Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-37874020

RESUMEN

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estudios de Seguimiento , Readmisión del Paciente , Insuficiencia Cardíaca/etiología
2.
J Vasc Surg ; 78(5): 1313-1321, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37524153

RESUMEN

Registry Assessment of Peripheral Interventional Devices (RAPID) initiated the Pathways Program to provide a transparent, collaborative forum in which to pursue insights into multiple unresolved questions on benefit-risk of paclitaxel-coated devices, including understanding the basis of the mortality signal, without a demonstrable potential biological mechanism, and whether the late mortality signal could be artifact intrinsic to multiple independent prospective randomized data sources that did not prespecify death as a long-term end point. In response to the directive, the LEAN-Case Report Form working group focused on enhancements to the RAPID Phase I Minimum Core Data set through the addition of key clinical modifiers that would be more strongly linked to longer-term mortality outcomes after peripheral arterial disease intervention in the drug-eluting device era, with the goal to have future mortality signals more accurately examined.

3.
Prenat Diagn ; 42(10): 1235-1241, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35997139

RESUMEN

OBJECTIVE: Prenatal chorionicity assessment relies on ultrasound, which can be confounded by many factors. Noninvasive assessment of zygosity is possible using single nucleotide polymorphism (SNP)-based cell-free DNA testing. Our objective was to determine the relationship between provider-reported chorionicity and SNP-cfDNA assignment of twin zygosity. METHODS: All twin pregnancy blood samples received by a reference laboratory between September 27, 2017 and September 8, 2021 were included. Chorionicity assignment was requested on the requisition, recorded as; monochorionic (MC), dichorionic, or "don't know". SNP-cfDNA zygosity results, monozygotic (MZ) or dizygotic (DZ), were correlated with chorionicity assignment. RESULTS: 59,471 twin samples (median gestational age = 12.0 weeks at draw) were received and analyzed; 55,344 (93.1%) received zygosity assignment. SNP-cfDNA reported 16,673 (30.1%) MZ and 38,671 (69.9%) as DZ. Provider-reported chorionicity was compared to the zygosity assignment for each case. Of 6283 provider-reported MC twins, 318 (5.1%) were reported as DZ using SNP-cfDNA. CONCLUSION(S): One in 20 suspected MC twin pregnancies were reported as DZ using SNP-cfDNA. Approximately 30% of 55,344 twin pregnancies were found to be MZ, including cases where chorionicity was unknown. SNP-cfDNA zygosity assessment is a useful adjunct assessment for twin pregnancies, particularly those reported as MC or without determined chorionicity.


Asunto(s)
Ácidos Nucleicos Libres de Células , Embarazo Gemelar , Femenino , Humanos , Lactante , Embarazo , Corion , Polimorfismo de Nucleótido Simple , Embarazo Gemelar/genética , Gemelos Dicigóticos/genética , Gemelos Monocigóticos/genética
4.
J Vasc Surg ; 73(5): 1702-1714.e11, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33080324

RESUMEN

BACKGROUND: The Superficial Femoral Artery-Popliteal EvidencE Development Study Group developed contemporary objective performance goals (OPGs) for peripheral vascular interventions (PVI) for superficial femoral artery (SFA)-popliteal artery disease using the Registry Assessment of Peripheral Interventional Devices. METHODS: The Society for Vascular Surgery Vascular Quality Initiative PVI registry from January 2010 to October 2016 was used to develop OPGs based on SFA-popliteal procedures (n = 21,377) for intermittent claudication and critical limb ischemia (CLI). OPGs included 1-year rates for target lesion revascularization (TLR), major amputation, and 1 and 4-year survival rates. OPGs were calculated for the SFA and popliteal arteries and stratified by four treatments: angioplasty alone (percutaneous transluminal angioplasty [PTA]), self-expanding stenting, atherectomy, and any treatment type. Outcomes were illustrated by unadjusted Kaplan-Meier analyses. RESULTS: Cohorts included PTA (n = 7505), stenting (n = 9217), atherectomy (n = 2510) and any treatment (n = 21,377). The mean age was 69 years, 58% were male, 79% were White, and 52% had CLI. The freedom from TLR OPGs at 1 year in the SFA were 80.3% (PTA), 83.2% (stenting), 83.9% (atherectomy), and 81.9% (any treatments). The freedom from TLR OPGs at 1 year in the popliteal were 81.3% (PTA), 81.3% (stenting), 80.2% (atherectomy), and 81.1% (any treatments). The freedom from major amputation OPGs at 1 year after SFA PVI were 93.4% (PTA), 95.7% (stenting), 95.1% (atherectomy), and 94.8% (any treatments). The freedom from major amputation OPG at 1 year after popliteal PVI were 90.5% (PTA), 93.7% (stenting), 91.8% (atherectomy), and 91.8%, (any treatments). The 4-year survival OPGs after SFA PVI were 76% (PTA), 80% (stenting), 82% (atherectomy), and 79% (any treatments), and for the popliteal artery were 72% (PTA), 77% (stenting), 82% (atherectomy), and 75% (any treatment). On a multivariable analysis, which included patient-level, leg-level, and lesion-level covariates, CLI was the single independent factor associated with increased TLR, amputation, and mortality. CONCLUSIONS: The Superficial Femoral Artery-Popliteal EvidencE Development OPGs define a new, contemporary benchmark for SFA-popliteal interventions using a large subset of real-world evidence to inform more efficient peripheral device clinical trial designs to support regulatory and clinical decision-making. It is appropriate to discuss proposals intended for regulatory approval with the US Food and Drug Administration to refine the OPG to match the specific trial population. The OPGs may be updated using coordinated registry networks to assess long-term real-world device performance.


Asunto(s)
Benchmarking , Procedimientos Endovasculares/instrumentación , Arteria Femoral , Claudicación Intermitente/terapia , Isquemia/terapia , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Indicadores de Calidad de la Atención de Salud , Anciano , Anciano de 80 o más Años , Amputación Quirúrgica , Benchmarking/normas , Enfermedad Crítica , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/normas , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Mortalidad Hospitalaria , Humanos , Claudicación Intermitente/diagnóstico por imagen , Claudicación Intermitente/mortalidad , Claudicación Intermitente/fisiopatología , Isquemia/diagnóstico por imagen , Isquemia/mortalidad , Isquemia/fisiopatología , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Indicadores de Calidad de la Atención de Salud/normas , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
5.
Circulation ; 140(14): 1145-1155, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31567024

RESUMEN

BACKGROUND: A recent summary-level meta-analysis comprising randomized, controlled trials (RCTs) of femoropopliteal paclitaxel-coated balloon and stent intervention identified excess late mortality in the paclitaxel-treated patients. METHODS: We evaluated the safety of the Stellarex drug-coated balloon (DCB) for femoropopliteal artery disease with an independently performed meta-analysis of patient-level data from all patients in the Stellarex femoropopliteal clinical program. To compare mortality after DCB or uncoated percutaneous transluminal angioplasty (PTA), we aggregated data from 2 RCTs comprising 419 patients treated with DCB and 170 patients treated with PTA. In an additional analysis, data were aggregated from 6 poolable Stellarex DCB studies (2 RCTs, 3 single-arm studies, and 1 registry). All serious adverse events including deaths were adjudicated by a blinded, third-party, independent Clinical Events Committee. Kaplan-Meier estimates in the RCTs were compared with restricted mean survival time. Predictors of death were assessed with hazard ratios (HRs) and Cox proportional hazards modeling. RESULTS: Baseline characteristics were similar in the patients treated with DCB and PTA in the pooled RCT analysis, with the exception that the DCB cohort was younger (67.4±9.7 versus 69.4±9.4 years, P=0.02), smoked more frequently (86.6% versus 78.8%, P=0.02), and were less often treated for recurrent lesions (8.8% versus 14.7%, P=0.04). In the RCTs, patients treated with DCB had all-cause mortality rates that were not different from those of patients treated with PTA (Kaplan-Meier estimates 1.8±0.7% versus 1.3±0.9%, 6.5±1.2% versus 5.9±1.9%, and 9.3±1.5% versus 9.9±2.4% at 1, 2, and 3 years, respectively, P=0.86). All-cause mortality rates were similar in a 1906-patient pooled nonrandomized DCB data set (Kaplan-Meier estimates of 2.1%, 4.9%, and 7.0% at 1, 2, and 3 years, respectively). Clinical Events Committee-adjudicated causes of death were balanced between the DCB and PTA cohorts. Multivariable Cox modeling identified age (HR, 1.06; 95% CI, 1.04-1.08; P<0.001), diabetes mellitus (HR, 1.42; 95% CI, 1.01-2.00; P=0.04), congestive heart failure (HR, 1.88; 95% CI, 1.12-3.16; P=0.02), and renal insufficiency (HR, 2.00; 95% CI, 1.33-3.01; P<0.001) as predictors of mortality. Paclitaxel exposure was unrelated to mortality (HR, 1.04; 95% CI, 0.98-1.10; P=0.23). CONCLUSIONS: The mortality rates for patients treated with the DCB and uncoated PTA were indistinguishable over 3-year follow-up. Additional patient-level, adequately powered meta-analyses with larger RCT data sets will be needed to confirm the generalizability of these findings. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifiers: NCT02110524, NCT01858363, NCT01858428, NCT03421561, NCT01912937, NCT01927068, and NCT02769273.


Asunto(s)
Stents Liberadores de Fármacos/efectos adversos , Paclitaxel/química , Enfermedad Arterial Periférica/tratamiento farmacológico , Anciano , Angioplastia/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Paclitaxel/uso terapéutico , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/terapia , Modelos de Riesgos Proporcionales , Ensayos Clínicos Controlados Aleatorios como Asunto
6.
Am Heart J ; 206: 61-71, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30342296

RESUMEN

BACKGROUND: Regulatory decisions approving new coronary drug-eluting stent (DES) require mechanistic observations of angiographic late lumen loss (LLL). Patient safety and device approval times could be enhanced if angiographic follow-up data were found to be generalizable across jurisdictions and geographies. The objectives were to assess the comparability of in-segment LLL in Eastern and Western DES populations using the world's largest compilation of follow-up quantitative coronary angiography data. METHODS: Data from 4 manufacturers involving 29 DES clinical trials in Eastern and Western hemispheres were compiled. "East" and "West" cohorts were defined by trial location. Independent core laboratories quantified in-segment LLL for all studies. East and West were compared before and after adjustment for clinical and anatomic covariates known to correlate with LLL via conditioning on propensity score quintiles. An international panel of experts and regulators prospectively established a clinically meaningful difference between East and West mean in-segment LLL of ±0.40 mm. RESULTS: The data set comprised 2,047 East and 4,456 West patients. Unadjusted mean ± SD for West and East in-segment LLL (mm) was 0.25 ± 0.46 and 0.12 ± 0.42, respectively (difference 0.13 mm; 95% CI 0.11-0.16). Propensity score-adjusted in-segment LLL East and West least squares means were 0.11 and 0.26 mm, respectively (difference 0.15 mm; 95% CI 0.13-0.18). CONCLUSIONS: In the world's largest compilation of DES protocol 8- to 13-month angiographic follow-up data, clinically meaningful comparability of in-segment LLL by independent core laboratory quantitative coronary angiography in East and West cohorts was demonstrated in both unadjusted and adjusted comparisons. These findings suggest that DES LLL, once characterized, could be generalized across regulatory jurisdictions over the course of global registration efforts.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Grupos Raciales/estadística & datos numéricos , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Puntaje de Propensión , Diseño de Prótesis , Estudios Retrospectivos
7.
Am Heart J ; 182: 103-110, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27914489

RESUMEN

BACKGROUND: The contemporary evaluation of novel drug-eluting stents (DES) includes mechanistic observations that characterize postdeployment stent behavior. Quantification of late lumen loss due to neointimal hyperplasia 8-13 months after stent implantation, via quantitative coronary angiography (QCA), constitutes such an observation and is required by most regulatory authorities. Late lumen loss, as determined by QCA, has been validated as a surrogate for clinical endpoints such as target vessel revascularization. The mechanistic response to DES has not been directly compared across predominantly Asian or Western populations, whereas understanding their comparability across geographic populations could enhance global DES evaluation. OBJECTIVE: The East-West late lumen loss study is designed to demonstrate whether the residual differences in late lumen loss, as assessed by QCA, is different between Eastern and Western DES recipients from studies with protocol angiography at 8-13 months of follow-up. METHODS: Data from independent core laboratories that have characterized angiographic late lumen loss in DES clinical trials with protocol follow-up angiography will be compiled and dichotomized into Eastern and Western populations. A prospectively developed propensity score model incorporating clinical and anatomic variables affecting late lumen loss will be used to adjust comparisons of QCA measurements. CONCLUSION: Documentation of whether there are clinically meaningful differences in mechanistic response to DES implantation across genetically unique geographies could facilitate both the quality and efficiency of global device evaluation requiring invasive follow-up for novel stent designs.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Falla de Prótesis , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etnología , Reestenosis Coronaria/etiología , Stents Liberadores de Fármacos/efectos adversos , Stents Liberadores de Fármacos/normas , Análisis de Falla de Equipo/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Observacionales como Asunto , Evaluación de Procesos y Resultados en Atención de Salud/métodos , Puntaje de Propensión , Falla de Prótesis/efectos adversos , Falla de Prótesis/etiología , Grupos Raciales/estadística & datos numéricos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos
8.
N Engl J Med ; 364(3): 226-35, 2011 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-21247313

RESUMEN

BACKGROUND: Atherosclerotic plaques that lead to acute coronary syndromes often occur at sites of angiographically mild coronary-artery stenosis. Lesion-related risk factors for such events are poorly understood. METHODS: In a prospective study, 697 patients with acute coronary syndromes underwent three-vessel coronary angiography and gray-scale and radiofrequency intravascular ultrasonographic imaging after percutaneous coronary intervention. Subsequent major adverse cardiovascular events (death from cardiac causes, cardiac arrest, myocardial infarction, or rehospitalization due to unstable or progressive angina) were adjudicated to be related to either originally treated (culprit) lesions or untreated (nonculprit) lesions. The median follow-up period was 3.4 years. RESULTS: The 3-year cumulative rate of major adverse cardiovascular events was 20.4%. Events were adjudicated to be related to culprit lesions in 12.9% of patients and to nonculprit lesions in 11.6%. Most nonculprit lesions responsible for follow-up events were angiographically mild at baseline (mean [±SD] diameter stenosis, 32.3±20.6%). However, on multivariate analysis, nonculprit lesions associated with recurrent events were more likely than those not associated with recurrent events to be characterized by a plaque burden of 70% or greater (hazard ratio, 5.03; 95% confidence interval [CI], 2.51 to 10.11; P<0.001) or a minimal luminal area of 4.0 mm(2) or less (hazard ratio, 3.21; 95% CI, 1.61 to 6.42; P=0.001) or to be classified on the basis of radiofrequency intravascular ultrasonography as thin-cap fibroatheromas (hazard ratio, 3.35; 95% CI, 1.77 to 6.36; P<0.001). CONCLUSIONS: In patients who presented with an acute coronary syndrome and underwent percutaneous coronary intervention, major adverse cardiovascular events occurring during follow-up were equally attributable to recurrence at the site of culprit lesions and to nonculprit lesions. Although nonculprit lesions that were responsible for unanticipated events were frequently angiographically mild, most were thin-cap fibroatheromas or were characterized by a large plaque burden, a small luminal area, or some combination of these characteristics, as determined by gray-scale and radiofrequency intravascular ultrasonography. (Funded by Abbott Vascular and Volcano; ClinicalTrials.gov number, NCT00180466.).


Asunto(s)
Síndrome Coronario Agudo/etiología , Enfermedad de la Arteria Coronaria/complicaciones , Vasos Coronarios/patología , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Anciano , Angioplastia Coronaria con Balón , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Progresión de la Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Readmisión del Paciente , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Recurrencia , Factores de Riesgo , Ultrasonografía Intervencional/métodos
9.
Artículo en Inglés | MEDLINE | ID: mdl-38897847

RESUMEN

In 2020, the NIH and FDA issued guidance documents that laid the foundation for human subject research during an unprecedented pandemic. To bridge these general considerations to actual applications in cardiovascular interventional device trials, the PAndemic Impact on INTErventional device ReSearch (PAIINTERS) Working Group was formed in early 2021 under the Predictable And Sustainable Implementation Of National CardioVascular Registries (PASSION CV Registries). The PAIINTER's Part I report, published by Rymer et al. [5], provided a comprehensive overview of the operational impact on interventional studies during the first year of the Pandemic. PAIINTERS Part II focused on potential statistical issues related to bias, variability, missing data, and study power when interventional studies may start and end in different pandemic phases. Importantly, the paper also offers practical mitigation strategies to adjust or minimize the impact for both SATs and RCTs, providing a valuable resource for researchers and professionals involved in cardiovascular clinical trials.

10.
Am Heart J ; 165(3): 344-53.e1, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23453103

RESUMEN

Percutaneous coronary intervention (PCI) is an integral part of the treatment of coronary artery disease. The most common complication of PCI, bleeding, typically occurs at the vascular access site and is associated with short-term and long-term morbidity and mortality. Periprocedural bleeding also represents the primary safety concern of concomitant antithrombotic therapies essential for PCI success. Use of radial access for PCI reduces procedural bleeding and hence may change the risk profile and net clinical benefit of these drugs. This new drug-device safety interaction creates opportunities to advance the safe and effective use of antithrombotic agents during PCI. In June 2010 and March 2011, leaders from government, academia, professional societies, device manufacturing, and pharmaceutical industries convened for 2 think tank meetings. Titled TREAT I and II, these forums examined approaches to improve the overall safety of PCI by optimizing strategies for antithrombotic drug use and radial artery access. This article summarizes the content and proceedings of these sessions.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Fibrinolíticos/administración & dosificación , Intervención Coronaria Percutánea/métodos , Hemorragia Posoperatoria/etiología , Arteria Radial/cirugía , Fibrinolíticos/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos
11.
Transplant Proc ; 54(6): 1446-1454, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35618524

RESUMEN

BACKGROUND: Kidney transplant (KT) recipients are at high risk for developing severe COVID-19. Lowering immunosuppression levels in KT recipients with COVID-19 encourages native immune responses but can raise the risk of rejection. Donor-derived cell-free DNA (dd-cfDNA), reported as a fraction of total cfDNA, is a proven biomarker for KT rejection. Total cfDNA levels are elevated in patients with COVID-19, which may depress dd-cfDNA fractions, potentially leading to missed rejections. METHODS: A retrospective analysis of 29 KT recipients hospitalized with COVID-19 between April and November 2020 examined total and dd-cfDNA levels. Blood samples were collected after onset of COVID-19, with follow-up samples collected from a subset of patients, when infection had likely subsided. RESULTS: After COVID-19 diagnosis, the median total cfDNA level was elevated (7.9 multiples of median [MoM]). A significant decrease in total cfDNA levels was observed between the first and second time points (6.2 MoM, 1.0 MoM; P <001). A significant positive association was identified between total cfDNA levels and COVID-19 severity (P = .02; R2 = .19). Two patients with biopsy-proven acute cellular rejection had dd-cfDNA fractions below the 1% cutoff for rejection (0.20% and 0.78%), with elevated total cfDNA levels of 7.9 MoM and 41.8 MoM, respectively. CONCLUSIONS: In this preliminary study, total cfDNA levels were elevated in KT patients with COVID-19, subsiding after resolution of infection. High total cfDNA levels may confound dd-cfDNA results, leading to failure to identify rejection. Considering total cfDNA levels is important in interpretation of dd-cfDNA tests for assessment of rejection in KT patients with COVID-19 or other infection.


Asunto(s)
COVID-19 , Ácidos Nucleicos Libres de Células , Trasplante de Riñón , Biomarcadores , Prueba de COVID-19 , Rechazo de Injerto , Humanos , Trasplante de Riñón/efectos adversos , Estudios Retrospectivos , SARS-CoV-2 , Donantes de Tejidos
12.
J Am Heart Assoc ; 10(4): e018149, 2021 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-33554613

RESUMEN

BACKGROUND The long-term safety of paclitaxel-coated devices (PCDs; drug-coated balloon or drug-eluting stent) for peripheral endovascular intervention is uncertain. We used data from the Veterans Health Administration to evaluate the association between PCDs, long-term mortality, and cause of death. METHODS AND RESULTS Using the Veterans Administration Corporate Data Warehouse in conjunction with International Classification of Diseases, Tenth Revision (ICD-10) Procedure Coding System, Current Procedural Terminology, and Healthcare Common Procedure Coding System codes, we identified patients with peripheral artery disease treated within the Veterans Administration for femoropopliteal artery revascularization between October 1, 2015, and June 30, 2019. An adjusted Cox regression, using stabilized inverse probability-weighted estimates, was used to evaluate the association between PCDs and long-term survival. Cause of death data were obtained using the National Death Index. In total, 10 505 patients underwent femoropopliteal peripheral endovascular intervention; 2265 (21.6%) with a PCD and 8240 (78.4%) with a non-PCD (percutaneous angioplasty balloon and/or bare metal stent). Survival rates at 2 years (77.4% versus 79.7%) and 3 years (70.7% versus 71.8%) were similar between PCD and non-PCD groups, respectively. The adjusted hazard for all-cause mortality for patients treated with a PCD versus non-PCD was 1.06 (95% CI, 0.95-1.18, P=0.3013). Among patients who died between October 1, 2015, and December 31, 2017, the cause of death according to treatment group, PCD versus non-PCD, was similar. CONCLUSIONS Among patients undergoing femoropopliteal peripheral endovascular intervention within the Veterans Administration Health Administration, there was no increased risk of long-term, all-cause mortality associated with PCD use. Cause-specific mortality rates were similar between treatment groups.


Asunto(s)
Angioplastia de Balón/métodos , Stents Liberadores de Fármacos , Arteria Femoral/cirugía , Paclitaxel/farmacología , Arteria Poplítea/cirugía , Salud de los Veteranos , Veteranos , Anciano , Antineoplásicos Fitogénicos/farmacología , Causas de Muerte/tendencias , Materiales Biocompatibles Revestidos , Femenino , Estudios de Seguimiento , Humanos , Extremidad Inferior , Masculino , Enfermedad Arterial Periférica/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos , United States Department of Veterans Affairs/estadística & datos numéricos
13.
Circulation ; 119(5): 680-6, 2009 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-19171853

RESUMEN

BACKGROUND: In the prospective randomized Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions (SPIRIT) III trial, an everolimus-eluting stent (EES) compared with a widely used paclitaxel-eluting stent (PES) resulted in a statistically significant reduction in angiographic in-segment late loss at 8 months and noninferior rates of target vessel failure (cardiac death, myocardial infarction, or target vessel revascularization) at 1 year. The safety and efficacy of EES after 1 year have not been reported. METHODS AND RESULTS: A total of 1002 patients with up to 2 de novo native coronary artery lesions (reference vessel diameter, 2.5 to 3.75 mm; lesion length < or =28 mm) were randomized 2:1 to EES versus PES. Antiplatelet therapy consisted of aspirin indefinitely and a thienopyridine for > or =6 months. Between 1 and 2 years, patients treated with EES compared with PES tended to have fewer episodes of protocol-defined stent thrombosis (0.2% versus 1.0%; P=0.10) and myocardial infarctions (0.5% versus 1.7%; P=0.12), with similar rates of cardiac death (0.3% versus 0.3%; P=1.0) and target vessel revascularization (2.9% versus 3.0%; P=1.0). As a result, at the completion of the 2-year follow-up, treatment with EES compared with PES resulted in a significant 32% reduction in target vessel failure (10.7% versus 15.4%; hazard ratio, 0.68; 95% confidence interval, 0.48 to 0.98; P=0.04) and a 45% reduction in major adverse cardiac events (cardiac death, myocardial infarction, or target lesion revascularization; 7.3% versus 12.8%; hazard ratio, 0.55; 95% confidence interval, 0.36 to 0.83; P=0.004). Among the 360 patients who discontinued clopidogrel or ticlopidine after 6 months, stent thrombosis subsequently developed in 0.4% of EES patients versus 2.6% of PES patients (P=0.10). CONCLUSIONS: Patients treated with EES rather than PES experienced significantly improved event-free survival at a 2-year follow-up in the SPIRIT III trial, with continued divergence of the hazard curves for target vessel failure and major adverse cardiac events between 1 and 2 years evident. The encouraging trends toward fewer stent thrombosis episodes after 6 months in EES-treated patients who discontinued a thienopyridine and after 1 year in all patients treated with EES rather than PES deserve further study.


Asunto(s)
Angioplastia , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Sirolimus/análogos & derivados , Anciano , Antineoplásicos Fitogénicos/administración & dosificación , Antineoplásicos Fitogénicos/efectos adversos , Enfermedad de la Arteria Coronaria/epidemiología , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/prevención & control , Trombosis Coronaria/epidemiología , Trombosis Coronaria/prevención & control , Supervivencia sin Enfermedad , Stents Liberadores de Fármacos/efectos adversos , Stents Liberadores de Fármacos/estadística & datos numéricos , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/administración & dosificación , Inmunosupresores/efectos adversos , Incidencia , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Estudios Prospectivos , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Resultado del Tratamiento
14.
Am Heart J ; 158(4): 520-526.e2, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19781409

RESUMEN

BACKGROUND: In the 300-patient SPIRIT II and 1002-patient SPIRIT III randomized trials, the everolimus-eluting stent (EES) compared to the paclitaxel-eluting stent (PES) resulted in reduced angiographic late loss (a primary end point in both trials), noninferior rates of 9-month target vessel failure (a primary end point in SPIRIT III), and reduced rates of target lesion revascularization and major adverse cardiac events (secondary end points). However, neither trial was powered for superiority for clinical end points, and the routine performance of angiographic follow-up may have artificially exaggerated the absolute benefits of EES. The relative efficacy of these 2 stents in patients with diabetes mellitus also remains controversial. We therefore designed a large-scale randomized trial without angiographic follow-up to further assess the differences between these 2 stent platforms. STUDY DESIGN: SPIRIT IV is an ongoing prospective, active-controlled, single-blinded, multicenter clinical trial in which 3690 patients with native coronary artery disease have been randomized 2:1 to EES versus PES. Patients with up to 3 de novo native coronary artery lesions (maximum 2 lesions per epicardial vessel) with length or=2.5 to

Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Revascularización Miocárdica/métodos , Paclitaxel/farmacología , Sirolimus/análogos & derivados , Antineoplásicos Fitogénicos/farmacología , Enfermedad de la Arteria Coronaria/fisiopatología , Electrocardiografía , Everolimus , Estudios de Seguimiento , Humanos , Inmunosupresores/farmacología , Estudios Prospectivos , Método Simple Ciego , Sirolimus/farmacología , Factores de Tiempo , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 74(5): 719-27, 2009 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-19530147

RESUMEN

OBJECTIVES: We evaluated the role of gender on clinical and angiographic results of the everolimus-eluting stent in the SPIRIT III trial. BACKGROUND: The SPIRIT III trial demonstrated superior efficacy of the XIENCE V everolimus-eluting stent compared with the TAXUS paclitaxel-eluting stent. Whether these results are applicable to women is unknown. METHODS: A total of 1,002 patients with coronary artery lesions of 28 mm or less long in 2.5-3.75 mm diameter vessels were prospectively randomized to receive percutaneous coronary intervention with either XIENCE V stent or TAXUS stent placement. Post hoc gender subset analysis was performed. RESULTS: A total of 669 patients (200 women) received the XIENCE V stent, and 332 patients (114 women) were assigned to the TAXUS stent. Women were older and had more hypertension and diabetes than men. At 1 year, rates of MACE (11.1% vs. 5.7%, P = 0.004), TVF (13.7% vs. 7.5%, P = 0.003), TVR (10.8% vs. 4.6%, P = 0.0007), and TLR (7.2% vs. 2.7%, P = 0.002) were higher in women compared with men. The difference in 1 year MACE and TVF rates between men and women remained after adjusting for baseline covariates. Although the angiographic characteristics at baseline were similar among the female cohort, women assigned to XIENCE V had lower in-stent late loss (0.19 vs. 0.42 mm, P = 0.01) compared with women treated with the TAXUS stent. Although 30-day clinical outcomes were similar for women treated with XIENCE V and TAXUS stents, at 1 year, women with XIENCE V stents had significantly lower MACE (8.2% vs. 16.1 %, P = 0.04) and TVR (3.1% vs. 8.9%, P = 0.03) compared with those treated with TAXUS stents. Stent thrombosis rates were similar between women receiving either XIENCE V or TAXUS stents. CONCLUSIONS: Women in the SPIRIT III trial had inherently higher MACE and TVF rates than men. However, the angiographic and clinical benefits of using XIENCE V stents are generalizable to women.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Enfermedades Cardiovasculares/etiología , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Sirolimus/análogos & derivados , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Everolimus , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Lineales , Modelos Logísticos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Método Simple Ciego , Sirolimus/administración & dosificación , Trombosis/diagnóstico por imagen , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento , Salud de la Mujer
16.
JACC Cardiovasc Interv ; 12(24): 2515-2524, 2019 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-31575518

RESUMEN

OBJECTIVES: The aim of this study was to assess safety outcomes of femoropopliteal drug-coated balloon (DCB) angioplasty using patient-level data from the Lutonix clinical program. BACKGROUND: A recent systematic review and meta-analysis of heterogenous trials and summary-level data identified increased long-term mortality in patients treated with paclitaxel-coated balloons and stents. METHODS: We evaluated DCB angioplasty (n = 1,093) and uncoated balloon angioplasty (percutaneous transluminal angioplasty [PTA]) (n = 250) outcomes in LEVANT 1 (The Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis), LEVANT 2 (Moxy Drug Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Femoropopliteal Arteries), and the LEVANT Japan Clinical Trial. Hazard ratios (HRs) were calculated with Cox proportional hazards modeling. RESULTS: There were no significant differences in mortality rates between DCB angioplasty and PTA. The 5-year HR was 1.01 (95% confidence interval [CI]: 0.68 to 1.52) in the aggregated LEVANT trials. The 2-year HR after DCB angioplasty was 0.99 (95% CI: 0.25 to 3.95) in LEVANT 1, 1.40 (95% CI: 0.62 to 3.14) in LEVANT 2, and 0.32 (95% CI: 0.05 to 1.92) in the LEVANT Japan Clinical Trial. The 5-year HR was 1.60 (95% CI: 0.94 to 2.72) in LEVANT 2. Adverse events and causes of death were balanced, without clustering between DCB angioplasty and PTA. Patients who underwent paclitaxel or nonpaclitaxel reinterventions had higher survival rates than those who did not undergo reinterventions. Baseline covariates predicting mortality included, among others, age (HR: 1.03 per year; p < 0.0001), prior treatment of target lesion (HR: 1.67; p = 0.022), arrhythmia (HR: 1.65; p = 0.031), and diabetes (HR: 1.18; p = 0.047), without differences between the 2 arms. No dose-response relationship was identified when adjusted for key predictors of mortality. CONCLUSIONS: Analyses of patient-level data identified no mortality differences between DCB angioplasty and PTA. Furthermore, the lack of dose-response relationships or clustering of causes of death argues against a causal relationship between paclitaxel and mortality. (LEVANT 1, The Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis [LEVANT 1], NCT00930813; Moxy Drug Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Femoropopliteal Arteries [LEVANT 2], NCT01412541; LEVANT 2 Continued Access Registry, NCT01628159; LEVANT Japan Clinical Trial, NCT01816412).


Asunto(s)
Angioplastia de Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Arteria Femoral , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Causas de Muerte , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
17.
JACC Cardiovasc Interv ; 11(4): 384-392, 2018 02 26.
Artículo en Inglés | MEDLINE | ID: mdl-29397361

RESUMEN

OBJECTIVES: The authors sought to determine baseline neurocognition before transcatheter aortic valve replacement (TAVR) and its correlations with pre-TAVR brain imaging. BACKGROUND: TAVR studies have not shown a correlation between diffusion-weighted image changes and neurocognition. The authors wanted to determine the extent to which there was already impairment at baseline that correlated with cerebrovascular disease. METHODS: SENTINEL (Cerebral Protection in Transcatheter Aortic Valve Replacement) trial patients had cognitive assessments of attention, processing speed, executive function, and verbal and visual memory. Z-scores were based on normative means and SDs, combined into a primary composite z-score. Brain magnetic resonance images were obtained pre-TAVR on 3-T scanners with a T2 fluid-attenuated inversion recovery (FLAIR) sequence. Scores ≤-1.5 SD below the normative mean (7th percentile) were considered impairment. Paired t tests compared within-subject scores, and chi-square goodness-of-fit compared the percentage of subjects below -1.5 SD. Correlation and regression analyses assessed the relationship between neurocognitive z-scores and T2 lesion volume. RESULTS: Among 234 patients tested, the mean composite z-score was -0.65 SD below the normative mean. Domain scores ranged from -0.15 SD for attention to -1.32 SD for executive function. On the basis of the ≥1.5 SD normative reference, there were significantly greater percentages of impaired scores in the composite z-score (13.2%; p = 0.019), executive function (41.9%; p < 0.001), verbal memory (p < 0.001), and visual memory (p < 0.001). The regression model between FLAIR lesion volume and baseline cognition showed statistically significant negative correlations. CONCLUSIONS: There was a significant proportion of aortic stenosis patients with impaired cognition before TAVR, with a relationship between baseline cognitive function and lesion burden likely attributable to longstanding cerebrovascular disease. These findings underscore the importance of pre-interventional testing and magnetic resonance imaging in any research investigating post-surgical cognitive outcomes in patients with cardiovascular disease.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Trastornos Cerebrovasculares/complicaciones , Trastornos del Conocimiento/complicaciones , Cognición , Reemplazo de la Válvula Aórtica Transcatéter , Factores de Edad , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Atención , Trastornos Cerebrovasculares/diagnóstico , Trastornos Cerebrovasculares/psicología , Trastornos del Conocimiento/diagnóstico , Trastornos del Conocimiento/psicología , Función Ejecutiva , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Memoria , Pruebas Neuropsicológicas , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
18.
J Am Heart Assoc ; 6(6)2017 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-28600401

RESUMEN

BACKGROUND: Arterial Remodeling Technologies bioresorbable scaffold (ART-BRS), composed of l- and d-lactyl units without drug, has shown its safety in a porcine coronary model at 6 months. However, long-term performance remains unknown. The aim of this study was to evaluate the ART-BRS compared to a bare metal stent (BMS) in a healthy porcine coronary model for up to 3 years. METHODS AND RESULTS: Eighty-two ART-BRS and 66 BMS were implanted in 64 Yucatan swine, and animals were euthanatized at intervals of 1, 3, 6, 9, 12, 18, 24, and 36 months to determine the vascular response using quantitative coronary angiography, optical coherence tomography, light and scanning electron microscopy, and molecular weight analysis. Lumen enlargement was observed in ART-BRS as early as 3 months, which progressively increased up to 18 months, whereas BMS showed no significant difference over time. Percentage area stenosis by optical coherence tomography was greater in ART-BRS than in BMS at 1 and 3 months, but this relationship reversed beyond 3 months. Inflammation peaked at 6 months and thereafter continued to decrease up to 36 months. Complete re-endothelialization was observed at 1 month following implantation in both ART-BRS and BMS. Scaffold dismantling started at 3 months, which allowed early vessel enlargement, and bioresorption was complete by 24 months. CONCLUSIONS: ART-BRS has the unique quality of early programmed dismantling accompanied by vessel lumen enlargement with mild to moderate inflammation. The main distinguishing feature of the ART-BRS from other scaffolds made from poly-l-lactic acid may result in early and long-term vascular restoration.


Asunto(s)
Implantes Absorbibles , Vasos Coronarios/cirugía , Metales , Poliésteres , Stents , Andamios del Tejido , Remodelación Vascular , Animales , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/cirugía , Vasos Coronarios/ultraestructura , Modelos Animales de Enfermedad , Estudios de Seguimiento , Microscopía Electrónica de Rastreo , Revascularización Miocárdica , Diseño de Prótesis , Porcinos , Factores de Tiempo , Tomografía de Coherencia Óptica
19.
J Am Coll Cardiol ; 69(4): 367-377, 2017 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-27815101

RESUMEN

BACKGROUND: Neurological complications after transcatheter aortic valve replacement (TAVR) may be reduced with transcatheter cerebral embolic protection (TCEP). OBJECTIVES: This study evaluated the safety and efficacy of TCEP during TAVR. METHODS: Nineteen centers randomized 363 patients undergoing TAVR to a safety arm (n = 123), device imaging (n = 121), and control imaging (n = 119). The primary safety endpoint consisted of major adverse cardiac and cerebrovascular events (MACCE) at 30 days, and the primary efficacy endpoint was reduction in new lesion volume in protected brain territories on magnetic resonance imaging scans at 2 to 7 days. Patients underwent neurocognitive assessments, and the debris captured was analyzed. RESULTS: The rate of MACCE (7.3%) was noninferior to the performance goal (18.3%, pnoninferior < 0.001) and not statistically different from that of the control group (9.9%; p = 0.41). New lesion volume was 178.0 mm3 in control subjects and 102.8 mm3 in the device arm (p = 0.33). A post hoc multivariable analysis identified pre-existing lesion volume and valve type as predictors of new lesion volume. Strokes at 30 days were 9.1% in control subjects and 5.6% in patients with devices (p = 0.25) Neurocognitive function was similar in control subjects and patients with devices, but there was a correlation between lesion volume and neurocognitive decline (p = 0.0022). Debris found within filters in 99% of patients included thrombus, calcification, valve tissue, artery wall, and foreign material. CONCLUSIONS: TCEP was safe, captured embolic debris in 99% of patients, and did not change neurocognitive function. Reduction in new lesion volume on magnetic resonance scans was not statistically significant. (Cerebral Protection in Transcatheter Aortic Valve Replacement [SENTINEL]; NCT02214277).


Asunto(s)
Válvula Aórtica/cirugía , Embolia Intracraneal/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Cognición , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Seguridad , Resultado del Tratamiento
20.
Eur Heart J Qual Care Clin Outcomes ; 2(2): 108-116, 2016 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29474621

RESUMEN

AIMS: In the ABSORB II trial, comparing Absorb™ bioresorbable vascular scaffold with metallic XIENCE™ everolimus-eluting stent (EES), a difference was found in site-reported new or worsening angina using adverse event (AE) reporting. However, the clinical relevance of this site-reported angina is unclear. The aim of the present study was therefore to investigate the clinical relevance of site-reported angina by evaluating its relation with cardiac endpoints, cardiovascular resource utilization (including diagnostics and treatment), positive exercise stress tolerance tests (ETTs), and Seattle Angina Questionnaire (SAQ). METHODS AND RESULTS: Site-reported new or worsening angina was captured on cardiac AE forms. There was a wide variation in the total number of days with site-reported angina (overall interquartile range 35-279 days). Patients with site-reported angina showed higher rates of cardiovascular events [including the patient-oriented composite endpoint of all deaths, all myocardial infarctions (MI), or all revascularizations (21.1 vs. 4.2%, P < 0.0001), all MIs (2.3 vs. 0%, P = 0.03), and all revascularizations (21.1 vs. 0.7%, P < 0.0001)], cardiovascular resource utilization (including stress tests, anti-anginal medication, diagnostic angiographies, and hospitalization), and positive ETTs (51.9 vs. 14.9%, P < 0.001), compared with those without site-reported angina. Furthermore, an event-based analysis of the SAQ showed that patients with ongoing angina within the recall period of 4 weeks prior to the SAQ assessment have clinically and statistically significant decrements of >14 points in SAQ scores compared with those with no reported angina. CONCLUSIONS: We showed that the site-reported angina through AE reporting may be clinically relevant because of their relation with cardiovascular events (mostly repeat revascularizations), cardiovascular resource utilization, ETT, and SAQ. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT01425281; Unique identifier: NCT01425281.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda