Eur J Neurol ; 30(4): 982-990, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36635219

RESUMEN

BACKGROUND AND PURPOSE: Thinning of the retinal combined ganglion cell and inner plexiform layer (GCIP) as measured by optical coherence tomography (OCT) is a common finding in patients with multiple sclerosis. This study aimed to investigate whether a single retinal OCT analysis allows prediction of future disease activity after a first demyelinating event. METHODS: This observational cohort study included 201 patients with recently diagnosed clinically isolated syndrome or relapsing-remitting multiple sclerosis from two German tertiary referral centers. Individuals underwent neurological examination, magnetic resonance imaging, and OCT at baseline and at yearly follow-up visits. RESULTS: Patients were included at a median disease duration of 2.0 months. During a median follow-up of 59 (interquartile range = 43-71) months, 82% of patients had ongoing disease activity as demonstrated by failing the no evidence of disease activity 3 (NEDA-3) criteria, and 19% presented with confirmed disability worsening. A GCIP threshold of ≤77 µm at baseline identified patients with a high risk for NEDA-3 failure (hazard ratio [HR] = 1.7, 95% confidence interval [CI] = 1.1-2.8, p = 0.04), and GCIP measures of ≤69 µm predicted disability worsening (HR = 2.2, 95% CI = 1.2-4.3, p = 0.01). Higher rates of annualized GCIP loss increased the risk for disability worsening (HR = 2.5 per 1 µm/year increase of GCIP loss, p = 0.03). CONCLUSIONS: Ganglion cell thickness as measured by OCT after the initial manifestation of multiple sclerosis may allow early risk stratification as to future disease activity and progression.


Asunto(s)
Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Humanos , Células Ganglionares de la Retina/patología , Esclerosis Múltiple Recurrente-Remitente/patología , Esclerosis Múltiple/patología , Retina/patología , Estudios de Cohortes , Tomografía de Coherencia Óptica/métodos
2.
Eur J Neurol ; 28(12)2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34374178

RESUMEN

BACKGROUND AND PURPOSE: Peripapillary hyper-reflective ovoid masslike structures (PHOMS) are a novel finding during retinal optical coherence tomography in patients with multiple sclerosis (MS). To date, there are no data on the occurrence of PHOMS in early MS. The aim of this study was to investigate the frequency of PHOMS in patients with first diagnosed early relapsing-remitting MS (RRMS) and to search for associations of PHOMS with disease patterns in different MS subtypes. METHODS: This was a cross-sectional analysis in two different cohorts: cohort 1, consisting of early RRMS patients (n = 349); cohort 2, consisting of patients with primary progressive MS (PPMS) (n = 66) and RRMS (n = 65). RESULTS: Peripapillary hyper-reflective ovoid masslike structures were detected in 18.3% of patients with early RRMS. The occurrence of PHOMS was not associated with age, disease duration and disability. Investigating clinical patterns and the occurrence of PHOMS (cohort 2), an association of PHOMS with higher Expanded Disability Status Scale measures (PHOMS 4.9, 3.7-6.1; no PHOMS 3.5, 3.0-5.3; p = 0.03) and longer disease durations (PHOMS 6.5 years, 1.9-11.0; no PHOMS 1.0 years, 0.0-4.0, p = 0.0007) was found in patients with PPMS but not RRMS. After p value adjustment, the disease duration appeared to be more relevant (ß = 0.16, p = 0.06). CONCLUSION: Peripapillary hyper-reflective ovoid masslike structures were found in 18% of patients with early MS. The presence of PHOMS might be associated with disease progression only in PPMS but not RRMS, suggesting that PHOMS might be embedded in neurodegenerative processes.


Asunto(s)
Esclerosis Múltiple Crónica Progresiva , Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Estudios Transversales , Humanos , Esclerosis Múltiple/complicaciones , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple Crónica Progresiva/complicaciones , Esclerosis Múltiple Crónica Progresiva/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/complicaciones , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos