Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Proc Natl Acad Sci U S A ; 116(6): 2232-2236, 2019 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-30674677

RESUMEN

Circulating tumor cells (CTCs) play a fundamental role in cancer progression. However, in mice, limited blood volume and the rarity of CTCs in the bloodstream preclude longitudinal, in-depth studies of these cells using existing liquid biopsy techniques. Here, we present an optofluidic system that continuously collects fluorescently labeled CTCs from a genetically engineered mouse model (GEMM) for several hours per day over multiple days or weeks. The system is based on a microfluidic cell sorting chip connected serially to an unanesthetized mouse via an implanted arteriovenous shunt. Pneumatically controlled microfluidic valves capture CTCs as they flow through the device, and CTC-depleted blood is returned back to the mouse via the shunt. To demonstrate the utility of our system, we profile CTCs isolated longitudinally from animals over 4 days of treatment with the BET inhibitor JQ1 using single-cell RNA sequencing (scRNA-Seq) and show that our approach eliminates potential biases driven by intermouse heterogeneity that can occur when CTCs are collected across different mice. The CTC isolation and sorting technology presented here provides a research tool to help reveal details of how CTCs evolve over time, allowing studies to credential changes in CTCs as biomarkers of drug response and facilitating future studies to understand the role of CTCs in metastasis.


Asunto(s)
Citometría de Flujo , Técnicas Analíticas Microfluídicas , Microfluídica , Neoplasias/diagnóstico , Neoplasias/metabolismo , Células Neoplásicas Circulantes/metabolismo , Animales , Biomarcadores de Tumor , Línea Celular Tumoral , Modelos Animales de Enfermedad , Citometría de Flujo/métodos , Perfilación de la Expresión Génica/métodos , Ratones , Microfluídica/métodos , Neoplasias/genética , Células Neoplásicas Circulantes/patología , Análisis de la Célula Individual/métodos , Transcriptoma
2.
Proc Natl Acad Sci U S A ; 111(4): 1310-5, 2014 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-24474753

RESUMEN

Physical characterization of nanoparticles is required for a wide range of applications. Nanomechanical resonators can quantify the mass of individual particles with detection limits down to a single atom in vacuum. However, applications are limited because performance is severely degraded in solution. Suspended micro- and nanochannel resonators have opened up the possibility of achieving vacuum-level precision for samples in the aqueous environment and a noise equivalent mass resolution of 27 attograms in 1-kHz bandwidth was previously achieved by Lee et al. [(2010) Nano Lett 10(7):2537-2542]. Here, we report on a series of advancements that have improved the resolution by more than 30-fold, to 0.85 attograms in the same bandwidth, approaching the thermomechanical noise limit and enabling precise quantification of particles down to 10 nm with a throughput of more than 18,000 particles per hour. We demonstrate the potential of this capability by comparing the mass distributions of exosomes produced by different cell types and by characterizing the yield of self-assembled DNA nanoparticle structures.


Asunto(s)
Nanopartículas del Metal , Exosomas , Oro/química , Límite de Detección , Peso Molecular , Reproducibilidad de los Resultados , Soluciones
3.
Nat Methods ; 7(8): 634-6, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20639868

RESUMEN

We demonstrate a high-throughput platform for cellular-resolution in vivo chemical and genetic screens on zebrafish larvae. The system automatically loads zebrafish from reservoirs or multiwell plates, and positions and rotates them for high-speed confocal imaging and laser manipulation of both superficial and deep organs within 19 s without damage. We performed small-scale test screening of retinal axon guidance mutants and neuronal regeneration assays in combination with femtosecond laser microsurgery.


Asunto(s)
Axones , Tamizaje Masivo/métodos , Microscopía Confocal/instrumentación , Retina/citología , Animales , Automatización , Embrión no Mamífero , Diseño de Equipo , Terapia por Láser , Modelos Animales , Mutación , Pez Cebra
4.
Commun Biol ; 5(1): 1295, 2022 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-36435843

RESUMEN

Functional precision medicine offers a promising complement to genomics-based cancer therapy guidance by testing drug efficacy directly on a patient's tumor cells. Here, we describe a workflow that utilizes single-cell mass measurements with inline brightfield imaging and machine-learning based image classification to broaden the clinical utility of such functional testing for cancer. Using these image-curated mass measurements, we characterize mass response signals for 60 different drugs with various mechanisms of action across twelve different cell types, demonstrating an improved ability to detect response for several slow acting drugs as compared with standard cell viability assays. Furthermore, we use this workflow to assess drug responses for various primary tumor specimen formats including blood, bone marrow, fine needle aspirates (FNA), and malignant fluids, all with reports generated within two days and with results consistent with patient clinical responses. The combination of high-resolution measurement, broad drug and malignancy applicability, and rapid return of results offered by this workflow suggests that it is well-suited to performing clinically relevant functional assessment of cancer drug response.


Asunto(s)
Antineoplásicos , Neoplasias , Humanos , Neoplasias/tratamiento farmacológico , Recuento de Células , Flujo de Trabajo , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico
6.
Nat Biotechnol ; 34(10): 1052-1059, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27598230

RESUMEN

Methods to rapidly assess cell growth would be useful for many applications, including drug susceptibility testing, but current technologies have limited sensitivity or throughput. Here we present an approach to precisely and rapidly measure growth rates of many individual cells simultaneously. We flow cells in suspension through a microfluidic channel with 10-12 resonant mass sensors distributed along its length, weighing each cell repeatedly over the 4-20 min it spends in the channel. Because multiple cells traverse the channel at the same time, we obtain growth rates for >60 cells/h with a resolution of 0.2 pg/h for mammalian cells and 0.02 pg/h for bacteria. We measure the growth of single lymphocytic cells, mouse and human T cells, primary human leukemia cells, yeast, Escherichia coli and Enterococcus faecalis. Our system reveals subpopulations of cells with divergent growth kinetics and enables assessment of cellular responses to antibiotics and antimicrobial peptides within minutes.


Asunto(s)
Proliferación Celular/efectos de los fármacos , Proliferación Celular/fisiología , Evaluación Preclínica de Medicamentos/instrumentación , Ensayos Analíticos de Alto Rendimiento/instrumentación , Dispositivos Laboratorio en un Chip , Sistemas Microelectromecánicos/instrumentación , Evaluación Preclínica de Medicamentos/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Ensayos Analíticos de Alto Rendimiento/métodos , Sistemas Microelectromecánicos/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Transductores
7.
Nat Commun ; 6: 7070, 2015 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-25963304

RESUMEN

Simultaneously measuring multiple eigenmode frequencies of nanomechanical resonators can determine the position and mass of surface-adsorbed proteins, and could ultimately reveal the mass tomography of nanoscale analytes. However, existing measurement techniques are slow (<1 Hz bandwidth), limiting throughput and preventing use with resonators generating fast transient signals. Here we develop a general platform for independently and simultaneously oscillating multiple modes of mechanical resonators, enabling frequency measurements that can precisely track fast transient signals within a user-defined bandwidth that exceeds 500 Hz. We use this enhanced bandwidth to resolve signals from multiple nanoparticles flowing simultaneously through a suspended nanochannel resonator and show that four resonant modes are sufficient for determining their individual position and mass with an accuracy near 150 nm and 40 attograms throughout their 150-ms transit. We envision that our method can be readily extended to other systems to increase bandwidth, number of modes, or number of resonators.

8.
Lab Chip ; 11(24): 4174-80, 2011 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-22038401

RESUMEN

We present two methods by which single cells can be mechanically trapped and continuously monitored within the suspended microchannel resonator (SMR) mass sensor. Since the fluid surrounding the trapped cell can be quickly and completely replaced on demand, our methods are well suited for measuring changes in cell size and growth in response to drugs or other chemical stimuli. We validate our methods by measuring the density of single polystyrene beads and Saccharomyces cerevisiae yeast cells with a precision of approximately 10(-3) g cm(-3), and by monitoring the growth of single mouse lymphoblast cells before and after drug treatment.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Animales , Línea Celular , Tamaño de la Célula , Ratones , Peso Molecular , Poliestirenos/química , Saccharomyces cerevisiae/química
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda