Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Dent J (Basel) ; 12(7)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39057005

RESUMEN

Objective: To determine the effect of grit-blasting before and after sintering on the surface roughness of zirconia and the micro-tensile bond strength of a pressable veneering ceramic to zirconia. Methods: Pre-sintered zirconia blocks (IPS e.max ZirCAD, Ivoclar) were divided into four test groups of three specimens each and a control group ('CTR'; no surface treatment). Pre-S-30, Pre-S-50, and Pre-S-110 were grit-blasted with 30-µm SiO2-coated Al2O3, 50-µm Al2O3 and 110-µm Al2O3 particles, respectively, before sintering. Post-S-30 was grit-blasted with 30-µm SiO2-coated Al2O3 after sintering. For each treatment, the surface roughness was measured (Ra, Perthometer M4P, Mahr Perthen). After sintering the zirconia blocks, a liner was applied and a pressable ceramic (IPS e.max ZirPress, Ivoclar) was heat-pressed. Sixteen microbars were obtained from each block and submitted to micro-tensile bond-strength (µTBS) testing. Data were analyzed with one-way ANOVA. Any correlation between Ra and µTBS was evaluated (Sperman test). Results: Grit-blasting before sintering with 110-µm Al2O3 (RaPre-S-110 = 3.4 ± 0.4 µm), 50-µm Al2O3 (RaPre-S-50 = 2.3 ± 0.5 µm), and 30-µm SiO2-coated Al2O3 (RaPre-S-30 = 1.2 ± 0.2 µm) resulted in significantly higher roughness than grit-blasting after sintering with 30-µm SiO2-coated Al2O3 (RaPost-S-30 = 0.5 ± 0.1 µm). The highest µTBS was measured when the sintered zirconia was grit-blasted with 30-µm SiO2-coated Al2O3 (µTBSPost-S-30 = 28.5 ± 12.6 MPa), which was significantly different from that of specimens that were grit-blasted before sintering (µTBSPre-S-30 = 21.8 ± 10.4; µTBSPre-S-50 = 24.1 ± 12.6; µTBSPre-S-110 = 26.4 ± 14.1) or were not grit-blasted (µTBSCTR = 20.2 ± 11.2). Conclusions: Grit-blasting zirconia before sintering enhanced the surface roughness proportionally to the particle size of the sand used. Grit-blasting with 30-µm SiO2-coated Al2O3 after sintering improved bonding of the veneering ceramic to zirconia. Clinical Significance: As grit-blasting with 30-µm SiO2-coated Al2O3 after sintering improved bonding of the veneering ceramic to zirconia, it may reduce veneering ceramic fractures/chipping.

2.
Clin Oral Investig ; 17(8): 1911-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23197284

RESUMEN

OBJECTIVES: A dental adhesive without small and hydrophilic monomers such as 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate (TEGDMA) would be beneficial in order to avoid contact allergies. However, these monomers are important to increase infiltration and polymerization of the adhesive. Therefore, the purpose of this study was to evaluate the bonding effectiveness and bond durability of a more hydrophobic and biocompatible adhesive as compared to a conventional three-step etch-and-rinse adhesive. METHODS: Sixteen non-carious human third molars were used to determine the micro-tensile bond strength testing (µTBS) and interfacial ultrastructure by transmission electron microscopy (TEM) of the more hydrophobic cmf adhesive system (Saremco) adhesive as compared to the control OptiBond FL (Kerr). RESULTS: The more hydrophobic and biocompatible three-step etch-and-rinse adhesive was able to produce a reasonable short-time bonding effectiveness. In the long term, the collagen fibrils in the hybrid layer were not effectively protected and were prone to hydrolytic degradation. As a result, long-term bonding effectiveness of this novel adhesive was very low. CONCLUSIONS: Application of a more hydrophobic adhesive without altering the application procedure considerably results in a reduced durability of the created bond CLINICAL RELEVANCE: Omitting small and hydrophilic components from the adhesive formulation may impair the durability of your composite restoration.


Asunto(s)
Grabado Ácido Dental/métodos , Caries Dental/terapia , Cementos Dentales , Maloclusión Clase I de Angle/terapia , Recubrimiento Dental Adhesivo , Humanos , Hidrólisis , Microscopía Electrónica de Transmisión , Resistencia a la Tracción
3.
Clin Implant Dent Relat Res ; 17(4): 639-45, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24238310

RESUMEN

PURPOSE: The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. MATERIALS AND METHODS: Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva implant displaying significant larger inter-thread dimensions than the OsseoSpeed implant. Implants were installed in the parietal bone of 12 domestic pigs and left for healing for either 1 or 3 months. Implant osseointegration was evaluated by quantitative histology (bone volume relative to the tissue volume [BV/TV]; bone-to-implant contact [BIC]) for distinct implant regions (collar, body, total implant length) with specific implant thread features. The Wilcoxon-Mann-Whitney nonparametric test with α = 0.05 was performed. RESULTS: An inferior amount of bone enveloping the Aadva implant compared with the OsseoSpeed implant was observed, in particular at the implant body part with its considerable inter-thread gaps (p < .05). Concomitantly, the Aadva macro-design negatively affected the amount of bone in direct contact with the implant for this specific implant part (p < .05), and resulted in an overall impaired implant osseointegration at the initial healing stage (total implant length; 1-month healing; p < .05). CONCLUSION: Although the Aadva implant displayed a clinically acceptable level of osseointegration, the findings demonstrate that implant macro-design features can impact the dynamics of implant osseointegration. Consideration of specific implant macro-design features should be made relative to the biological and mechanical microenvironment.


Asunto(s)
Implantes Dentales , Oseointegración/efectos de los fármacos , Titanio/uso terapéutico , Animales , Humanos , Modelos Animales , Porcinos
4.
Acta Biomater ; 10(2): 986-95, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24161385

RESUMEN

Bone growth on and into implants exhibiting substantial surface porosity is a promising strategy in order to improve the long-term stable fixation of bone implants. However, the reliability in clinical applications remains a point of discussion. Most attention has been dedicated to the role of macroporosity, leading to the general consensus of a minimal pore size of 50-100 µm in order to allow bone ingrowth. In this in vivo study, we assessed the feasibility of early bone ingrowth into a predominantly microporous Ti coating with an average thickness of 150 µm and the hypothesis of improving the bone response through surface modification of the porous coating. Implants were placed in the cortical bone of rabbit tibiae for periods of 2 and 4 weeks and evaluated histologically and histomorphometrically using light microscopy and scanning electron microscopy. Bone with osteocytes encased in the mineralized matrix was found throughout the porous Ti coating up to the coating/substrate interface, highlighting that osseointegration of microporosities (<10 µm) was achievable. The bone trabeculae interweaved with the pore struts, establishing a large contact area which might enable an improved load transfer and stronger implant/bone interface. Furthermore, there was a clear interconnection with the surrounding cortical bone, suggesting that mechanical interlocking of the coating in the host bone in the long term is possible. When surface modifications inside the porous structure further reduced the interconnective pore size to the submicrometer level, bone ingrowth was impaired. On the other hand, application of a sol-gel-derived bioactive glass-ceramic coating without altering the pore characteristics was found to significantly improve bone regeneration around the coating, while still supporting bone ingrowth.


Asunto(s)
Huesos/efectos de los fármacos , Materiales Biocompatibles Revestidos/farmacología , Prótesis e Implantes , Titanio/farmacología , Animales , Microscopía Electrónica de Rastreo , Conejos , Propiedades de Superficie
5.
Dent Mater J ; 30(1): 7-13, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21282894

RESUMEN

Dentin is a variable substrate with properties that change considerable in a single surface. The purpose of this study was to evaluate the bonding effectiveness to these different dentin locations and evaluate these differences over time. After bonding procedures with five different adhesives, small micro-tensile bond strength (µTBS) beams were prepared and dichotomously divided in 'center' and 'periphery' dentin specimens. After 1 week, 3, 6 and 12 months of water storage the µTBS of specimens of each group was determined, enabling a paired study design. The bond strengths of both etch&rinse adhesives were insensitive to regional variability. For the two-step self-etch adhesives, a marked increase in bond strengths was observed with increasing amount of intertubular dentin. Regional variability did not affect the long-term bonding effectiveness for any of the adhesives tested. In conclusion, only for the mild self-etch adhesives, µTBS to 'periphery' dentin was higher than for the 'center' specimens.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/farmacología , Dentina/efectos de los fármacos , Cementos de Resina/farmacología , Adolescente , Análisis de Varianza , Grabado Dental/métodos , Análisis del Estrés Dental , Dentina/anatomía & histología , Dentina/química , Recubrimientos Dentinarios/química , Humanos , Estudios Longitudinales , Ensayo de Materiales , Metacrilatos/química , Metacrilatos/farmacología , Cementos de Resina/química , Resistencia a la Tracción , Diente/anatomía & histología , Agua/química , Adulto Joven
6.
Dent Mater ; 26(6): 579-88, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20347481

RESUMEN

OBJECTIVES: To optimize a microtomographic (micro-CT) technique to quantitatively evaluate the effectiveness of contemporary caries-excavation techniques. METHODS: A beam-hardening curve was obtained from an initial reconstruction of a wedge-shaped hydroxyapatite (HAp) block and fitted with a 5th order polynomial function, after which each micro-CT tooth slice was corrected accordingly. Calibration of the 8-bit gray values into mineral-density values was obtained by scanning, reconstructing and processing volume of interests (VOIs) of HAp phantoms with different mineral densities (0.25, 0.75, 3.14g/cm(3)). One carious tooth was scanned before and after caries removal with an experimental enzyme-based gel. After reconstruction, a 3D-median filter was applied to each micro-CT slice, and a connected threshold grower algorithm was used to blank-out undesired structures in each slice. Volume rendering with a look-up-table (LUT), based on mineral densities, was accomplished for the tooth before and after caries removal. Finally, the actual volume of excavated tissue was quantified. RESULTS: Correction for beam hardening produced tooth slices with relatively homogeneous gray values along the whole area of enamel and dentin. Accurate mineral-density values were obtained for enamel, dentin and carious regions (2.89, 1.74 and 0.27g/cm(3), respectively). After pre-processing (3D-median filtering and connected threshold grower algorithm), acceptable segmentation of carious dentin based on gray values was accomplished (Otsu method, gray value=75 or mineral density=1.12g/cm(3)), from which quantitative volumetric parameters were calculated. SIGNIFICANCE: Accurate calibration, standardization of scanning and reconstruction steps and adequate pre-processing of micro-CT slices allowed detailed volumetric calculation of caries-excavation techniques.


Asunto(s)
Caries Dental/patología , Preparación de la Cavidad Dental/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Microtomografía por Rayos X/métodos , Absorciometría de Fotón , Algoritmos , Anatomía Transversal , Artefactos , Calibración , Caries Dental/terapia , Esmalte Dental/patología , Dentina/patología , Durapatita/química , Humanos , Imagenología Tridimensional/métodos , Minerales/química , Fantasmas de Imagen , Programas Informáticos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda