Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Vopr Virusol ; 68(4): 327-333, 2023 Sep 21.
Artículo en Ruso | MEDLINE | ID: mdl-38156589

RESUMEN

INTRODUCTION: Due to the increased incidence of measles in Russia and in many other regions of the world, vaccines for the measles prevention are especially in demand. Ensuring the quality of the measles vaccine for effective disease prevention is within the scope of the tasks of the state policy of our country. OBJECTIVE: Evaluation of the experience of using a pharmacopoeial standard material of measles vaccine activity for measurement of the specific activity of the measles virus in vaccines with a measles component that are used in the Russian Federation for measles prevention. MATERIALS AND METHODS: The object of the study was the Pharmacopoeia reference material (PRM) of the activity of the live measles vaccine of series 10. The activity of PRM was analyzed when determining the specific activity of the measles, mumps-measles and combined vaccines for the prevention of measles, rubella and mumps, as well as based on the materials of the summary protocols for the production of these vaccines. RESULTS: The titer of the measles virus in the PRM for each determination of the specific activity of the measles virus in vaccines in the Scientific Centre for Expert Evaluation of Medicinal Products in 2021-2022, as well as according to the summary production protocols, was within the boundaries of the certified value (4.63 ± 0.5) lgTCD50/0.5 ml, and the test results met the acceptance criteria in accordance with the requirements of regulatory documentation. During the observation period, the average value of the PRM titer (4.61 lgTCD50/0.5 ml) practically did not differ compared to the average value of the certified characteristics of the PRM, the standard deviation of the mean value of the measles virus titer in the PRM did not exceed 0.15 lgTCD50, which indicated the stability of the analytical work at the enterprise and in IC. CONCLUSION: The data obtained indicate the stable activity of PRM, the correctness of the determination of the measles virus titer in the vaccination dose of the vaccine, and the validity of the method for monitoring the specific activity of the measles virus in vaccines.


Asunto(s)
Sarampión , Paperas , Rubéola (Sarampión Alemán) , Humanos , Vacuna Antisarampión , Vacuna contra el Sarampión-Parotiditis-Rubéola/uso terapéutico , Paperas/prevención & control , Sarampión/epidemiología , Sarampión/prevención & control , Rubéola (Sarampión Alemán)/prevención & control , Virus del Sarampión/genética , Anticuerpos Antivirales , Vacuna contra la Parotiditis
2.
Artículo en Ruso | MEDLINE | ID: mdl-19338238

RESUMEN

Part of the Federal System of External Quality Assessment of Clinical Laboratory Tests named "PCR-identification of hepatitis C virus (HCV)" and aimed at detection of HCV RNA by polymerase chain reaction (PCR) assay is functioning from 2000. Ninety, 98, and 112 laboratories from more than 50 regions of Russian Federation participated in it in 2000, 2006, and 2007 respectively. Analysis of results of control samples tests, which were performed by participated laboratories, showed increasing proportion of method of amplification in the presence of fluorescent-marked probes both in real-time and in end-point regimens. In these circumstances, significant increase of specificity and sensitivity of tests was observed. In 2007, proportion of correct results obtained by the participants for tests with negative control samples was 96 - 97%, whereas during detection of HCV RNA in concentration 10(3) IU/ml the proportion of correct results was 80 - 83%. Significant proportion of laboratories, which did not detect HCV RNA in concentration 10(3) IU/ml, points on the necessity to improve sensitivity of this important method of laboratory tests.


Asunto(s)
Hepacivirus/aislamiento & purificación , Hepatitis C/diagnóstico , Reacción en Cadena de la Polimerasa/estadística & datos numéricos , Reacción en Cadena de la Polimerasa/tendencias , ARN Viral/análisis , Reacciones Falso Positivas , Hepacivirus/genética , Humanos , Reacción en Cadena de la Polimerasa/normas , Control de Calidad , Federación de Rusia
3.
Vopr Virusol ; 63(2): 90-96, 2018 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-36494927

RESUMEN

Until recently Rubella has been a wide spread infection. Thanks to vaccination against rubella, taking part in the global elimination program of "manageable infections" of WHO and adoption of the program "Elimination of measles and rubella in Russian Federation" the morbidity index of rubella has reached the sporadic level. One of the determining conditions of rubella elimination is application of high-quality vaccines that satisfy international standards. In Russian Federation, foreign rubella vaccines certified in our country were used for several years. In 2008, the commercial production of domestic vaccine began. It is widely known that the required quality of immunobiological medications is achieved using adequate production conditions and standard technological process. That is why during the production of domestic rubella vaccine, all the rules and requirements of Russian regulatory authorities and international recommendations are followed. In this article, a retrospective analysis of domestic vaccine against rubella according to laboratory options of quality in 2012-2017 is given. The results of the analysis show that the medication demonstrates stable high quality that is indicative of secure production technologies.

