Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Rep Pract Oncol Radiother ; 27(1): 1-9, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35402024

RESUMEN

Stereotactic radiotherapy (SRT ) is a multi-step procedure with each step requiring extreme accuracy. Physician-dependent accuracy includes appropriate disease staging, multi-disciplinary discussion with shared decision-making, choice of morphological and functional imaging methods to identify and delineate the tumor target and organs at risk, an image-guided patient set-up, active or passive management of intra-fraction movement, clinical and instrumental follow-up. Medical physicist-dependent accuracy includes use of advanced software for treatment planning and more advanced Quality Assurance procedures than required for conventional radiotherapy. Consequently, all the professionals require appropriate training in skills for high-quality SRT. Thanks to the technological advances, SRT has moved from a "frame-based" technique, i.e. the use of stereotactic coordinates which are identified by means of rigid localization frames, to the modern "frame-less" SRT which localizes the target volume directly, or by means of anatomical surrogates or fiducial markers that have previously been placed within or near the target. This review describes all the SRT steps in depth, from target simulation and delineation procedures to treatment delivery and image-guided radiation therapy. Target movement assessment and management are also described.

2.
Ann Vasc Surg ; 44: 420.e1-420.e5, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28495543

RESUMEN

Aortic dissection is a complex disease associated with high mortality and morbidity. Among the different possible clinical presentations, type A aortic dissection complicated at the onset by mesenteric malperfusion is characterized by poor outcome compared with patients not presenting such complication. We report the case of a patient with acute type A aortic dissection presenting with mesenteric malperfusion, in whom trans-pericardial color Doppler ultrasound (CDUS) examination was used to assess intraoperative and postoperative blood flow in the mesenteric artery. Trans-pericardial CDUS is demonstrated as a fast and simple diagnostic method with a good matching compared with contrast-enhanced computed tomography scan imaging, if correctly approached. We believe that this technique could be an important adjunctive tool for the intraoperative and perioperative management and decision-making in all patients with type A dissection presenting with mesenteric ischemia.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Arterias Mesentéricas/diagnóstico por imagen , Isquemia Mesentérica/diagnóstico por imagen , Circulación Esplácnica , Ultrasonografía Doppler en Color , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Aneurisma de la Aorta/complicaciones , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/fisiopatología , Aortografía/métodos , Angiografía por Tomografía Computarizada , Humanos , Masculino , Arterias Mesentéricas/fisiopatología , Isquemia Mesentérica/etiología , Isquemia Mesentérica/fisiopatología , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Resultado del Tratamiento
3.
Artículo en Inglés | MEDLINE | ID: mdl-36802253

RESUMEN

Elephant trunk and frozen elephant trunk are established procedures for the treatment of aortic arch pathologies, such as aneurysm or dissection. The aim of open surgery is to re-expand the true lumen, favouring correct organ perfusion and the thrombosis of the false lumen. Frozen elephant trunk, with its stented endovascular portion, is sometimes associated with a life-threatening complication: the stent graft-induced new entry. In the literature, many studies reported the incidence of such issue after thoracic endovascular prosthesis or frozen elephant trunk, but in our knowledge, there are no case studies about the occurrence of stent graft-induced new entry with the use of soft grafts. For this reason, we decided to report our experience, highlighting how the use of a Dacron graft can cause distal intimal tears. We decided to coin the term soft-graft-induced new entry to indicate the development of an intimal tear induced by the soft prosthesis in the arch and proximal descending aorta.

4.
Artículo en Inglés | MEDLINE | ID: mdl-37140560

RESUMEN

Endoleaks represent a main issue of endovascular approach of thoracic aorta diseases and their treatment continue to be challenging. According to some authors, type II endoleaks sustained by intercostal arteries should not be treated because of the technical difficulties. However, the persistence of a pressurized aneurysmal may confer an ongoing risk of enlargement and/or aortic rupture. We describe the successful treatment of type II endoleak in 2 patients with an intercostal artery's access. In both cases, the endoleak was discovered during follow-up and was treated with its direct coil embolization under local anaesthesia.

5.
J Vasc Surg Cases Innov Tech ; 9(2): 101093, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37427041

RESUMEN

An 80-year-old man with a chronic penetrating atherosclerotic ulcer was not a candidate for open surgical repair owing to the presence of diffuse vascular atherosclerosis and a deep ulcerative lesion originating at the level of the aortic arch concavity. No appropriate endovascular landing zone was present in arch zones 1 or 2. However, a totally endovascular branched arch repair involving transapical delivery of the three branches was successful.

6.
JTCVS Tech ; 6: 13-27, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34318130

RESUMEN

OBJECTIVE: To illustrate our experience and results in patients with diffuse aneurysmal disease treated with arch replacement using the Siena collared graft, a device designed in 2002 to improve the elephant trunk technique. Results of the first step surgical implant and the subsequent treatment strategies, with extensive use of endovascular techniques, are reported. METHODS: All aortic arch-replacement procedures using the Siena graft between February 2002 and January 2020 were retrospectively analyzed for early and late clinical outcomes. RESULTS: Of 146 patients (54 women, 36.9%) with a median age of 69.1 years (interquartile range 58.4-75.0 years), 55 (37.6%) had acute/chronic dissection with false lumen aneurysmal dilatation, 91 (62.3%) had degenerative aneurysms, 45 (30.8%) were redo operations, and 14 (9.5%) had connective tissue disease. First-stage outcomes: 10.9% 30-day mortality (n = 16); 5.4% stroke (n = 8, 6 disabling, 2 nondisabling; 3 fatal); and 0.6% paraplegia. Outcomes for 113 second-stage procedures (77.3%, n = 97 endovascular [66.4%], n = 16 surgical [10.9%]) were 5.3% and 8.8% 30-day and 180-day mortality; no stroke; 10.6% paraplegia. Median follow-up was 5.7 years (range: 0-18.02 years) median survival was 16.65 years (95% lower confidence limit, 10.06 years) with no significant difference between aneurysm and dissection patients. Freedom from further treatment was 87.0% (95% confidence interval, 79.9%-94.7%) at 5 years and 71.4% (95% confidence interval, 71.4%-84.7%) at 10 years; median time to reintervention was 2.59 years (interquartile range, 0.52-5.20 years) with no difference (P = .22) between dissection and aneurysm groups. CONCLUSIONS: Siena collared graft represents a reliable platform for the treatment of diffuse aneurysmal disease. This device offers the flexibility required in the treatment of extended aortic lesions and guarantees the choice of the most appropriate approach for treatment completion. In this context, the availability of hybrid grafts has not modified the role of this device in arch surgery.

7.
Chir Ital ; 61(3): 341-6, 2009.
Artículo en Italiano | MEDLINE | ID: mdl-19694237

RESUMEN

Radiation proctitis, is a relatively frequent complication resulting from the direct or collateral irradiation of the rectum in radiotherapy treatment for genito-urinary or anorectal malignancies. The main symptoms are diarrhoea, tenesmus, proctorrhagia, anal pain, mucorrhoea and faecal incontinence. The evolution of chronic radiation proctitis requires treatment for related anaemia, anal incontinence and micturition disorders. The approach and type of treatment depend on the severity of the symptoms and on the endoscopic aspect, in relation to the response to previous medical therapy performed. In our experience, endoscopic treatment is the best choice in the presence of ongoing bleeding and the possible development of severe anaemia. The surgical option is mandatory in patients at high risk of sepsis, requiring a faecal diversion constructed using the Hartmann technique. We report two cases, observed during the last two years, one treated with endoscopic bipolar coagulation and the other with a double urinary and faecal diversion.


Asunto(s)
Proctitis/etiología , Proctitis/terapia , Neoplasias de la Próstata/radioterapia , Anciano , Anciano de 80 o más Años , Antiinflamatorios no Esteroideos/uso terapéutico , Quimioterapia Combinada , Femenino , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/terapia , Glucocorticoides/uso terapéutico , Hemostasis Endoscópica/métodos , Humanos , Coagulación con Láser/métodos , Masculino , Radioterapia/efectos adversos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Sigmoidoscopía/métodos , Resultado del Tratamiento
9.
Interact Cardiovasc Thorac Surg ; 26(6): 1041-1042, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29351640

RESUMEN

We herein report an emergency technique of composite Bentall operation using a fast release valve. The technique was successfully performed in 2 emergency cases after failed supracoronary ascending aortic replacement in acute Type A aortic dissection. The speed and ease of execution are the main advantages of the procedure.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Urgencias Médicas , Disección Aórtica/complicaciones , Aneurisma de la Aorta Torácica/complicaciones , Insuficiencia de la Válvula Aórtica/complicaciones , Humanos
10.
J Vis Surg ; 4: 82, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29780728

RESUMEN

BACKGROUND: Residual false channel is common after repair of type A acute aortic dissection (TAAAD). Starting from our recent series of TAAAD patients we carried out a retrospective analysis, regarding the failure of primary exclusion at the time of the initial operation. We classified the location of the principal entry tears perfusing the residual false channel. The proposed technique represents our attempt to correct the mechanism of false channel perfusion during primary repair. We describe a new technique designed to address some limitations of standard hemiarch aortic replacement. Its goal are: (I) to reinforce the intimal layer at the arch level; (II) to eliminate inter-luminal communications at the arch level using suture lines around the arch vessels; (III) to provide an elephant trunk configuration for further interventions. METHODS: Between August 2016 and January 2018, 11 patients underwent emergency surgery using this technique; 7 were men; the median age was 74 years. All patients were treated using systemic circulatory arrest under moderate hypothermia (26 °C) and selective cerebral perfusion. All patients had supra-coronary repair; 1 patient had aortic valve replacement + CABG. In the first two patients a manual suture around supra-aortic trunks was used; the subsequent seven patients were treated with a mechanical suture bladeless device. CT scan follow up was performed in all survivors with controls before discharge 3 months and 1 year after operation. RESULTS: No patient died in the operating room and no neurologic deficit was observed in this initial experience. One patient died in POD 5th for low cardiac output syndrome. Median ICU stay was 3 days (IQR, 2-6 days). Hospital mean length of stay was 15.2±8 days. Median cardiopulmonary bypass time was 130 min (IQR, 110-141 min); median arrest time for re-layering was 17 min (IQR, 16-20 min); median total arrest was 36 min (IQR, 29-39 min). Distal aortic anastomosis was performed in zone 0 in 4 patients, zone 1, with innominate replacement, in 5 patients, in zone 2, with branches to innominate and left common carotid arteries, in 2 patients. Median follow up (closing date 06/01/2018) was 443 days (IQR, 262-557 days); no late deaths occurred. No dehiscence at the level of stapler or manual sutures was observed. Proximal 1/3 of the thoracic aorta false channel was obliterated in all cases but one; in 3 cases complete exclusion of the false channel was obtained after operation. In one case stent graft completion was required. CONCLUSIONS: This technique combines the advantages of arch replacement to the simplicity of anterior hemiarch repair. This study demonstrates the safety of the procedure and the possibility to induce aortic remodeling without complex arch replacement.

11.
G Ital Cardiol (Rome) ; 18(10): 738-741, 2017 Oct.
Artículo en Italiano | MEDLINE | ID: mdl-29105689

RESUMEN

Despite the technical advancements in transcatheter aortic valve implantation (TAVI), this procedure in patients with peripheral artery disease remains challenging and requires a patient-tailored management by the Heart Team. In-depth assessment of the patient's vascular anatomy is of utmost importance for the management of TAVI procedures with the aim to use the less invasive approach according to the specific patient characteristics. The trans-subclavian approach should be the preferred option in patients with femoral arterial disease undergoing TAVI; however, self-expandable valves have potential limitations, as in case of ascending aorta dilation and high implantation. We present an elegant solution to overcome this challenging situation with good short- and mid-term outcome. A balloon-expandable Edwards Sapien 3 prosthesis was implanted by right subclavian surgical access using a multistep approach. The imaging controls showed good positioning with trivial paravalvular leak. The right subclavian approach for balloon-expandable TAVI implantation is feasible and safe when performed by skilled operators and can be a valid treatment strategy when no other options are available.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Arteria Subclavia , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
12.
Eur J Cardiothorac Surg ; 28(6): 857-63, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16275113

RESUMEN

OBJECTIVE: Increased dimension of the aortic root and proximal aorta is considered a significant risk factor for catastrophic events that involve the ascending aorta. The objective of this study was to determine the possible correlation between pre-dissection aortic diameter and the occurrence of Stanford type A aortic dissection. METHODS: Samples of dissected ascending aortas were obtained from 220 patients at the time of their operation. Two groups were identified: patients with connective tissue disorders (Group 1, n=94) and those without (Group 2, n=126). Measurements of the true (intimal) lumen were conducted and extrapolated as reliable approximation of pre-dissection aortic diameter. The possible association of intimal diameter with anthropometric and demographic data was analyzed. RESULTS: Median aortic diameter was, respectively, 41.8 and 41.3mm for patients with and without connective tissue disorders (41.4mm for the entire cohort). Data analysis indicated that 57% of patients had aortic diameter above 40 mm, while patients with frank aneurysm accounted only for 10%; this proportion was higher in Group 1 compared to Group 2 (17.2% vs 4.7%). Poor or no correlation was demonstrated between aortic size and any of the anthropometric or demographic variables assayed. Significant subgroup differences were found among patients with a history of cigarette smoking, hypertension, diabetes, chronic renal insufficiency, and bicuspid aortic valve. CONCLUSION: Although aortic diameter remains a strong indication for preventive surgery in patients with inherited connective tissue disorders, acute aortic dissection occurs rarely in the setting of true ascending aortic aneurysms, and despite normal or near-normal aortic size in more than one-third of subjects. Dissection superimposing on small aortic diameters can be regarded as an expression of substantial functional tissue susceptibility to aortic catastrophic events.


Asunto(s)
Aneurisma de la Aorta/patología , Disección Aórtica/patología , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/cirugía , Antropometría , Aorta/patología , Aneurisma de la Aorta/cirugía , Síndrome de Ehlers-Danlos/patología , Femenino , Humanos , Hipertensión/patología , Fallo Renal Crónico/patología , Masculino , Síndrome de Marfan/patología , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/patología , Factores de Riesgo , Fumar/patología
13.
J Thorac Cardiovasc Surg ; 123(5): 901-10, 2002 May.
Artículo en Inglés | MEDLINE | ID: mdl-12019375

RESUMEN

BACKGROUND: In aortic operations performed through a left thoracotomy, which require total bypass and deep hypothermic circulatory arrest, femoral artery cannulation is commonly used for arterial perfusion. This route limits the time of safe circulatory arrest and is associated with the risks of retrograde embolization or, in the case of aortic dissection, malperfusion of the vital organs. To overcome these problems, we have used cannulation of the extrathoracic left common carotid artery to ensure a central a route of arterial perfusion in these operations. The preliminary results are presented. METHODS: Between December 1999 and April 2001, we used left common carotid artery cannulation in 26 operations on the thoracic aorta performed through a posterolateral thoracotomy with an open technique during deep hypothermic circulatory arrest. Institutional review board approval and informed consent were obtained. The indications included perforating atherosclerotic ulcer (n = 5), chronic aortic aneurysm (n = 9), acute type B aortic dissection (n = 3), and chronic dissection of the thoracic aorta (n = 9). Transcranial Doppler ultrasonographic monitoring of both the right and left middle cerebral arteries was used to assess the adequacy of cerebral bihemispheric perfusion and to determine the differences in blood flow velocities throughout the procedure. RESULTS: Left common carotid artery cannulation was successful in all patients. All patients awoke from the operation, and none had cerebrovascular accidents. None died in the hospital, and complications related to carotid artery cannulation were not observed. None of the patients experienced postoperative paraplegia. In all patients transcranial Doppler monitoring indicated the absence of cerebral embolic phenomena throughout the entire procedure. Significant differences in middle cerebral artery flow velocities were observed at different phases of the procedures and between the right and left middle cerebral arteries during carotid cannulation and during selective cerebral perfusion. Nevertheless, the maximal drop of right middle cerebral artery blood velocity during selective perfusion through the left common carotid artery was within 50% of the left middle cerebral artery velocity, indicating adequate bihemispheric perfusion. CONCLUSIONS: In patients undergoing aortic operations through a left thoracotomy, extrathoracic left common carotid artery cannulation was a safe and effective means of providing proximal arterial inflow during cardiopulmonary bypass, which can be used to selectively perfuse the brain, as well as to prevent embolic phenomena in the arch vessels.


Asunto(s)
Aorta Torácica/cirugía , Isquemia Encefálica/prevención & control , Puente Cardiopulmonar/métodos , Arteria Carótida Común , Cateterismo/métodos , Adulto , Anciano , Aorta Torácica/fisiopatología , Puente Cardiopulmonar/mortalidad , Circulación Cerebrovascular/fisiología , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Periodo Posoperatorio , Estudios Retrospectivos , Toracotomía/métodos , Resultado del Tratamiento
16.
Cardiovasc Intervent Radiol ; 35(5): 1195-200, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22484703

RESUMEN

PURPOSE: Abdominal aortic aneurysm (AAA) accompanied by common iliac artery (CIA) aneurysms requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent-graft limb(s), a potential site of endoleak. The "sandwich technique" is a procedure to increase EVAR feasibility in the setting of adverse or challenging CIA anatomy. Its main advantages include no restrictions in terms of CIA diameter or length or internal iliac artery (IIA) diameter, no need to wait for a specific stent-graft. Our purpose is to describe our single-center experience and one year follow-up results of this new procedure. MATERIALS AND METHODS: From April 2009 to June 2010, the sandwich technique was performed in our institution in 7 patients treated for AAA and unilateral CIA aneurysms (n. 5) or bilateral CIA aneurysms (n. 2). Inclusion criteria were the presence of unilateral or bilateral CIA aneurysm (independently from its diameter), IIA artery measuring up to 9 mm in its maximum diameter, not dilatation of IIA and EIA. RESULTS: The mean follow-up length was 15 months (range: 14-20 months). All stent-implanted iliac branches remained patent on 1 year follow-up and IIA flow was preserved. None of the patients had symptoms of pelvic ischemia. CT scan follow-up showed aneurysm shrinkage in five patients, without any sign of endoleaks in all cases. CONCLUSIONS: In selected cases, the "sandwich technique" showed good outcomes confirming to be a safe and easy to perform way to overcome anatomical constraints and expanding the limits of EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Aneurisma Ilíaco/cirugía , Stents , Anciano , Anciano de 80 o más Años , Angiografía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Endofuga/prevención & control , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Grado de Desobstrucción Vascular
17.
Cardiovasc Intervent Radiol ; 35(1): 176-9, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21901580

RESUMEN

An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Ablación por Catéter/instrumentación , Stents , Disección Aórtica/diagnóstico por imagen , Angiografía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Fluoroscopía , Humanos , Persona de Mediana Edad , Ondas de Radio , Tomografía Computarizada por Rayos X
18.
Ann Thorac Surg ; 90(6): e88-90, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21095293

RESUMEN

We report the successful treatment of a life-threatening thoracoabdominal aneurysm in a young patient affected by type I Loeys-Dietz syndrome. To overcome anatomic and surgical difficulties, we used an original strategy and a specially designed surgical tool. The clinical and technical aspects of this approach are presented.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Síndrome de Loeys-Dietz/complicaciones , Adulto , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda