.4%). The current mean age (±SD) of the affected patients was 14.4 ± 3.9 years, age and diabetes duration at onset of lipoatrophy were 11.5 ± 3.8 years and 5.4 ± 3.6 years, respectively. All patients were using analogs at the onset of lipoatrophy. In all, 14 of 16 patients (87.5%) were on insulin pump compared with 52% without lipoatrophy (P = .0018). The use of steel needle and Teflon catheter was equal between the pump patients. Concomitant autoimmune diseases were present in 37.5% of the patients (thyroiditis: n = 3, thyroiditis and celiac disease: n = 2, celiac disease: n = 1) compared with 15.0% in those without lipoatrophy (P = .0128). Lipoatrophy was present in young patients treated with modern insulins and pumps; however, the prevalence was relatively low as expected with the use of modern insulins. Our data may support the hypothesis that a constant mechanical element such as a subcutaneous catheter may trigger the development of lipoatrophy, particularly in those patients with more than 1 autoimmune disease.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/agonistas , Insulina/efectos adversos , Grasa Subcutánea/patología , Adolescente , Atrofia/inducido químicamente , Atrofia/epidemiología , Niño , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Incidencia , Inyecciones Subcutáneas , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Prevalencia
3.
Diabetes Technol Ther ; 16(6): 338-47, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24447074

RESUMEN

BACKGROUND: Predictive low glucose management (PLGM) may help prevent hypoglycemia by stopping insulin pump delivery based on predicted sensor glucose values. MATERIALS AND METHODS: Hypoglycemic challenges were simulated using the Food and Drug Administration-accepted glucose simulator with 100 virtual patients. PLGM was then tested with a system composed of a Paradigm(®) insulin pump (Medtronic, Northridge, CA), an Enlite™ glucose sensor (Medtronic), and a BlackBerry(®) (Waterloo, ON, Canada)-based controller. Subjects (n=22) on continuous subcutaneous insulin infusion (five females, 17 males; median [range] age, 15 [range, 14-20] years; median [range] diabetes duration, 7 [2-14] years; median [range] glycated hemoglobin, 8.0% [6.7-10.4%]) exercised until the PLGM system suspended insulin delivery or until the reference blood glucose value (HemoCue(®); HemoCue GmbH, Großostheim, Germany) reached the predictive suspension threshold setting. RESULTS: PLGM reduced hypoglycemia (<70 mg/dL) in silico by 26.7% compared with no insulin suspension, as opposed to a 5.3% reduction in hypoglycemia with use of low glucose suspend (LGS). The median duration of hypoglycemia (time spent <70 mg/dL) with PLGM was significantly less than with LGS (58 min vs. 101 min, respectively; P<0.001). In the clinical trial the hypoglycemic threshold during exercise was reached in 73% of the patients, and hypoglycemia was prevented in 80% of the successful experiments. The mean (±SD) sensor glucose at predictive suspension was 92±7 mg/dL, resulting in a postsuspension nadir (by HemoCue) of 77±22 mg/dL. The suspension lasted for 90±35 (range, 30-120) min, resulting in a sensor glucose level at insulin resumption of 97±19 mg/dL. CONCLUSIONS: In silico modeling and early feasibility data demonstrate that PLGM may further reduce the severity of hypoglycemia beyond that already established for algorithms that use a threshold-based suspension.


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 1/sangre , Ejercicio Físico , Hipoglucemia/inducido químicamente , Hipoglucemiantes/efectos adversos , Sistemas de Infusión de Insulina/efectos adversos , Insulina/efectos adversos , Adolescente , Técnicas Biosensibles , Simulación por Computador , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/fisiopatología , Estudios de Factibilidad , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Masculino , Monitoreo Ambulatorio , Adulto Joven
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda