Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
J Geriatr Cardiol ; 21(5): 506-522, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38948898

RESUMEN

OBJECTIVES: To investigate whether negative remodeling (NR) detected by intravascular ultrasound (IVUS) of the side branch ostium (SBO) would affect in-stent neointimal hyperplasia (NIH) at the one-year follow-up and the clinical outcome of target lesion failure (TLF) at the long-term follow-up for patients with left main bifurcation (LMb) lesions treated with a two-stent strategy. METHODS: A total of 328 patients with de novo true complex LMb lesions who underwent a 2-stent strategy of percutaneous coronary intervention (PCI) treatment guided by IVUS were enrolled in this study. We divided the study into two phases. Of all the patients, 48 patients who had complete IVUS detection pre- and post-PCI and at the 1-year follow-up were enrolled in phase I analysis, which aimed to analyze the correlation between NR and in-stent NIH at SBO at the 1-year follow-up. If the correlation was confirmed, the cutoff value of the remodeling index (RI) for predicting NIH ≥ 50% was analyzed next. The phase II analysis focused on the incidence of TLF as the primary endpoint at the 1- to 5-year follow-up for all 328 patients by grouping based on the cutoff value of RI. RESULTS: In phase I: according to the results of a binary logistic regression analysis and receiver operating characteristic (ROC) analysis, the RI cutoff value predicting percent NIH ≥ 50% was 0.85 based on the ROC curve analysis, with a sensitivity of 85.7%, a specificity of 88.3%, and an AUC of 0.893 (0.778, 1.000), P = 0.002. In phase II: the TLR rate (35.8% vs. 5.3%, P < 0.0001) was significantly higher in the several NR (sNR, defined as RI ≤ 0.85) group than in the non-sNR group. CONCLUSION: The NR of LCxO is associated with more in-stent NIH post-PCI for distal LMb lesions with a 2-stent strategy, and NR with RI ≤ 0.85 is linked to percent NIH area ≥ 50% at the 1-year follow-up and more TLF at the 5-year follow-up.

2.
Cardiol J ; 30(3): 353-360, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36200544

RESUMEN

BACKGROUND: Previous studies have established that moderately to severely calcified lesions (MSCL) are associated with high rates of major adverse cardiovascular events, even when drug-eluting stents are implanted after rotational atherectomy (RA). Yet, the changes in coronary function indexes during follow-ups have never been investigated. The quantitative flow ratio (QFR), a novel coronary function index, has been increasingly adopted in daily practice in recent years. METHODS: A total of 111 MSCL patients were retrospectively enrolled in this study. The vessel QFR (QFRv) loss was defined as post-percutaneous coronary intervention QFRv minus follow-up QFRv. The study subjects were divided into high QFRv loss (n = 51) and low QFRv loss (n = 60) groups according to the binary method. The obtained predictors of QFRv loss were then analyzed. RESULTS: The results showed that the final burr-to-vessel ratio (B to V ratio) in the high QFRv loss group decreased significantly compared to the low QFRv loss group (p < 0.01). The univariate and multivariate regression analyses indicated that the final B to V ratio was an excellent predictor of QFRv loss. The cut-off value of the final B to V ratio for QFRv loss prediction was 0.50 (sensitivity: 50.98%, specificity: 68.33%, and area under the curve: 0.627 [95% confidence interval: 0.530-0.717], p < 0.05). Additionally, the target vessel failure incidence in the high QFRv loss group was higher than in the low QFRv loss group (p < 0.01). CONCLUSIONS: An increased burr-to-vessel ratio can prevent QFRv loss in patients with MSCLs after RA, an effect that might be closely associated with a low target vessel failure incidence.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Calcificación Vascular , Humanos , Aterectomía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/cirugía , Angiografía Coronaria
3.
Int J Cardiovasc Imaging ; 39(3): 667-676, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36609638

RESUMEN

To explore the potential significance of the reverberation of calcification by comparing both intravascular ultrasound (IVUS) and optical coherence tomography (OCT) measurement post manual coregistration. The reverberation phenomenon is often detected by IVUS for severe calcified lesions post rotational atherectomy (RA), which is thought to be due to the glassy and smooth inner surfaces of calcifications. Because of the poor penetration of IVUS, it is impossible to measure the thickness of calcifications, and the relationship between multiple reverberations and the thickness of calcification lesions has not been reported before. A total of forty-nine patients with severe calcified coronary lesions that were detected by IVUS and OCT simultaneously were enrolled in our retrospective study. If reverberation phenomena were detected by IVUS, intravascular imaging (IVI) data (including distance between the IVUS catheter center and the inner surface of the reverberation signal, the intervals between all adjacent reverberation signals, the number of layers of reverberation in IVUS, and the thickness of the calcification in OCT) were measured at the same position and same direction (each cross-section had 4 mutually perpendicular directions) at 1-mm intervals. The correlation between each reverberation observational value and OCT data was the primary target in this retrospective study, and the correlation between reverberation and calcium crack post predilatation was analyzed in other 15 patients. Four hundred twenty-eight valid observational points were analyzed simultaneously by IVUS and OCT; among them, 300 points had a single layer of reverberation, 83 had double layers of reverberation and 42 had multiple layers (≥ 3 layers) of reverberation by IVUS detection post-RA. Multivariate logistic regression analysis showed that the number of layers of reverberation by IVUS was significantly related to the thickness of calcifications by OCT at the same point and in the same direction (p < 0.001). Single, double, and multiple layers of reverberation in IVUS correspond to median calcification thicknesses (interquartile ranges (IQRs)) of 0.620 mm (0.520-0.720), 0.950 mm (0.840-1.040) and 1.185 mm (1.068-1.373), respectively, by OCT detection. Another 100 points in other 15 patients with integrated IVUS data pre- and post-predilatation showed that only single layer of reverberation was related to calcium crack (p < 0.001). The number of layers of reverberation signal detected by IVUS is positively correlated with the thickness of calcifications measured by OCT post-RA and single layer of reverberation is correlated to calcium crack post-predilatation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Calcificación Vascular , Humanos , Enfermedad de la Arteria Coronaria/patología , Estudios Retrospectivos , Calcio , Ultrasonografía Intervencional , Valor Predictivo de las Pruebas , Vasos Coronarios/diagnóstico por imagen , Tomografía de Coherencia Óptica , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda