Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Zhonghua Yi Xue Za Zhi ; 90(21): 1503-6, 2010 Jun 01.
Artículo en Zh | MEDLINE | ID: mdl-20973226

RESUMEN

OBJECTIVE: To study the efficacy of polyporus composite phosphate calcium and rhBMP-2 compounds with laparoscopical lumbar interbody fusion in sheep. METHODS: Fourteen uniform-weight adult sheep were randomly divided into three groups for LA-5 interbody fusion with titanium mesh. Autogenous bone and titanium mesh was applied with open anterior technique in group 1 (n=4). In group 2, 4 sheep were operated with laparoscope technique for LA-5 interbody fusion with composite phosphate calcium (CPC) and titanium mesh. In group 3, 6 sheep underwent laparoscopical L4-5 interbody fusion with titanium mesh as well as polyporus composite phosphate calcium and rhBMP-2 compounds. At Weeks 6 and 12 post-operation, the sheep were sacrificed for imaging, biomechanic and morphological examinations. RESULTS: Although there was no statistical difference between open and laparoscopical interbody fusion group when comparing the remaining disc and endplate decorticated, bone fusion occurred in 3 groups after 3 months. A much larger amount of bony callus was observed earlier in laparoscopical L4-5 interbody fusion group with titanium mesh as well as polyporus composite phosphate calcium and rhBMP-2 compounds than two other groups. CONCLUSION: Polyporus composite phosphate calcium and rhBMP-2 compounds are suitable prosthetic materials for clinical trials. When these materials are utilized with a laparoscopical technique, satisfactory interbody fusion may be achieved.


Asunto(s)
Proteína Morfogenética Ósea 2/uso terapéutico , Fosfatos de Calcio/uso terapéutico , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Andamios del Tejido , Animales , Sustitutos de Huesos/uso terapéutico , Laparoscopía , Masculino , Proteínas Recombinantes/uso terapéutico , Ovinos , Titanio/uso terapéutico
2.
Rev Sci Instrum ; 80(2): 025104, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19256675

RESUMEN

The spectral analysis is combined with digital filter to process the vortex sensor signal for reducing the effect of disturbance at low frequency from pipe vibrations and increasing the turndown ratio. Using digital signal processing chip, two kinds of digital signal processing systems are developed to implement these algorithms. One is an integrative system, and the other is a separated system. A limiting amplifier is designed in the input analog condition circuit to adapt large amplitude variation of sensor signal. Some technique measures are taken to improve the accuracy of the output pulse, speed up the response time of the meter, and reduce the fluctuation of the output signal. The experimental results demonstrate the validity of the digital signal processing systems.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda