Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Electrophoresis ; 45(5-6): 380-391, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38072651

RESUMEN

In contemporary biomedical research, the zebrafish (Danio rerio) is increasingly considered a model system, as zebrafish embryos and larvae can (potentially) fill the gap between cultured cells and mammalian animal models, because they can be obtained in large numbers, are small and can easily be manipulated genetically. Given that capillary electrophoresis-mass spectrometry (CE-MS) is a useful analytical separation technique for the analysis of polar ionogenic metabolites in biomass-limited samples, the aim of this study was to develop and assess a CE-MS-based analytical workflow for the profiling of (endogenous) metabolites in extracts from individual zebrafish larvae and pools of small numbers of larvae. The developed CE-MS workflow was used to profile metabolites in extracts from pools of 1, 2, 4, 8, 12, 16, 20, and 40 zebrafish larvae. For six selected endogenous metabolites, a linear response (R2  > 0.98) for peak areas was obtained in extracts from these pools. The repeatability was satisfactory, with inter-day relative standard deviation values for peak area of 9.4%-17.7% for biological replicates (n = 3 over 3 days). Furthermore, the method allowed the analysis of over 70 endogenous metabolites in a pool of 12 zebrafish larvae, and 29 endogenous metabolites in an extract from only 1 zebrafish larva. Finally, we applied the optimized CE-MS workflow to identify potential novel targets of the mineralocorticoid receptor in mediating the effects of cortisol.


Asunto(s)
Hidrocortisona , Pez Cebra , Animales , Hidrocortisona/farmacología , Larva , Flujo de Trabajo , Espectrometría de Masas/métodos , Metabolómica/métodos , Electroforesis Capilar/métodos , Mamíferos
2.
Electrophoresis ; 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38456383

RESUMEN

When hospitalized, infants, particularly preterm, are often subjected to multiple painful needle procedures to collect sufficient blood for metabolic screening or diagnostic purposes using standard clinical tests. For example, at least 100 µL of whole blood is required to perform one creatinine plasma measurement with enzymatic colorimetric assays. As capillary electrophoresis-mass spectrometry (CE-MS) utilizing a sheathless porous tip interface only requires limited amounts of sample for in-depth metabolic profiling studies, the aim of this work was to assess the utility of this method for the determination of creatinine in low amounts of plasma using residual blood samples from adults and infants. By using a starting amount of 5 µL of plasma and an injection volume of only 6.7 nL, a detection limit (S/N = 3) of 30 nM could be obtained for creatinine, and intra- and interday precisions (for peak area ratios) were below 3.2%. To shorten the electrophoretic separation time, a multi-segment injection (MSI) strategy was employed to analyze up to seven samples in one electrophoretic run. The findings obtained by CE-MS for creatinine in pretreated plasma were compared with the values acquired by an enzymatic colorimetric assay typically used in clinical laboratories for this purpose. The comparison revealed that CE-MS could be used in a reliable way for the determination of creatinine in residual plasma samples from infants and adults. Nevertheless, to underscore the clinical efficacy of this method, a subsequent investigation employing an expanded pool of plasma samples is imperative. This will not only enhance the method's diagnostic utility but also contribute to minimizing both the amount and frequency of blood collection required for diagnostic purposes.

3.
Electrophoresis ; 43(18-19): 1814-1821, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35560354

RESUMEN

The composition of wine is determined by a complex interaction between environmental factors, genetic factors (i.e., grape varieties), and winemaking practices (including technology and storage). Metabolomics using NMR spectroscopy, GC-MS, and/or LC-MS has shown to be a useful approach for assessing the origin, authenticity, and quality of various wines. Nonetheless, the use of additional analytical techniques with complementary separation mechanisms may aid in the deeper understanding of wine's metabolic processes. In this study, we demonstrate that CE-MS is a very suitable approach for the efficient profiling of polar ionogenic metabolites in wines. Without using any sample preparation or derivatization, wine was analyzed using a 10-min CE-MS workflow with interday RSD values for 31 polar and charged metabolites below 3.8% and 23% for migration times and peak areas, respectively. The utility of this workflow for the global profiling of polar ionogenic metabolites in wine was evaluated by analyzing different cool-climate Polish wine samples.


Asunto(s)
Vino , Electroforesis Capilar/métodos , Espectrometría de Masas/métodos , Metabolómica/métodos , Polonia , Vino/análisis
4.
Anal Chem ; 92(20): 14103-14112, 2020 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-32961048

RESUMEN

Capillary zone electrophoresis-mass spectrometry (CE-MS) is a mature analytical tool for the efficient profiling of (highly) polar and ionizable compounds. However, the use of CE-MS in comparison to other separation techniques remains underrepresented in metabolomics, as this analytical approach is still perceived as technically challenging and less reproducible, notably for migration time. The latter is key for a reliable comparison of metabolic profiles and for unknown biomarker identification that is complementary to high resolution MS/MS. In this work, we present the results of a Metabo-ring trial involving 16 CE-MS platforms among 13 different laboratories spanning two continents. The goal was to assess the reproducibility and identification capability of CE-MS by employing effective electrophoretic mobility (µeff) as the key parameter in comparison to the relative migration time (RMT) approach. For this purpose, a representative cationic metabolite mixture in water, pretreated human plasma, and urine samples spiked with the same metabolite mixture were used and distributed for analysis by all laboratories. The µeff was determined for all metabolites spiked into each sample. The background electrolyte (BGE) was prepared and employed by each participating lab following the same protocol. All other parameters (capillary, interface, injection volume, voltage ramp, temperature, capillary conditioning, and rinsing procedure, etc.) were left to the discretion of the contributing laboratories. The results revealed that the reproducibility of the µeff for 20 out of the 21 model compounds was below 3.1% vs 10.9% for RMT, regardless of the huge heterogeneity in experimental conditions and platforms across the 13 laboratories. Overall, this Metabo-ring trial demonstrated that CE-MS is a viable and reproducible approach for metabolomics.


Asunto(s)
Electroforesis Capilar/métodos , Compuestos Orgánicos/sangre , Compuestos Orgánicos/orina , Espectrometría de Masas en Tándem/métodos , Cationes/química , Bases de Datos de Compuestos Químicos , Electrólitos/química , Humanos , Metaboloma , Metabolómica , Reproducibilidad de los Resultados
5.
Electrophoresis ; 40(18-19): 2349-2359, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31106868

RESUMEN

The efficient profiling of highly polar and charged metabolites in biological samples remains a huge analytical challenge in metabolomics. Over the last decade, new analytical techniques have been developed for the selective and sensitive analysis of polar ionogenic compounds in various matrices. Still, the analysis of such compounds, notably for acidic ionogenic metabolites, remains a challenging endeavor, even more when the available sample size becomes an issue for the total analytical workflow. In this paper, we give an overview of the possibilities of capillary electrophoresis-mass spectrometry (CE-MS) for anionic metabolic profiling by focusing on main methodological developments. Attention is paid to the development of improved separation conditions and new interfacing designs in CE-MS for anionic metabolic profiling. A complete overview of all CE-MS-based methods developed for this purpose is provided in table format (Table 1) which includes information on sample type, separation conditions, mass analyzer and limits of detection (LODs). Selected applications are discussed to show the utility of CE-MS for anionic metabolic profiling, especially for small-volume biological samples. On the basis of the examination of the reported literature in this specific field, we conclude that there is still room for the design of a highly sensitive and reliable CE-MS method for anionic metabolic profiling. A rigorous validation and the availability of standard operating procedures would be highly favorable in order to make CE-MS an alternative, viable analytical technique for metabolomics.


Asunto(s)
Aniones/análisis , Electroforesis Capilar , Espectrometría de Masas , Metaboloma/fisiología , Metabolómica , Animales , Humanos , Límite de Detección , Ratones , Ratas , Reproducibilidad de los Resultados
6.
Methods Mol Biol ; 2571: 95-103, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36152153

RESUMEN

Capillary electrophoresis-mass spectrometry (CE-MS) is gaining interest for metabolomics studies because of its high separation efficiency, selectivity, and versatility. The ability to inject nanoliters from only a few microliters of sample in the injection vial makes this approach very suited for volume-limited applications. However, the low injection volumes could compromise the detection sensitivity of CE-MS, thereby potentially limiting its scope in metabolomics. To overcome this issue, online sample preconcentration methods have been developed to increase sample-loading volumes without hampering the intrinsic high separation efficiency of CE. In this protocol, online preconcentration with sample stacking based on pH junction was assessed for the direct profiling of endogenous metabolites in rat brain microdialysates. Sample stacking was realized by a pre-injection of ammonium hydroxide, followed by a large sample injection (i.e., about 17% of the total capillary volume). It is shown that this relatively simple and fast preconcentration procedure is fully compatible with the high-salt concentration in microdialysates and significantly improves the detection sensitivity of the CE-MS method.


Asunto(s)
Electroforesis Capilar , Metabolómica , Hidróxido de Amonio , Animales , Electroforesis Capilar/métodos , Espectrometría de Masas/métodos , Metabolómica/métodos , Ratas
7.
Methods Mol Biol ; 2571: 105-114, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36152154

RESUMEN

The simultaneous analysis of cationic and anionic metabolites using capillary electrophoresis-mass spectrometry (CE-MS) has been considered challenging, as often two different analytical methods are required. Although CE-MS methods for cationic metabolite profiling have already shown good performance metrics, the profiling of anionic metabolites often results in relatively low sensitivity and poor repeatability caused by problems related to unstable electrospray and corona discharge when using reversed CE polarity and detection by MS in negative ionization mode. In this protocol, we describe a chemical derivatization procedure that provides a permanent positive charge to acidic metabolites, thereby allowing us to profile anionic metabolites by CE-MS using exactly the same separation conditions as employed for the analysis of basic metabolites. The utility of the overall approach is demonstrated for the analysis of energy metabolism-related metabolites in low numbers of HepG2 cells.


Asunto(s)
Electroforesis Capilar , Espectrometría de Masa por Ionización de Electrospray , Animales , Aniones , Cationes , Electroforesis Capilar/métodos , Mamíferos , Espectrometría de Masa por Ionización de Electrospray/métodos
8.
Metabolites ; 12(8)2022 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-36005613

RESUMEN

The metabolic profiling of a wide range of chemical classes relevant to understanding sarcopenia under conditions in which sample availability is limited, e.g., from mouse models, small muscles, or muscle biopsies, is desired. Several existing metabolomics platforms that include diverse classes of signaling lipids, energy metabolites, and amino acids and amines would be informative for suspected biochemical pathways involved in sarcopenia. The sample limitation requires an optimized sample preparation method with minimal losses during isolation and handling and maximal accuracy and reproducibility. Here, two developed sample preparation methods, BuOH-MTBE-Water (BMW) and BuOH-MTBE-More-Water (BMMW), were evaluated and compared with previously reported methods, Bligh-Dyer (BD) and BuOH-MTBE-Citrate (BMC), for their suitability for these classes. The most optimal extraction was found to be the BMMW method, with the highest extraction recovery of 63% for the signaling lipids and 81% for polar metabolites, and an acceptable matrix effect (close to 1.0) for all metabolites of interest. The BMMW method was applied on muscle tissues as small as 5 mg (dry weight) from the well-characterized, prematurely aging, DNA repair-deficient Ercc1∆/- mouse mutant exhibiting multiple-morbidities, including sarcopenia. We successfully detected 109 lipids and 62 polar targeted metabolites. We further investigated whether fast muscle tissue isolation is necessary for mouse sarcopenia studies. A muscle isolation procedure involving 15 min at room temperature revealed a subset of metabolites to be unstable; hence, fast sample isolation is critical, especially for more oxidative muscles. Therefore, BMMW and fast muscle tissue isolation are recommended for future sarcopenia studies. This research provides a sensitive sample preparation method for the simultaneous extraction of non-polar and polar metabolites from limited amounts of muscle tissue, supplies a stable mouse muscle tissue collection method, and methodologically supports future metabolomic mechanistic studies of sarcopenia.

9.
Anal Sci Adv ; 3(1-2): 3-13, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38716053

RESUMEN

The simultaneous analysis of a broad range of polar ionogenic metabolites using capillary electrophoresis-mass spectrometry (CE-MS) can be challenging, as two different analytical methods are often required, that is, one for cations and one for anions. Even though CE-MS has shown to be an effective method for cationic metabolite profiling, the analysis of small anionic metabolites often results in relatively low sensitivity and poor repeatability. In this work, a novel derivatization strategy based on trimethylmethaneaminophenacetyl bromide was developed to enable CE-MS analysis of carboxylic acid metabolites using normal CE polarity (i.e., cathode in the outlet) and detection by mass spectrometry in positive ionization mode. Optimization of derivatization conditions was performed using a response surface methodology after which the optimized method (incubation time 50 min, temperature 90°C, and pH 10) was used for the analysis of carboxylic acid metabolites in extracts from HepG2 cells. For selected metabolites, detection limits were down to 8.2 nM, and intraday relative standard deviation values for replicates (n = 3) for peak areas were below 21.5%. Metabolites related to glycolysis, tricarboxylic acid cycle, and anaerobic respiration pathways were quantified in 250,000 cell lysates, and could still be detected in extracts from only 25,000 HepG2 cell lysates (∼70 cell lysates injected).

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda