1.
Sensors (Basel) ; 22(9)2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35591042

RESUMEN

Electrohysterogram (EHG) is a promising method for noninvasive monitoring of uterine electrical activity. The main purpose of this study was to characterize the multichannel EHG signals to distinguish between term delivery and preterm birth, as well as deliveries within and beyond 24 h. A total of 219 pregnant women were grouped in two ways: (1) term delivery (TD), threatened preterm labor (TPL) with the outcome of preterm birth (TPL_PB), and TPL with the outcome of term delivery (TPL_TD); (2) EHG recording time to delivery (TTD) ≤ 24 h and TTD > 24 h. Three bipolar EHG signals were analyzed for the 30 min recording. Six EHG features between multiple channels, including multivariate sample entropy, mutual information, correlation coefficient, coherence, direct partial Granger causality, and direct transfer entropy, were extracted to characterize the coupling and information flow between channels. Significant differences were found for these six features between TPL and TD, and between TTD ≤ 24 h and TTD > 24 h. No significant difference was found between TPL_PB and TPL_TD. The results indicated that EHG signals of TD were more regular and synchronized than TPL, and stronger coupling between multichannel EHG signals was exhibited as delivery approaches. In addition, EHG signals propagate downward for the majority of pregnant women regardless of different labors. In conclusion, the coupling and propagation features extracted from multichannel EHG signals could be used to differentiate term delivery and preterm birth and may predict delivery within and beyond 24 h.


Asunto(s)
Trabajo de Parto , Trabajo de Parto Prematuro , Nacimiento Prematuro , Electromiografía/métodos , Femenino , Humanos , Recién Nacido , Trabajo de Parto Prematuro/diagnóstico , Embarazo , Contracción Uterina
2.
Sensors (Basel) ; 22(12)2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35746295

RESUMEN

Swallowing is a complex sequence of highly regulated and coordinated skeletal and smooth muscle activity. Previous studies have attempted to determine the temporal relationship between the muscles to establish the activation sequence pattern, assessing functional muscle coordination with cross-correlation or coherence, which is seriously impaired by volume conduction. In the present work, we used conditional Granger causality from surface electromyography signals to analyse the directed functional coordination between different swallowing muscles in both healthy and dysphagic subjects ingesting saliva, water, and yoghurt boluses. In healthy individuals, both bilateral and ipsilateral muscles showed higher coupling strength than contralateral muscles. We also found a dominant downward direction in ipsilateral supra and infrahyoid muscles. In dysphagic subjects, we found a significantly higher right-to-left infrahyoid, right ipsilateral infra-to-suprahyoid, and left ipsilateral supra-to-infrahyoid interactions, in addition to significant differences in the left ipsilateral muscles between bolus types. Our results suggest that the functional coordination analysis of swallowing muscles contains relevant information on the swallowing process and possible dysfunctions associated with dysphagia, indicating that it could potentially be used to assess the progress of the disease or the effectiveness of rehabilitation therapies.


Asunto(s)
Trastornos de Deglución , Deglución , Deglución/fisiología , Electromiografía/métodos , Humanos , Músculos del Cuello/fisiología
3.
Sensors (Basel) ; 22(14)2022 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-35890778

RESUMEN

Due to its high sensitivity, electrohysterography (EHG) has emerged as an alternative technique for predicting preterm labor. The main obstacle in designing preterm labor prediction models is the inherent preterm/term imbalance ratio, which can give rise to relatively low performance. Numerous studies obtained promising preterm labor prediction results using the synthetic minority oversampling technique. However, these studies generally overestimate mathematical models' real generalization capacity by generating synthetic data before splitting the dataset, leaking information between the training and testing partitions and thus reducing the complexity of the classification task. In this work, we analyzed the effect of combining feature selection and resampling methods to overcome the class imbalance problem for predicting preterm labor by EHG. We assessed undersampling, oversampling, and hybrid methods applied to the training and validation dataset during feature selection by genetic algorithm, and analyzed the resampling effect on training data after obtaining the optimized feature subset. The best strategy consisted of undersampling the majority class of the validation dataset to 1:1 during feature selection, without subsequent resampling of the training data, achieving an AUC of 94.5 ± 4.6%, average precision of 84.5 ± 11.7%, maximum F1-score of 79.6 ± 13.8%, and recall of 89.8 ± 12.1%. Our results outperformed the techniques currently used in clinical practice, suggesting the EHG could be used to predict preterm labor in clinics.


Asunto(s)
Trabajo de Parto Prematuro , Nacimiento Prematuro , Femenino , Humanos , Recién Nacido , Modelos Teóricos , Trabajo de Parto Prematuro/diagnóstico , Nacimiento Prematuro/diagnóstico , Útero
4.
Sensors (Basel) ; 21(17)2021 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-34502772

RESUMEN

The optimization performed in this study is based on the finite dimensions model of the concentric ring electrode as opposed to the negligible dimensions model used in the past. This makes the optimization problem comprehensive, as all of the electrode parameters including, for the first time, the radius of the central disc and individual widths of concentric rings, are optimized simultaneously. The optimization criterion used is maximizing the accuracy of the surface Laplacian estimation, as the ability to estimate the Laplacian at each electrode constitutes primary biomedical significance of concentric ring electrodes. For tripolar concentric ring electrodes, the optimal configuration was compared to previously proposed linearly increasing inter-ring distances and constant inter-ring distances configurations of the same size and based on the same finite dimensions model. The obtained analytic results suggest that previously proposed configurations correspond to almost two-fold and more than three-fold increases in the Laplacian estimation error compared with the optimal configuration proposed in this study, respectively. These analytic results are confirmed using finite element method modeling, which was adapted to the finite dimensions model of the concentric ring electrode for the first time. Moreover, the finite element method modeling results suggest that optimal electrode configuration may also offer improved sensitivity and spatial resolution.


Asunto(s)
Análisis de Elementos Finitos , Simulación por Computador , Electrodos
5.
Sensors (Basel) ; 21(10)2021 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-34065847

RESUMEN

Electrohysterography (EHG) has emerged as an alternative technique to predict preterm labor, which still remains a challenge for the scientific-technical community. Based on EHG parameters, complex classification algorithms involving non-linear transformation of the input features, which clinicians found difficult to interpret, were generally used to predict preterm labor. We proposed to use genetic algorithm to identify the optimum feature subset to predict preterm labor using simple classification algorithms. A total of 203 parameters from 326 multichannel EHG recordings and obstetric data were used as input features. We designed and validated 3 base classifiers based on k-nearest neighbors, linear discriminant analysis and logistic regression, achieving F1-score of 84.63 ± 2.76%, 89.34 ± 3.5% and 86.87 ± 4.53%, respectively, for incoming new data. The results reveal that temporal, spectral and non-linear EHG parameters computed in different bandwidths from multichannel recordings provide complementary information on preterm labor prediction. We also developed an ensemble classifier that not only outperformed base classifiers but also reduced their variability, achieving an F1-score of 92.04 ± 2.97%, which is comparable with those obtained using complex classifiers. Our results suggest the feasibility of developing a preterm labor prediction system with high generalization capacity using simple easy-to-interpret classification algorithms to assist in transferring the EHG technique to clinical practice.


Asunto(s)
Trabajo de Parto Prematuro , Útero , Algoritmos , Electromiografía , Femenino , Humanos , Recién Nacido , Trabajo de Parto Prematuro/diagnóstico , Embarazo
6.
Sensors (Basel) ; 21(18)2021 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-34577278

RESUMEN

One of the remaining challenges for the scientific-technical community is predicting preterm births, for which electrohysterography (EHG) has emerged as a highly sensitive prediction technique. Sample and fuzzy entropy have been used to characterize EHG signals, although they require optimizing many internal parameters. Both bubble entropy, which only requires one internal parameter, and dispersion entropy, which can detect any changes in frequency and amplitude, have been proposed to characterize biomedical signals. In this work, we attempted to determine the clinical value of these entropy measures for predicting preterm birth by analyzing their discriminatory capacity as an individual feature and their complementarity to other EHG characteristics by developing six prediction models using obstetrical data, linear and non-linear EHG features, and linear discriminant analysis using a genetic algorithm to select the features. Both dispersion and bubble entropy better discriminated between the preterm and term groups than sample, spectral, and fuzzy entropy. Entropy metrics provided complementary information to linear features, and indeed, the improvement in model performance by including other non-linear features was negligible. The best model performance obtained an F1-score of 90.1 ± 2% for testing the dataset. This model can easily be adapted to real-time applications, thereby contributing to the transferability of the EHG technique to clinical practice.


Asunto(s)
Nacimiento Prematuro , Análisis Discriminante , Electromiografía , Entropía , Femenino , Humanos , Recién Nacido , Embarazo , Nacimiento Prematuro/diagnóstico , Útero
7.
Sensors (Basel) ; 21(7)2021 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-33916679

RESUMEN

Preterm birth is the leading cause of death in newborns and the survivors are prone to health complications. Threatened preterm labor (TPL) is the most common cause of hospitalization in the second half of pregnancy. The current methods used in clinical practice to diagnose preterm labor, the Bishop score or cervical length, have high negative predictive values but not positive ones. In this work we analyzed the performance of computationally efficient classification algorithms, based on electrohysterographic recordings (EHG), such as random forest (RF), extreme learning machine (ELM) and K-nearest neighbors (KNN) for imminent labor (<7 days) prediction in women with TPL, using the 50th or 10th-90th percentiles of temporal, spectral and nonlinear EHG parameters with and without obstetric data inputs. Two criteria were assessed for the classifier design: F1-score and sensitivity. RFF1_2 and ELMF1_2 provided the highest F1-score values in the validation dataset, (88.17 ± 8.34% and 90.2 ± 4.43%) with the 50th percentile of EHG and obstetric inputs. ELMF1_2 outperformed RFF1_2 in sensitivity, being similar to those of ELMSens (sensitivity optimization). The 10th-90th percentiles did not provide a significant improvement over the 50th percentile. KNN performance was highly sensitive to the input dataset, with a high generalization capability.


Asunto(s)
Trabajo de Parto , Trabajo de Parto Prematuro , Nacimiento Prematuro , Algoritmos , Femenino , Humanos , Recién Nacido , Trabajo de Parto Prematuro/diagnóstico , Embarazo , Nacimiento Prematuro/diagnóstico , Útero
8.
Sensors (Basel) ; 20(11)2020 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-32466584

RESUMEN

Postpartum hemorrhage (PPH) is one of the major causes of maternal mortality and morbidity worldwide, with uterine atony being the most common origin. Currently there are no obstetrical techniques available for monitoring postpartum uterine dynamics, as tocodynamometry is not able to detect weak uterine contractions. In this study, we explored the feasibility of monitoring postpartum uterine activity by non-invasive electrohysterography (EHG), which has been proven to outperform tocodynamometry in detecting uterine contractions during pregnancy. A comparison was made of the temporal, spectral, and non-linear parameters of postpartum EHG characteristics of vaginal deliveries and elective cesareans. In the vaginal delivery group, EHG obtained a significantly higher amplitude and lower kurtosis of the Hilbert envelope, and spectral content was shifted toward higher frequencies than in the cesarean group. In the non-linear parameters, higher values were found for the fractal dimension and lower values for Lempel-Ziv, sample entropy and spectral entropy in vaginal deliveries suggesting that the postpartum EHG signal is extremely non-linear but more regular and predictable than in a cesarean. The results obtained indicate that postpartum EHG recording could be a helpful tool for earlier detection of uterine atony and contribute to better management of prophylactic uterotonic treatment for PPH prevention.


Asunto(s)
Cesárea , Fenómenos Electrofisiológicos , Trabajo de Parto , Contracción Uterina , Monitoreo Uterino , Adulto , Electromiografía , Femenino , Humanos , Periodo Posparto , Embarazo , Vagina
9.
Entropy (Basel) ; 22(7)2020 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-33286515

RESUMEN

Electrohysterography (EHG) has been shown to provide relevant information on uterine activity and could be used for predicting preterm labor and identifying other maternal fetal risks. The extraction of high-quality robust features is a key factor in achieving satisfactory prediction systems from EHG. Temporal, spectral, and non-linear EHG parameters have been computed to characterize EHG signals, sometimes obtaining controversial results, especially for non-linear parameters. The goal of this work was to assess the performance of EHG parameters in identifying those robust enough for uterine electrophysiological characterization. EHG signals were picked up in different obstetric scenarios: antepartum, including women who delivered on term, labor, and post-partum. The results revealed that the 10th and 90th percentiles, for parameters with falling and rising trends as labor approaches, respectively, differentiate between these obstetric scenarios better than median analysis window values. Root-mean-square amplitude, spectral decile 3, and spectral moment ratio showed consistent tendencies for the different obstetric scenarios as well as non-linear parameters: Lempel-Ziv, sample entropy, spectral entropy, and SD1/SD2 when computed in the fast wave high bandwidth. These findings would make it possible to extract high quality and robust EHG features to improve computer-aided assessment tools for pregnancy, labor, and postpartum progress and identify maternal fetal risks.

10.
Sensors (Basel) ; 19(17)2019 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-31480426

RESUMEN

Surface Laplacian estimates via concentric ring electrodes (CREs) have proven to enhance spatial resolution compared to conventional disc electrodes, which is of great importance for P-wave analysis. In this study, Laplacian estimates for traditional bipolar configuration (BC), two tripolar configurations with linearly decreasing and increasing inter-ring distances (TCLDIRD and TCLIIRD, respectively), and quadripolar configuration (QC) were obtained from cardiac recordings with pentapolar CREs placed at CMV1 and CMV2 positions. Normalized P-wave amplitude (NAP) was computed to assess the contrast to study atrial activity. Signals were of good quality (20-30 dB). Atrial activity was more emphasized at CMV1 (NAP ≃ 0.19-0.24) compared to CMV2 (NAP ≃ 0.08-0.10). Enhanced spatial resolution of TCLIIRD and QC resulted in higher NAP values than BC and TCLDIRD. Comparison with simultaneous standard 12-lead ECG proved that Laplacian estimates at CMV1 outperformed all the limb and chest standard leads in the contrast to study P-waves. Clinical recordings with CRE at this position could allow more detailed observation of atrial activity and facilitate the diagnosis of associated pathologies. Furthermore, such recordings would not require additional electrodes on limbs and could be performed wirelessly, so it should also be suitable for ambulatory monitoring, for example, using cardiac Holter monitors.


Asunto(s)
Electrocardiografía/métodos , Electrodos , Dispositivos Electrónicos Vestibles
11.
Sensors (Basel) ; 18(2)2018 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-29385719

RESUMEN

Developing new types of optimized electrodes for specific biomedical applications can substantially improve the quality of the sensed signals. Concentric ring electrodes have been shown to provide enhanced spatial resolution to that of conventional disc electrodes. A sensor with different electrode sizes and configurations (monopolar, bipolar, etc.) that provides simultaneous records would be very helpful for studying the best signal-sensing arrangement. A 5-pole electrode with an inner disc and four concentric rings of different sizes was developed and tested on surface intestinal myoelectrical recordings from healthy humans. For good adaptation to a curved body surface, the electrode was screen-printed onto a flexible polyester substrate. To facilitate clinical use, it is self-adhesive, incorporates a single connector and can perform dry or wet (with gel) recordings. The results show it to be a versatile electrode that can evaluate the optimal configuration for the identification of the intestinal slow wave and reject undesired interference. A bipolar concentric record with an outer ring diameter of 30 mm, a foam-free adhesive material, and electrolytic gel gave the best results.

12.
Sensors (Basel) ; 18(1)2018 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-29361722

RESUMEN

Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment.


Asunto(s)
Textiles , Electrocardiografía , Electrodos , Impresión , Tiofenos
13.
Brain Sci ; 14(6)2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38928610

RESUMEN

Alcohol misuse is associated with altered punishment and reward processing. Here, we investigated neural network responses to reward and punishment and the molecular profiles of the connectivity features predicting alcohol use severity in young adults. We curated the Human Connectome Project data and employed connectome-based predictive modeling (CPM) to examine how functional connectivity (FC) features during wins and losses are associated with alcohol use severity, quantified by Semi-Structured Assessment for the Genetics of Alcoholism, in 981 young adults. We combined the CPM findings and the JuSpace toolbox to characterize the molecular profiles of the network connectivity features of alcohol use severity. The connectomics predicting alcohol use severity appeared specific, comprising less than 0.12% of all features, including medial frontal, motor/sensory, and cerebellum/brainstem networks during punishment processing and medial frontal, fronto-parietal, and motor/sensory networks during reward processing. Spatial correlation analyses showed that these networks were associated predominantly with serotonergic and GABAa signaling. To conclude, a distinct pattern of network connectivity predicted alcohol use severity in young adult drinkers. These "neural fingerprints" elucidate how alcohol misuse impacts the brain and provide evidence of new targets for future intervention.

14.
Phys Eng Sci Med ; 47(2): 663-677, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38436885

RESUMEN

Functional gastric disorders entail chronic or recurrent symptoms, high prevalence and a significant financial burden. These disorders do not always involve structural abnormalities and since they cannot be diagnosed by routine procedures, electrogastrography (EGG) has been proposed as a diagnostic alternative. However, the method still has not been transferred to clinical practice due to the difficulty of identifying gastric activity because of the low-frequency interference caused by skin-electrode contact potential in obtaining spatiotemporal information by simple procedures. This work attempted to robustly identify the gastric slow wave (SW) main components by applying multivariate variational mode decomposition (MVMD) to the multichannel EGG. Another aim was to obtain the 2D SW vectorgastrogram VGGSW from 4 electrodes perpendicularly arranged in a T-shape and analyse its dynamic trajectory and recurrence quantification (RQA) to assess slow wave vector movement in healthy subjects. The results revealed that MVMD can reliably identify the gastric SW, with detection rates over 91% in fasting postprandial subjects and a frequency instability of less than 5.3%, statistically increasing its amplitude and frequency after ingestion. The VGGSW dynamic trajectory showed a statistically higher predominance of vertical displacement after ingestion. RQA metrics (recurrence ratio, average length, entropy, and trapping time) showed a postprandial statistical increase, suggesting that gastric SW became more intense and coordinated with a less complex VGGSW and higher periodicity. The results support the VGGSW as a simple technique that can provide relevant information on the "global" spatial pattern of gastric slow wave propagation that could help diagnose gastric pathologies.


Asunto(s)
Voluntarios Sanos , Estómago , Humanos , Estómago/fisiología , Adulto , Masculino , Femenino , Movimiento/fisiología , Análisis Multivariante , Adulto Joven , Electrodos , Procesamiento de Señales Asistido por Computador , Periodo Posprandial/fisiología
15.
Physiol Meas ; 43(8)2022 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-35896091

RESUMEN

Objective.The slow wave (SW) of the electrohysterogram (EHG) may contain relevant information on the electrophysiological condition of the uterus throughout pregnancy and labor. Our aim was to assess differences in the SW as regards the imminence of labor and the directionality of uterine myoelectrical activity.Approach. The SW of the EHG was extracted from the signals of the Icelandic 16-electrode EHG database in the bandwidth [5, 30] mHz and its power, spectral content, complexity and synchronization between the horizontal (X) and vertical (Y) directions were characterized by the root mean square (RMS), dominant frequency (domF), sample entropy (SampEn) and maximum cross-correlation (CCmax) of the signals, respectively. Significant differences between parameters at time-to-delivery (TTD) ≤7 versus >7 days and between the horizontal versus vertical directions were assessed.Main results.The SW power significantly increased in both directions as labor approached (TTD ≤ 7d versus >7d (mean±SD):RMSx = 0.12 ± 0.10 versus 0.08 ± 0.06 mV;RMSy = 0.12 ± 0.09 versus 0.08 ± 0.05 mV), as well as the dominant frequency in the horizontal direction (domFx= 9.1 ± 1.3 versus 8.5 ± 1.2mHz) and the synchronization between both directions (CCmax= 0.44 ± 0.16 versus 0.36 ± 0.14). Furthermore, its complexity decreased in the vertical direction (SampEny= 6.13·10-2 ± 8.7·10-3versus 6.50·10-2 ± 8.3·10-3), suggesting a higher cell-to-cell electrical coupling. Whereas there were no differences between the SW features in both directions in the general population, statistically significant differences were obtained between them in individuals in many cases.Significance.Our results suggest that the SW of the EHG is related to bioelectrical events in the uterus and could provide objective information to clinicians in challenging obstetric scenarios.


Asunto(s)
Trabajo de Parto , Monitoreo Uterino , Adolescente , Electrodos , Electromiografía/métodos , Fenómenos Electrofisiológicos , Femenino , Humanos , Embarazo , Contracción Uterina/fisiología , Monitoreo Uterino/métodos , Útero/fisiología
16.
Comput Biol Med ; 148: 105957, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35981454

RESUMEN

BACKGROUND AND OBJECTIVE: The prevalence of atrial fibrillation (AF) has tripled in the last 50 years due to population aging. High-frequency (DFdriver) activated atrial regions lead the activation of the rest of the atria, disrupting the propagation wavefront. Fourier based spectral analysis of body surface potential maps have been proposed for DFdriver identification, although these approaches present serious drawbacks due to their limited spectral resolution for short AF epochs and the blurring effect of the volume conductor. Laplacian signals (BC-ECG) from bipolar concentric ring electrodes (CRE) have been shown to outperform the spatial resolution achieved with conventional unipolar recordings. Our aimed was to determine the best DFdriver estimator in endocardial electrograms and to assess the BC-ECG capacity of CRE to quantify AF activity non-invasively. METHODS: 31 AF episodes were simulated using realistic tridimensional models of the atria electrical activity and torso. Periodogram and autoregressive (AR) spectral estimators were computed and the percentile (P90th, P95th and P98th) to impose on the dominant frequencies (DFs) across whole atria to define the best DFdriver estimator evaluated. The identification of DFdriver on DFs from BC-ECG and unipolar surface signals with conventional disc electrodes was compared. RESULTS: The best DFdriver estimator was P95th and AR order 100. BC-ECG signals allowed better detection of AF activity than unipolar signals, with a significantly greater percentage of electrode locations in which DFdriver was identified (p-value 0.0095). CONCLUSIONS: The use of BC-ECG signals for body surface Laplacian potential mapping with CRE could be helpful for better AF diagnosis, prognosis and ablation procedures than those with conventional disk electrodes.


Asunto(s)
Fibrilación Atrial , Mapeo del Potencial de Superficie Corporal , Electrodos , Atrios Cardíacos , Humanos
17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 7244-7247, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34892770

RESUMEN

Concentric ring electrodes are noninvasive and wearable sensors for electrophysiological measurement capable of estimating the surface Laplacian (second spatial derivative of surface potential) at each electrode. Significant progress has been made toward optimization of inter-ring distances (distances between the recording surfaces of the electrode), maximizing the accuracy of the surface Laplacian estimate based on the negligible dimensions model of the electrode. However, novel finite dimensions model offers comprehensive optimization including all of the electrode parameters simultaneously by including the radius of the central disc and the widths of the concentric rings into the model. Recently, such comprehensive optimization problem has been solved analytically for the tripolar electrode configuration. This study, for the first time, introduces a finite dimensions model based finite element method model (as opposed to the negligible dimensions model based one used in the past) to confirm the analytic results. Specifically, finite element method modeling results confirmed that previously proposed linearly increasing inter-ring distances and constant inter-ring distances configurations of tripolar concentric ring electrodes correspond to an almost two-fold and more than three-fold increases in relative and normalized maximum errors of Laplacian estimation when directly compared to the optimal tripolar concentric ring electrode configuration of the same size.Clinical Relevance- This study assesses and confirms the electrode configuration that maximizes the accuracy of the estimated Laplacian recorded via concentric ring electrodes. Therefore, it is potentially useful for designing future concentric ring electrodes for diagnostic purposes such as localization of epileptic foci.


Asunto(s)
Radio (Anatomía) , Simulación por Computador , Electrodos , Análisis de Elementos Finitos
18.
IEEE Trans Biomed Eng ; 68(3): 1005-1014, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32746073

RESUMEN

Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (Rins/noise), (4) basal sEMG with ECG (Rins/cardio) and (5) expiratory sEMG without ECG (Rins/exp). Spectral power, Rins/noise and Rins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of Rins/cardio and significantly higher median frequencies were obtained for CREs. Rins/noise and Rins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement.


Asunto(s)
Diafragma , Músculos Respiratorios , Electrocardiografía , Electrodos , Electromiografía , Humanos , Músculo Esquelético
19.
Comput Methods Biomech Biomed Engin ; 22(4): 418-425, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30714398

RESUMEN

The purpose of this study was to develop a tool able to distinguish between subjects who have haemophilic arthropathy in lower limbs and those who do not by analyzing the centre of pressure displacement. The second objective was to assess the possible different responses of haemophiliacs and healthy subjects by creating a classifier that could distinguish between both groups. Fifty-four haemophilic patients (28 with and 26 without arthropathy) and 23 healthy subjects took part voluntarily in the study. A force plate was used to measure postural stability. A total of 276 centre of pressure displacement parameters were calculated under different conditions: unipedal/bipedal balance with eyes open/closed. These parameters were used to design a Quadratic Discriminant Analysis classifier. The arthropathy versus non-arthropathy classifier had an overall accuracy of 97.5% when only 10 features were used in its design. Similarly, the haemophiliac versus non-haemophiliac classifier had an overall accuracy of 97.2% when only 7 features were used. In conclusion, an objective haemophilic arthropathy in lower limbs evaluation system was developed by analyzing centre of pressure displacement signals. The haemophiliac vs. non-haemophiliac classifier designed was also able to corroborate the existing differences in postural control between haemophilic patients (with and without arthropathy) and healthy subjects.


Asunto(s)
Hemartrosis/fisiopatología , Equilibrio Postural/fisiología , Adulto , Análisis Discriminante , Voluntarios Sanos , Hemartrosis/complicaciones , Hemofilia A/complicaciones , Hemofilia A/fisiopatología , Humanos
20.
J Matern Fetal Neonatal Med ; 32(10): 1586-1594, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-29251182

RESUMEN

OBJECTIVE: The objective of this study is to compare the uterine activity response between women administered dinoprostone (prostaglandin E2) and misoprostol (prostaglandin E1) for induction of labour (IOL) by analysing not only the traditional obstetric data but also the parameters extracted from uterine electrohysterogram (EHG). METHODS: Two cohorts were defined: misoprostol (25-µg vaginal tablets; 251 women) and dinoprostone cohort (10 mg vaginal inserts; 249 women). All the mothers were induced by a medical indication of a Bishop Score < = 6. RESULTS: The misoprostol cohort was associated with a shorter time to achieve active labour (p = .017) and vaginal delivery (p = .009) and with a higher percentage of vaginal delivery in less than 24 h in mothers with a very unfavourable cervix score (risk ratio (RR): 1.41, IC95% 1.17-1.69, p = .002). Successful inductions with misoprostol showed EHG parameter values significantly higher than basal state for amplitude and pseudo Montevideo units (PMU) 60' after drug administration, while spectral parameters significantly increased after 150'. This response was not observed in failed inductions. In the successful dinoprostone group, the duration and number of contractions increased significantly after 120', PMU did so after 180', and no significant differences were found for spectral parameters, possibly due to the slower pharmacokinetics of this drug. CONCLUSION: Successful inductions of labour by misoprostol are associated with earlier effective contractions than in labours induced by dinoprostone.


Asunto(s)
Maduración Cervical/efectos de los fármacos , Dinoprostona/administración & dosificación , Misoprostol/administración & dosificación , Oxitócicos , Contracción Uterina/efectos de los fármacos , Administración Intravaginal , Adulto , Estudios de Cohortes , Parto Obstétrico/estadística & datos numéricos , Electromiografía , Femenino , Humanos , Trabajo de Parto Inducido/métodos , Embarazo , Resultado del Embarazo , Factores de Tiempo , Monitoreo Uterino