Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
2.
PLoS One ; 19(3): e0297739, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38457477

RESUMEN

In recent years, the importance of isolating single cells from blood circulation for several applications, such as non-invasive tumour diagnosis, the monitoring of minimal residual disease, and the analysis of circulating fetal cells for prenatal diagnosis, urged the need to set up innovative methods. For such applications, different methods were developed. All show some weaknesses, especially a limited sensitivity, and specificity. Here we present a new method for isolating a single or a limited number of cells adhered to SBS slides (Tethis S.p.a.) (a glass slide coated with Nanostructured Titanium Dioxide) by Laser Capture Microdissection (LCM) and subsequent Whole Genome Amplification. SBS slides have been shown to have an optimal performance in immobilizing circulating tumour cells (CTCs) from early breast cancer patients. In this work, we spiked cancer cells in blood samples to mimic CTCs. By defining laser parameters to cut intact samples, we were able to isolate genetically intact single cells. We demonstrate that SBS slides are optimally suited for isolating cells using LCM and that this method provides high-quality DNA, ideal for gene-specific assays such as PCR and Sanger sequencing for mutation analysis.


Asunto(s)
Células Neoplásicas Circulantes , Embarazo , Femenino , Humanos , Captura por Microdisección con Láser/métodos , Células Neoplásicas Circulantes/patología , ADN
3.
Obstet Gynecol ; 137(6): 1102-1108, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33957658

RESUMEN

OBJECTIVE: To evaluate the accuracy and diagnostic value of genome-wide noninvasive prenatal testing (NIPT) for the detection of fetal aneuploidies in multiple gestations, with a focus on dichorionic-diamniotic twin pregnancies. METHODS: We performed a retrospective cohort study including data from pregnant women with a twin or higher-order gestation who underwent genome-wide NIPT at one of the eight Belgian genetic centers between November 1, 2013, and March 1, 2020. Chorionicity and amnionicity were determined by ultrasonography. Follow-up invasive testing was carried out in the event of positive NIPT results. Sensitivity and specificity were calculated for the detection of trisomy 21, 18, and 13 in the dichorionic-diamniotic twin cohort. RESULTS: Unique NIPT analyses were performed for 4,150 pregnant women with a multiple gestation and an additional 767 with vanishing gestations. The failure rate in multiple gestations excluding vanishing gestations ranged from 0% to 11.7% among the different genetic centers. Overall, the failure rate was 4.8%, which could be reduced to 1.2% after single resampling. There were no common fetal trisomies detected among the 86 monochorionic-monoamniotic and 25 triplet cases. Two monochorionic-diamniotic twins had an NIPT result indicative of a trisomy 21, which was confirmed in both fetuses. Among 2,716 dichorionic-diamniotic twin gestations, a sensitivity of 100% (95% CI 74.12-100%) and a specificity of 100% (95% CI 99.86-100%) was reached for trisomy 21 (n=12). For trisomy 18 (n=3), the respective values were 75% (95% CI 30.06-95.44%) sensitivity and 100% (95% CI 99.86-100%) specificity, and for trisomy 13 (n=2), 100% (95% CI 20.65-100%) sensitivity and 99.96% (95% CI 99.79-99.99%) specificity. In the vanishing gestation group, 28 NIPT results were positive for trisomy 21, 18, or 13, with only five confirmed trisomies. CONCLUSION: Genome-wide NIPT performed accurately for detection of aneuploidy in dichorionic-diamniotic twin gestations.


Asunto(s)
Síndrome de Down/diagnóstico , Reabsorción del Feto , Pruebas Prenatales no Invasivas , Embarazo Múltiple , Síndrome de la Trisomía 13/diagnóstico , Síndrome de la Trisomía 18/diagnóstico , Amniocentesis , Amnios/diagnóstico por imagen , Ácidos Nucleicos Libres de Células/análisis , Corion/diagnóstico por imagen , Errores Diagnósticos , Reacciones Falso Negativas , Femenino , Reabsorción del Feto/diagnóstico , Reabsorción del Feto/genética , Genoma Humano , Humanos , Embarazo , Embarazo Cuádruple , Embarazo Triple , Embarazo Gemelar , Estudios Retrospectivos , Sensibilidad y Especificidad , Trisomía
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda