Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Kyobu Geka ; 76(11): 962-965, 2023 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-38056957

RESUMEN

A woman in 70s was diagnosed with lung cancer, and a right atrial mass was discovered incidentally during preoperative examination by contrast-enhanced computed tomography (CT). Transesophageal echocardiography revealed a 20-mm, stemmed, spherical mass with low internal echogenicity and partially high echogenicity extending from the junction of the inferior vena cava to the posterior wall of the right atrium. Patent foramen ovale( PFO) was also confirmed. To avoid embolization and obtain diagnosis, the patient was referred for right atrial tumor resection. Cardiopulmonary bypass was established; the right atrial tumor was removed while the patient was in cardiac arrest. The tumor membrane was thin and easily ruptured, revealing jelly-like blood content and calcified mass. The patient recovered well after surgery and was discharged on day 15. According to the pathological examination, the tumor was a blood cyst. This is an extremely rare case of a blood cyst with PFO.


Asunto(s)
Quistes , Foramen Oval Permeable , Neoplasias Pulmonares , Femenino , Humanos , Quistes/complicaciones , Quistes/diagnóstico por imagen , Quistes/cirugía , Ecocardiografía Transesofágica , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Anciano
2.
Kyobu Geka ; 72(12): 1019-1022, 2019 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-31701915

RESUMEN

A 67-year-old woman encountered a traffic accident and had chest computed tomography(CT) examination. It revealed a 24 mm Kommerell's diverticulum associated with a right-sided aortic arch and a 15 mm saccular aneurysm of an aberrant left subclavian artery. We performed intra-aneurysmal coil embolization for the left subclavian artery aneurysm after a balloon occlusion test of the left subclavian artery. The postoperative course was uneventful.


Asunto(s)
Aneurisma , Divertículo , Anciano , Aneurisma/complicaciones , Aorta Torácica , Anomalías Cardiovasculares , Divertículo/complicaciones , Femenino , Humanos , Arteria Subclavia/anomalías
3.
Surg Endosc ; 30(1): 339-45, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25894445

RESUMEN

OBJECTIVE: Identification of intersegmental planes is essential for successful anatomic pulmonary segmentectomy. We have previously reported a new fluorescence technique using a PDD endoscope system™ and vitamin B2 for identification of intersegmental planes in ex vivo experiments. In the present study, we investigated and evolved this technique to perform ideal anatomic segmentectomy in a clinical setting using living pig models. METHODS: Cranial segmentectomy in the cranial lobe of the right lung was performed in six pigs using our fluorescence technique. The fluorescent cranial segmentectomy was as follows. After identification of the cranial segmental bronchus, vitamin B2 solution as a fluorescent substance was injected via bronchoscopy. The fluorescent segment was observed using a PDD endoscope system, and the identified intersegmental plane was cut using electric cautery. The operative data collected were the rates of accurate identification of the pulmonary segment and perioperative complications. The duration and light intensity of fluorescence of the target segment were recorded to provide an objective measurement of success. RESULTS: In all procedures, it was possible to identify the target segment by its clear yellow-green fluorescence. The rate of accurate identification of the pulmonary segment was 100%. The fluorescence continued for more than 1 h with adequate light intensity. No perioperative complications were encountered. No unexpected injuries of the major segmental bronchi or vessels occurred. Hemorrhage and air leakage from the transected intersegmental plane were negligible. CONCLUSIONS: Our new fluorescence technique in a clinical setting involving a PDD endoscope system™ vitamin B2 enabled accurate and safe anatomic pulmonary segmentectomy, with enough strong and long fluorescence in living pig lungs.


Asunto(s)
Endoscopios , Fluorescencia , Fármacos Fotosensibilizantes , Neumonectomía/métodos , Riboflavina , Animales , Cauterización , Modelos Animales , Porcinos
4.
J Cardiothorac Surg ; 19(1): 381, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926884

RESUMEN

BACKGROUND: Following an acute myocardial infarction (AMI), surgery for left ventricular free wall rupture (LVFWR) and ventricular septal rupture (VSR) has a high in-hospital mortality rate, which has not improved significantly over time. Unloading the LV is critical to preventing excessive stress on the repair site and avoiding problems such as bleeding, leaks, patch dehiscence, and recurrence of LVFWR and VSR because the tissue is so fragile. We present two cases of patients who used Impella 5.5 for LV unloading following emergency surgery for AMI mechanical complications. CASE PRESENTATION: A 76-year-old male STEMI patient underwent fibrinolysis of the distal right coronary artery. Three days later, he passed out and went into shock. Echocardiography revealed a cardiac tamponade. We found an oozing-type LVFWR on the posterolateral wall and treated it with a non-suture technique using TachoSil. Before the patient was taken off CPB, Impella 5.5 was inserted into the LV via a 10 mm synthetic graft connected to the right axillary artery. We kept the flow rate above 4.0 to 4.5 L/min until POD 3 to reduce LV wall tension while minimizing pulsatility. On POD 6, we weaned the patient from Impella 5.5. A postoperative cardiac CT scan showed no contrast leakage from the LV. However, a cerebral hemorrhage on POD 4 during heparin administration complicated his hospitalization. Case 2: A diagnosis of cardiogenic shock caused by STEMI occurred in an 84-year-old male patient, who underwent PCI of the LAD with IABP support. Three days after PCI, echocardiography revealed VSR, and the patient underwent emergency VSR repair with two separate patches and BioGlue applied to the suture line between them. Before weaning from CPB, we implanted Impella 5.5 in the LV and added venoarterial extracorporeal membrane oxygenation (VA-ECMO) support for right heart failure. The postoperative echocardiography revealed no residual shunt. CONCLUSIONS: Patients undergoing emergency surgery for mechanical complications of AMI may find Impella 5.5 to be an effective tool for LV unloading. The use of VA-ECMO in conjunction with Impella may be an effective strategy for managing VSR associated with concurrent right-sided heart failure.


Asunto(s)
Corazón Auxiliar , Humanos , Masculino , Anciano , Infarto del Miocardio/cirugía , Infarto del Miocardio/complicaciones , Ventrículos Cardíacos/fisiopatología , Rotura Cardíaca Posinfarto/cirugía , Rotura Septal Ventricular/cirugía , Rotura Septal Ventricular/etiología , Ecocardiografía , Complicaciones Posoperatorias
5.
J Thorac Cardiovasc Surg ; 164(5): 1400-1409.e3, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-33341270

RESUMEN

OBJECTIVE: The present study aimed to evaluate the outcomes of total aortic arch replacement with proximalization of distal anastomosis using the frozen elephant trunk technique with the J Graft FROZENIX (Japan Lifeline, Tokyo, Japan) and Gelweave Lupiae (Vascutek Terumo Inc, Scotland, United Kingdom) graft (distal anastomosis performed in zones 1 and 2) in patients with acute Stanford type A acute aortic dissection. METHODS: A total of 50 patients underwent total aortic arch replacement using the frozen elephant trunk technique, deploying the J Graft FROZENIX into zone 1 or 2 (zone 1: n = 17, zone 2: n = 33) in combination with the Gelweave Lupiae graft for acute Stanford type A acute aortic dissection. Patient characteristics, intraoperative data, and early and midterm outcomes were analyzed. RESULTS: The overall in-hospital mortality rate was 4% (2 patients). The in-hospital mortality rate in patients with visceral malperfusion was 11% (1/9). There were no patients with paraplegia and stent graft-induced new entry. Resection or closure of the most proximal entry tear was achieved in 100% of 42 patients who had postoperative computed tomography. The overall survival was 87.9%, 84.1%, and 84.1% at 1, 2, and 3 years, respectively. However, 1 patient required endovascular extension for the dilatation of the descending thoracic aorta 4 months after the initial surgery. CONCLUSIONS: Total aortic arch replacement with the frozen elephant trunk technique (zone 1-2) and Gelweave Lupiae graft was safe and effective in simplifying surgery for acute Stanford type A acute aortic dissection.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Stents , Resultado del Tratamiento
6.
Gen Thorac Cardiovasc Surg ; 69(4): 744-747, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33125594

RESUMEN

While there are many reports on partial aortic root remodeling, it is rarely performed for chronic aortic dissection of the coronary artery. This report presents a case of a 69-year-old man incidentally diagnosed with aortic dissection during routine checkup. He had a history of percutaneous coronary intervention from the left main trunk to the left anterior descending artery and left circumflex artery. Computed tomography revealed a chronic type A aortic dissection with an aneurysmal aortic root. The false lumen of the Valsalva sinus originated from the left anterior descending artery and expanded largely to the non-coronary Valsalva sinus. We performed partial aortic root remodeling, resecting the dissected non-coronary Valsalva sinus. The postoperative course was uneventful. Partial aortic root remodeling was effective, but its use might be controversial for chronic aortic dissection without resection of the primary entry of the left anterior descending artery. Moreover, close follow-up is required.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Intervención Coronaria Percutánea , Seno Aórtico , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Corazón , Humanos , Masculino , Seno Aórtico/diagnóstico por imagen , Seno Aórtico/cirugía
7.
J Cardiothorac Surg ; 13(1): 132, 2018 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-30587212

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is the standard treatment for high-risk patients with aortic stenosis (AS); however, alternative treatments for patients who are ineligible for TAVI are controversial. CASE PRESENTATION: 56 year-old female who required 6 γ dobutamine support due to congestive heart failure was diagnosed as severe aortic stenosis with bicuspid valve. Echocardiography revealed left ventricular ejection fraction (LVEF) was 15%. The patient was relatively young for TAVI, and TAVI was not licensed for patient presenting with a bicuspid aortic valve in places other than the limited institutions in Japan. On pump beating aortic valve replacement (AVR) was performed with selective antegrade coronary artery blood perfusion. She resumed a completely normal lifestyle by 3 weeks after the operation. CONCLUSIONS: A relatively young patient for TAVI who was diagnosed as aortic stenosis with severely reduced ejection fraction and bicuspid valve is reported. Beating AVR with a continuously selective antegrade-perfusion was achieved safely with good clinical results in a patient with severely reduced left ventricular (LV) function. Beating AVR can be considered as a potential alternative for patients who are ineligible for conventional surgical aortic valve replacement (SAVR) and TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Disfunción Ventricular Izquierda/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología
10.
Ann Thorac Surg ; 103(5): e431-e433, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28431718

RESUMEN

A 38-year-old man with polyarteritis nodosa presented with exertional chest pain. Coronary angiography revealed 3-vessel coronary artery disease. We performed 2-vessel coronary artery bypass grafting with the saphenous vein because the left internal thoracic artery was in poor condition. Histological examination of the left internal thoracic artery showed a strong effect of polyarteritis nodosa.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/etiología , Arterias Mamarias/patología , Poliarteritis Nudosa/complicaciones , Adulto , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Masculino , Vena Safena/trasplante
11.
Eur J Cardiothorac Surg ; 44(1): 146-53, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23242985

RESUMEN

OBJECTIVES: We developed a new classification system for branch perfusion patterns in acute aortic dissection and used it to retrospectively evaluate the perfusion status of whole aortic branches and to examine the effects of central aortic repair. METHODS: Thirty-four consecutive patients with acute type A aortic dissection underwent emergent surgery at our institution between August 2008 and December 2011. A retrospective review of pre- and postoperative computed tomographic angiography was performed. Branch perfusion patterns were categorized into three classes: Class I, dissection involving but not extending into the branch; Class II, dissection extending into the branch and Class III, dissection causing ostial avulsion. RESULTS: In cervical branches (total 169 branches), 70 branches (41%) presented with Class I patterns, 58 (34%) with Class II and none with Class III. In abdominal branches (total 135 branches), 76 branches (56%) presented with Class I patterns, 12 (9%) with Class II and 18 (13%) with Class III. In common iliac arteries (total 68 arteries), 14 arteries (21%) presented with Class I patterns, 24 (35%) with Class II and none with Class III. After repair, among 21 high-risk cervical branches, 14 branches (67%) showed improvement, 3 (14%) preserved distal perfusion supplied through the patent branch false lumen and 4 (19%) showed no improvement in high-risk perfusion pattern or worsened. Among 22 high-risk abdominal branches, 18 branches (82%) showed improvement, 3 (14%) preserved distal perfusion supplied through the patent branch or aortic false lumen and 1 (5%) showed no improvement in high-risk perfusion pattern. CONCLUSIONS: To overcome malperfusion syndromes associated with acute aortic dissection, recognition of diverse branch perfusion patterns through a universal classification system is imperative.


Asunto(s)
Aorta , Aneurisma de la Aorta , Disección Aórtica , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/clasificación , Disección Aórtica/fisiopatología , Disección Aórtica/cirugía , Angiografía/métodos , Aorta/fisiopatología , Aorta/cirugía , Aneurisma de la Aorta/clasificación , Aneurisma de la Aorta/fisiopatología , Aneurisma de la Aorta/cirugía , Femenino , Humanos , Arteria Ilíaca/fisiopatología , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Flujo Sanguíneo Regional/fisiología , Reperfusión , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos , Procedimientos Quirúrgicos Vasculares
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda