Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Rep Pract Oncol Radiother ; 26(4): 598-604, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34434576

RESUMEN

BACKGROUND: A purpose of the study was to investigate the dosimetric impact of contrast media on dose calculation using average 4D contrast-enhanced computed tomography (4D-CECT) and delayed 4D-CT (d4D-CT) images caused by CT simulation contrast agents for stereotactic body radiation therapy (SBRT) of liver cases. MATERIALS AND METHODS: Fifteen patients of liver SBRT treated using the volumetric modulated arc therapy (VMAT) technique were selected retrospectively. 4D-CECT, and d4D-CT were acquired with the Anzai gating system and GE CT. For all patients, gross target volume (GTV) was contoured on the ten phases after rigid registration of both the contrast and delayed scans and merged to generate internal target volume (ITV) on average CT images. Region of interest (ROI) was drawn on contrast images and then copied to the delayed images after rigid registration of two average CT datasets. The treatment plans were generated for contrast enhanced average CT, delayed average CT and contrast enhanced average CT with electron density of the heart overridden. RESULTS: No significant dosimetric difference was observed in plans parameters (mean HU value of the liver, total monitor units, total control points, degree of modulation and average segment area) except mean HU value of the aorta amongst the three arms. All the OARs were evaluated and resulted in statistically insignificant variation (p > 0.05) using one way ANOVA analysis. CONCLUSIONS: Contrast enhanced 4D-CT is advantageous in accurate delineation of tumors and assessing accurate ITV. The treatment plans generated on average 4D-CECT and average d4D-CT have a clinically insignificant effect on dosimetric parameters.

2.
Endocrine ; 74(2): 404-412, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34173158

RESUMEN

INTRODUCTION: In primary hyperparathyroidism (PHPT), the localization of hyperfunctioning parathyroid gland (HPTG) allows tailored surgery. Although Four-Dimensional Contrast-enhanced Computed Tomography (4DCeCT) and 18F-choline Positron Emission Tomography/Computed Tomography (PET/CT) are reported to be promising second-line imaging procedures, no meta-analysis of their comparison exists. DESIGN: we conducted a systematic review and meta-analysis to find original papers reporting the head-to-head comparison of 4DCeCT, 18F-choline PET/CT and integrated 18F-choline-PET/4DCeCT. METHODS: this systematic review was conducted according to PRISMA. PubMed, CENTRAL, Scopus, and Web of Science were searched until January 2021. Studies comparing the ability of 4DCeCT, 18F-choline PET/CT and 18F-choline PET/4DCeCT to identify HPTG in patients with PHPT were selected. A per patient-based analysis of the three procedures was conducted in all patients (detection rate, DR) and in those with histologically confirmed HPTG (sensitivity). RESULTS: Of the 78 records identified, five articles (153 PHPT patients) published between January the 1st, 2018 and January the 31st, 2021 were included. The pooled DR of 18F-choline PET/CT, 4DCeCT and 18F-choline PET/4DCeCT was 0.86, 0.69, and 0.86, respectively, while their pooled sensitivity was 0.89, 0.77 and 0.93, respectively. The analysis of pooled discrepancy showed that the sensitivity of 18F-choline PET/CT and 18F-choline PET/4DCeCT was higher than that of 4DCeCT by 0.11 and 0.13, respectively, the sensitivity of 18F-choline PET/4DCeCT being 0.06 higher than that of 18F-Choline PET/CT. CONCLUSIONS: This meta-analysis suggests that the sensitivity of 18F-choline PET/CT and 18F-choline PET/4DCeCT is higher than that of 4DCeCT, while only a slight difference was observed between 18F-choline PET/CT and 18F-choline PET/4DCeCT.


Asunto(s)
Hiperparatiroidismo Primario , Tomografía Computarizada por Tomografía de Emisión de Positrones , Bibliometría , Colina , Humanos , Glándulas Paratiroides/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda