Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 3.612
Filtrar
Más filtros

Publication year range
1.
J Comput Chem ; 45(9): 574-588, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38041830

RESUMEN

We investigated the intrinsic strength of distal and proximal FeN bonds for both ferric and ferrous oxidation states of bishistidyl hemoproteins from bacteria, animals, human, and plants, including two cytoglobins, ten hemoglobins, two myoglobins, six neuroglobins, and six phytoglobins. As a qualified measure of bond strength, we used local vibrational force constants k a (FeN) based on local mode theory developed in our group. All calculations were performed with a hybrid QM/MM ansatz. Starting geometries were taken from available x-ray structures. k a (FeN) values were correlated with FeN bond lengths and covalent bond character. We also investigated the stiffness of the axial NFeN bond angle. Our results highlight that protein effects are sensitively reflected in k a (FeN), allowing one to compare trends in diverse protein groups. Moreover, k a (NFeN) is a perfect tool to monitor changes in the axial heme framework caused by different protein environments as well as different Fe oxidation states.


Asunto(s)
Histidina , Hierro , Animales , Humanos , Hierro/química , Hemo/química , Hemoglobinas , Oxidación-Reducción
2.
J Comput Chem ; 45(14): 1130-1142, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38279637

RESUMEN

The Local Vibrational Mode Analysis, initially applied to diverse molecular systems, was extended to periodic systems in 2019. This work introduces an enhanced version of the LModeA software, specifically designed for the comprehensive analysis of two and three-dimensional periodic structures. Notably, a novel interface with the Crystal package was established, enabling a seamless transition from molecules to periodic systems using a unified methodology. Two distinct sets of uranium-based systems were investigated: (i) the evolution of the Uranyl ion (UO 2 2 + ) traced from its molecular configurations to the solid state, exemplified by Cs 2 UO 2 Cl 4 and (ii) Uranium tetrachloride (UCl 4 ) in both its molecular and crystalline forms. The primary focus was on exploring the impact of crystal packing on key properties, including IR and Raman spectra, structural parameters, and an in-depth assessment of bond strength utilizing local mode perspectives. This work not only demonstrates the adaptability and versatility of LModeA for periodic systems but also highlights its potential for gaining insights into complex materials and aiding in the design of new materials through fine-tuning.

3.
Chemistry ; : e202402008, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39031500

RESUMEN

Solvent molecules interact with a solute through various intermolecular forces. Here we employed a potential energy surface (PES) analysis to interpret the solvent-induced variations in the strengths of dative (Me3NBH3) and ionic (LiCl) bonds, which possess both ionic and covalent (neutral) characteristics. The change of a bond is driven by the gradient (force) of the solvent-solute interaction energy with respect to the focused bond length. Positive force shortens the bond length and increases the bond force constant, leading to a blue-shift of the bond stretching vibrational frequency upon solvation. Conversely, negative force elongates the bond, resulting in a reduced bond force constant and red-shift of the stretching vibrational frequency. The different responses of Me3NBH3 and LiCl to solvation are studied with valence bond (VB) theory, as Me3NBH3 and LiCl are dominated by the neutral covalent VB structure and the ionic VB structure, respectively. The dipole moment of an ionic VB structure increases along the increasing bond distance, while the dipole moment of a neutral covalent VB structure increases with the decreasing bond distance. The roles of the dominating VB structures are further examined by the geometry optimizations and frequency calculations with the block-localized wavefunction (BLW) method.

4.
Eur J Oral Sci ; 132(4): e12994, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38780370

RESUMEN

This study evaluated the effect on adhesive layer thickness, bond strength, and adhesive failure pattern of the application of universal adhesive (Scotchbond Universal) using either manual or rotary brush in dentin previously impregnated with bioceramic sealer (Sealer Plus BC) using a manual brush, at 24 h and 1 year. Eighty-eight bovine crowns were divided into four groups (n = 22) according to the intervention: (i) use of bioceramic sealer and adhesive application using manual brush, (ii) use of bioceramic sealer and adhesive application using rotary brush, (iii) use of resin sealer and adhesive application using manual brush, and (iv) use of resin sealer and adhesive application using rotary brush. Subsequently, specimens were restored with a composite resin (Filtek Z-250). Adhesive layer thickness was evaluated using confocal microscopy. Bond strength was assessed using the microtensile bond strength test, and adhesive failure pattern was evaluated under a stereomicroscope. Data were analyzed using two-way ANOVA/Tukey tests. Specimens where a rotary brush had been used exhibited lower adhesive layer thickness. Specimens treated with resin sealer and using a manual brush showed lower bond strength values and a higher occurrence of adhesive failures at 24 h and 1 year than specimens treated with bioceramic sealer and using rotary brush for adhesive application.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Cementos de Resina , Resistencia a la Tracción , Animales , Recubrimiento Dental Adhesivo/métodos , Bovinos , Cementos de Resina/química , Resinas Compuestas/química , Ensayo de Materiales , Recubrimientos Dentinarios/química , Análisis del Estrés Dental , Dentina , Propiedades de Superficie , Microscopía Confocal , Factores de Tiempo
5.
Eur J Oral Sci ; 132(1): e12965, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38115770

RESUMEN

This study evaluated the effect of different concentrations of alpha-tocopherol in gel form on fracture strength, hybrid layer formation, and microtensile bond strength of endodontically treated teeth bleached with 40% hydrogen peroxide (H2 O2 ). Sixty bovine incisors were randomized into one of six groups (n = 10 incisors per group) defined by the interventions carried out after endodontic treatment. In the control group, no additional intervention was carried out, while all teeth in the five intervention groups were bleached with 40% H2 O2 and subsequently treated with alpha-tocopherol at concentrations of 15% (15AT), 20% (20AT), or 25% (25AT), with 10% sodium ascorbate (10SA), or with nothing (40HP). Fracture strength was evaluated in a mechanical testing machine, hybrid layer formation was assessed using scanning electron microscopy, and bond strength was determined using microtensile bond-strength testing. Data were analyzed using Kruskal-Wallis and Dunn's tests. No statistically significant difference regarding fracture strength was observed among groups. Hybrid layer formation was greater in the 15AT group than in groups 40HP and 10SA. Teeth in groups 15AT, 20AT, and 25AT demonstrated higher bond strength than teeth in groups 40HP and 10SA. Alpha-tocopherol, preferably at 15%, effectively reverses the deleterious effects, of bleaching, on hybrid layer formation and bond strength to dentin.


Asunto(s)
Recubrimiento Dental Adhesivo , Blanqueamiento de Dientes , Diente no Vital , Bovinos , Animales , Antioxidantes/química , Antioxidantes/farmacología , alfa-Tocoferol/farmacología , Resistencia Flexional , Resinas Compuestas/química , Ácido Hipocloroso
6.
Eur J Oral Sci ; 132(3): e12989, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38679835

RESUMEN

This study aimed at examining the bond strength between zirconia and ceramic veneer, following the ISO 9693 guidelines. A total of fifty specimens of zirconia/ceramic-veneer system were produced using two commercial zirconias (VITA YZ-HTWhite and Zolid HT+ White, referred to as Group A and Group B, respectively) and a ceramic-veneering material (Zirkonia 750). The microstructure (via x-ray diffraction analysis, XRD and Secondary Electron mode, SEM) and the mechanical properties (via 3-point bending tests) of the two groups were assessed. Then, experiments were conducted according to the ISO 9693 and conventional protocols applied for producing zirconia/ceramic-veneer restorations. Bond strength values, measured by 3-point bending tests, were 34.42 ± 7.60 MPa for Group A and 31.92 ± 6.95 MPa for Group B. SEM observations of the cohesively fractured surfaces (on the porcelain side) and the examination for normality using the Shapiro-Wilk test suggested the use of Weibull statistical analysis. Median strength (σ50%) for Group A and Group B was 34.76 and 32.22 MPa, while the characteristic strength (σ63.2%) was 35.78 and 33.14 MPa, respectively. The Weibull modulus disparity between groups (12.69 and 13.07) was not significant. Bond strength exceeded the ISO 9693 minimum of 20 MPa, suggesting satisfactory strength for clinical use.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Análisis del Estrés Dental , Coronas con Frente Estético , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Difracción de Rayos X , Circonio , Circonio/química , Porcelana Dental/química , Propiedades de Superficie , Cerámica/química , Materiales Dentales/química , Humanos
7.
Lasers Med Sci ; 39(1): 93, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520540

RESUMEN

Blue diode lasers are alternative curing devices for dental composites. The aim of this study was to investigate the influence of blue diode laser polymerization on shear bond strength of bulk fill composites to human dentin and temperature rise during two types of polymerization. Composite cylinders of SDR Plus(SDR) and Ever X Flow(EX) were bonded to dentin slabs using Adhese Universal and curing devices blue diode laser (449 nm, 1.6 W) and Power Cure LED. For each material and curing device there were two polymerization approaches: 1)conventional: separate curing of adhesive; 2)co-curing: simultaneous adhesive and composite curing. Polymerization modes for each material in conventional and co-curing(c) approach were: blue laser 2000 mW/cm2 for 5 s (L5 and L5c); blue laser 1000 mW/cm2 for 10 s (L10 and L10c); Power Cure 2000 mW/cm2 for 5 s (LED5 and LED5c); Power Cure 1000 mW/cm2 for 10 s (LED10 and LED10c). Temeperature was measured using thermal vision camera. For SDR, the highest bond strength was 24.3 MPa in L10c, and the lowest 9.2 MPa in LED5c. EX exhibited the highest bond strength(21.3 MPa) in LED5, and the lowest in L5(7.7 MPa). The highest temperature rise for SDR was in L10 and L5 (7.3 and 7.2 °C), and the lowest in LED5(0.8 °C). For EX, the highest temperature rise was in L5 (13.0 °C), and the lowest in LED5 (0.7 °C). Temperature rise was higher during blue laser polymerization, especially at high intensity and with conventional curing. Preferable blue laser curing mode is co-curing at 1000mW/cm2 for 10 s.


Asunto(s)
Resinas Compuestas , Dentina , Humanos , Temperatura , Polimerizacion , Ensayo de Materiales , Resinas Compuestas/química , Rayos Láser
8.
Clin Oral Investig ; 28(7): 386, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38890207

RESUMEN

OBJECTIVE: This study aimed to evaluate the effect of ultrasonic activation of etch-and-rinse and self-etch adhesive systems on the bond strength of resin cement to irradiated root dentin. MATERIALS AND METHODS: Eighty human maxillary anterior teeth were distributed into 8 groups (n = 10), according to the type of adhesive system used (etch-and-rinse and self-etch), the ultrasonic activation of the adhesive systems, and the dentin condition (irradiated or non-irradiated - 70 Gy). Endodontic treatment was performed followed by fiberglass post-space preparation. After fiberglass posts' luting, the roots were transversely sectioned on dentin discs and submitted to the push-out bond strength test (0.5 mm/min). The fractured specimens were analyzed under a stereomicroscope and Scanning Electron Microscope (SEM) for failure mode classification. One of the dentin discs was analyzed under SEM to evaluate the characteristics of the adhesive interface. RESULTS: Irradiated specimens had lower bond strength than non-irradiated specimens (P < 0.0001). Ultrasonic activation of both adhesive systems increased the bond strength of the resin cement to irradiated dentin (P < 0.0001). Radiotherapy significantly affected the failure mode in the middle (P = 0.024) and apical thirds (P = 0.032) (adhesive failure). CONCLUSION: Non-irradiated specimens had a more homogeneous adhesive interface. When ultrasonically activated, both adhesive systems showed a greater number of resinous tags, regardless of the dentin condition. CLINICAL RELEVANCE: Ultrasonic activation of adhesive systems is a feasible strategy to enhance fiberglass posts retention in oncological patients.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Técnica de Perno Muñón , Cementos de Resina , Humanos , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Dentina/efectos de la radiación , Técnicas In Vitro , Recubrimientos Dentinarios/química , Análisis del Estrés Dental , Propiedades de Superficie , Raíz del Diente/efectos de la radiación , Ultrasonido , Grabado Ácido Dental , Incisivo , Vidrio/química
9.
Clin Oral Investig ; 28(6): 305, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38722356

RESUMEN

OBJECTIVE: To evaluate the ability of the water glass treatment to penetrate zirconia and improve the bond strength of resin cement. MATERIAL AND METHODS: Water glass was applied to zirconia specimens, which were then sintered. The specimens were divided into water-glass-treated and untreated zirconia (control) groups. The surface properties of the water-glass-treated specimens were evaluated using surface roughness and electron probe micro-analyser (EPMA) analysis. A resin cement was used to evaluate the tensile bond strength, with2 and without a silane-containing primer. After 24 h in water storage at 37 °C and thermal cycling, the bond strengths were statistically evaluated with t-test, and the fracture surfaces were observed using SEM. RESULTS: The water glass treatment slightly increased the surface roughness of the zirconia specimens, and the EPMA analysis detected the water glass penetration to be 50 µm below the zirconia surface. The application of primer improved the tensile bond strength in all groups. After 24 h, the water-glass-treated zirconia exhibited a tensile strength of 24.8 ± 5.5 MPa, which was significantly higher than that of the control zirconia (17.6 ± 3.5 MPa) (p < 0.05). After thermal cycling, the water-glass-treated zirconia showed significantly higher tensile strength than the control zirconia. The fracture surface morphology was mainly an adhesive pattern, whereas resin cement residue was occasionally detected on the water-glass-treated zirconia surfaces. CONCLUSION: The water glass treatment resulted in the formation of a stable silica phase on the zirconia surface. This process enabled silane coupling to the zirconia and improved the adhesion of the resin cement.


Asunto(s)
Recubrimiento Dental Adhesivo , Vidrio , Ensayo de Materiales , Cementos de Resina , Silanos , Propiedades de Superficie , Resistencia a la Tracción , Agua , Circonio , Circonio/química , Cementos de Resina/química , Silanos/química , Agua/química , Recubrimiento Dental Adhesivo/métodos , Vidrio/química , Microscopía Electrónica de Rastreo , Análisis del Estrés Dental
10.
Clin Oral Investig ; 28(8): 444, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046575

RESUMEN

OBJECTIVES: To evaluate the effect of proanthocyanidin-functionalized hydroxyapatite nanoparticles (nHAp_PA) used as pretreatment at different concentrations on the microtensile bond strength (µTBS) and endogenous enzymatic activity (MMPs) on pH-cycled dentin after 24 h and 6 months of artificial aging. MATERIALS AND METHODS: Fifty human sound dentin blocks were randomly assigned to 5 groups (n = 10): (i) negative control (no treatment); (ii) positive control (pH-cycling); (iii) pH-cycling + 2% nHAp_PA for 60s; (iv) pH-cycling + 6.5% nHAp_PA for 60s; (v) pH-cycling + 15% nHAp_PA for 60s. A self-etch adhesive was used for bonding procedures before resin composite build-ups. Specimens were tested with the µTBS test after 24 h and 6 months of laboratory storage. The proteolytic activity in each group was evaluated with gelatin zymography and in situ zymography. Data were statistically analyzed (p < 0.05). RESULTS: At 24 h, the µTBS of the experimental groups were significantly higher than the controls (p ≤ 0.001), and no differences were observed between different concentrations (p > 0.05). Artificial aging significantly decreased bond strength in all groups (p ≤ 0.008); however, nHAp_PA 2% still yielded higher bonding values than controls (p ≤ 0.007). The groups pretreated with nHAp_PA exhibited lower MMP-9 and MMP-2 activities compared to the positive control group and almost the same enzymatic activity as the negative control group. In situ zymography showed that after 6 months of aging, nHAp_PA 2% and nHAp_PA 6,5% decreased enzymatic activity as well as the negative control. CONCLUSIONS: Dentin pretreatment with nHAp_PA increased the bonding performance of a self-etch adhesive and decreased MMP-2 and MMP-9 activities after 6 months.


Asunto(s)
Recubrimiento Dental Adhesivo , Durapatita , Ensayo de Materiales , Nanopartículas , Proantocianidinas , Resistencia a la Tracción , Proantocianidinas/química , Proantocianidinas/farmacología , Durapatita/química , Nanopartículas/química , Humanos , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Dentina , Propiedades de Superficie , Técnicas In Vitro , Análisis del Estrés Dental , Concentración de Iones de Hidrógeno , Resinas Compuestas/química , Distribución Aleatoria
11.
Clin Oral Investig ; 28(7): 371, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38869697

RESUMEN

OBJECTIVES: The purpose of this study is to evaluate the bond strength of different computer-aided design / computer-aided manufacturing (CAD/CAM) hybrid ceramic materials following different pretreatments. METHODS: A total of 306 CAD/CAM hybrid material specimens were manufactured, n = 102 for each material (VarseoSmile Crownplus [VSCP] by 3D-printing; Vita Enamic [VE] and Grandio Blocs [GB] by milling). Each material was randomly divided into six groups regarding different pretreatment strategies: control, silane, sandblasting (50 µm aluminum oxide particles), sandblasting + silane, etching (9% hydrofluorics acid), etching + silane. Subsequently, surface roughness (Ra) values, surface free energy (SFE) were measured. Each specimen was bonded with a dual-cured adhesive composite. Half of the specimens were subjected to thermocycling (5000 cycles, 5-55 °C). The shear bond strength (SBS) test was performed. Data were analyzed by using a two-way analysis of variance, independent t-test, and Mann-Whitney-U-test (α = 0.05). RESULTS: Material type (p = 0.001), pretreatment strategy (p < 0.001), and the interaction (p < 0.001) all had significant effects on Ra value. However, only etching on VSCP and VE surface increased SFE value significantly. Regarding SBS value, no significant difference was found among the three materials (p = 0.937), while the pretreatment strategy significantly influenced SBS (p < 0.05). Etching on VSCP specimens showed the lowest mean value among all groups, while sandblasting and silane result in higher SBS for all test materials. CONCLUSIONS: The bond strength of CAD/CAM hybrid ceramic materials for milling and 3D-printing was comparable. Sandblasting and silane coupling were suitable for both millable and printable materials, while hydrofluoric etching should not be recommended for CAD/CAM hybrid ceramic materials. CLINICAL RELEVANCE: Since comparable evidence between 3D-printable and millable CAD/CAM dental hybrid materials is scarce, the present study gives clear guidance for pretreatment planning on different materials.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Ensayo de Materiales , Resistencia al Corte , Propiedades de Superficie , Recubrimiento Dental Adhesivo/métodos , Cerámica/química , Silanos/química , Materiales Dentales/química , Grabado Dental/métodos , Porcelana Dental/química , Técnicas In Vitro , Humanos
12.
Clin Oral Investig ; 28(2): 149, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355823

RESUMEN

OBJECTIVE: The study aims to evaluate the shear bond and flexural strength fatigue behavior of yttrium-stabilized zirconia (4YSZ) repaired using different resin composites. MATERIALS AND METHODS: Cylindric specimens of 4YSZ were obtained for the bond strength (Ø = 6 mm, 1.5 mm of thickness) and biaxial flexural strength (Ø = 15 mm, 1 mm of thickness) fatigue tests and divided into 3 groups according to the repair resin composite: EVO (nanohybrid), BULK (bulk-fill), and FLOW (flowable). The zirconia surface was air-abraded with alumina particles, a 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer was applied, and the resin composite was build-up over the zirconia. Fatigue shear bond strength and flexural fatigue strength tests were performed (n = 15). One-way ANOVA and Tukey post hoc tests were carried out for both outcomes, besides scanning electron microscopy and finite element analysis. RESULTS: The repair material affected the fatigue shear bond strength of zirconia ceramic. The BULK group (18.9 MPa) depicted higher bond strength values than FLOW (14.8 MPa) (p = 0.04), while EVO (18.0 MPa) showed similar results to both groups. No effect was observed for the mechanical behavior (p = 0.53). The stress distribution was similar for all groups. CONCLUSION: The repair of yttrium-stabilized zirconia (4YSZ) ceramics with bulk-fill resin composites was the best option for high fatigue bond strength. However, the fatigue mechanical performance was similar regardless of the applied repair material. CLINICAL RELEVANCE: The repair of yttrium-stabilized zirconia (4YSZ) monolithic restorations may be performed with nanohybrid and bulk-fill resin composites in order to promote longevity in the treatment.


Asunto(s)
Recubrimiento Dental Adhesivo , Metacrilatos , Recubrimiento Dental Adhesivo/métodos , Propiedades de Superficie , Ensayo de Materiales , Resinas Compuestas/química , Circonio/química , Cerámica/química , Resistencia al Corte , Itrio/química , Cementos de Resina/química , Análisis del Estrés Dental
13.
Odontology ; 112(1): 74-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37036616

RESUMEN

Because the use of hydrofluoric acid (HF) poses health risks if handled improperly, many clinicians prefer to have the ceramic restorations pre-etched in dental laboratories. However, during the try-in procedure, the pre-etched glass-ceramic restorations may be contaminated with saliva resulting in reduced bond strength. This in-vitro study aimed to investigate the effect of different surface treatments on the bond strength of lithium disilicate (LD) glass-ceramic restorations (IPS e.max Press, Ivoclar Vivadent) to two resin cements. One-hundred eighty blocks (4X4X3mm) of LD glass-ceramic were divided into twelve groups (n = 15), of which six received Variolink Esthetic DC (VE) cement and six received RelyX Ultimate (RU) cement, following the surface treatments: G1) Control: Hydrofluoric Acid + Silane (HF + Sil); G2) Hydrofluoric Acid + Saliva + Silane (HF + S + Sil); G3) Hydrofluoric Acid + Saliva + Ivoclean + Silane (HF + S + IC + Sil); G4) Hydrofluoric Acid + Saliva + Phosphoric Acid + Silane (HF + S + P + Sil); G5) Hydrofluoric Acid + Saliva + Monobond Etch & Prime (HF + S + EP); G6) Monobond Etch & Prime (EP). Following treatment, a resin-cement cylinder (2.3 mm diameter) was built on the glass-ceramic surface, photocured (20 s), stored in distilled water (37 °C, 24 h) and submitted to the shear bond strength test. Bond strength data (MPa) were subjected to two-way ANOVA and Tukey (α = 0.01). Cement type and surface treatment had a significant effect on the bond strength (p < 0.001) (Table 4). Single-step Monobond Etch & Prime (EP) significantly improved the bond strength of resin-cements to glass-ceramic with and without saliva contamination.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Ácido Fluorhídrico , Silanos , Propiedades de Superficie , Porcelana Dental , Cerámica , Cementos Dentales , Protocolos Clínicos , Ensayo de Materiales
14.
Odontology ; 112(3): 782-797, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38157108

RESUMEN

There is limited information on the repairability of prostheses produced with digital technology. This study aims to evaluate various surface treatments on flexural bond strength of repaired dentured base resins produced by digital and conventional methods. A total of 360 samples were prepared from one heat-polymerized, one CAD/CAM milled and one 3D printed denture base materials. All of the test samples were subjected to thermocycling (5-55 °C, 5000 cycles) before and after repair with auto-polymerizing acrylic resin. The test samples were divided into five subgroups according to the surface treatment: grinding with silicon carbide (SC), sandblasting with Al2O3 (SB), Er:YAG laser (L), plasma (P) and negative control (NC) group (no treatment). In addition, the positive control (PC) group consisted of intact samples for the flexural strength test. Surface roughness measurements were performed with a profilometer. After repairing the test samples, a universal test device determined the flexural strength values. Both the surface topography and the fractured surfaces of samples were examined by SEM analysis. The elemental composition of the tested samples was analyzed by EDS. Kruskal-Wallis and Mann-Whitney U tests were performed for statistical analysis of data. SB and L surface treatments statistically significantly increased the surface roughness values of all three materials compared to NC subgroups (p < 0.001). The flexural strength values of the PC groups in all three test materials were significantly higher than those of the other groups (p < 0.001). The repair flexural strength values were statistically different between the SC-SB, L-SB, and NC-SB subgroups for the CAD/CAM groups, and the L-SC and L-NC subgroups for the 3D groups (p < 0.001). The surface treatments applied to the CAD/CAM and heat-polymerized groups did not result in a statistically significant difference in the repair flexural strength values compared to the NC groups (p > 0.05). Laser surface treatment has been the most powerful repair method for 3D printing technique. Surface treatments led to similar repair flexural strengths to untreated groups for CAD/CAM milled and heat-polymerized test samples.


Asunto(s)
Compuestos Inorgánicos de Carbono , Diseño Asistido por Computadora , Bases para Dentadura , Resistencia Flexional , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Impresión Tridimensional , Propiedades de Superficie , Compuestos Inorgánicos de Carbono/química , Materiales Dentales/química , Resinas Acrílicas/química , Láseres de Estado Sólido , Recubrimiento Dental Adhesivo/métodos , Análisis del Estrés Dental , Compuestos de Silicona/química , Reparación de la Dentadura , Óxido de Aluminio/química , Polimerizacion
15.
Odontology ; 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38951300

RESUMEN

This study aimed to evaluate the influence of radiotherapy and different endodontic treatment protocols on the bond strength to pulp chamber dentin. Eighty mandibular molars were randomly divided into two groups (n = 40): non-irradiated and irradiated (60 Gy). The pulp chambers were sectioned, and each group was subdivided (n = 8), according to the endodontic treatment protocol: no treatment (Control); Single-visit; Two-visits; Immediate dentin sealing (IDS) + single-visit; and IDS + two-visits. Each endodontic treatment visit was simulated through irrigation with 2.5% NaOCl, 17% EDTA and distilled water. IDS was performed by actively applying two coats of a universal adhesive to the lateral walls of the pulp chamber. After, the pulp chambers were restored with resin composite and four sticks were obtained for microtensile test. In addition, the dentin of the pulp chamber roof was assessed for surface roughness, chemical composition, and topography after each treatment protocol. Two-way ANOVA, Tukey's post hoc, Mann-Whitney, Kruskal-Wallis and Dunn's post hoc were performed (α = 5%). The treatment protocol affected bond strength (p < 0.05), while the irradiation did not (p > 0.05). The control group presented the highest values (p < 0.05). The single-visit group demonstrated better performance compared to the other groups (p < 0.05), which did not differ from each other (p > 0.05) The use of IDS changed the surface roughness (p < 0.05), chemical composition (p < 0.05) and topography of the dentin. In conclusion, the treatment protocol influenced dentin adhesion, while irradiation did not.

16.
Odontology ; 112(2): 435-443, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37845592

RESUMEN

This study aimed to evaluate the effect of dentin hypersensitivity treatments on immediate and long-term shear bond strength (SBS) of composite restorations. Ninety non-carious extracted human molars were cut to expose dentin, which was embedded in acrylic resin, and randomly divided into three groups (n = 30/group) according to surface treatment: 1) no treatment (C and C*; control); 2) silver diamine fluoride with potassium iodide (SDF/KI and SDF/KI*; Riva Star); and 3) nano-hydroxyapatite (nHAp and nHAp*; PrevDent). The specimens were etched through the etch-and-rinse technique, followed by universal adhesive application and resin composite cylinders (2.38 mm in diameter × 3.5 mm high). The SBS was tested immediately (24 h after the restoration) and after thermocycling (*) (5000 cycles, 5 °C to 55 °C) at a 0.5 mm/min crosshead speed using a universal testing machine. A stereomicroscope was used to evaluate the mode of failure, and representative scanning electron microscopy (SEM) images were also acquired. Data normality was verified, and two-way ANOVA and Tukey's post hoc tests were performed for multiple comparisons (α = 0.05). The control group presented the highest SBS (27.10 MPa), while SDF/KI* had the lowest values (6.87 MPa). nHAp-based desensitizer exhibited higher SBS than SDF/KI for both immediate (22.6 MPa) and thermocycled (19.03 MPa) conditions. No intragroup difference was evidenced between immediate and thermocycled samples for any group. Most specimens for the C and nHAp groups presented mixed failure, while the SDF/KI groups presented comparable adhesive and mixed failures. The SBS of adhesive restorations after the application of desensitizing agents is material dependent, where SDF/KI reduces SBS values below the acceptable minimum bond strength, while the nHAp application meets the minimally required bond strength.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Humanos , Recubrimientos Dentinarios/química , Recubrimiento Dental Adhesivo/métodos , Dentina , Pirenos , Ensayo de Materiales , Cementos de Resina/química , Resistencia al Corte
17.
Odontology ; 112(2): 341-354, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37436660

RESUMEN

Our study aimed to evaluate the antibacterial activities and dentin bond strengths of silver nanoparticles (Ag NPs) and silver nano-graphene oxide nanocomposites (Ag@nGO NCs) produced by green and chemical synthesis methods added to the dental adhesive. Ag NPs were produced by green synthesis (biogenic) (B-Ag NPs) and chemical synthesis methods (C-Ag NPs) and deposited on nGO (nano-graphene oxide). Ag NPs and Ag@nGO NCs (0.05% w/w) were added to the primer and bond (Clearfil SE Bond). Group 1: control, Group 2: nGO, Group 3: B-Ag NPs, Group 4: B-Ag@nGO NCs, Group 5: C-Ag NPs, Group 6: C-Ag@nGO NCs. Streptococcus mutans (S. mutans) live/dead assay analysis, MTT metabolic activity test, agar disc diffusion test, lactic acid production, and colony forming units (CFUs) tests were performed. Bond strength values were determined by the microtensile bond strength test (µTBS). Failure types were determined by evaluating with SEM. Statistical analysis was performed using one-way ANOVA and two-way ANOVA (p < 0.05). There was a difference between the groups in the viable bacteria ratio and lactic acid production tests (p < 0.05). When the inhibition zone and S. mutans CFUs were evaluated, there was no difference between Group 3 and Group 4 (p > 0.05), but there was a difference between the other groups (p < 0.05). When the metabolic activity of S. mutans was evaluated, there was a difference between Group 1 and other groups, and between Group 2 and Group 5, and Group 6 (p < 0.05). There was no difference between the groups in the µTBS values (p > 0.05). As a result, although the antibacterial activity of B-Ag NPs and B-Ag@nGO Ag NPs obtained by green synthesis is lower than that of chemically synthesis obtained C-Ag NPs and C-Ag@nGO NCs, they provided higher antibacterial activity compared to the control group and did not reduce µTBS. The addition of biogenic Ag NPs to the adhesive system increased the antibacterial effect by maintaining the bond strength of the adhesive. Antibacterial adhesives can increase the restoration life by protecting the tooth-adhesive interface.


Asunto(s)
Recubrimiento Dental Adhesivo , Nanopartículas del Metal , Plata/farmacología , Plata/química , Antibacterianos/farmacología , Cementos de Resina/química , Streptococcus mutans , Ácido Láctico/metabolismo , Ácido Láctico/farmacología , Dentina , Resistencia a la Tracción , Ensayo de Materiales , Cementos Dentales/farmacología , Cementos Dentales/química , Recubrimientos Dentinarios/química
18.
Odontology ; 112(1): 158-168, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37173534

RESUMEN

Detachment is the major cause of failure of endodontic fibre posts. Hollow posts have been recently introduced to overcome such issue. The primary aim of this pilot study was to compare the push-out bond strength of hollow posts and traditional solid posts. Eight round-shaped single-canal premolars extracted for periodontal reason were selected as sample and equally randomized into two groups: (i) traditional solid fibre posts-TECH21xop and ii) hollow fibre posts-TECHOLE. A dual-curing self-adhesive cement (new TECHCEM) was used for posts placement. Six horizontal sections-two from each portion of the root (coronal, middle and apical)-were obtained from each sample root, yielding a total of 24 sections for each group. Push-out test was performed on the sections and bond strength values were compared between groups and within each group. Scanning electron microscope (SEM) fractographical analysis was conducted on each section. Additional SEM and EDX analyses were performed on new samples of both posts, to assess fibres density and distribution, and the chemical composition of the fibres and the matrix. Hollow posts showed a significantly higher push-out bond strength (6.36 ± 1.22 MPa) than solid posts (3.64 ± 1.62 MPa). Among the three root portions of the same group, there was no significant difference in bond strength. In both groups, the most frequent type of fracture was a mixed adhesive failure with the cement covering 0 to 50% of the post perimeter. Hollow post fibres appear more similar in size and have a more homogeneous distribution, compared to solid posts. The two post types also have different chemical compositions.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Cementos de Resina/química , Proyectos Piloto , Ensayo de Materiales , Análisis del Estrés Dental , Dentina , Vidrio
19.
Odontology ; 112(3): 917-928, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38194041

RESUMEN

To evaluate the effect of ultrasonic activation of the endodontic sealer on its intratubular penetration and bond strength to irradiated root dentin. Forty human teeth were distributed into 4 groups (n = 10), according to the radiation therapy (RT) exposure-70 Gy-and ultrasonic activation (UA) of the endodontic sealer: RT/UA-irradiated teeth and sealer UA; RT/no-UA-irradiated teeth and no sealer UA; no-RT/UA-non-irradiated teeth and sealer UA and no-RT/no-UA-non-irradiated teeth and no sealer UA. Push-out bond strength test was performed in a Universal Testing Machine. Failure modes and adhesive interface were analyzed under Scanning Electron Microscopy. The data were statistically compared (two-way-ANOVA and posthoc Games-Howell test; Fisher's exact test - α = 5%). The different experimental conditions (radiation and UA) and the root third had a significant effect on push-out bond strength, and the interaction of these factors was significant (p < 0.05). UA of the sealer significantly increased its bond strength to both irradiated and non-irradiated dentin (p < 0.05). The irradiated groups mostly presented adhesive-type failure of the sealer (p < 0.01). Regardless of the irradiation, the ultrasonically activated groups showed a more homogeneous adhesive interface, with the presence of sealer tags in greater density and depth. Ultrasonic activation enhanced the intratubular penetration and the bond strength of the endodontic sealer to irradiated dentin. The impact of ultrasonic activation of the endodontic sealer on teeth undergoing radiotherapy is a gap in the scientific literature that needs to be bridged.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Materiales de Obturación del Conducto Radicular , Humanos , Materiales de Obturación del Conducto Radicular/química , Recubrimiento Dental Adhesivo/métodos , Dentina/efectos de la radiación , Técnicas In Vitro , Análisis del Estrés Dental , Propiedades de Superficie , Ultrasonido , Raíz del Diente/efectos de la radiación
20.
Odontology ; 112(3): 657-671, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38381264

RESUMEN

This scoping review aimed to map whether the use of sonic and ultrasonic methods to activate the endodontic sealer improves the sealer filling quality in the root canal, considering the bond strength and intratubular penetration to the root dentin as evaluation criteria. The study protocol was prospectively registered and is available online ( https://osf.io/x5fma/ ). Reporting was based on PRISMA Extension for Scoping Reviews. The search was performed in Embase, PubMed, Scopus, and Web of Science. We selected studies without time and language restrictions that used sonic or ultrasonic methods to activate endodontic sealer, whose outcomes were bond strength and intratubular penetration. Three researchers independently selected the articles and collected data. Of 1422 articles, 19 were read in full and 13 studies were included. The vast majority of studies opted for direct activation of the endodontic sealer. The most investigated sealers were the epoxy resin-based sealers, and the ultrasonic activation method was the most explored. For the bond strength outcome, there was a trend toward higher values when the sealer was activated ultrasonically, but the findings seem to be divergent. The sonic activation was not effective for its intended purpose. For the outcome of intratubular penetration, the vast majority of studies indicate that the use of sonic and ultrasonic methods to activate the endodontic sealer is capable of increasing intratubular penetration. The use of sonic and ultrasonic methods to directly activate the endodontic sealer can increase the intratubular penetration of the sealer, but their benefits on the bond strength are uncertain.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/química , Humanos , Ultrasonido , Obturación del Conducto Radicular/métodos , Recubrimiento Dental Adhesivo/métodos , Sonicación
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda