Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Mikrochim Acta ; 191(1): 64, 2023 12 29.
Artículo en Inglés | MEDLINE | ID: mdl-38157059

RESUMEN

A "turn-on" aptasensor for label-free and cell-free EpCAM detection was constructed by employing magnetic α-Fe2O3/Fe3O4@Au nanocomposites as a matrix for signal amplification and double-stranded complex (SH-DNA/Apt probes) immobilization through Au-S binding. α-Fe2O3/Fe3O4@Au could be efficiently assembled into uniform and stable self-assembly films via magnetic-induced self-assembly technique on a magnetic glassy carbon electrode (MGCE). The effectiveness of the platform for EpCAM detection was confirmed through differential pulse voltammetry (DPV). Under optimized conditions, the platform exhibited excellent specificity for EpCAM, and a strong linear correlation was observed between the current and the logarithm of EpCAM protein concentration in the range 1 pg/mL-1000 pg/mL (R2 = 0.9964), with a limit of detection (LOD) of 0.27 pg/mL. Furthermore, the developed platform demonstrated good stability during a 14-day storage test, with fluctuations remaining below 93.33% of the initial current value. Promising results were obtained when detecting EpCAM in spiked serum samples, suggesting its potential as a point-of-care (POC) testing.


Asunto(s)
Técnicas Biosensibles , Ácidos Nucleicos , Molécula de Adhesión Celular Epitelial , Técnicas Biosensibles/métodos , Límite de Detección , Electrodos
2.
Bioelectrochemistry ; 157: 108678, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38452441

RESUMEN

A type of electrochemical biosensors based on magnetic Fe3O4/α-Fe2O3 heterogeneous nanosheets was constructed to detect Tau proteins for early diagnosis and intervention therapy of Alzheimer's disease (AD). Firstly, Fe3O4/α-Fe2O3 heterogeneous nanosheets were fabricated as the substrate to realize magnetic self-assembly and magnetic separation to improve current response, and Fe3O4/α-Fe2O3@Au-Apt/ssDNA/MCH biosensors were successfully constructed through the reduction process of chloroauric acid, the immobilizations of aptamer (Apt) and ssDNA, and the intercept process of 6-Mercapto-1-hexanol (MCH); the construction process of the electrochemical biosensor was monitored using Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), and the factors affecting the current response of this sensor (concentration of Fe3O4/α-Fe2O3@Au and Apt/ssDNA, incubation temperature and time of Tau) were explored and optimized using differential pulse voltammetry (DPV). Analyzing the performance of this sensor under optimal conditions, the linear range was finally obtained to be 0.1 pg/mL-10 ng/mL, the limit of detection (LOD) was 0.08 pg/mL, and the limit of quantification (LOQ) was 0.28 pg/mL. The selectivity, reproducibility and stability of the biosensors were further investigated, and in a really sample analysis using human serum, the recoveries were obtained in the range of 93.93 %-107.39 %, with RSD ranging from 1.05 % to 1.94 %.


Asunto(s)
Técnicas Biosensibles , Proteínas tau , Humanos , Reproducibilidad de los Resultados , Límite de Detección , Técnicas Biosensibles/métodos , Fenómenos Magnéticos , Técnicas Electroquímicas/métodos , Electrodos , Oro/química
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda