Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Environ Manage ; 167: 167-74, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26686069

RESUMEN

Excessive phosphate in wastewater should be removed to control eutrophication of water bodies. The potential of employing amorphous zirconium (Zr) hydroxide to remove phosphate from synthetic wastewater was studied in batch adsorption experiments and in a submerged membrane filtration adsorption hybrid (MFAH) reactor. The adsorption data satisfactorily fitted to Langmuir, pseudo-first order and pseudo-second order models. Langmuir adsorption maxima at 22 °C and pHs of 4.0, 7.1, and 10.0 were 30.40, 18.50, and 19.60 mg P/g, respectively. At pH 7.1 and temperatures of 40 °C and 60 °C, they were 43.80 and 54.60 mg P/g, respectively. The thermodynamic parameters, ΔG° and ΔS° were negative and ΔH° was positive. FTIR, zeta potential and competitive phosphate, sulphate and nitrate adsorption data showed that the mechanism of phosphate adsorption was inner-sphere complexation. In the submerged MFAH reactor experiment, when Zr hydroxide was added at doses of 1-5 g/L once only at the start of the experiment, the removal of phosphate from 3 L of wastewater containing 10 mg P/L declined after 5 h of operation. However, when Zr hydroxide was repeatedly added at 5 g/L dose every 24 h, satisfactory removal of phosphate was maintained for 3 days.


Asunto(s)
Hidróxidos/química , Fosfatos/química , Eliminación de Residuos Líquidos/instrumentación , Aguas Residuales/química , Circonio/química , Adsorción , Concentración de Iones de Hidrógeno , Cinética , Nitratos/química , Fosfatos/aislamiento & purificación , Espectroscopía Infrarroja por Transformada de Fourier , Sulfatos/química , Temperatura , Termodinámica , Eliminación de Residuos Líquidos/métodos
2.
Water Sci Technol ; 69(12): 2431-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24960004

RESUMEN

While high quality water reuse based on dual membrane filtration (membrane filtration or ultrafiltration, followed by reverse osmosis) is expected to be progressively applied, treatment and sustainable management of the produced reverse osmosis concentrate (ROC) are still important issues. Forward osmosis (FO) is a promising technology for maximising water recovery and further dewatering ROC so that zero liquid discharge is produced. Elevated concentrations of organic and inorganic compounds may act as potential foulants of the concentrate desalting system, in that they consist of, for example, FO and a subsequent crystallizer. The present study investigated conditions under which the FO system can serve as concentration phase with the focus on its fouling propensity using model foulants and real ROC. Bulk organics from ROC consisted mainly of humic acids (HA) and building blocks since wastewater-derived biopolymers were retained by membrane filtration or ultrafiltration. Organic fouling of the FO system by ROC-derived bulk organics was low. HA was only adsorbed moderately at about 7% of the initial concentration, causing a minor flux decline of about 2-4%. However, scaling was a major impediment to this process if not properly controlled, for instance by pH adjustment or softening.


Asunto(s)
Incrustaciones Biológicas , Ósmosis , Reciclaje , Purificación del Agua/métodos , Filtración/instrumentación , Filtración/métodos , Concentración de Iones de Hidrógeno
3.
Sci Rep ; 14(1): 8239, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589571

RESUMEN

The DSSAT CANEGRO model was calibrated and verified using field experimental data from five Tamil Nadu Agroclimatic Zones (1981-2022). The genetic coefficients of the sugarcane cultivar (CO-86032) were calculated. R2 obtained between measured and simulated stalk fresh mass was 0.9 with the nRMSE (0.01) and RMSE (1.6) and R2 between measured and simulated sucrose mass was 0.9 with the nRMSE (0.16) and RMSE (1.2). For yield R2 obtained between measured and simulated was 0.9 with the nRMSE (0.01) and RMSE (1.6). As a result, the CANEGRO model may be used to mimic the phenology and yield features of the sugarcane cultivar in Tamil Nadu's Agro Climatic Zones. Temperature increases in Agro Climatic Zones resulted in varying yield reductions, with 2 °C increases causing a 3% loss, 3 °C increases 5%, and 4 °C increases 9%. The Water Requirement rose throughout all of the ACZ due to the high temperature, but to differing degrees. A 2 °C increase often results in an average 4% increase in the WR. 3 °C rise in temperature increased WR to 9% and WR rose by 13% when the temperature was raised by 4 °C.

4.
Water Environ Res ; 84(2): 115-9, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22515060

RESUMEN

Membrane fouling is linked to reversible or irreversible accumulation of macromolecules and solids on membrane surfaces and to the irreversible adsorption inside pores. If reversible accumulation can be controlled by filtering in subcritical conditions, then adsorption could also be minimized by reducing the soluble organic matter [extracellular polymeric substances, soluble microbial products (SMP)]. This research shows how the choice of operating parameters related to biological reaction (solid retention time and the organic loading rate) can influence the process rate and the by-product (SMP) production. It also illustrates how suspension characteristics and membrane aeration can influence membrane fouling control according to the hollow fiber configuration and to the different scales of observation. The investigations were based on the definition of different fouling level and fine-tuning of a model to better understand the effects of operating parameters on membrane bioreactor filtration.


Asunto(s)
Reactores Biológicos , Membranas Artificiales , Eliminación de Residuos Líquidos/instrumentación , Filtración/instrumentación , Filtración/métodos , Contaminantes Químicos del Agua
5.
Water Sci Technol ; 65(2): 332-9, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22233913

RESUMEN

The use of secondary wastewater effluent (SWWE) is an essential strategy for making better use of limited water resources. However, a wide range of organic compounds eventually renders them unsuitable for recycling. In water treatment processes, biologically activated carbon (BAC) is adopted after physicochemical treatment. However, the effectiveness of such combination for SWWE remains poorly understood. This study investigates the effectiveness of various combinations: BAC/enhanced coagulation (EC) or EC/BAC, especially in terms of dissolved organic carbon (DOC) removal. The results showed that distinct advantage could be obtained by adopting BAC/EC combination rather than EC/BAC, as microbes in BAC not only remove non-coagulable compounds but also synergize the removal efficiency by releasing some coagulable humic substances.


Asunto(s)
Carbono/química , Carbono/metabolismo , Eliminación de Residuos Líquidos/métodos , Adsorción , Carbono/análisis , Cloruros/química , Compuestos Férricos/química , Floculación , Sustancias Húmicas/análisis , Concentración de Iones de Hidrógeno , Oxígeno/análisis , Aguas del Alcantarillado
6.
Water Sci Technol ; 63(10): 2097-105, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21977626

RESUMEN

This paper presents the results of the long term biofilter experiments conducted with raw stormwater collected from a canal at Carlton, in Sydney. Anthracite and granular activated carbon (GAC) were used as a single filter media in biofilter columns. Media heights of 75 and 40 cm were used. The filter columns were operated at filtration velocities of 0.12 and 0.25 m/h. The removal efficiency for turbidity and DOC for the GAC filter media were found to be 75% and almost 100% respectively. The removal efficiency for the anthracite filter was much lower. Molecular weight distribution analysis showed an almost similar trend to the DOC removal. Compared with anthracite filter media, the GAC biofilter removed a much larger range of organic compounds present in the stormwater. The GAC biofilter removes organic matter earlier as compared to anthracite. Based on a limited sample of stormwater, the removal efficiency for phosphorus was upto 74% and that of nitrogen was up to 30%. In general GAC filter shows higher heavy metal removal efficiency than anthracite. The removal of zinc, iron, lead and nickel were good. However the concentration of heavy metal in the raw surface water sample was low.


Asunto(s)
Carbón Orgánico/química , Filtración , Purificación del Agua/métodos , Concentración de Iones de Hidrógeno , Metales Pesados/aislamiento & purificación , Peso Molecular , Compuestos Orgánicos/aislamiento & purificación , Reciclaje
7.
Water Sci Technol ; 64(8): 1642-51, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22335107

RESUMEN

Wastewater is no longer considered a waste product and water reuse needs to play a stronger part in securing urban water supply. Although treatment technologies for water reclamation have significantly improved the question that deserves further analysis is, how selection of a particular wastewater treatment technology relates to performance and sustainability? The proposed assessment model integrates; (i) technology, characterised by selected quantity and quality performance parameters; (ii) productivity, efficiency and reliability criteria; (iii) quantitative performance indicators; (iv) development of evaluation model. The challenges related to hierarchy and selections of performance indicators have been resolved through the case study analysis. The goal of this study is to validate a new assessment methodology in relation to performance of the microfiltration (MF) technology, a key element of the treatment process. Specific performance data and measurements were obtained at specific Control and Data Acquisition Points (CP) to satisfy the input-output inventory in relation to water resources, products, material flows, energy requirements, chemicals use, etc. Performance assessment process contains analysis and necessary linking across important parametric functions leading to reliable outcomes and results.


Asunto(s)
Reciclaje/métodos , Agua/química , Algoritmos , Ciudades , Conservación de los Recursos Energéticos , Filtración/métodos , Aguas del Alcantarillado , Eliminación de Residuos Líquidos/métodos , Purificación del Agua
8.
Water Sci Technol ; 62(12): 2854-61, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21123915

RESUMEN

A Water Sensitive City is now commonly acknowledged best practice for designing the cities of the future. In Australia, the National Water Initiative has allocated high priority towards offering insight into successful water sensitive urban development projects, to facilitate capacity building within the industry. This paper shares innovative water sensitive projects implemented at Kogarah City Council, in Sydney. Four key projects are discussed, demonstrating how stormwater, rainwater and wastewater can be incorporated into decentralised water systems to offer sustainable water management of the future. The case studies included in the paper highlight Kogarah's journey towards the Soft Path for Water Management.


Asunto(s)
Lluvia , Administración de Residuos/métodos , Movimientos del Agua , Australia , Reciclaje , Eliminación de Residuos Líquidos , Humedales
9.
Water Sci Technol ; 62(12): 2937-43, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21123925

RESUMEN

In this study the hybrid filtration process (combining fibre filter with deep bed dual media filtration) was investigated as pre-treatment to stormwater. This process was investigated in-terms of reduction in turbidity, dissolved organic carbon (DOC), colour, headloss development across the filters, suspended solids removal, organic matter removal, nutrients and heavy matter (such as iron, copper, lead, zinc) removal efficiency. A comparison was made between the hybrid filter with single media (sand) deep bed filter and fibre filter. It was found that the hybrid filtration system successfully removed turbidity (98%), colour (99%), suspended solids (99%), and DOC (55%). The removal efficiency of heavy metal was relatively low as the concentration of heavy metals present in stormwater was low. The removal efficiency of nitrate, nitrite and phosphorous (as orthophosphate) was 27, 35 and 72% respectively. Hybrid filtration processes showed a better reduction of Modified Fouling Index (MFI) value (from 15.500 s/l(2) to 9 s/l(2)) compared with single media sand, anthracite and fibre filter which were 35 s/l(2), 13 s/l(2)and 14 s/l(2) respectively when operated at FeCl(3) dose of 15 mg/l.


Asunto(s)
Filtración/métodos , Lluvia , Eliminación de Residuos Líquidos/métodos , Carbón Mineral , Dióxido de Silicio , Purificación del Agua
10.
Water Sci Technol ; 61(7): 1733-8, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20371931

RESUMEN

This study forms a part of the physical study of the membrane bioreactor in presence of buoyancy media. Kaolin clay suspension with buoyancy media (anthracite) was used as a suspension and the particle layer development on membrane surface with evolution of time was studied. Presence of buoyancy media reduced the pressure development by almost two folds compared to in absence of the media. The particles deposition on membrane surface was size selective. The mean particle diameter (0.45 mum) deposited on the membrane surface remained almost similar in presence of the media after 7 hrs run where as in its absence the mean diameter finer particles deposition occurred at the beginning followed by coarser particles.


Asunto(s)
Reactores Biológicos , Filtración/instrumentación , Filtración/métodos , Membranas Artificiales , Eliminación de Residuos Líquidos/instrumentación , Eliminación de Residuos Líquidos/métodos , Caolín/química , Tamaño de la Partícula , Purificación del Agua/instrumentación , Purificación del Agua/métodos
11.
Water Sci Technol ; 61(2): 421-8, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20107269

RESUMEN

Although most Australians receive their domestic supply from reticulated mains or town water, there are vast areas with very low population densities and few reticulated supplies. In many of these areas rainwater collected in tanks is the primary source of drinking water. Heavy metals have recently become a concern as their concentration in rain water tanks was found to exceed recommended levels suitable for human consumption. Rainwater storage tanks also accumulate contaminants and sediments that settle to the bottom. Although not widely acknowledged, small amounts of contaminants such as lead found in rain water (used as drinking water) may have a cumulative and poisonous effect on human health over a life time. This is true for certain factors that underlie many of the chronic illnesses that are becoming increasingly common in contemporary society. The paper reports on a study which is part of a project that aims to develop a cost effective in-line filtration system to improve water quality in rainwater tanks. To enable this, the characteristics of rainwater need to be known. One component of this characterization is to observe the effects of the first flush on a rainwater tank. Samples of the roof runoff collected from an urban residential roof located in the Sydney Metropolitan Area in the initial first few millimetres of rain were analysed. The results show that bypassing the first 2 mm of rainfall gives water with most water quality parameters compliant with the Australian Drinking Water Guidelines (ADWG) standards. The parameters that did not comply were lead and turbidity, which required bypassing approximately the first 5 mm of rainfall to meet ADWG standards. Molecular weight distribution (MWD) analysis showed that the concentration of rainwater organic matter (RWOM) decreased with increasing amount of roof runoff.


Asunto(s)
Lluvia , Abastecimiento de Agua/normas , Agua/química , Australia , Población Rural , Contaminantes del Agua
12.
Water Sci Technol ; 61(2): 429-39, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20107270

RESUMEN

Rainwater collected from ten domestic roofs in Sydney and from one in Wollongong, a town south of Sydney, Australia was analysed to determine the water quality and to compare against the Australian Drinking Water Guidelines (ADWG) to determine its suitability as a potable water supply. The pollutants analysed were 13 heavy metals, 8 salts & minerals, pH, ammonia, orthophosphate, conductivity, water hardness, turbidity, total suspended solids, Total dissolved salts & Bicarbonate. The results indicate that the rainwater tested complied to most of the parameters specified in the ADWG. Molecular weight distribution of organic matter from one of the domestic rainwater tanks was analysed in terms of the effects of aging and roof contact. Molecular weight distribution of organic matter in rainwater showed prominent peaks at 37,500 daltons may be due to biopolymers, 850 Da to humic substances, 500 Da to building blocks, 220 Da to low MW acids, and less than 220 Da to amphiphilics. The findings also indicate that the first flush volumes that by-passed the tank can have a significant influence on the water quality in the rainwater tank.


Asunto(s)
Lluvia , Abastecimiento de Agua/normas , Agua/química , Concentración de Iones de Hidrógeno , Nueva Gales del Sur , Factores de Tiempo , Contaminantes Químicos del Agua/análisis
13.
Water Sci Technol ; 61(2): 513-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20107279

RESUMEN

In this study, short-term experiments were conducted with different configurations of membrane hybrid systems to treat biological treated sewage effluent containing refractory organic pollutants: (i) submerged hollow fiber microfiltration (SMF) alone; (ii) spiral flocculator (SF)-SMF without settling; (iii) SF-PAC-SMF without settling and (iv) SMF with magnetic ion exchange resin MIEX pretreatment. The results indicated that the pre-flocculation of SF could improve the mitigation of membrane fouling significantly even when the system was operated at a high membrane filtration rate. The transmembrane pressure (TMP) of SF-PAC-SMF only increased marginally (0.8 kPa over 8 hours). SF-SMF without the addition of powdered activated carbon (PAC) also took a relatively long duration for the TMP to increase. The TMP only increased by 2.5 kPa over 8 hours. The SF-PAC-MF system resulted in a high dissolved organic carbon (DOC) removal of more than 96%. When used as pre-treatment to submerged membranes, the fluidized bed MIEX contactor could remove a significant amount of organic matter in wastewater. This pre-treatment helped to reduce the membrane fouling and kept the TMP low during the membrane operation.


Asunto(s)
Conservación de los Recursos Naturales/métodos , Filtración/instrumentación , Membranas Artificiales , Purificación del Agua/métodos , Agua/química , Adsorción , Reactores Biológicos , Filtración/métodos , Intercambio Iónico , Factores de Tiempo , Purificación del Agua/instrumentación
15.
Water Sci Technol ; 55(4): 211-8, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17425088

RESUMEN

Innovative Water Sensitive Urban Design (WSUD) systems are being investigated at three locations to the north and south of Sydney, Australia. These systems contain porous concrete pipes that are designed so that stormwater exfiltrates through the permeable walls of the pipes into the surrounding substrate media material. The porous pipes and media material treat the passing stormwater. The primary aim of the overall project is to develop a model to describe the treatment effectiveness of confined WSUD systems. This paper focuses on the system located at the Weathertex Industrial Site, Heatherbrae. Due to wood processing operations that occur at this site, it is recognised that the surface runoff will carry a heavy organics loading. Granulated Activated Carbon (GAC) is recognised for its ability to reduce the concentration of dissolved organics present in both wastewater and stormwater. GAC was therefore chosen as a filtration medium to be investigated at this site. To maximise the effectiveness of the GAC, extensive laboratory batch studies were undertaken prior to the field system being constructed to determine the optimum GAC/sand ratio. The purpose of the experimental work was to assess the dissolved organic removal potential through sorption of various concentrations of GAC. The aim of this paper is to describe these laboratory experiments and discuss how they related to the field system. Through these experiments it was determined that a sand/GAC ratio of 25:1 was ideal for the media material at the Heatherbrae site.


Asunto(s)
Planificación de Ciudades/métodos , Suelo , Purificación del Agua/métodos , Ciudades , Conservación de los Recursos Naturales/métodos , Filtración , Lluvia , Movimientos del Agua , Contaminación del Agua/análisis , Contaminación del Agua/prevención & control
16.
Water Sci Technol ; 53(4-5): 179-84, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16722068

RESUMEN

The application of automation and supervisory control and data acquisition (SCADA) systems to municipal water and wastewater treatment plants is rapidly increasing. However, the application of these systems is less frequent in the research and development phases of emerging treatment technologies used in these industries. This study involved the implementation of automation and a SCADA system to the submerged membrane adsorption hybrid system for use in a semi-pilot scale research project. An incremental approach was used in the development of the automation and SCADA systems, leading to the development of two new control systems. The first system developed involved closed loop control of the backwash initiation, based upon a pressure increase, leading to productivity improvements as the backwash is only activated when required, not at a fixed time. This system resulted in a 40% reduction in the number of backwashes required and also enabled optimised operations under unsteady concentrations of wastewater. The second system developed involved closed loop control of the backwash duration, whereby the backwash was terminated when the pressure reached a steady state. This system resulted in a reduction of the duration of the backwash of up to 25% and enabled optimised operations as the foulant build-up within the reactor increased.


Asunto(s)
Eliminación de Residuos Líquidos/instrumentación , Eliminación de Residuos Líquidos/métodos , Adsorción , Automatización , Reactores Biológicos , Carbono/química , Sistemas en Línea , Programas Informáticos
17.
Water Res ; 39(12): 2549-58, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15979683

RESUMEN

An experimental investigation was made to study the effects of chemical coupling of flocculation and adsorption with photocatalysis in treating persistent organic pollutants in wastewater. The photocatalysis alone showed initial reverse reaction when titanium oxide (TiO(2)) was used in catalysis. The effect of the pretreatment of adsorption with powdered activated carbon (PAC) on photocatalysis was studied. The results showed that PAC adsorption followed by photocatalysis was not effective in alleviating reverse reaction. On the other hand, when PAC and TiO(2) were added simultaneously, the reverse reaction was eliminated. Further, the organic removal was also improved by simultaneous PAC and TiO(2) additions. When flocculation with ferric chloride (FeCl(3)) was used as pretreatment, the organic removal efficiency was superior. The initial reverse reaction was also eliminated/minimized. However, inadequate doses of FeCl(3) (less than 30 mgl(-1)) resulted in initial reverse reaction and inferior DOC removal.


Asunto(s)
Compuestos Orgánicos/aislamiento & purificación , Fotoquímica , Eliminación de Residuos Líquidos/métodos , Purificación del Agua/métodos , Adsorción , Carbono/química , Carbono/aislamiento & purificación , Catálisis , Cloruros , Compuestos Férricos/química , Floculación , Factores de Tiempo , Titanio/química
18.
Water Res ; 39(1): 147-53, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15607174

RESUMEN

In this study, ferric chloride (FeCl(3)) flocculation was used as a pretreatment to ultrafiltration (UF) in treating synthetic wastewater containing synthetic organic matter (SOM). The effect of flocculant dose was studied in terms of organic removal and membrane flux decline. The UF with optimum dose of FeCl(3) (68 mg L(-1)) did not experience any flux decline during the whole operation of 6 h. The preflocculation with a smaller dose of 20 mg L(-1) of FeCl(3) led to a severe flux decline in the UF (more than 65% in 6 h). To understand the phenomenon of the flux decline of UF, the MW ranges of SOM removed by different doses of FeCl(3) and by the post treatment of UF were studied. Flocculation with at least 50 mg L(-1) of FeCl(3) dose was found to be necessary to avoid any significant flux decline and to obtain superior DOC removal.


Asunto(s)
Compuestos Férricos/química , Eliminación de Residuos Líquidos/métodos , Carbono/química , Cloruros , Floculación , Peso Molecular , Ultrafiltración
19.
Water Sci Technol ; 51(6-7): 277-84, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16003987

RESUMEN

In this study, different pretreatment methods such as ferric chloride (FeCl3) flocculation and powdered activated carbon (PAC) adsorption were evaluated in terms of their capability in removing effluent organic matter (EfOM) and the characteristics of the foulants on the NF membranes. A detailed experiment was conducted with two NF membranes (NTR 729HF with MWCO 700 daltons and LF 10 with MWCO 200 daltons). With pretreatment, the concentration of organic matter on the membranes decreased to 5.671 x 10(-3) (NTR 729HF) and 4.940 x 10(-3) (LF 10) mg EfOM/cm2 of membrane from 6.372 x 10(-3) (NTR 729HF) and 4.979 x 10(-3) (LF 10) mg EfOM/cm2 of membrane. The MW of the solute fraction of biologically treated sewage effluent (BTSE) ranged from 250 daltons to about 3573 (the most important being 250-520 daltons). The weight-averaged MW values of the foulants on the NTR 729HF membrane reduced from 304 daltons without pre-treatment to 208 daltons with pretreatment. In the case of EfOM, the small molecules (MW 300 to 500 daltons) are mainly responsible for the membrane fouling. Thus, the MW distribution of organic matter in the effluent and in the foulant can be used as a representative tool to evaluate the efficiency of pretreatment and NF and in the selection of their operating conditions.


Asunto(s)
Membranas Artificiales , Eliminación de Residuos Líquidos/métodos , Purificación del Agua/métodos , Adsorción , Carbono/química , Cloruros , Falla de Equipo , Compuestos Férricos/química , Floculación , Peso Molecular , Compuestos Orgánicos/aislamiento & purificación , Ósmosis , Tamaño de la Partícula , Factores de Tiempo , Ultrafiltración
20.
Water Sci Technol ; 51(10): 93-100, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16104410

RESUMEN

Floating plastic media followed by hollow fiber microfiltration membrane was applied for surface water treatment. The performance of the system in terms of particle and microorganisms was investigated. The floating filter was examined at different filtration rates of 5, 10 and 15 m3/m2 x h. Treated water was then fed into a microfiltration unit where different filtration rates were examined at 0.6, 1.0 and 1.4 m3/m2 x d. It was found that polyaluminum chloride was the best coagulant for the removal of particle, algae and coliform bacteria. Average turbidity in treated water from the floating plastic media filter was 3.3, 12.2 and 15.5 NTU for raw water of 80 NTU and 12.9, 11.7 and 31.2 NTU for raw water of 160 NTU after 6 hours at the filtration rates of 5, 10 and 15 m3/m2 x h, respectively. The microfiltration unit could further reduce the turbidity to 0.2-0.5 NTU with low transmembrane pressure development of 0.3-3.7 kPa. Microfiltration membrane could retain most of algae and coliform bacteria remaining in the effluent from the pretreatment unit. It was found that at higher turbidity, algae and coliform bacteria removal efficiencies were achieved at lower filtration rate of the system of 5 m3/m2 x h whereas a higher filtration rate of 15 m3/m2 x h yielded better coliphage removal.


Asunto(s)
Plásticos , Eliminación de Residuos Líquidos/métodos , Purificación del Agua/métodos , Enterobacteriaceae/aislamiento & purificación , Eucariontes/aislamiento & purificación , Filtración , Ensayo de Materiales , Membranas Artificiales , Tamaño de la Partícula , Microbiología del Agua
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda