1.
Lasers Surg Med ; 48(4): 385-91, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26941063

RESUMEN

BACKGROUND AND OBJECTIVE: As a result of wound healing the original tissue is replaced by dysfunctional scar tissue. Reduced tissue damage during surgical procedures beneficially affects the size of the resulting scar and overall healing time. Thus the choice of a particular surgical instrument can have a significant influence on the postoperative wound healing. To overcome these problems of wound healing we applied a novel picosecond infrared laser (PIRL) system to surgical incisions. Previous studies indicated that negligible thermal, acoustic, or ionization stress effects to the surrounding tissue results in a superior wound healing. STUDY DESIGN/MATERIALS AND METHODS: Using the PIRL system as a surgical scalpel, we performed a prospective wound healing study on rat skin and assessed its final impact on scar formation compared to the electrosurgical device and cold steel. As for the incisions, 6 full-thickness, 1-cm long-linear skin wounds were created on the dorsum of four rats using the PIRL, an electrosurgical device, and a conventional surgical scalpel, respectively. Rats were euthanized after 21 days of wound healing. The thickness of the subepithelial fibrosis, the depth and the transverse section of the total scar area of each wound were analyzed histologically. RESULTS: After 21 days of wound healing the incisions made by PIRL showed minor scar tissue formation as compared to the electrosurgical device and the scalpel. Highly significant differences (P < 0.001) were noted by comparing the electrosurgical device with PIRL and scalpel. The transverse section of the scar area also showed significant differences (P = 0.043) when comparing PIRL (mean: 141.46 mm2; 95% CI: 105.8-189.0 mm2) with scalpel incisions (mean: 206.82 mm2; 95% CI: 154.8-276.32 mm2). The subepithelial width of the scars that resulted from using the scalpel were 1.3 times larger than those obtained by using the PIRL (95% CI: 1.0-1.6) though the difference was not significant (P < 0.083). CONCLUSIONS: The hypothesis that PIRL results in minimal scar formation with improved cosmetic outcomes was positively verified. In particular the resection of skin tumors or pathological scars, such as hypertrophic scars or keloids, are promising future fields of PIRL application.


Asunto(s)
Cicatriz/prevención & control , Procedimientos Quirúrgicos Dermatologicos/instrumentación , Rayos Infrarrojos/uso terapéutico , Terapia por Láser/instrumentación , Rayos Láser , Complicaciones Posoperatorias/prevención & control , Cicatrización de Heridas , Animales , Cicatriz/etiología , Electrocirugia/instrumentación , Femenino , Ratas , Resultado del Tratamiento
2.
Z Med Phys ; 23(1): 21-32, 2013 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-22917569

RESUMEN

For LDR-brachytherapy, a limited number of implant geometries and materials are available. To avoid wound healing related hyper-proliferation (stenosis, keloids) a novel radioactive foil system was developed based on beta emitting (32)P, which can be easily integrated in existing implants such as urethral catheters or bile duct stents. As substrate material for these foils PEEK (polyetherethercetone) was chosen because of its radiation hardness during neutron activation of (32)P. The activity was determined by liquid scintillation counting and gamma spectroscopy, dose distributions were measured with scintillation detectors and radiochromic films. The correlation between activity and dose was checked by Monte-Carlo-simulations (Geant4). Prototypes of the (32)P-implants have shown in wash-out tests the required tightness for sealed radioactive sources. In animal tests on urethra and bile duct, the uncomplicated and save application of (32)P-foils mounted on standard implants has been demonstrated, which is almost unchanged due to the simple radiation protection with plexiglass. This concept of radioactive implants with integrated (32)P-foils could extend essentially the application possibilities of LDR-brachytherapy.


Asunto(s)
Braquiterapia/instrumentación , Braquiterapia/métodos , Gastroenterología/instrumentación , Radioisótopos de Fósforo/uso terapéutico , Urología/instrumentación , Constricción Patológica/radioterapia , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Prótesis e Implantes , Radiofármacos/uso terapéutico