1.
J Neurosurg Spine ; 38(1): 91-97, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36029261

RESUMEN

OBJECTIVE: There is a paucity of literature on pelvic fixation failure after adult spine surgery in the early postoperative period. The purpose of this study was to determine the incidence of acute pelvic fixation failure in a large single-center study and to describe the lessons learned. METHODS: The authors performed a retrospective review of adult (≥ 18 years old) patients who underwent spinal fusion with pelvic fixation (iliac, S2-alar-iliac [S2AI] screws) at a single academic medical center between 2015 and 2020. All patients had a minimum of 3 instrumented levels. The minimum follow-up was 6 months after the index spine surgery. Patients with prior pelvic fixation were excluded. Acute pelvic fixation failure was defined as revision of the pelvic screws within 6 months of the primary surgery. Patient demographics and operative, radiographic, and rod/screw parameters were collected. All rods were cobalt-chrome. All iliac and S2AI screws were closed-headed screws. RESULTS: In 358 patients, the mean age was 59.5 ± 13.6 years, and 64.0% (n = 229) were female. The mean number of instrumented levels was 11.5 ± 5.5, and 79.1% (n = 283) had ≥ 6 levels fused. Three-column osteotomies were performed in 14.2% (n = 51) of patients, and 74.6% (n = 267) had an L5-S1 interbody fusion. The mean diameter/length of pelvic screws was 8.5/86.6 mm. The mean number of pelvic screws was 2.2 ± 0.5, the mean rod diameter was 6.0 ± 0 mm, and 78.5% (n = 281) had > 2 rods crossing the lumbopelvic junction. Accessory rods extended to S1 (32.7%, n = 117) or S2/ilium (45.8%, n = 164). Acute pelvic fixation failure occurred in 1 patient (0.3%); this individual had a broken S2AI screw near the head-neck junction. This 76-year-old woman with degenerative lumbar scoliosis and chronic lumbosacral zone 1 fracture nonunion had undergone posterior instrumented fusion from T10 to pelvis with bilateral S2AI screws (8.5 × 90 mm); i.e., transforaminal lumbar interbody fusion L4-S1. The patient had persistent left buttock pain postoperatively, with radiographically confirmed breakage of the left S2AI screw 68 days after surgery. Revision included instrumentation removal at L2-pelvis and a total of 4 pelvic screws. CONCLUSIONS: The acute pelvic fixation failure rate was exceedingly low in adult spine surgery. This rate may be the result of multiple factors including the preference for multirod (> 2), closed-headed pelvic screw constructs in which large-diameter long screws are used. Increasing the number of rods and screws at the lumbopelvic junction may be important factors to consider, especially for patients with high risk for nonunion.


Asunto(s)
Escoliosis , Fusión Vertebral , Humanos , Adulto , Femenino , Persona de Mediana Edad , Anciano , Adolescente , Masculino , Tornillos Óseos , Pelvis/cirugía , Ilion/cirugía , Escoliosis/cirugía , Osteotomía , Fusión Vertebral/efectos adversos , Sacro/diagnóstico por imagen , Sacro/cirugía
2.
J Neurosurg Spine ; 38(2): 208-216, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36242579

RESUMEN

OBJECTIVE: The purpose of this study was to determine the incidence, mechanism, and potential protective strategies for pelvic fixation failure (PFF) within 2 years after adult spinal deformity (ASD) surgery. METHODS: Data for ASD patients (age ≥ 18 years, minimum of six instrumented levels) with pelvic fixation (S2-alar-iliac [S2AI] and/or iliac screws) with a minimum 2-year follow-up were consecutively collected (2015-2019). Patients with prior pelvic fixation were excluded. PFF was defined as any revision to pelvic screws, which may include broken rods across the lumbosacral junction requiring revision to pelvic screws, pseudarthrosis across the lumbosacral junction requiring revision to pelvic screws, a broken or loose pelvic screw, or sacral/iliac fracture. Patient information including demographic data and health history (age, sex, BMI, smoking status, American Society of Anesthesiologists score, osteoporosis), operative (total instrumented levels [TIL], three-column osteotomy [3CO], interbody fusion), screw (iliac, S2AI, length, diameter), rod (diameter, kickstand), rod pattern (number crossing lumbopelvic junction, lowest instrumented vertebra [LIV] of accessory rod[s], lateral connectors, dual-headed screws), and pre- and postradiographic (lumbar lordosis, pelvic incidence, pelvic tilt, major Cobb angle, lumbosacral fractional curve, C7 coronal vertical axis [CVA], T1 pelvic angle, C7 sagittal vertical axis) parameters was collected. All rods across the lumbosacral junction were cobalt-chrome. All iliac and S2AI screws were closed-headed tulips. Both univariate and multivariate analyses were performed to determine risk factors for PFF. RESULTS: Of 253 patients (mean age 58.9 years, mean TIL 13.6, 3CO 15.8%, L5-S1 interbody 74.7%, mean pelvic screw diameter/length 8.6/87 mm), the 2-year failure rate was 4.3% (n = 11). The mechanisms of failure included broken rods across the lumbosacral junction (n = 4), pseudarthrosis across the lumbosacral junction requiring revision to pelvic screws (n = 3), broken pelvic screw (n = 1), loose pelvic screw (n = 1), sacral/iliac fracture (n = 1), and painful/prominent pelvic screw (n = 1). A higher number of rods crossing the lumbopelvic junction (mean 3.8 no failure vs 2.9 failure, p = 0.009) and accessory rod LIV to S2/ilium (no failure 54.2% vs failure 18.2%, p = 0.003) were protective for failure. Multivariate analysis demonstrated that accessory rod LIV to S2/ilium versus S1 (OR 0.2, p = 0.004) and number of rods crossing the lumbar to pelvis (OR 0.15, p = 0.002) were protective, while worse postoperative CVA (OR 1.5, p = 0.028) was an independent risk factor for failure. CONCLUSIONS: The 2-year PFF rate was low relative to what is reported in the literature, despite patients undergoing long fusion constructs for ASD. The number of rods crossing the lumbopelvic junction and accessory rod LIV to S2/ilium relative to S1 alone likely increase construct stiffness. Residual postoperative coronal malalignment should be avoided to reduce PFF.


Asunto(s)
Lordosis , Seudoartrosis , Fusión Vertebral , Humanos , Adulto , Persona de Mediana Edad , Adolescente , Seudoartrosis/diagnóstico por imagen , Seudoartrosis/epidemiología , Seudoartrosis/etiología , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Pelvis/cirugía , Lordosis/diagnóstico por imagen , Lordosis/cirugía , Lordosis/etiología , Tornillos Óseos , Sacro/diagnóstico por imagen , Sacro/cirugía , Ilion/diagnóstico por imagen , Ilion/cirugía , Fusión Vertebral/efectos adversos