J Appl Clin Med Phys ; 21(8): 278-288, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32441884

RESUMEN

PURPOSE: The PTW microDiamond has an enhanced spatial resolution when operated in an edge-on orientation but is not typically utilized in this orientation due to the specifications of the IAEA TRS-483 code of practice for small field dosimetry. In this work the suitability of an edge-on orientation and advantages over the recommended face-on orientation will be presented. METHODS: The PTW microDiamond in both orientations was compared on a Varian TrueBeam linac for: machine output factor (OF), percentage depth dose (PDD), and beam profile measurements from 10 × 10 cm2 to a 0.5 × 0.5 cm2 field size for 6X and 6FFF beam energies in a water tank. A quantification of the stem effect was performed in edge-on orientation along with tissue to phantom ratio (TPR) measurements. An extensive angular dependence study for the two orientations was also undertaken within two custom PMMA plastic cylindrical phantoms. RESULTS: The OF of the PTW microDiamond in both orientations agrees within 1% down to the 2 × 2 cm2 field size. The edge-on orientation overresponds in the build-up region but provides improved penumbra and has a maximum observed stem effect of 1%. In the edge-on orientation there is an angular independent response with a maximum of 2% variation down to a 2 × 2 cm2 field. The PTW microDiamond in edge-on orientation for TPR measurements agreed to the CC01 ionization chamber within 1% for all field sizes. CONCLUSIONS: The microDiamond was shown to be suitable for small field dosimetry when operated in edge-on orientation. When edge-on, a significantly reduced angular dependence is observed with no significant stem effect, making it a more versatile QA instrument for rotational delivery techniques.


Asunto(s)
Aceleradores de Partículas , Radiometría , Humanos , Fantasmas de Imagen , Fotones , Agua
2.
J Appl Clin Med Phys ; 19(1): 174-183, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29265684

RESUMEN

Four methodologies were evaluated for quantifying kilovoltage cone-beam computed tomography (CBCT) dose: the Cone-Beam Dose Index (CBDI), IAEA Report 5 recommended methodology (IAEA), the AAPM Task Group 111 methodology (TG111), and the current dose metric; the Computed Tomography Dose Index (CTDI) on two commercial Varian cone-beam CT imaging systems; the Clinac iX On-Board Imager (OBI); and the TrueBeam X-ray Imaging system (XI). The TG111 methodology measured the highest overall dose (21.199 ± 0.035 mGy OBI and 22.420 ± 0.002 XI for pelvis imaging) due to the full scatter of the TG111 phantom and was within 5% of CTDI measurements taken using a full scatter TG111 phantom and 30-cm film strips. CBDI measured the second highest overall dose, within 10% of the TG111, with IAEA measuring the third highest dose. For head CBCT protocols, CBDI measured the highest dose, followed by IAEA. The CTDI method measured lowest across all scan modes highlighting its limitations for CBCT dosimetry. The XI imaging system delivered lower doses for head and thorax scan modes and similar doses to the OBI system for pelvis scan modes due to additional beam hardening filtration in the XI system. The TG111 method measured the highest dose in the center of a CBCT scan during image guidance procedures; however, CBDI provided a good approximation to TG111 with existing CTDI equipment and may be more applicable clinically.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Neoplasias/radioterapia , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Cabeza/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Pelvis/diagnóstico por imagen , Radiografía Torácica , Dosificación Radioterapéutica
3.
J Med Imaging Radiat Oncol ; 67(7): 796-805, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37454334

RESUMEN

INTRODUCTION: Guidelines for clinical target volume (CTV) to planning target volume (PTV) margins in post-prostatectomy radiation therapy (PPRT) are varied and often not clearly defined. Assessment of appropriateness of margins is commonly measured on prevalence of geographic miss. METHODS: Cone-beam CT (CBCT) images (n = 92) for 10 PPRT patients were incorporated to provide on-treatment information on the appropriateness of six different CTV expansion margins in terms of geographic miss and change in dose-volume statistics for CTV, rectum and bladder. Uniform margins included 10 mm, 5 mm, 10 mm + 5 mm posteriorly and 5 mm + 3 mm posteriorly. In addition, two anisotropic margins were evaluated by separating the superior and inferior portions of the CTV before expansion. Treatment plans were created for each PTV retrospectively. RESULTS: The frequency of geographic miss was the smallest for the large uniform expansions but resulted in the highest organ-at-risk (OAR) doses. Geographic miss in the smaller uniform and anisotropic PTVs was more prevalent but commonly to a small volume < 1% of CTV. When averaged over all CBCT fractions, V95% dose for all CTV margins remained > 99%. The anisotropic expansions generated smaller irradiated target volumes and consequently saw up to 7.3% reduction in bladder dose when compared with similar uniform expansion margins. CONCLUSION: Supplementing the incidence of geographic miss with dosimetric information on target coverage and OAR doses provides more informed assessment of the appropriateness of different CTV expansion margins. Our study extends the evaluation of anisotropic margins for PPRT.


Asunto(s)
Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada , Masculino , Humanos , Estudios Retrospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen/métodos , Vejiga Urinaria/diagnóstico por imagen , Prostatectomía , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
4.
Front Oncol ; 13: 1333098, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38375205

RESUMEN

Introduction: There is no consensus as to what specifically constitutes head and neck cancer radiotherapy quality assurance (HNC RT QA). The aims of this study are to (1) describe the RT QA processes used in the TROG 12.01 study, (2) review the RT QA processes undertaken for all patients with loco-regional failure (LRF), and (3) provide prospective data to propose a consensus statement regarding the minimal components and optimal timing of HNC RT QA. Materials and methods: All patients undergoing RT QA in the original TROG 12.01 study were included in this substudy. All participating sites completed IMRT credentialling and a clinical benchmark case. Real-time (pre-treatment) RT QA was performed for the first patient of each treating radiation oncologist, and for one in five of subsequent patients. Protocol violations were deemed major if they related to contour and/or dose of gross tumour volume (GTV), high dose planning target volume (PTVhd), or critical organs of risk (spinal cord, mandible, and brachial plexus). Results: Thirty HNROs from 15 institutions accrued 182 patients. There were 28 clinical benchmark cases, 27 pre-treatment RT QA cases, and 38 post-treatment cases. Comprehensive RT QA was performed in 65/182 (36%) treated patients. Major protocol violations were found in 5/28 benchmark cases, 5/27 pre-treatment cases, and 6/38 post-treatment cases. An independent review of all nine LRF cases showed major protocol violations in four of nine cases. Conclusion: Only pre-treatment RT QA can improve patient outcomes. The minimal components of RT QA in HNC are GTVs, PTVhd, and critical organs at risk. What constitutes major dosimetric violations needs to be harmonised.

5.
Int J Prison Health ; 2021 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-33683835

RESUMEN

PURPOSE: The outbreak of the severe acute respiratory syndrome coronavirus 2 virus and subsequent COVID-19 illness has had a major impact on all levels of society internationally. The extent of the impact of COVID-19 on prison staff and prisoners in England and Wales is unknown. Testing for COVID-19 both asymptomatic and symptomatic, as well as for antibodies, to date, has been minimal. The purpose of this paper is to explore the widespread testing of COVID-19 in prisons poses philosophical and ethical questions around trust, efficacy and ethicacy. DESIGN/METHODOLOGY/APPROACH: This paper is both descriptive, providing an overview of the widespread testing of COVID-19 in prisoners in England and Wales, and conceptual in that it discusses and argues the issues associated with large-scale testing. This paper provides a discussion, using comparative studies, of the issues associated with large-scale testing of prisoners across the prison estate in England and Wales (120 prisons). The issues identified in this paper are contextualised through the lens of COVID-19, but they are equally transferrable to epidemiological studies of any pandemic. Given the prevalence of COVID-19 globally and the lack of information about its spread in prisons, at the time of writing this paper, there is a programme of asymptomatic testing of prisoners. However, there remains a paucity of data on the spread of COVID-19 in prisons because of the progress with the ongoing testing programme. FINDINGS: The authors argue that the widespread testing of prisoners requires careful consideration of the details regarding who is included in testing, how consent is gained and how tests are administered. This paper outlines and argues the importance of considering the complex nuance of power relationships within the prison system, among prisoner officers, medical staff and prisoners and the detrimental consequences. PRACTICAL IMPLICATIONS: The widespread testing of COVID-19 presents ethical and practical challenges. Careful planning is required when considering the ethics of who should be included in COVID-19 testing, how consent will be gained, who and how tests will be administered and very practical challenges around the recording and assigning of COVID-19 test kits inside the prison. The current system for the general population requires scanning of barcodes and registration using a mobile number; these facilities are not permitted inside a prison. ORIGINALITY/VALUE: This paper looks at the issues associated with mass testing of prisoners for COVID-19. According to the authors' knowledge, there has not been any research that looks at the issues of testing either in the UK or internationally. The literature available details countries' responses to the pandemic rather and scientific papers on the development of vaccines. Therefore, this paper is an original review of some of the practicalities that need to be addressed to ensure that testing can be as successful as possible.

6.
Phys Med ; 80: 42-46, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33096418

RESUMEN

PURPOSE: To evaluate eXaSkin, a novel high-density bolus alternative to commercial tissue-equivalent Superflab, for 6MV photon-beam radiotherapy. MATERIALS AND METHODS: We delivered a 10 × 10 cm2 open field at 90° and head-and-neck clinical plan, generated with the volumetric modulated arc therapy (VMAT) technique, to an anthropomorphic phantom in three scenarios: with no bolus on the phantom's surface, with Superflab, and with eXaSkin. In each scenario, we measured dose to a central planning target volume (PTV) in the nasopharynx region with an ionization chamber, and we measured dose to the skin, at three different positions within the vicinity of a neck lymph node PTV, with MOSkin™, a semiconductor dosimeter. Measurements were compared against calculations with the treatment planning system (TPS). RESULTS: For the static field, MOSkin results underneath the eXaSkin were in agreement with calculations to within 1.22%; for VMAT, to within 5.68%. Underneath Superflab, those values were 3.36% and 11.66%. The inferior agreement can be explained by suboptimal adherence of Superflab to the phantom's surface as well as difficulties in accurately reproducing its placement between imaging and treatment session. In all scenarios, dose measured at the central target agreed to within 1% with calculations. CONCLUSIONS: eXaSkin was shown to have superior adaptation to the phantom's surface, producing minimal air gaps between the skin surface and bolus, allowing for accurate positioning and reproducibility of set-up conditions. eXaSkin with its high density material provides sufficient build-up to achieve full skin dose with less material thickness than Superflab.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Rayos X
7.
Med Phys ; 47(8): 3658-3668, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32395821

RESUMEN

PURPOSE: The development of novel detectors for dosimetry in advanced radiotherapy modalities requires materials that have a water equivalent response to ionizing radiation such that characterization of radiation beams can be performed without the need for complex calibration procedures and correction factors. Organic semiconductors are potentially an ideal technology in fabricating devices for dosimetry due to tissue equivalence, mechanical flexibility, and relatively cheap manufacturing cost. The response of a commercial organic photodetector (OPD), coupled to a plastic scintillator, to ionizing radiation from a linear accelerator and orthovoltage x-ray tube has been characterized to assess its potential as a dosimeter for radiotherapy. The radiation hardness of the OPD has also been investigated to demonstrate its longevity for such applications. METHODS: Radiation hardness measurements were achieved by observing the response of the OPD to the visible spectrum and 70 keV x rays after pre-exposure to 40 kGy of ionizing radiation. The response of a preirradiated OPD to 6-MV photons from a linear accelerator in reference conditions was compared to a nonirradiated OPD with respect to direct and indirect (RP400 plastic scintillator) detection mechanisms. Dose rate dependence of the OPD was measured by varying the surface-to-source distance between 90 and 300 cm. Energy dependence was characterized from 29.5 to 129 keV with an x-ray tube. The percentage depth dose (PDD) curves were measured from 0.5 to 20 cm and compared to an ionization chamber. RESULTS: The OPD sensitivity to visible light showed substantial degradation of the broad 450 to 600 nm peak from the donor after irradiation to 40 kGy. After irradiation, the spectral shape has a dominant absorbance peak at 370 nm, as the acceptor better withstood radiation damage. Its response to x rays stabilized to 30% after 35 kGy, with a 0.5% difference between 770 Gy increments. The OPD exhibited reproducible detection of ionizing radiation when coupled with a scintillator. Indirect detection showed a linear response from 25 to 500 cGy and constant response to dose rates from 0.31 Gy/pulse to 3.4 × 10-4  Gy/pulse. However, without the scintillator, response increased by 100% at low dose rates. Energy independence between 100 keV and 1.2 MeV advocates their use as a dosimeter without beam correction factors. A dependence on the scintillator thickness used during a comparison of the PDD to the ionizing chamber was identified. A 1-mm-thick scintillator coupled with the OPD demonstrated the best agreement of ± 3%. CONCLUSIONS: The response of OPDs to ionizing radiation has been characterized, showing promising use as a dosimeter when coupled with a plastic scintillator. The mechanisms of charge transport and trapping within organic materials varies for visible and ionizing radiation, due to differing properties for direct and indirect detection mechanisms and observing a substantial decrease in sensitivity to the visible spectrum after 40 kGy. This study proved that OPDs produce a stable response to 6-MV photons, and with a deeper understanding of the charge transport mechanisms due to exposure to ionizing radiation, they are promising candidates as the first flexible, water equivalent, real-time dosimeter.


Asunto(s)
Dosímetros de Radiación , Radiometría , Aceleradores de Partículas , Fotones , Semiconductores
8.
Phys Imaging Radiat Oncol ; 14: 48-52, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33458314

RESUMEN

BACKGROUND AND PURPOSE: Measurement of dose delivery is essential to guarantee the safety of patients undergoing medical radiation imaging or treatment procedures. This study aimed to evaluate the ability of organic semiconductors, coupled with a plastic scintillator, to measure photon dose in clinically relevant conditions, and establish its radiation hardness. Thereby, proving organic devices are capable of being a water-equivalent, mechanically flexible, real-time dosimeter. MATERIALS AND METHODS: The shelf-life of an organic photodiode was analyzed to 40 kGy by comparison of the charge-collection-efficiency of a 520 nm light emitting diode. A non-irradiated and pre-irradiated photodiode was coupled to a plastic scintillator and their response to 6 MV photons was investigated. The dose linearity, dose-per-pulse dependence and energy dependence was characterized. Finally, the percentage depth dose (PDD) between 0.5 and 20 cm was compared with ionization chamber measurements. RESULTS: Sensitivity to 6 MV photons was (190 ± 0.28) pC/cGy and (170 ± 0.11) pC/cGy for the non-irradiated and pre-irradiated photodiode biased at -2 V. The response was independent of the dose-per-pulse between 0.031 and 0.34 mGy/pulse. An energy dependence was found for low keV energies, explained by the energy dependence of the scintillator which plateaued between 70 keV and 1.2 MeV. The PDD was within ±3% of the ionization chamber. CONCLUSION: Coupling an organic photodiode with a plastic scintillator provided reliable measurement of a range of photon energies. Dose-per-pulse and energy independence advocate their use as a dosimeter, specifically image-guided treatment without beam-quality correction factors. Degradation effects of organic semiconducting materials deteriorate sensor response but can be stabilized.

9.
Med Phys ; 46(4): 1833-1839, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30629742

RESUMEN

PURPOSE: The removal of Cherenkov light in an optical dosimetry system is an important process to ensure accurate dosimetry without compromising spatial resolution. Many solutions have been presented in the literature, each with advantages and disadvantages. We present a methodology to remove Cherenkov light from a scintillator fiber optic dosimeter in a pulsed megavoltage x-ray beam using the temporal waveform across the pulse. METHODS: A sample waveform of Cherenkov light can be measured by exposing only the fiber to the beam. By assuming that the Cherenkov waveform closely matches the intensity of incident radiation, this waveform can be convoluted with the instantaneous scintillation response function to generate an expected scintillation signal. By finding the least-squares fit between these two functions and the experimental data, the estimated Cherenkov contribution can be subtracted off the net signal. This can be applied for arbitrarily complex Cherenkov waveforms (within the 2 ns timing resolution of the data acquisition), and in fact, the results suggest more fluctuations in the waveforms provide a better fit to data. RESULTS: Four beam profiles for different field sizes and energies were found with this method. They closely matched references data measured with ionization chamber with average differences across the beam no more than 4%. Noisy waveforms are assumed to be the primary cause of differences between the analyzed scintillator and IC results. We propose methods for improving the results and optimizing the data acquisition and analysis processes. CONCLUSIONS: These results demonstrate that it is possible and effective with a single probe to use function fitting of expected data to experimental to remove a complicated Cherenkov signal from the net light signal in pulsed-beam optical dosimetry.


Asunto(s)
Algoritmos , Tecnología de Fibra Óptica/instrumentación , Aceleradores de Partículas/instrumentación , Conteo por Cintilación/instrumentación , Humanos , Fantasmas de Imagen , Rayos X
10.
Phys Med ; 54: 131-136, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30337002

RESUMEN

The irradiation of scintillator-fiber optic dosimeters by clinical LINACs results in the measurement of scintillation and Cerenkov radiation. In scintillator-fiber optic dosimetry, the scintillation and Cerenkov radiation responses are separated to determine the dose deposited in the scintillator volume. Artificial neural networks (ANNs) were trained and applied in a novel single probe method for the temporal separation of scintillation and Cerenkov radiation. Six dose profiles were measured using the ANN, with the dose profiles compared to those measured using background subtraction and an ionisation chamber. The average dose discrepancy of the ANN measured dose was 2.2% with respect to the ionisation chamber dose and 1.2% with respect to the background subtraction measured dose, while the average dose discrepancy of the background subtraction dose was 1.6% with respect to the ionisation chamber dose. The ANNs performance was degraded when compared with background subtraction, arising from an inaccurate model used to synthesise ANN training data.


Asunto(s)
Redes Neurales de la Computación , Fibras Ópticas , Aceleradores de Partículas , Conteo por Cintilación/instrumentación , Humanos , Radiometría , Programas Informáticos , Factores de Tiempo
11.
Phys Med Biol ; 63(22): 225004, 2018 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-30412477

RESUMEN

Convolutional neural network (CNN) type artificial intelligences were trained to estimate the Cerenkov radiation present in the temporal response of a LINAC irradiated scintillator-fiber optic dosimeter. The CNN estimate of Cerenkov radiation is subtracted from the combined scintillation and Cerenkov radiation temporal response of the irradiated scintillator-fiber optic dosimeter, giving the sole scintillation signal, which is proportional to the scintillator dose. The CNN measured scintillator dose was compared to the background subtraction measured scintillator dose and ionisation chamber measured dose. The dose discrepancy of the CNN measured dose was on average 1.4% with respect to the ionisation chamber measured dose, matching the 1.4% average dose discrepancy of the background subtraction measured dose with respect to the ionisation chamber measured dose. The developed CNNs had an average time of 3 ms to calculate scintillator dose, permitting the CNNs presented to be applicable for dosimetry in real time.


Asunto(s)
Redes Neurales de la Computación , Aceleradores de Partículas , Conteo por Cintilación/métodos , Tecnología de Fibra Óptica/instrumentación , Tecnología de Fibra Óptica/métodos , Humanos , Dosímetros de Radiación , Dosificación Radioterapéutica , Conteo por Cintilación/instrumentación
12.
Front Psychol ; 8: 947, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28674508

RESUMEN

Lesbian, gay, and bisexual (LGB) individuals come from diverse cultural groups with differing ethnic and racial identities. However, most research on LGB people uses white western samples and studies of Afro-Caribbean diaspora often use Jamaican samples. Thus, the complexity of Afro-Caribbean LGB peoples' experiences of homophobia is largely unknown. The authors' analyses explore experiences of homophobia among LGB people in St. Lucia. Findings indicate issues of skin-shade orientated tolerance, regionalized disparities in levels of tolerance toward LGB people and regionalized passing (regionalized sexual identity shifting). Finally, the authors' findings indicate that skin shade identities and regional location influence the psychological health outcomes of homophobia experienced by LGB people in St. Lucia.

13.
Eur J Psychol ; 13(1): 16-27, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28344672

RESUMEN

The increasing ageing prison population is becoming a pressing issue throughout the criminal justice system. Alongside the rising population, are a host of health and wellbeing issues that contribute to older offenders needs whilst in prison. It has been recommended that meaningful activities can have positive effects on this population and therefore this paper uniquely reviews older offenders accounts of taking part in an arts based project, Good Vibrations, whilst imprisoned. The Good Vibrations project engages individuals in Gamelan music making with an end of project performance. This study used independent in-depth interviews to capture the voices of older offenders who took part in an art based prison project. The interview data was analysed using thematic analysis, which highlighted themes that were consistent with other populations who have taken part in a Good Vibrations project, along with specific age relating issues of mobility, motivation, identity and wellbeing.

14.
Eur J Psychol ; 13(3): 503-518, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28904598

RESUMEN

Probabilistic reasoning biases have been widely associated with levels of delusional belief ideation (Galbraith, Manktelow, & Morris, 2010; Lincoln, Ziegler, Mehl, & Rief, 2010; Speechley, Whitman, & Woodward, 2010; White & Mansell, 2009), however, little research has focused on biases occurring during every day reasoning (Galbraith, Manktelow, & Morris, 2011), and moral and crime based reasoning (Wilkinson, Caulfield, & Jones, 2014; Wilkinson, Jones, & Caulfield, 2011). 235 participants were recruited across four experiments exploring crime based reasoning through different modalities and dual processing tasks. Study one explored delusional ideation when completing a visually presented crime based reasoning task. Study two explored the same task in an auditory presentation. Study three utilised a dual task paradigm to explore modality and executive functioning. Study four extended this paradigm to the auditory modality. The results indicated that modality and delusional ideation have a significant effect on individuals reasoning about violent and non-violent crime (p < .05), which could have implication for the presentation of evidence in applied setting such as the courtroom.

15.
Int J Radiat Oncol Biol Phys ; 95(5): 1367-1377, 2016 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-27296040

RESUMEN

PURPOSE: To report toxicity and early survival data for IDEAL-CRT, a trial of dose-escalated concurrent chemoradiotherapy (CRT) for non-small cell lung cancer. PATIENTS AND METHODS: Patients received tumor doses of 63 to 73 Gy in 30 once-daily fractions over 6 weeks with 2 concurrent cycles of cisplatin and vinorelbine. They were assigned to 1 of 2 groups according to esophageal dose. In group 1, tumor doses were determined by an experimental constraint on maximum esophageal dose, which was escalated following a 6 + 6 design from 65 Gy through 68 Gy to 71 Gy, allowing an esophageal maximum tolerated dose to be determined from early and late toxicities. Tumor doses for group 2 patients were determined by other tissue constraints, often lung. Overall survival, progression-free survival, tumor response, and toxicity were evaluated for both groups combined. RESULTS: Eight centers recruited 84 patients: 13, 12, and 10, respectively, in the 65-Gy, 68-Gy, and 71-Gy cohorts of group 1; and 49 in group 2. The mean prescribed tumor dose was 67.7 Gy. Five grade 3 esophagitis and 3 grade 3 pneumonitis events were observed across both groups. After 1 fatal esophageal perforation in the 71-Gy cohort, 68 Gy was declared the esophageal maximum tolerated dose. With a median follow-up of 35 months, median overall survival was 36.9 months, and overall survival and progression-free survival were 87.8% and 72.0%, respectively, at 1 year and 68.0% and 48.5% at 2 years. CONCLUSIONS: IDEAL-CRT achieved significant treatment intensification with acceptable toxicity and promising survival. The isotoxic design allowed the esophageal maximum tolerated dose to be identified from relatively few patients.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Carcinoma de Pulmón de Células no Pequeñas/terapia , Quimioradioterapia/mortalidad , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/mortalidad , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/terapia , Traumatismos por Radiación/mortalidad , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/patología , Comorbilidad , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Prevalencia , Tasa de Supervivencia , Resultado del Tratamiento
16.
Radiother Oncol ; 113(2): 272-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25465734

RESUMEN

BACKGROUND: Rotational IMRT (VMAT and Tomotherapy) has now been implemented in many radiotherapy centres. An audit to verify treatment planning system modelling and treatment delivery has been undertaken to ensure accurate clinical implementation. MATERIAL AND METHODS: 34 institutions with 43 treatment delivery systems took part in the audit. A virtual phantom planning exercise (3DTPS test) and a clinical trial planning exercise were planned and independently measured in each institution using a phantom and array combination. Point dose differences and global gamma index (γ) were calculated in regions corresponding to PTVs and OARs. RESULTS: Point dose differences gave a mean (±sd) of 0.1±2.6% and 0.2±2.0% for the 3DTPS test and clinical trial plans, respectively. 34/43 planning and delivery combinations achieved all measured planes with >95% pixels passing γ<1 at 3%/3mm and rose to 42/43 for clinical trial plans. A statistically significant difference in γ pass rates (p<0.01) was seen between planning systems where rotational IMRT modelling had been designed for the manufacturer's own treatment delivery system and those designed independently of rotational IMRT delivery. CONCLUSIONS: A dosimetry audit of rotational radiotherapy has shown that TPS modelling and delivery for rotational IMRT can achieve high accuracy of plan delivery.


Asunto(s)
Auditoría Médica , Radioterapia de Intensidad Modulada , Planificación de Atención al Paciente , Fantasmas de Imagen , Radiometría , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/normas