4.
Artículo en Ruso | MEDLINE | ID: mdl-15881940

RESUMEN

The method for the diagnostic value evaluation of preparations, based on the calculation of the accuracy of test results and taking into account the spread of the diagnosed disease (the comparison of the PCR test systems for the diagnostics of hepatitis B and ureaplasmosis) is proposed. As shown in this work, evaluations obtained with the use of this method coincide with those obtained on the basis of prognostic value, but are more convenient in use and provide additional information.


Asunto(s)
Hepatitis B/diagnóstico , Reacción en Cadena de la Polimerasa/normas , Infecciones por Ureaplasma/diagnóstico , ADN Bacteriano/análisis , ADN Viral/análisis , Virus de la Hepatitis B/genética , Humanos , Control de Calidad , Sensibilidad y Especificidad , Ureaplasma/genética
5.
Vopr Virusol ; 41(1): 21-4, 1996.
Artículo en Ruso | MEDLINE | ID: mdl-8669141

RESUMEN

Ninety-eight lots of commercial antirabies vaccine manufactured by Immunopreparat Research and Production Amalgamation have been tested using enzyme immunoassay system for the detection of rabies virus antigens. Comparison of different variants of interpreting and expressing the results helped define the optimal method for assessment of vaccine titer and reference values: optical density value equal to 0.2 is taken as the cut-off. Antigenic activity of the vaccine may be expressed in international units, similarly as immunogenic activity.


Asunto(s)
Antígenos Virales/análisis , Vacunas Antirrábicas/inmunología , Antígenos Virales/inmunología , Técnicas para Inmunoenzimas
6.
Vopr Virusol ; 47(5): 38-40, 2002.
Artículo en Ruso | MEDLINE | ID: mdl-12522969

RESUMEN

The stability of hepatitis C virus (HPC) RNA concentration in 5 human plasma samples after storage at +22 degrees C for two months, at -20 degrees C, and +4 degrees C for six months after 10 freezing-unfreezing cycles was evaluated. In this study, the concentration of HCV RNA in the samples was stable after six months of storage at -20 degrees C. The concentration of HCV RNA decreased on the average of 92% after 2-month storage at +22 degrees C. After six months of storage at +4 degrees C and after 10 freezing-unfreezing cycles, that decreased by 28 and 42%, respectively. Based on their own findings, the authors developed a HCV-RNA panel containing 5 positive human plasma samples with RNA levels of 103-105 IU/ml. The panel may be recommended both for the standardization of PCR kits and for the intra- and interlaboratory quality control of PCR laboratories.


Asunto(s)
Hepacivirus/genética , ARN Viral/sangre , Criopreservación , Congelación , Hepacivirus/aislamiento & purificación , Humanos , Manejo de Especímenes
7.
Vopr Virusol ; 39(2): 68-71, 1994.
Artículo en Ruso | MEDLINE | ID: mdl-8017056

RESUMEN

Rocket immunoelectrophoresis (RIE) was shown to be useful for the evaluation of glycoprotein (GP) content in concentrated rabies vaccines, and disintegron B., a zwitterionic detergent made in this country, for treatment of the vaccines for these evaluations. The values of GP content obtained by RIE and single radial immunodiffusion test were similar. The highest values were obtained for all the vaccines tested with anti-PM GP serum compared with anti-ERA and Vnukovo-32 GP serum. When anti-PM and anti-Vnukovo-32 GP sera were used for RIE two components were revealed in the vaccines. All the preparations under study contained soluble GP.


Asunto(s)
Glicoproteínas/análisis , Vacunas Antirrábicas/análisis , Betaína/análogos & derivados , Cromatografía , Detergentes , Inmunodifusión , Inmunoelectroforesis/métodos , Indicadores y Reactivos , Vacunas Antirrábicas/aislamiento & purificación , Solubilidad , Ultracentrifugación , Ultrafiltración
8.
Vopr Virusol ; 47(5): 12-6, 2002.
Artículo en Ruso | MEDLINE | ID: mdl-12522962

RESUMEN

The test system developed at the Central Research Institute of Epidemiology, Ministry of Health of the Russian Federation for identification of hepatitis C virus RNA was studied. The sensitivity of the test system which the rate of similar results was 100% with its 5-fold reproduction was evaluated. That was 5 x 103 genomic equivalents (or international units) per ml of a sample. A scheme for evaluation of the reproductibility of test systems based on the polymerase chain reaction (PCR) by using model samples is proposed. Whether it can be used for intra- and extra-laboratory assessment of the quality of PCR analyses is discussed.


Asunto(s)
Hepacivirus/aislamiento & purificación , Hepatitis C/diagnóstico , Reacción en Cadena de la Polimerasa/normas , ARN Viral/sangre , Hepacivirus/genética , Hepatitis C/virología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Zh Mikrobiol Epidemiol Immunobiol ; (4): 101-4, 1979 Apr.
Artículo en Ruso | MEDLINE | ID: mdl-108881

RESUMEN

Various methods of isolating allergen fractions from N. meningitidis, N. gonorrhoeae and N. perflava were tested. The biological activity of the preparation was found to depend on the method of its production, which determined its chemical composition. When gonococcal and meningococcal allergens and N. perflava allergen were used in skin tests, cross reactions were observed. Nevertheless, as the intensity and size of skin reaction was much greater when a homologous preparation was administered, it was possible to differentiate the presence of sensitization to a definite microbial species. Electrophoresis in acrylamide gel revealed the heterogeneity of allergen preparations. The ability of the preparation to induce skin reaction was not connected with its serological properties.


Asunto(s)
Alérgenos/aislamiento & purificación , Neisseria/inmunología , Alérgenos/análisis , Alérgenos/inmunología , Animales , Reacciones Cruzadas , Medios de Cultivo , Cobayas , Inmunoquímica , Neisseria gonorrhoeae/inmunología , Neisseria meningitidis/inmunología , Pruebas de Precipitina , Pruebas Cutáneas
10.
Artículo en Ruso | MEDLINE | ID: mdl-10876905

RESUMEN

The fractional composition of commercial immunoglobulin was studied by the method of gel filtration on ultragel AcA-34 and the possibility of its use for the calibration of a chromatographic column was shown. The fractionation of a specimen of IgG revealed the presence of 4 fractions. Their molecular weights corresponded to dimers, monomers, Fab fragments and low-molecular peptides. The qualitative fractional composition of the preparation was shown to be stable during 3 years of storage, as well as after keeping the preparation at 37 degrees C for 1 month. The attested characteristic of each IgG fraction, the distribution coefficient (Kav), was established. The use of a specimen of immunoglobulin obtained with the use of the modified Cohn's method--as calibrant will make it possible to calibrate the columns for a shorter period and to control the correctness of the analysis.


Asunto(s)
Cromatografía en Gel/métodos , Inmunoglobulina G , Calibración/normas , Cromatografía en Gel/instrumentación , Cromatografía en Gel/normas , Cromatografía en Gel/estadística & datos numéricos , Estabilidad de Medicamentos , Humanos , Inmunoglobulina G/química , Peso Molecular , Factores de Tiempo
11.
Klin Lab Diagn ; (7): 12-4, 2000 Jul.
Artículo en Ruso | MEDLINE | ID: mdl-10981387

RESUMEN

A method for measuring phenol by gas liquid chromatography has been developed. Metrological characteristics of the method were evaluated: similarity (V no more than 1.62%), reproducibility (V no more than 1.60%), and correctness (98.7-102.3% phenol is detected). The sensitivity of the method is 5 mcg/ml. The method can be used for measuring phenol in noninfectious allergens, tuberculin, and some vaccines.


Asunto(s)
Alérgenos/química , Cromatografía de Gases , Vacunas/química , Modelos Teóricos , Fenol/análisis , Sensibilidad y Especificidad , Tuberculina/química
15.
Probl Tuberk ; (3): 41-4, 1999.
Artículo en Ruso | MEDLINE | ID: mdl-10420768

RESUMEN

The time course of cytological parameters of alveolar lavage fluid in restrictive lung disease of tuberculous or other genesis during tuberculin provocative test was studied. A focal response as higher levels of alveolar macrophages, plasma and epithelioid cells was noted in 62.5% of patients with tuberculosis. The method promotes greater diagnostic efficiency for pulmonary tuberculosis.


Asunto(s)
Líquido del Lavado Bronquioalveolar/citología , Neoplasias Pulmonares/diagnóstico , Neumonía/diagnóstico , Tuberculosis Pulmonar/diagnóstico , Adolescente , Adulto , Anciano , Diagnóstico Diferencial , Células Epitelioides/patología , Femenino , Humanos , Macrófagos Alveolares/patología , Masculino , Persona de Mediana Edad , Células Plasmáticas/patología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda