Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 157
Filtrar
1.
Br Poult Sci ; 64(4): 467-475, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36939295

RESUMEN

1. The H9N2 subtype avian influenza virus can infect both chickens and humans. Previous studies have reported a role for erythrocytes in immunity. However, the role of H9N2 against chicken erythrocytes and the presence of complement-related genes in erythrocytes has not been studied. This research investigated the effect of H9N2 on complement-associated gene expression in chicken erythrocytes.2. The expression of complement-associated genes (C1s, C1q, C2, C3, C3ar1, C4, C4a, C5, C5ar1, C7, CD93 and CFD) was detected by reverse transcription-polymerase chain reaction (RT-PCR). Quantitative Real-Time PCR (qRT-PCR) was used to analyse the differential expression of complement-associated genes in chicken erythrocytes at 0 h, 2 h, 6 h and 10 h after the interaction between H9N2 virus and chicken erythrocytes in vitro and 3, 7 and 14 d after H9N2 virus nasal infection of chicks.3. Expression levels of C1q, C4, C1s, C2, C3, C5, C7 and CD93 were significantly up-regulated at 2 h and significantly down-regulated at 10 h. Gene expression levels of C1q, C3ar1, C4a, CFD and C5ar1 were seen to be different at each time point. The expression levels of C1q, C4, C1s, C2, C3, C5, C7, CFD, C3ar1, C4a and C5ar1 were significantly up-regulated at 7 d and the gene expression of levels of C3, CD93 and C5ar1 were seen to be different at each time point.4. The results confirmed that all the complement-associated genes were expressed in chicken erythrocytes and showed the H9N2 virus interaction with chicken erythrocytes and subsequent regulation of chicken erythrocyte complement-associated genes expression. This study reported, for the first time, the relationship between H9N2 and complement system of chicken erythrocytes, which will provide a foundation for further research into the prevention and control of H9N2 infection.


Asunto(s)
Subtipo H9N2 del Virus de la Influenza A , Gripe Aviar , Humanos , Animales , Pollos/genética , Subtipo H9N2 del Virus de la Influenza A/genética , Gripe Aviar/genética , Gripe Aviar/prevención & control , Complemento C1q/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/veterinaria
2.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(2): 343-350, 2023 Apr 18.
Artículo en Zh | MEDLINE | ID: mdl-37042148

RESUMEN

OBJECTIVE: To quantitatively evaluate the trueness of five chairside three-dimensional facial scanning techniques, and to provide reference for the application of oral clinical diagnosis and treatment. METHODS: The three-dimensional facial data of the subjects were collected by the traditional professional three-dimensional facial scanner Face Scan, which was used as the reference data of this study. Four kinds of portable three-dimensional facial scanners (including Space Spider, LEO, EVA and DS-FScan) and iPhone Ⅹ mobile phone (Bellus3D facial scanning APP) were used to collect three-dimensional facial data from the subjects. In Geomagic Studio 2013 software, through data registration, deviation analysis and other functions, the overall three-dimensional deviation and facial partition three-dimensional deviation of the above five chairside three-dimensional facial scanning technologies were calculated, and their trueness performance evaluated. Scanning time was recorded during the scanning process, and the subject's comfort was scored by visual analogue scale(VAS). The scanning efficiency and patient acceptance of the five three-dimensional facial scanning techniques were evaluated. RESULTS: DS-FScan had the smallest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.334 mm and 0.329 mm, respectively. The iPhone Ⅹ mobile phone had the largest mean overall and mean partition three-dimensional deviation between the test data and the reference data, which were 0.483 mm and 0.497 mm, respectively. The detailed features of the three-dimensional facial data obtained by Space Spider were the best. The iPhone Ⅹ mobile phone had the highest scanning efficiency and the highest acceptance by the subject. The average scanning time of the iPhone Ⅹ mobile phone was 14 s, and the VAS score of the subjects' scanning comfort was 9 points. CONCLUSION: Among the five chairside three-dimensional face scanning technologies, the trueness of the scan data of the four portable devices had no significant difference, and they were all better than the iPhone Ⅹ mobile phone scan. The subject with the iPhone Ⅹ scanning technology had the best expe-rience.


Asunto(s)
Imagenología Tridimensional , Programas Informáticos , Modelos Dentales
3.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(1): 174-180, 2023 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-36718708

RESUMEN

OBJECTIVE: To explore an efficient and automatic method for determining the anatomical landmarks of three-dimensional(3D) mandibular data, and to preliminarily evaluate the performance of the method. METHODS: The CT data of 40 patients with normal craniofacial morphology were collected (among them, 30 cases were used to establish the 3D mandibular average model, and 10 cases were used as test datasets to validate the performance of this method in determining the mandibular landmarks), and the 3D mandibular data were reconstructed in Mimics software. Among the 40 cases of mandibular data after the 3D reconstruction, 30 cases that were more similar to the mean value of Chinese mandibular features were selected, and the size of the mandibular data of 30 cases was normalized based on the Procrustes analysis algorithm in MATLAB software. Then, in the Geomagic Wrap software, the 3D mandibular average shape model of the above 30 mandibular data was constructed. Through symmetry processing, curvature sampling, index marking and other processing procedures, a 3D mandible structured template with 18 996 semi-landmarks and 19 indexed mandibular anatomical landmarks were constructed. The open source non-rigid registration algorithm program Meshmonk was used to match the 3D mandible template constructed above with the tested patient's 3D mandible data through non-rigid deformation, and 19 anatomical landmark positions of the patient's 3D mandible data were obtained. The accuracy of the research method was evaluated by comparing the distance error of the landmarks manually marked by stomatological experts with the landmarks marked by the method of this research. RESULTS: The method of this study was applied to the data of 10 patients with normal mandibular morphology. The average distance error of 19 landmarks was 1.42 mm, of which the minimum errors were the apex of the coracoid process [right: (1.01±0.44) mm; left: (0.56±0.14) mm] and maximum errors were the anterior edge of the lowest point of anterior ramus [right: (2.52±0.95) mm; left: (2.57±1.10) mm], the average distance error of the midline landmarks was (1.15±0.60) mm, and the average distance error of the bilateral landmarks was (1.51±0.67) mm. CONCLUSION: The automatic determination method of 3D mandibular anatomical landmarks based on 3D mandibular average shape model and non-rigid registration algorithm established in this study can effectively improve the efficiency of automatic labeling of 3D mandibular data features. The automatic determination of anatomical landmarks can basically meet the needs of oral clinical applications, and the labeling effect of deformed mandible data needs to be further tested.


Asunto(s)
Imagenología Tridimensional , Mandíbula , Humanos , Imagenología Tridimensional/métodos , Mandíbula/diagnóstico por imagen , Programas Informáticos , Algoritmos , Puntos Anatómicos de Referencia/anatomía & histología
4.
Zhonghua Yi Xue Za Zhi ; 103(35): 2772-2777, 2023 Sep 19.
Artículo en Zh | MEDLINE | ID: mdl-37723051

RESUMEN

Objective: To explore the predictive value of cerebrospinal fluid melanin-concentrating hormone (MCH) combined with other related biomarkers in preoperative cognitive dysfunction of elderly patients. Methods: A total of 80 patients who underwent elective hip or knee replacement under intravertebral anesthesia in Chifeng Municipal Hospital, Inner Mongolia, from March to November 2022 were prospectively included, with 32 males and 48 females, and aged 65-85 (70.7±5.2) years old. According to the evaluation results of the Montreal Cognitive Assessment (MoCA), patients were divided into the preoperative cognitive dysfunction (n=23) and control (n=57) groups. The levels of MCH, amyloid-ß 40 (Aß40), amyloid-ß 42 (Aß42), and phosphorylated tau protein (p-tau) in cerebrospinal fluid were determined by enzyme-linked immunosorbent assay (ELISA). The receiver operating characteristic (ROC) curve was drawn to evaluate the predictive value of each biomarker separately or in combination for preoperative cognitive dysfunction. Spearman's rank correlation analysis was utilized to test the correlation between the level of each biomarker and MoCA scores. Results: The levels of MCH, Aß40, Aß42, p-tau, and Aß42/p-tau in the preoperative cognitive dysfunction group were (35.53±5.94) µg/L, (39.21±9.18) ng/L, (221.83±43.17) ng/L, (42.64±9.74) ng/L, and 5.53±1.92, and the levels of these biomarkers in the control group were (28.74±4.90) µg/L, (36.37±7.87) ng/L, (280.23±45.67) ng/L, (35.00±9.27) ng/L, and 8.62±2.78, respectively. Compared with the control group, the levels of cerebrospinal fluid MCH and p-tau in the preoperative cognitive dysfunction group were significantly increased (all P<0.01), and the levels of Aß42 and Aß42/p-tau were significantly decreased (all P<0.001). MCH and Aß42/p-tau provided higher predictive values. The area under the curve (AUC) of MCH and Aß42/p-tau were 0.807 (95%CI: 0.703-0.911) and 0.842 (95%CI: 0.741-0.943), the sensitivity were 78.3% and 87.0%, and the specificity were 75.4% and 94.7%. MCH combined with Aß42/p-tau have the higher AUC of 0.915 (95%CI: 0.837-0.992), the sensitivity (87.0%) and specificity (86.0%) were both high, which had a higher predictive value. The levels of cerebrospinal fluid MCH and p-tau were negatively correlated with MoCA score (r=-0.467, -0.321, all P<0.01), and the levels of Aß42 and Aß42/p-tau were positively correlated with MoCA score (r=0.480, 0.520, all P<0.001). Conclusion: The increase in cerebrospinal fluid MCH levels is associated with preoperative cognitive dysfunction in elderly patients. MCH combined with Aß42/p-tau has the greatest predictive value.


Asunto(s)
Anestesia , Disfunción Cognitiva , Anciano , Femenino , Humanos , Masculino , Péptidos beta-Amiloides , Biomarcadores , Anciano de 80 o más Años
5.
Zhonghua Yu Fang Yi Xue Za Zhi ; 57(8): 1135-1140, 2023 Aug 06.
Artículo en Zh | MEDLINE | ID: mdl-37574302

RESUMEN

Objective: To analyze the mortality trend and characteristics of chronic obstructive pulmonary disease (COPD) among residents in China from 2004 to 2020. Methods: From the area, gender, region, and age dimensions, the Joinpoint regression model was used to analyze the trend of COPD mortality rate from 2004 to 2020, extracted from the China Death Surveillance Dataset. Results: From 2004 to 2020, the mortality rate and age-adjusted mortality rate of COPD showed a downward trend (AAPC=-3.68%, P<0.001; AAPC=-7.27%, P<0.001), which were consistent with urban and rural subpopulations (mortality rate: AAPC=-3.62%, P=0.009, AAPC=-3.23%, P=0.014; age-adjusted mortality rate: AAPC=-7.26%, P<0.001, AAPC=-6.78%, P<0.001). The mortality rate of COPD in rural was higher than that of urban subpopulations (P<0.001). Also, the mortality rate and age-adjusted mortality rate of COPD showed a downward trend in males and females (mortality rate: AAPC=-3.00%, P<0.001, AAPC=-4.37%, P<0.001; age-adjusted mortality rate: AAPC=-6.73%, P<0.001, AAPC=-8.11%, P<0.001), and the COPD mortality rate for male was generally higher than female (P<0.001). Meanwhile, the mortality rate of COPD in eastern, central and western regions also showed a downward trend (AAPC=-3.87%, P<0.001; AAPC=-3.12%, P<0.001; AAPC=-1.37%, P=0.001), and western regions were significantly higher than that in central (P<0.001) and eastern (P<0.001) regions. The mortality rate of COPD in the age group of Chinese people showed a downward trend in<45, 45-59, and≥60 years groups (AAPC=-9.48%, P<0.001; AAPC=-9.03%, P<0.001; AAPC=-5.91%, P<0.001). Among them,≥60 years groups was significantly higher than that in<45 (P<0.001) and 45-59 (P<0.001) years groups, and the decline rate was slowest. Conclusion: In China, the mortality rate of COPD decreases from 2004 to 2020, and more efforts are needed to reduce COPD mortality, especially in western regions, rural populations, males and the elderly.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pueblo Asiatico , China/epidemiología , Mortalidad , Población Rural , Población Urbana , Adulto
6.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(2): 327-334, 2022 Apr 18.
Artículo en Zh | MEDLINE | ID: mdl-35435200

RESUMEN

OBJECTIVE: To explore the construction process of the digital reference crown models, and to initially establish the digital reference crown models of the primary teeth to lay the foundation for the establishment of the standardized crown models and the future related applications of computer-aided design/computer-aided manufacture (CAD/CAM) technology to pediatric dentistry. METHODS: This study randomly selected children who were caries free, aged from 4 to 5 years in several kindergartens of Haidian District of Beijing.Plaster dental models were made for the children after taking complete impressions.The digital dental models were reconstructed by using the three-dimensional (3D) dental model scanner.And then, Geomagic Studio, a 3D reverse engineering software, was employed to extract the single dental crown data, the mesiodistal and buccolingual diameters and the height of the crowns were measured.The object was reduced or enlarged by a numerical factor, and then the size of each dental crown was standardized.A total of 3-5 points features on the crown were created, and all the objects were aligned through the functions of feature-based alignment.Finally, through average-based object creation and smoothing, the digital models of reference crowns of the primary teeth were established. RESULTS: A total of 40 plaster dental models from 16 boys and 26 girls were selected out for our further study.The digital dental models were reconstructed, and the mesiodistal and buccolingual diameters and the height of the crowns were measured by using reverse engineering technology.Comparing the results of using mesiodistal diameter, buccolingual diameter and height as the standards, we chose the mesiodistal diameters of crowns to do the standardization, and successfully established the digital reference models of 20 primary teeth crowns with detailed surface characteristics. CONCLUSION: In this study, the digital reference crown models of the primary teeth were established by reverse engineering technology, providing reference value for the standardized crown models and application for clinical practice, scientific research and teaching.Furthermore, this study also contributes to the extensive application of CAD/CAM technology in pediatric dentistry and the development of CAD/CAM dental systems with independent intellectual property rights.


Asunto(s)
Diseño Asistido por Computadora , Corona del Diente , Niño , Coronas , Diseño de Prótesis Dental , Femenino , Humanos , Masculino , Programas Informáticos , Diente Primario
7.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 146-152, 2022 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-35165482

RESUMEN

OBJECTIVE: To evaluate the accuracy of trephine bur drilling at different depths guided by dynamic navigation system in 3D printing in vitro model. METHODS: A model at the depth of 5 mm, 10 mm, and 15 mm from the outer surface of which hemispherical cavities was reserved and the 3D printing technology was used to make the standardized model with Veroclear resin. The cone beam CT (CBCT) was taken and the data were imported into the dynamic navigation software (DCARER, China) to establish navigation path programming. Under the guidance of dynamic navigation, a trephine bur with a diameter of 4.5 mm was used to complete the access operation. At each depth, 10 approaches were completed. The postoperative model CBCT was taken. The approach trajectory under navigation was reconstructed and compared with the designed path. The two-dimensional distance deviation, depth deviation, three-dimensional distance deviation, and angle deviation between the actually prepared path and the designed path were calculated. RESULTS: At the depth of 5 mm, the two-dimensional distance deviation between the end position of the prepared path and the designed path was (0.37±0.06) mm, the depth deviation was (0.06±0.05) mm, the three-dimensional distance deviation was (0.38±0.07) mm, and the angle deviation was 2.46°±0.54°; At the depth of 10 mm, the four deviations between the end position of prepared path and the designed path were (0.44±0.05) mm, (0.16±0.06) mm, (0.47±0.05) mm, and 2.45°±1.21°, respectively; At the depth of 15 mm, the four deviations were (0.52±0.14) mm, (0.16±0.07) mm, (0.55±0.15) mm, and 3.25°±1.22°, respectively. With the increase of entry depth, the three-dimensional and depth accuracy of dynamic navigation system decreased (P < 0.01), and the positioning angle deviation had no relation with the entry depth (P>0.01). CONCLUSION: Dynamic navigation technology can achieve high positioning accuracy in the depth range of 15 mm, but its deviation increases with the increase of entry depth.


Asunto(s)
Cirugía Asistida por Computador , China , Tomografía Computarizada de Haz Cónico , Impresión Tridimensional
8.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(4): 719-726, 2022 Aug 18.
Artículo en Zh | MEDLINE | ID: mdl-35950398

RESUMEN

OBJECTIVE: To explore the method of measuring root volume with cone-beam computed tomography (CBCT) three-dimensional reconstruction technology, and to study root length and root volume of upper and lower central incisors in patients with skeletal Class Ⅲ malocclusion treated by surgical orthodontic treatment. METHODS: Twenty patients with skeletal Class Ⅲ malocclusion undergoing surgical orthodontic treatment were selected. CBCT data at three time points, before decompensation treatment (T0), after decompensation treatment (before orthognathic surgery, T1), and the end of post-operative orthodontic treatment (T2) were collected. Three-dimensional reconstruction technology was used to measure the root length and root volume of the upper and lower central incisors (including total root volume, cervical root and apical root), calculate the percentage of reduction volume, and measure the distance of tooth movement after orthodontic treatment. Data were statistically analyzed by SPSS 20.0 software. Least significant difference (LSD) method was used for pair comparison between the groups subject to normal distribution, and non-parametric test was used for comparison between the groups not subject to normal distribution. The differences of root length and root volume of upper and lower incisors were compared, and the characteristics of root absorption were analyzed. RESULTS: Root length and root volume of the upper and lower central incisors were reduced during the surgical orthodontic treatment (P < 0.05) in cases. Both the root volume of cervical root and apical root were significantly reduced (P < 0.05), the reduction of apical root was more significant. The percentage of root volume reduction of the upper central incisor was (30.51±23.23)%, and lower central incisor (23.24±11.96)%. Compared with the upper central incisor, the root volume reduction amount and percentage of the lower central incisor were smaller, and apical root volume reduction of the upper central incisor was greater than that of the lower central incisor, which was statistically significant (P < 0.05). During pre-surgical orthodontic treatment, maxillary central incisor palatal moving was in a controlled tipping manner, and the mandibular central incisor tipped labially. CONCLUSION: In patients with skeletal Class Ⅲ malocclusion, root length and total root volume of upper and lower central incisors decreased during surgical orthodontic treatment. Root volume measurement indicated that the cervical root also had root resorption. The difference in root resorption of the upper and lower central incisors might be related to the distance and direction of teeth movement. CBCT three-dimensional reconstruction will compensate for the limitation of root length measurement in evaluating root resorption.


Asunto(s)
Maloclusión de Angle Clase III , Resorción Radicular , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Incisivo/diagnóstico por imagen , Maloclusión de Angle Clase III/cirugía , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Resorción Radicular/diagnóstico por imagen , Resorción Radicular/etiología
9.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 134-139, 2022 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-35165480

RESUMEN

OBJECTIVE: To establish a deep learning algorithm that can accurately determine three-dimensional facial anatomical landmarks, multi-view stacked hourglass convolutional neural networks (MSH-CNN) and to construct three-dimensional facial midsagittal plane automatically based on MSH-CNN and weighted Procrustes analysis algorithm. METHODS: One hundred subjects with no obvious facial deformity were collected in our oral clinic. Three-dimensional facial data were scanned by three-dimensional facial scanner. Experts annotated twenty-one facial landmarks and midsagittal plane of each data. Eighty three-dimensional facial data were used as training set, to train the MSH-CNN in this study. The overview of MSH-CNN network architecture contained multi-view rendering and training the MSH-CNN network. The three-dimensional facial data were rendered from ninety-six views that were fed to MSH-CNN and the output was one heatmap per landmark. The result of the twenty-one landmarks was accurately placed on the three-dimensional facial data after a three-dimensional view ray voting process. The remaining twenty three-dimensional facial data were used as test set. The trained MSH-CNN automatically determined twenty-one three-dimensional facial anatomical landmarks of each case of data, and calculated the distance between each MSH-CNN landmark and the expert landmark, which was defined as position error. The midsagittal plane of the twenty subjects' could be automatically constructed, using the MSH-CNN and Procrustes analysis algorithm. To evaluate the effect of midsagittal plane by automatic method, the angle between the midsagittal plane constructed by the automatic method and the expert annotated plane was calculated, which was defined as angle error. RESULTS: For twenty subjects with no obvious facial deformity, the average angle error of the midsagittal plane constructed by MSH-CNN and weighted Procrustes analysis algorithm was 0.73°±0.50°, in which the average position error of the twenty-one facial landmarks automatically determined by MSH-CNN was (1.13±0.24) mm, the maximum position error of the orbital area was (1.31±0.54) mm, and the minimum position error of the nasal area was (0.79±0.36) mm. CONCLUSION: This research combines deep learning algorithms and Procrustes analysis algorithms to realize the fully automated construction of the three-dimensional midsagittal plane, which initially achieves the construction effect of clinical experts. The obtained results constituted the basis for the independent intellectual property software development.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Cara , Humanos , Redes Neurales de la Computación , Programas Informáticos
10.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 193-199, 2022 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-35165490

RESUMEN

OBJECTIVE: To automatically construct lips symmetry reference plane (SRP) based on posed smile, and to evaluate its advantages over conventional digital aesthetic design. METHODS: Eighteen subjects' three-dimensional facial and dentition data were gathered in this study. The lips SRP of experimental groups were used with the standard weighted Procrustes analysis (WPA) algorithm and iterative closest point (ICP), respectively. A reference plane defined by experts based on regional ICP algorithm, served as the truth plane. The angle error values between the lips SRP of WPA algorithm in the experimental groups and the truth plane were evaluated in this study, and the lips SRP of ICP algorithm of the experimental groups was calculated in the same way. The lips SRP based on posed smile as a reference for aesthetic design and evaluate preliminary clinical application. RESULTS: The average angle error between the lips SRP of WPA algorithm and the truth plane was 1.78°±1.24°, which was smaller than that between the lips SRP of ICP and the truth plane 7.41°±4.31°. There were significant differences in the angle errors among the groups (P < 0.05). In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile and the original symmetry plane by re-ference compared with the prosthetic design, the subjects' scores on the lips SRP of WPA algorithm based on posed smile (8.48±0.57) were higher than those on the original symmetry plane (5.20±1.31). CONCLUSION: Automatically constructing the lips SRP of WPA algorithm based on posed smile was more accurate than ICP algorithm, which was consistent with the truth plane. Moreover, it can provide an important reference for oral aesthetic diagnosis and aesthetic analysis of the restoration effect. In the aesthetic design of anterior teeth, automatically constructing the lips SRP of WPA algorithm based on posed smile can improve the patients' satisfaction in esthetic rehabilitation.


Asunto(s)
Labio , Diente , Estética Dental , Humanos , Sonrisa , Flujo de Trabajo
11.
Zhonghua Yi Xue Za Zhi ; 101(34): 2710-2716, 2021 Sep 14.
Artículo en Zh | MEDLINE | ID: mdl-34510878

RESUMEN

Objective: To analyze the clinical characteristics of chronic total coronary occlusion (CTO) combined with bifurcation lesions and the features of coronary intervention and perioperative complications. Methods: This study adopted retrospective cross-sectional research methods and included 673 patients who underwent interventional therapy for chronic total occlusion in Beijing Anzhen Hospital. According to whether there were side branches (diameter ≥2 mm) within 5 mm before and after the CTO occlusion segment, patients were divided into bifurcation group (337 cases) and non-bifurcation group (336 cases). The measurement data did not conform to the normal distribution and were represented as M (Q1, Q3). The clinical risk factors, coronary angiography characteristics, interventional treatment strategies and perioperative complications were compared between the two groups. Results: The patients in the bifurcation group were 60 (51, 65) years old, and 86.6% (292 cases) were male; the patients in the non-bifurcation group were 60 (52, 66) years old, and 83.0% (279 cases) were male.Coronary artery disease in all patients was mainly multivessel disease, of which three-vessel disease accounted for 59.9% (403 cases) and double-vessel disease accounted for 25.4% (171 cases).The target vessel in the bifurcation group was predominantly left anterior descending artery (62.3%, 210 cases), and the target vessel in the non-bifurcation group was more common in the right coronary artery (56%, 188 cases). The target vessel diameter was larger in the bifurcation group (2.91(2.71, 3.24) mm vs 2.80(2.55, 3.13) mm, P<0.001). Most patients used the antegrade technique (88%, 592 cases), and the use of antegrade technique in the bifurcation group (91.9%, 307 cases) was higher than that in the non-bifurcation group (84.8%, 285 cases) (P=0.012). After CTO-PCI, 72.8% (490 cases) of patients achieved successful angiography. A total of 73 patients (10.8%) had perioperative complications, and there was no statistical difference between the two groups. However, the incidence of perioperative myocardial infarction was higher in the bifurcation group (5.9%, 20 cases) than non-bifurcation group (2.7%, 9 cases) (P=0.038). Conclusions: CTO complicated with bifurcation lesions are very common in clinical practice. Most patients with CTO have multiple coronary artery disease at the same time. The target vessel is more common in the left anterior descending artery, and the diameter of the vessel is larger. It is more common to use antergrade technique, accompanied by more perioperative myocardial infarctions.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Anciano , Enfermedad Crónica , Angiografía Coronaria , Estudios Transversales , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
12.
Br J Surg ; 107(3): 248-257, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31971627

RESUMEN

BACKGROUND: The prognostic values of the AJCC staging system for gastric cancer (GC-AJCC), the AJCC staging system for gastric neuroendocrine tumours (NET-AJCC) and the European Neuroendocrine Tumor Society (ENETS) system for gastric neuroendocrine carcinoma and mixed adenoneuroendocrine carcinoma (MA)NEC remain controversial. METHODS: Data on patients with (MA)NEC from 21 centres in China were analysed. Different staging systems were evaluated by performing Kaplan-Meier survival analysis and calculating the concordance index (C-index) and Akaike information criterion (AIC). Based on three existing systems, a modified staging system (mTNM) was developed. RESULTS: A total of 871 patients were included. In the GC-AJCC system, an overlap was noticed for pT2 and pT3 categories. Patients with stage IIIC disease had a similar prognosis to those with stage IV disease. The pT categories of the NET-AJCC system had a lower C-index and higher AIC than those of the other systems. In the ENETS system, there was a low proportion (0·2 per cent) of patients with stage IIIA and a high proportion (67·6 per cent) of stage IIIB disease. The mTNM system adopted the NET-AJCC pT and GC-AJCC pN and pM definitions, and was developed based on the ENETS stage definitions. The proportion of patients in each stage was better distributed and the mTNM system showed improved prognostic performance in predicting overall and disease-free survival. CONCLUSION: The mTNM system offers more accurate prognostic value for gastric (MA)NEC than the AJCC or ENETS staging systems.


Asunto(s)
Carcinoma Neuroendocrino/diagnóstico , Oncología Médica , Estadificación de Neoplasias/métodos , Sociedades Médicas , Neoplasias Gástricas/diagnóstico , Supervivencia sin Enfermedad , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Estados Unidos
13.
Br J Surg ; 107(9): 1163-1170, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32323879

RESUMEN

BACKGROUND: The aim of this study was to evaluate whether adjuvant chemotherapy is associated with improved survival in patients with resectable gastric neuroendocrine carcinomas (G-NECs) or mixed adenoneuroendocrine carcinomas (G-MANECs). METHODS: The study included patients with G-NECs or G-MANECs who underwent surgery in one of 21 centres in China between 2004 and 2016. Propensity score matching analysis was used to reduce selection bias, and overall survival (OS) in different treatment groups was estimated by the Kaplan-Meier method. RESULTS: In total, 804 patients with resectable G-NECs or G-MANECs were included, of whom 490 (60·9 per cent) received adjuvant chemotherapy. After propensity score matching, OS in the chemotherapy group was similar to that in the no-chemotherapy group. Among patients with G-NECs, survival in the fluorouracil (5-FU)-based chemotherapy group and the non-5-FU-based chemotherapy group was similar to that in the no-chemotherapy group. Similarly, etoposide plus cisplatin or irinotecan plus cisplatin was not associated with better OS in patients with G-NECs. Among patients with G-MANECs, OS in the non-5-FU-based chemotherapy group was worse than that in the no-chemotherapy group. Patients with G-MANECs did not have better OS when platinum-based chemotherapy was used. CONCLUSION: There was no survival benefit in patients who received adjuvant chemotherapy for G-NECs or G-MANECs.


ANTECEDENTES: El objetivo de este estudio fue evaluar si la quimioterapia adyuvante mejoraba la supervivencia en pacientes con carcinomas gástricos resecables neuroendocrinos (gastric neuroendocrine carcinomas, G-NECs) y carcinomas adenoneuroendocrinos mixtos (mixed adenoneuroendocrine carcinomas, G-MANECs). MÉTODOS: Se incluyeron pacientes con G-NECs y G-MANECs tratados quirúrgicamente en 21 centros en China entre 2004 y 2016. Se utilizó un análisis de emparejamiento por puntaje de propensión para reducir el sesgo de selección y el método de Kaplan-Meier para estimar la supervivencia global (overall survival, OS) de los pacientes en los diferentes grupos de tratamiento. RESULTADOS: En total, se incluyeron en el estudio 804 pacientes con G-NECs y G-MANECs resecables y 490 pacientes (60,9%) recibieron quimioterapia adyuvante. Después del emparejamiento por puntaje de propensión, la OS del grupo con quimioterapia fue similar a la del grupo sin quimioterapia. En los pacientes con G-NECs, la supervivencia en los grupos con quimioterapia basada en 5-FU (fluorouracilo) y de quimioterapia sin 5-FU fue similar a la del grupo sin quimioterapia. Asimismo, la combinación de etopósido y cisplatino o de irinotecán y cisplatino no se asoció con una mejor OS en pacientes con G-NECs. En pacientes con G-MANECs, la OS del grupo con quimioterapia sin 5-FU fue peor que la del grupo sin quimioterapia. Los pacientes con G-MANECs no presentaron una mejor OS cuando se administró quimioterapia basada en platinos. CONCLUSIÓN: La administración de quimioterapia adyuvante en pacientes con G-NECs y G-MANECs no mejoró la supervivencia.


Asunto(s)
Carcinoma Neuroendocrino/tratamiento farmacológico , Quimioterapia Adyuvante , Neoplasias Gástricas/tratamiento farmacológico , Anciano , Antimetabolitos Antineoplásicos/uso terapéutico , Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Carcinoma Neuroendocrino/mortalidad , Carcinoma Neuroendocrino/cirugía , Quimioterapia Adyuvante/métodos , Quimioterapia Adyuvante/mortalidad , Cisplatino/administración & dosificación , Cisplatino/uso terapéutico , Etopósido/administración & dosificación , Etopósido/uso terapéutico , Femenino , Fluorouracilo/uso terapéutico , Humanos , Irinotecán/administración & dosificación , Irinotecán/uso terapéutico , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Neoplasias Gástricas/mortalidad , Neoplasias Gástricas/cirugía , Análisis de Supervivencia
14.
Phys Rev Lett ; 124(10): 105303, 2020 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-32216438

RESUMEN

Weyl points are often believed to appear in pairs with opposite chirality. In this work, we show by first-principles calculations and symmetry analysis that single Weyl phonons with linear dispersion and double Weyl phonons with quadratic dispersion are simultaneously present between two specific phonon branches in realistic materials with trigonal or hexagonal lattices. These phonon Weyl points are guaranteed to locate at high-symmetry points due to the screw rotational symmetry, forming a unique triangular Weyl complex. In sharp contrast to conventional Weyl systems with surface arcs terminated at the projections of a pair of Weyl points with opposite chirality, the phonon surface arcs of the unconventional triangular Weyl complex connect the projections of one double Weyl point and two single Weyl points. Importantly, the phonon surface arcs originating from the triangular Weyl complex are extremely long and span the entire surface Brillouin zone. Furthermore, there are only nontrivial phonon surface states across the isofrequency surface, which facilitates their detection in experiments and further applications. Our work not only offers the promising triangular phonon Weyl complex but also provides guidance for exploring triangular Weyl bosons in both phononic and photonic systems.

15.
J Biol Regul Homeost Agents ; 34(3): 953-960, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32696626

RESUMEN

This study aims to investigate the role of PM2.5 exposure in inducing apoptosis of alveolar epithelial cells and thereafter emphysema in mice, and the underlying mechanism. PM2.5 exposure model in mice was constructed. Lung tissues were harvested from healthy mice and model mice for hematoxylin and eosin (H&E) staining. Protein levels of Forkhead box O3 (FOXO3A) and BIM in lung tissues were detected by Western blot. Subsequently, A549 cells were induced with increased doses of PM2.5, followed by determination of relative levels of FOXO3A, BIM (Bcl-2 interacting mediator of cell death) and clv-caspase3. Apoptosis in PM2.5-exposed A549 cells was assessed. Chromatin immunoprecipitation (ChIP) assay was conducted to uncover the interaction between FOXO3A and BIM. Finally, regulatory effects of FOXO3A/BIM on apoptosis of A549 cells were determined. PM2.5 exposure resulted in expansion of alveolar spatial structure and decline of lung function, thus leading to emphysema in mice. Protein levels of FOXO3A and BIM were markedly upregulated in lungs of model mice. Relative levels of FOXO3A, BIM and clv-caspase3 were enhanced in PM2.5 -exposed A549 cells, which were reversed by transfection of si-FOXO3A. ChIP assay confirmed that FOXO3A was able to regulate BIM transcription through binding its promoter regions. Importantly, regulatory effects of FOXO3A on apoptosis of PM2.5 -exposed A549 cells were partially reversed by overexpression of BIM. PM2.5 exposure leads to upregulation of FOXO3A, which triggers BIM transcription, thus inducing apoptosis of alveolar epithelial cells and emphysema in mice.


Asunto(s)
Proteínas Reguladoras de la Apoptosis , Enfisema , Animales , Apoptosis , Proteínas Reguladoras de la Apoptosis/genética , Proteína 11 Similar a Bcl2 , Proteína Forkhead Box O3 , Ratones , Material Particulado/toxicidad
16.
Neoplasma ; 67(6): 1359-1366, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32787437

RESUMEN

The predictors for the prognosis of gastric cancer (GC) are not clear. We intended to explore the role of PTEN and microsatellite (MS) in GC, showing their potential as prognostic markers. Primary gastric cancer tissues, adjacent normal tissues, and clinicopathological parameters of 187 patients were collected. The expression level of PTEN and MS status were classified by immunohistochemistry (IHC). The relationship among indicators was compared by the chi-square test. The survival curves were delineated by Kaplan-Meier and tested by Log-rank methods. The impact of multiple factors on prognosis was determined by COX proportional hazards model. Significantly, PTEN expression was associated with lymphatic invasion (p=0.011) and Lauren grade (p=0.015). MS status was associated with differentiation (p=0.006) and Lauren grades (p=0.035). TNM stage was associated with MS status under positive PTEN expression (p=0.014). Patients with microsatellite stability (MSS) had worse median overall survival (OS) than that with microsatellite instability (MSI) (p=0.013). Patients with negative PTEN expression had a worse median OS than that with positive PTEN expression (p<0.001). The tumor subtype of PTEN negative-MSS (p<0.001) and PTEN negative-MSI (p=0.042) were strong predictors of poor survival. Negative PTEN expression and MSS might lead to unfavorable prognosis due to their association with clinicopathological parameters of GC. PTEN expression and MS status could be predictors for the prognosis of GC.


Asunto(s)
Inestabilidad de Microsatélites , Fosfohidrolasa PTEN/genética , Neoplasias Gástricas , Biomarcadores de Tumor/genética , Humanos , Repeticiones de Microsatélite , Estadificación de Neoplasias , Pronóstico , Neoplasias Gástricas/genética , Neoplasias Gástricas/patología
17.
Zhonghua Zhong Liu Za Zhi ; 42(11): 919-924, 2020 Nov 23.
Artículo en Zh | MEDLINE | ID: mdl-33256302

RESUMEN

Objective: To explore the effect and mechanism of peroxiredoxin1 (PRDX1) in epithelial mesenchymal transformation (EMT) of gastric cancer cells. Methods: The expression of PRDX1 protein was detected by immunohistochemistry (IHC) in 70 paraffin specimens of cancer and normal mucosa adjacent to gastric cancer, and the relationship between PRDX1 protein and clinicopathological characteristics was analyzed. Then PRDX1-small interfering RNA (siRNA) was synthetized and transfected into human gastric cancer cell line AGS, and 3-(4, 5-dimethyl-2-thiazolyl)-2, 5-diphenyl-2H tetrazolium bromide (MTT) assay was used to test cell proliferation. Transwell chamber assay was employed to test invasion of cells. Real-time quantitative polymerase chain reaction (RT-qPCR) and western blot were utilized to test the expressions of PRDX1, E-cadherin, N-cadherin, vimentin, and claudin-1. Results: The positive rate of PRDX1 protein expression in gastric cancer was 81.4%, higher than that in normal mucosa (27.1%, P<0.05). The expression of PRDX1 protein was related to invasive depth and lymph node metastasis of gastric cancer (P<0.05). The expressions of PRDX1 mRNA and protein in AGS cells (2.216±0.445, 1.212±0.136), were higher than those in GES-1 cells (0.342±0.041, 0.328±0.038) (P<0.05). When PRDX1-siRNA was transfected into AGS cells, the proliferation of AGS cells was significantly inhibited (all P<0.05). The invasion and migration rate of AGS cells in the transfection group [(112.00±17.98), (50.87±9.79)%] were significantly lower than those of the negative control group [(192.50±22.02), (83.03±8.67)%] and blank control group [(193.83±22.40), (82.40±7.21)%] (all P<0.05). The expressions of mRNA and protein of N-cadherin, vimentin and claudin-1 decreased, while the expression of E-cadherin increased when PRDX1-siRNA was transfected into AGS cells (P<0.05). Conclusion: PRDX1 may promote the development of gastric cancer by regulating the EMT of gastric cancer cells.


Asunto(s)
Transición Epitelial-Mesenquimal , Peroxirredoxinas , Neoplasias Gástricas , Proliferación Celular/genética , Transición Epitelial-Mesenquimal/genética , Regulación Neoplásica de la Expresión Génica , Humanos , Peroxirredoxinas/genética , Peroxirredoxinas/metabolismo , ARN Mensajero/metabolismo , Neoplasias Gástricas/genética , Neoplasias Gástricas/metabolismo
18.
Beijing Da Xue Xue Bao Yi Xue Ban ; 52(1): 144-151, 2020 Feb 18.
Artículo en Zh | MEDLINE | ID: mdl-32071478

RESUMEN

OBJECTIVE: To analyze the distribution and area of occlusal contacts of clinical dental model using three kinds of digital analysis methods, to compare the results of these methods and traditional occlusal analysis method, and to further analyze the characteristics of each digital analysis method. METHODS: A set of plaster models of normal subjects was selected. The models were scanned by lab scanner 3shape E4 and the files were exported in a stereolithography file format. In 3D analysis software Geomagic Studio 2013 and Geomagic Qualify 2013, the corresponding results of 3D occlusal contact distribution and occlusal contact area were obtained through three digital analysis methods: "3D color difference map method", "point cloud analysis method", and "virtual articulating paper method". The occlusal contact distribution and occlusal contact area were also obtained by two traditional occlusal analysis methods: "silicone interocclusal recording material method" and "scanned articulating paper mark method". A threshold of 100 µm was used to analyze the occlusal contacts and 100 µm was also the thickness of articulating paper used in this study. The results of these five different occlusal analysis methods were evaluated qualitatively and quantitatively. RESULTS: The results of 3D occlusal contact distribution obtained by the above five methods were basically consistent. The total occlusal contact area obtained by 3D color difference map method, point cloud analysis method, virtual articulating paper method, silicone interocclusal recording material method and scanned articulating paper mark method were 133.10 mm², 142.08 mm², 128.95 mm², 163.31 mm², and 100.55 mm² respectively. There was little difference between the results of three digital analysis methods. The results of occlusal contact area obtained by the digital methods and the traditional methods were different. CONCLUSION: The three digital analysis methods can provide reliable and accurate analysis results of occlusal contact distribution and occlusal contact area of dental model. The results obtained by these methods can serve as references for the digital occlusal surface design of dental prosthesis and clinical occlusal analysis.


Asunto(s)
Modelos Dentales , Programas Informáticos , Imagenología Tridimensional
19.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(1): 54-61, 2020 Dec 18.
Artículo en Zh | MEDLINE | ID: mdl-33550336

RESUMEN

OBJECTIVE: To establish a method for the production of digital individual tooth tray based on three-dimensional (3D) scan, computer-aided design (CAD) and 3D printing, and to evaluate the effect of impression taking of full-arch crown abutments by digital individual tooth tray technique and conventional method through in vitro study. METHODS: The full crown preparation was performed on all the fourteen resin teeth in a standard model of mandibular dentition. The surface data of prepared abutments was collected by 3D scanning. A new project was created in a dental CAD software including all the fourteen teeth in the mandibular dentition. The design modules of anatomy crown and coping were selected for each tooth. The dentition was divided for three sections: right posterior teeth, anterior teeth, and left posterior teeth areas. The connector design was added between the abutments within the same section. The scanned data of the abutments were imported. The occlusal plane and insertion path were determined. The position of margin line, as well as the shape of anatomy crown and connector as the main body of the individual tooth tray were designed for each abutment. The shape of coping was generated as the space for holding the impression material. The finalized data of the main body was imported into Geomagic software. The retentive attachment was added at the external surface and the tissue stop was formed at the internal surface. The completed individual tooth tray was manufactured by 3D printing with resin material. The data of full-arch crown abutments were modified and printed. The conventional dentition trays A and B, as well as digital individual tooth tray were designed and printed for four copies each. The polyether impressions of the full-arch abutments were made by conventional one-step method using dentition tray A, and by sectional-impression technique using digital individual tooth tray and dentition tray B for four times each. The time spent for each impression taking and the numbers of defects at the shoulder and axial/occlusal surface in each impression were recorded. The impression quality of each abutment was evaluated. The overall quality distribution and the pass rate of abutments between the two methods were analyzed. RESULTS: The impressions made by conventional method had more defects at shoulder than those made by digital individual tooth tray technique. No difference of the number of defects at axial/occlusal surface between the two methods was observed. The digital individual tooth tray technique for the full-arch abutment impression exhibited higher pass rate of abutments and better quality of impression, compared with conventional methods. CONCLUSION: A new method for the production of digital individual tooth tray based on digital scanning, CAD and 3D printing was established. Compared with conventional method, using digital individual tooth tray technique for impression taking of full-arch abutments can achieve better effect.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Materiales de Impresión Dental , Técnica de Impresión Dental , Modelos Dentales , Impresión Tridimensional , Programas Informáticos
20.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(1): 95-101, 2020 Dec 24.
Artículo en Zh | MEDLINE | ID: mdl-33550342

RESUMEN

OBJECTIVE: To investigate the change of endo-sinus bone height and bone volume in osteotome sinus floor elevation (OSFE) without bone graft but placing implants simultaneously by using cone beam computed tomography (CBCT) and three dimensional analysis, and to find the impacting factors on endo-sinus bone augmentation. METHODS: OSFE was performed in 38 edentulous patients with missing teeth at posterior maxillary region, and 44 implants were placed and referred for OSFE using no graft materials. CBCT was performed pre-surgery and 9-68 months post-surgery when the patients encountered another implant surgery. The gained bone height at mesial, distal, buccal and palatal sites around the implant in sinus were measured, volumetric measurements of the endo-sinus gained bone volume (ESGBV) in the elevated region were calculated by Mimics software. Univariate analysis and multiple linear regression were performed to investigate the impacting factors on the gained bone height and ESGBV. Marginal bone loss was recorded according to the periapical radiography after implant restoration. RESULTS: The mean residual bone height (RBH) pre-surgery was (3.41±1.23) mm, the mean protruded length (PL) into sinus of implant post-surgery was (3.41±1.28) mm, the mean endo-sinus gained bone height was (2.44±1.23) mm at distal sites, (2.88±1.20) mm at mesial sites, (2.83±1.22) mm at buccal sites and (2.96±1.16) mm at palatal sites, the mean endo-sinus gained bone height at distal sites was significantly lower than the other three sites (P < 0.05). The average endo-sinus gained bone height was (2.78±1.13) mm. The mean ESGBV was (122.15± 73.27) mm3. Univariate analysis showed the more RBH, the less bone height gained in sinus, which existed at buccal, lingual, mesial and distal sites (P < 0.001), and the more RBH, the smaller ESGBV gained (P=0.012). The ESGBV was significantly higher in the subjects whose bone generation period was more than 24 months than those whose bone generation period less than 24 months (P=0.034). The more PL, the more bone height and ESGBV gained (P=0.008). Multivariate analysis showed after adjusting factors of gender, age, smoking, width of sinus floor, thickness of sinus membrane pre-surgery, diameter and length of the implant, PL and bone generation period was positively correlated with mean endo-sinus gained bone height and ESGBV, while RBH negatively correlated with mean endo-sinus gained bone height. During the follow-up, the mean marginal bone loss was 0 (0-1.41) mm and all the implants loaded successfully. CONCLUSION: OSFE without bone graft but with placed implant simultaneously can increase endo-sinus gained bone height and ESGBV. RBH, PL and bone generation period are the significant factors impacting endo-sinus bone augmentation.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Trasplante Óseo , Implantación Dental Endoósea , Humanos , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Osteotomía , Radiografía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda