Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Rev Sci Instrum ; 92(8): 083504, 2021 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-34470443

RESUMEN

An innovative tangential-view soft x-ray (SXR) tomographic imaging measurement was developed on the TS-6 spherical tokamak merging device as a key diagnostic for investigating the mechanism of electron acceleration. In order to measure SXR with different energy ranges, two micro-channel plates (MCPs) are, respectively, installed in two vacuum chambers, which are equipped with different filters. Especially designed lenses and fiber bundles serve as an optical system to transfer images from phosphor plates of MCPs to a high speed imaging system. This design also enables us to simultaneously measure two images appearing on phosphor plates of MCPs by just one high speed imaging system. The temporal and spatial resolution of this diagnostic can be up to 5 µs and 4 mm, respectively, at present. The tomographic method based on the Phillips-Tikhonov regularization is employed to reconstruct line-integrated images into the local emissivity of SXR, which reflects the spatial distribution of high-energy electrons. Owing to this diagnostic, we successfully measured SXR emitted from the downstream region of magnetic reconnection in TS-6 merging experiments for the first time. The energy range of SXR turned out to be higher than 100 eV but lower than 400 eV.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda