Radiat Prot Dosimetry ; 110(1-4): 129-34, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15353635

RESUMEN

The neutron energy spectrum of the JRC 241Am-Li(alpha,n) radionuclide source has been measured at the PTB in Germany using various spectrometry systems, such as Bonner spheres, proton recoil counters and NE213 liquid scintillators. The source photon spectrum has been measured and the neutron contamination due to traces of beryllium through the 9Be(alpha,n)12C reaction has been determined. The effects associated with source encapsulation and the materials it contains have been investigated previously, using Monte Carlo simulations, the various structures seen in the spectra have been explained and the anisotropy of fluence distributions in 4pi have been calculated and compared to measurements. These extensive high resolution spectrometry measurements have been coupled to Monte Carlo calculations to provide a realistic spectrum and new spectrum-averaged fluence-to-dose equivalent conversion coefficients for the actual 241Am-Li source.


Asunto(s)
Americio/análisis , Litio/análisis , Neutrones , Protección Radiológica/métodos , Protección Radiológica/normas , Radiometría/métodos , Radiometría/normas , Carga Corporal (Radioterapia) , Calibración/normas , Simulación por Computador , Diseño Asistido por Computadora , Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/métodos , Análisis de Falla de Equipo/normas , Alemania , Internacionalidad , Modelos Estadísticos , Método de Montecarlo , Reactores Nucleares , Exposición Profesional/análisis , Fotones , Dosis de Radiación , Protección Radiológica/instrumentación , Radioisótopos/análisis , Radiometría/instrumentación , Estándares de Referencia , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad
2.
Radiat Prot Dosimetry ; 110(1-4): 523-7, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15353702

RESUMEN

The new CANEL/T400 facility has been set-up at the Institute for Radiological Protection and Nuclear Safety (IRSN) to produce a realistic neutron field. The accurate characterisation of this neutron field is mandatory since this facility will be used as a reference neutron source. For this reason an international measuring campaign, involving four laboratories with extensive expertise in neutron metrology and spectrometry, was organised through a concerted EUROMET project. Measurements were performed with Bonner sphere (BS) systems to determine the energy distribution of the emitted neutrons over the whole energy range (from thermal energy up to a few MeV). Additional measurements were performed with proton recoil detectors to provide detailed information in the energy region above 90 keV. The results obtained by the four laboratories are in agreement with each other and are compared with a calculation performed with the MCNP4C Monte-Carlo code. As a conclusion of this exercise, a reliable characterisation of the CANEL/T400 neutron field is obtained.


Asunto(s)
Calibración/normas , Análisis de Falla de Equipo/normas , Neutrones , Protección Radiológica/instrumentación , Protección Radiológica/normas , Radiometría/instrumentación , Radiometría/normas , Algoritmos , Carga Corporal (Radioterapia) , Diseño de Equipo , Análisis de Falla de Equipo/métodos , Europa (Continente) , Estudios de Factibilidad , Humanos , Dosis de Radiación , Protección Radiológica/métodos , Radiometría/métodos , Estándares de Referencia , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Medición de Riesgo/normas , Factores de Riesgo , Sensibilidad y Especificidad