Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Pharm Biomed Anal ; 45(5): 730-5, 2007 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-17920225

RESUMEN

The method for the determination of biotin by high performance liquid chromatography (HPLC) coupled with coulometric detector is presented here. Chromatographic and detection conditions were tested. A LiChrospher 60RP-select B column (250 mm x 4 mm; 5 microm) and the mobile phase containing 0.24 mol/L aqueous solution of acetic acid and acetonitrile in the ratio 85:15 (v/v) were found as the most suitable. The flow rate was 1 mL/min and the injected volume of the sample was 20 microL. The hydrodynamic voltammogram of biotin was measured and according to obtained data the detection parameters were set--channel I 600 mV, channel II 900 mV, sensitivity 1 microA. The developed method has been validated. The calibration curve is linear in the range 15-3600 ng/mL, correlation coefficient is 0.9998, limits of detection and quantification are 5 and 15 ng/mL, respectively. Recovery of the spiked samples was 98.67% with R.S.D. 0.255% on average. The developed method has been successfully applied for determination of biotin in pharmaceutical preparations.


Asunto(s)
Biotina/análisis , Cromatografía Líquida de Alta Presión/métodos , Electroquímica/métodos , Preparaciones Farmacéuticas/análisis , Tecnología Farmacéutica/métodos , Biotina/química , Estructura Molecular , Preparaciones Farmacéuticas/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta
2.
J Chromatogr A ; 1137(1): 22-9, 2006 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-17045279

RESUMEN

A simple and sensitive liquid chromatography (LC) method was developed for the simultaneous determination of eight quinolones in pig plasma samples. The following two methods of detection were used: ultraviolet (UV) and mass spectrometry with electrospray ionization (ESI/MS). Sample preparation consisted of solid-phase extraction (SPE) on Strata X cartridges prior to the analysis by LC/UV or LC/ESI/MS. The recovery, linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy of the method were evaluated using spiked pig plasma samples. The suitability of the method for pharmacokinetic studies was evaluated by determining the concentrations of enrofloxacin (ENR) and ciprofloxacin (CIP) also in pig plasma, after administration of 200mg of enrofloxacin per kilogram of fodder during 5 consecutive days.


Asunto(s)
Cromatografía Liquida/métodos , Quinolonas/sangre , Extracción en Fase Sólida/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Ciprofloxacina/farmacocinética , Enrofloxacina , Fluoroquinolonas/farmacocinética , Quinolonas/farmacocinética , Reproducibilidad de los Resultados , Espectrofotometría Ultravioleta , Porcinos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda