Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(29): e2203199119, 2022 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-35858350

RESUMEN

Lithium-ion battery (LIB) is a broadly adopted technology for energy storage. With increasing demands to improve the rate capability, cyclability, energy density, safety, and cost efficiency, it is crucial to establish an in-depth understanding of the detailed structural evolution and cell-degradation mechanisms during battery operation. Here, we present a laboratory-based high-resolution and high-throughput X-ray micro-computed laminography approach, which is capable of in situ visualizing of an industry-relevant lithium-ion (Li-ion) pouch cell with superior detection fidelity, resolution, and reliability. This technique enables imaging of the pouch cell at a spatial resolution of 0.5 µm in a laboratory system and permits the identification of submicron features within cathode and anode electrodes. We also demonstrate direct visualization of the lithium plating in the imaged pouch cell, which is an important phenomenon relevant to battery fast charging and low-temperature cycling. Our development presents an avenue toward a thorough understanding of the correlation among multiscale structures, chemomechanical degradation, and electrochemical behavior of industry-scale battery pouch cells.

2.
Proc Natl Acad Sci U S A ; 118(25)2021 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-34140413

RESUMEN

Multicontrast X-ray imaging with high resolution and sensitivity using Talbot-Lau interferometry (TLI) offers unique imaging capabilities that are important to a wide range of applications, including the study of morphological features with different physical properties in biological specimens. The conventional X-ray TLI approach relies on an absorption grating to create an array of micrometer-sized X-ray sources, posing numerous limitations, including technical challenges associated with grating fabrication for high-energy operations. We overcome these limitations by developing a TLI system with a microarray anode-structured target (MAAST) source. The MAAST features an array of precisely controlled microstructured metal inserts embedded in a diamond substrate. Using this TLI system, tomography of a Drum fish tooth with high resolution and tri-contrast (absorption, phase, and scattering) reveals useful complementary structural information that is inaccessible otherwise. The results highlight the exceptional capability of high-resolution multicontrast X-ray tomography empowered by the MAAST-based TLI method in biomedical applications.


Asunto(s)
Tomografía Computarizada por Rayos X , Animales , Análisis de Datos , Electrodos , Peces/anatomía & histología , Imagenología Tridimensional , Interferometría , Iluminación , Diente/anatomía & histología , Diente/diagnóstico por imagen
3.
Proc Natl Acad Sci U S A ; 112(8): 2314-9, 2015 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-25675478

RESUMEN

Trace metals play important roles in normal and in disease-causing biological functions. X-ray fluorescence microscopy reveals trace elements with no dependence on binding affinities (unlike with visible light fluorophores) and with improved sensitivity relative to electron probes. However, X-ray fluorescence is not very sensitive for showing the light elements that comprise the majority of cellular material. Here we show that X-ray ptychography can be combined with fluorescence to image both cellular structure and trace element distribution in frozen-hydrated cells at cryogenic temperatures, with high structural and chemical fidelity. Ptychographic reconstruction algorithms deliver phase and absorption contrast images at a resolution beyond that of the illuminating lens or beam size. Using 5.2-keV X-rays, we have obtained sub-30-nm resolution structural images and ∼90-nm-resolution fluorescence images of several elements in frozen-hydrated green algae. This combined approach offers a way to study the role of trace elements in their structural context.


Asunto(s)
Chlorophyta/anatomía & histología , Congelación , Imagenología Tridimensional/métodos , Difracción de Rayos X/métodos , Chlorophyta/citología , Microscopía Fluorescente
4.
Angew Chem Int Ed Engl ; 57(37): 11957-11962, 2018 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-30070756

RESUMEN

A state-of-the-art operando spectroscopic technique is applied to Co/TiO2 catalysts, which account for nearly half of the world's transportation fuels produced by Fischer-Tropsch catalysis. This allows determination of, at a spatial resolution of approximately 50 nm, the interdependence of formed hydrocarbon species in the inorganic catalyst. Observed trends show intra- and interparticular heterogeneities previously believed not to occur in particles under 200 µm. These heterogeneities are strongly dependent on changes in H2 /CO ratio, but also on changes thereby induced on the Co and Ti valence states. We have captured the genesis of an active FTS particle over its propagation to steady-state operation, in which microgradients lead to the gradual saturation of the Co/TiO2 catalyst surface with long chain hydrocarbons (i.e., organic film formation).

5.
J Microsc ; 265(1): 81-93, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27580164

RESUMEN

Trace metals play important roles in biological function, and x-ray fluorescence microscopy (XFM) provides a way to quantitatively image their distribution within cells. The faithfulness of these measurements is dependent on proper sample preparation. Using mouse embryonic fibroblast NIH/3T3 cells as an example, we compare various approaches to the preparation of adherent mammalian cells for XFM imaging under ambient temperature. Direct side-by-side comparison shows that plunge-freezing-based cryoimmobilization provides more faithful preservation than conventional chemical fixation for most biologically important elements including P, S, Cl, K, Fe, Cu, Zn and possibly Ca in adherent mammalian cells. Although cells rinsed with fresh media had a great deal of extracellular background signal for Cl and Ca, this approach maintained cells at the best possible physiological status before rapid freezing and it does not interfere with XFM analysis of other elements. If chemical fixation has to be chosen, the combination of 3% paraformaldehyde and 1.5 % glutaraldehyde preserves S, Fe, Cu and Zn better than either fixative alone. When chemically fixed cells were subjected to a variety of dehydration processes, air drying was proved to be more suitable than other drying methods such as graded ethanol dehydration and freeze drying. This first detailed comparison for x-ray fluorescence microscopy shows how detailed quantitative conclusions can be affected by the choice of cell preparation method.


Asunto(s)
Fibroblastos/química , Fibroblastos/citología , Microscopía Fluorescente/métodos , Espectrometría por Rayos X/métodos , Fijación del Tejido/métodos , Oligoelementos/análisis , Animales , Ratones , Células 3T3 NIH
6.
J Synchrotron Radiat ; 23(Pt 5): 1210-5, 2016 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-27577777

RESUMEN

Recent progress in the development of dichroic Bragg coherent diffractive imaging, a new technique for simultaneous three-dimensional imaging of strain and magnetization at the nanoscale, is reported. This progress includes the installation of a diamond X-ray phase retarder at beamline 34-ID-C of the Advanced Photon Source. The performance of the phase retarder for tuning X-ray polarization is demonstrated with temperature-dependent X-ray magnetic circular dichroism measurements on a gadolinium foil in transmission and on a Gd5Si2Ge2 crystal in diffraction geometry with a partially coherent, focused X-ray beam. Feasibility tests for dichroic Bragg coherent diffractive imaging are presented. These tests include (1) using conventional Bragg coherent diffractive imaging to determine whether the phase retarder introduces aberrations using a nonmagnetic gold nanocrystal as a control sample, and (2) collecting coherent diffraction patterns of a magnetic Gd5Si2Ge2 nanocrystal with left- and right-circularly polarized X-rays. Future applications of dichroic Bragg coherent diffractive imaging for the correlation of strain and lattice defects with magnetic ordering and inhomogeneities are considered.

7.
J Synchrotron Radiat ; 23(Pt 5): 1151-7, 2016 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-27577770

RESUMEN

Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

8.
Opt Express ; 23(5): 5438-51, 2015 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-25836777

RESUMEN

Ptychography is a coherent diffraction imaging (CDI) method for extended objects in which diffraction patterns are acquired sequentially from overlapping coherent illumination spots. The object's complex transmission function can be reconstructed from those diffraction patterns at a spatial resolution limited only by the scattering strength of the object and the detector geometry. Most experiments to date have positioned the illumination spots on the sample using a move-settle-measure sequence in which the move and settle steps can take longer to complete than the measure step. We describe here the use of a continuous "fly-scan" mode for ptychographic data collection in which the sample is moved continuously, so that the experiment resembles one of integrating the diffraction patterns from multiple probe positions. This allows one to use multiple probe mode reconstruction methods to obtain an image of the object and also of the illumination function. We show in simulations, and in x-ray imaging experiments, some of the characteristics of fly-scan ptychography, including a factor of 25 reduction in the data acquisition time. This approach will become increasingly important as brighter x-ray sources are developed, such as diffraction limited storage rings.


Asunto(s)
Imagenología Tridimensional , Movimiento (Física) , Rayos X , Animales , Simulación por Computador
9.
Phys Chem Chem Phys ; 17(16): 10551-5, 2015 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-25804979

RESUMEN

Lithium ion batteries are the dominant form of energy storage in mobile devices, increasingly employed in transportation, and likely candidates for renewable energy storage and integration into the electrical grid. To fulfil their powerful potential, electrodes with increased capacity, faster charge rates, and longer cycle life must be developed. Understanding the mechanics and chemistry of individual nanoparticles under in situ conditions is a crucial step to improving performance and mitigating damage. Here we reveal three-dimensional strain evolution within a single nanoparticle of a promising high voltage cathode material, LiNi0.5Mn1.5O4, under in situ conditions. The particle becomes disconnected during the second charging cycle. This is attributed to the formation of a cathode electrolyte interphase layer with slow ionic conduction. The three-dimensional strain pattern within the particle is independent of cell voltage after disconnection, indicating that the particle is unable to redistribute lithium within its volume or to its neighbours. Understanding the disconnection process at the single particle level and the equilibrium or non-equilibrium state of nanoparticles is essential to improving performance of current and future electrochemical energy storage systems.

10.
J Synchrotron Radiat ; 21(Pt 6): 1224-30, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25343788

RESUMEN

Data Exchange is a simple data model designed to interface, or `exchange', data among different instruments, and to enable sharing of data analysis tools. Data Exchange focuses on technique rather than instrument descriptions, and on provenance tracking of analysis steps and results. In this paper the successful application of the Data Exchange model to a variety of X-ray techniques, including tomography, fluorescence spectroscopy, fluorescence tomography and photon correlation spectroscopy, is described.

11.
Opt Express ; 22(26): 32082-97, 2014 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-25607174

RESUMEN

Ptychography is an imaging method whereby a coherent beam is scanned across an object, and an image is obtained by iterative phasing of the set of diffraction patterns. It is able to be used to image extended objects at a resolution limited by scattering strength of the object and detector geometry, rather than at an optics-imposed limit. As technical advances allow larger fields to be imaged, computational challenges arise for reconstructing the correspondingly larger data volumes, yet at the same time there is also a need to deliver reconstructed images immediately so that one can evaluate the next steps to take in an experiment. Here we present a parallel method for real-time ptychographic phase retrieval. It uses a hybrid parallel strategy to divide the computation between multiple graphics processing units (GPUs) and then employs novel techniques to merge sub-datasets into a single complex phase and amplitude image. Results are shown on a simulated specimen and a real dataset from an X-ray experiment conducted at a synchrotron light source.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Microscopía/métodos , Refractometría/métodos , Procesamiento de Señales Asistido por Computador , Aumento de la Imagen/instrumentación , Interpretación de Imagen Asistida por Computador/instrumentación , Microscopía/instrumentación , Refractometría/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Opt Express ; 20(21): 24038-48, 2012 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-23188371

RESUMEN

A scanning coherent diffraction imaging method was used to reconstruct the X-ray wavefronts produced by a Fresnel zone plate (FZP) and by Kirkpatrick-Baez (KB) focusing mirrors. The ptychographical measurement was conducted repeatedly by placing a lithographed test sample at different defocused planes. The wavefronts, recovered by phase-retrieval at well-separated planes, show good consistency with numerical propagation results, which provides a self-verification. The validity of the obtained FZP wavefront was further confirmed with theoretical predictions.


Asunto(s)
Lentes , Refractometría/instrumentación , Rayos X , Diseño de Equipo , Análisis de Falla de Equipo
13.
Opt Lett ; 36(11): 1954-6, 2011 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-21633413

RESUMEN

As the resolution in coherent diffractive imaging improves, interexposure and intraexposure sample dynamics, such as motion, degrade the quality of the reconstructed image. Selecting data sets that include only exposures where tolerably little motion has occurred is an inefficient use of time and flux, especially when detector readout time is significant. We provide an experimental demonstration of an approach in which all images of a data set exhibiting sample motion are combined to improve the quality of a reconstruction. This approach is applicable to more general sample dynamics (including sample damage) that occur during measurement.

14.
Phys Rev Lett ; 106(1): 013903, 2011 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-21231742

RESUMEN

This Letter demonstrates that coherent diffractive imaging (CDI), in combination with phase-diversity methods, provides reliable and artefact free high-resolution images. Here, using x rays, experimental results show a threefold improvement in the available image contrast. Furthermore, in conditions requiring low imaging dose, it is demonstrated that phase-diverse CDI provides a factor of 2 improvement in comparison to previous CDI techniques.

15.
Phys Med Biol ; 65(3): 035008, 2020 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-31874460

RESUMEN

Talbot-Lau interferometry (TLI) provides additional contrast modes for x-ray imaging that are complementary to conventional absorption radiography. TLI is particularly interesting because it is one of the few practical methods for realizing phase contrast with x-rays that is compatible with large-spot high power x-ray sources. A novel micro array anode structured target (MAAST) x-ray source offers several advantages for TLI over the conventional combination of an extended x-ray source coupled with an absorption grating including higher flux and larger field of view, and these advantages become more pronounced for x-ray energies in excess of 30 keV. A Monte Carlo simulation was performed to determine the optimal parameters for a MAAST source for use with TLI. It was found that the both spatial distribution of x-ray production and the number of x-ray produced in the MAAST have a strong dependence on the incidence angle of the electron beam.


Asunto(s)
Electrodos , Procesamiento de Imagen Asistido por Computador/métodos , Interferometría/instrumentación , Interferometría/métodos , Radiografía/métodos , Humanos , Modelos Teóricos , Método de Montecarlo , Rayos X
16.
Sci Rep ; 10(1): 9919, 2020 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-32555373

RESUMEN

Our future bioeconomy depends on increased utilization of renewable lignocellulosic biomass. Controlling the diffusion of chemicals, such as inorganic ions, within secondary plant cell walls is central to many biomass applications. However, insufficient understanding of intra-cell-wall diffusion within secondary plant cell walls is hindering the advancement of many lignocellulosic biomass applications. In this work, X-ray fluorescence microscopy was used to measure diffusion constants of K+, Cu2+, and Cl- diffusing through loblolly pine (Pinus taeda) cell wall layers under 70%, 75%, or 80% relative humidity (RH). Results revealed that diffusion constants increased with RH, the larger Cu2+ diffused more slowly than the K+, and the Cl- diffusion constant was the same as that for the counter cation, indicating cations and anions diffused together to maintain charge neutrality. Comparison with electrical conductivity measurements showed that conductivity is being controlled by ion mobility over these RH. The results further support that intra-cell-wall diffusion of inorganic ions is a Fickian diffusion process occurring through rubbery amorphous polysaccharides, which contradicts previous assertions that intra-cell-wall diffusion is an aqueous process occurring through water pathways. Researchers can now utilize polymer science approaches to engineer the molecular architecture of lignocellulosic biomass to optimize properties for specific end uses.

17.
Phys Med Biol ; 64(14): 145011, 2019 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-31163408

RESUMEN

Talbot-Lau grating interferometer (TLGI) has great advantages in x-ray imaging contrasts, especially for low-Z materials, over conventional absorption contrast. A microstructured array anode target (MAAT) source offers significantly higher imaging throughput than the combination of an extended x-ray source paired with an absorption grating (also known as source grating). The performance of the MAAT source can be optimized with respect to the areal density, dimensions, and choice of material for the microstructured metal inserts (MMI) and the substrate in which they are embedded. In this paper, we analyze the x-ray generation efficiency per incident electron, relative fraction of x-rays generated by MMI and substrate, x-ray spectrum, and angular distribution via Monte Carlo simulation. Based on the simulation results, the optimal parameters are obtained for a MAAT with incident electron energies from 30 keV to 120 keV. The corresponding temperature distribution within the MAAT is also simulated for the optimal set of the parameters via finite element analysis. As demonstrated by the thermal analysis data, the maximum allowable electron-beam power loading was derived that allows a stable operation of the transmission MAAT.


Asunto(s)
Interferometría/instrumentación , Interferometría/normas , Modelos Teóricos , Imagen Molecular/métodos , Método de Montecarlo , Difracción de Rayos X/instrumentación , Simulación por Computador , Electrodos , Diseño de Equipo , Interferometría/métodos
18.
Chem Commun (Camb) ; 55(8): 1052-1055, 2019 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-30608504

RESUMEN

Biological X-ray fluorescence microscopy (XFM) is an important tool for determining quantitative distributions of bioinorganics and essential trace elements. Here we present a new analysis approach for rapid nanoscale ptychographic imaging and simultaneous chemical mapping of large radiation sensitive specimens without image degradation associated with probe evolution.

19.
Rev Sci Instrum ; 90(8): 083701, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31472643

RESUMEN

Motivated by the advanced photon source upgrade, a new hard X-ray microscope called "Velociprobe" has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector continuous frame rate of 200 Hz. Using a higher flux X-ray source provided by double-multilayer monochromator, we achieve 10 nm resolution for an integrated circuit sample in an ultrafast scan with a detector's full continuous frame rate of 3000 Hz (0.33 ms per exposure), resulting in an outstanding imaging rate of 9 × 104 resolution elements per second.

20.
Environ Sci Pollut Res Int ; 25(17): 16427-16433, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28940161

RESUMEN

Animal studies show that exposure to the environmental pollutant 3,3',4,4',5-pentachlorobiphenyl (PCB126) causes alterations in hepatic metals as measured in acid-digested volume-adjusted tissue. These studies lack the detail of the spatial distribution within the liver. Here we use X-ray fluorescence microscopy (XFM) to assess the spatial distribution of trace elements within liver tissue. Liver samples from male Sprague Dawley rats, treated either with vehicle or PCB126, were formalin fixed and paraffin embedded. Serial sections were prepared for traditional H&E staining or placed on silicon nitride windows for XFM. With XFM, metal gradients between the portal triad and the central vein were seen, especially with copper and iron. These gradients change with exposure to PCB126, even reverse. This is the first report of how micronutrients vary spatially within the liver and how they change in response to toxicant exposure. In addition, high concentrations of zinc clusters were discovered in the extracellular space. PCB126 treatment did not affect their presence, but did alter their elemental makeup suggesting a more general biological function. Further work is needed to properly evaluate the gradients and their alterations as well as classify the zinc clusters to determine their role in liver function and zinc homeostasis.


Asunto(s)
Cobre/química , Hierro/química , Metales/química , Micronutrientes/química , Bifenilos Policlorados/química , Oligoelementos/química , Zinc/química , Animales , Cobre/metabolismo , Homeostasis , Hierro/metabolismo , Hígado , Micronutrientes/metabolismo , Bifenilos Policlorados/metabolismo , Ratas , Ratas Sprague-Dawley , Zinc/metabolismo
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda