Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Data Brief ; 39: 107590, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34877374

RESUMEN

We performed in-situ tensile tests on two carbon fibre/epoxy composites with continuous scanning using synchrotron computed tomography (CT). Both composites were cross-ply laminates, and two specimens were tested for each composite. The voxel size was sufficiently small to recognize individual fibres and fibre breaks. For each test, 16-19 volumes were reconstructed, cropped down to the 0° plies and analysed to track fibre break and cluster development. This dataset provides the last CT volume before failure for each of the four specimens as well as the individual fibre break locations in all reconstructed volumes. These data are then plotted against predictions from six state-of-the-art strength models. The target is that these data become a benchmark for the development of new models, inspiring researchers to set up refined experiments and develop improved models.

2.
BMC Res Notes ; 11(1): 649, 2018 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-30185209

RESUMEN

OBJECTIVE: The purpose of this study was the construction of a new semi-automated experimental setup for the evaluation of the stiffness of ankle foot orthoses (AFOs) around an axis aligned to the anatomical ankle joint during the second rocker of the gait. The setup, developed in close collaboration with the orthopedic device company V!GO NV (Wetteren, Belgium), allows measurement of plantarflexion and dorsiflexion in the sagittal plane for a maximal range of motion of 50° (- 25° plantarflexion up to 25° dorsiflexion) in a non-destructive way. RESULTS: The mechanical properties of four 3D printed AFOs are investigated, based on the ranges of motion derived from the gait assessment of the patients when they walked with their AFO. The reliability of the stiffness measures was studied by the evaluation of the test-retest repeatability and the intra-tester and inter-tester variability. These studies revealed that the ankle stiffness can be measured with high reliability (ICC = 0.94-1.00). The obtained outcomes indicate that the experimental setup could be applied to measure the ankle stiffness of any topology of AFOs and, in the future, help finding the correlation with the information coming from the gait assessment of the patients.


Asunto(s)
Tobillo , Ortesis del Pié , Rango del Movimiento Articular , Articulación del Tobillo , Bélgica , Fenómenos Biomecánicos , Diseño de Equipo , Femenino , Pie , Marcha , Humanos , Masculino , Aparatos Ortopédicos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda