J Cardiovasc Magn Reson ; 17: 73, 2015 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-26264813

RESUMEN

BACKGROUND: Whether T1-mapping cardiovascular magnetic resonance (CMR) can accurately quantify the area-at-risk (AAR) as delineated by T2 mapping and assess myocardial salvage at 3T in reperfused ST-segment elevation myocardial infarction (STEMI) patients is not known and was investigated in this study. METHODS: 18 STEMI patients underwent CMR at 3T (Siemens Bio-graph mMR) at a median of 5 (4-6) days post primary percutaneous coronary intervention using native T1 (MOLLI) and T2 mapping (WIP #699; Siemens Healthcare, UK). Matching short-axis T1 and T2 maps covering the entire left ventricle (LV) were assessed by two independent observers using manual, Otsu and 2 standard deviation thresholds. Inter- and intra-observer variability, correlation and agreement between the T1 and T2 mapping techniques on a per-slice and per patient basis were assessed. RESULTS: A total of 125 matching T1 and T2 mapping short-axis slices were available for analysis from 18 patients. The acquisition times were identical for the T1 maps and T2 maps. 18 slices were excluded due to suboptimal image quality. Both mapping sequences were equally prone to susceptibility artifacts in the lateral wall and were equally likely to be affected by microvascular obstruction requiring manual correction. The Otsu thresholding technique performed best in terms of inter- and intra-observer variability for both T1 and T2 mapping CMR. The mean myocardial infarct size was 18.8 ± 9.4 % of the LV. There was no difference in either the mean AAR (32.3 ± 11.5 % of the LV versus 31.6 ± 11.2 % of the LV, P = 0.25) or myocardial salvage index (0.40 ± 0.26 versus 0.39 ± 0.27, P = 0.20) between the T1 and T2 mapping techniques. On a per-slice analysis, there was an excellent correlation between T1 mapping and T2 mapping in the quantification of the AAR with an R(2) of 0.95 (P < 0.001), with no bias (mean ± 2SD: bias 0.0 ± 9.6 %). On a per-patient analysis, the correlation and agreement remained excellent with no bias (R(2) 0.95, P < 0.0001, bias 0.7 ± 5.1 %). CONCLUSIONS: T1 mapping CMR at 3T performed as well as T2 mapping in quantifying the AAR and assessing myocardial salvage in reperfused STEMI patients, thereby providing an alternative CMR measure of the the AAR.


Asunto(s)
Imagen por Resonancia Cinemagnética , Infarto del Miocardio/terapia , Miocardio/patología , Intervención Coronaria Percutánea , Anciano , Área Bajo la Curva , Artefactos , Circulación Coronaria , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Microcirculación , Persona de Mediana Edad , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Necrosis , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Curva ROC , Recuperación de la Función , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
2.
Circ Cardiovasc Imaging ; 9(3): e003900, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26926269

RESUMEN

BACKGROUND: Hybrid positron emission tomography and magnetic resonance allows the advantages of magnetic resonance in tissue characterizing the myocardium to be combined with the unique metabolic insights of positron emission tomography. We hypothesized that the area of reduced myocardial glucose uptake would closely match the area at risk delineated by T2 mapping in ST-segment-elevation myocardial infarction patients. METHODS AND RESULTS: Hybrid positron emission tomography and magnetic resonance using (18)F-fluorodeoxyglucose (FDG) for glucose uptake was performed in 21 ST-segment-elevation myocardial infarction patients at a median of 5 days. Follow-up scans were performed in a subset of patients 12 months later. The area of reduced FDG uptake was significantly larger than the infarct size quantified by late gadolinium enhancement (37.2±11.6% versus 22.3±11.7%; P<0.001) and closely matched the area at risk by T2 mapping (37.2±11.6% versus 36.3±12.2%; P=0.10, R=0.98, bias 0.9±4.4%). On the follow-up scans, the area of reduced FDG uptake was significantly smaller in size when compared with the acute scans (19.5 [6.3%-31.8%] versus 44.0 [21.3%-55.3%]; P=0.002) and closely correlated with the areas of late gadolinium enhancement (R 0.98) with a small bias of 2.0±5.6%. An FDG uptake of ≥45% on the acute scans could predict viable myocardium on the follow-up scan. Both transmural extent of late gadolinium enhancement and FDG uptake on the acute scan performed equally well to predict segmental wall motion recovery. CONCLUSIONS: Hybrid positron emission tomography and magnetic resonance in the reperfused ST-segment-elevation myocardial infarction patients showed reduced myocardial glucose uptake within the area at risk and closely matched the area at risk delineated by T2 mapping. FDG uptake, as well as transmural extent of late gadolinium enhancement, acutely can identify viable myocardial segments.


Asunto(s)
Circulación Coronaria , Imagen por Resonancia Cinemagnética , Imagen Multimodal/métodos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Imagen de Perfusión Miocárdica/métodos , Miocardio/patología , Intervención Coronaria Percutánea , Tomografía de Emisión de Positrones , Anciano , Medios de Contraste , Femenino , Fluorodesoxiglucosa F18/metabolismo , Compuestos Heterocíclicos , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/metabolismo , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Miocardio/metabolismo , Compuestos Organometálicos , Valor Predictivo de las Pruebas , Radiofármacos/metabolismo , Recuperación de la Función , Factores de Tiempo , Supervivencia Tisular , Resultado del Tratamiento