Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 738
Filtrar
1.
BMC Med Imaging ; 24(1): 68, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38515044

RESUMEN

BACKGROUND: Contrast-enhanced ultrasound (CEUS) is considered as an efficient tool for focal liver lesion characterization, given it allows real-time scanning and provides dynamic tissue perfusion information. An accurate diagnosis of liver lesions with CEUS requires a precise interpretation of CEUS images. However,it is a highly experience dependent task which requires amount of training and practice. To help improve the constrains, this study aims to develop an end-to-end method based on deep learning to make malignancy diagnosis of liver lesions using CEUS. METHODS: A total of 420 focal liver lesions with 136 benign cases and 284 malignant cases were included. A deep learning model based on a two-dimensional convolution neural network, a long short-term memory (LSTM), and a linear classifier (with sigmoid) was developed to analyze the CEUS loops from different contrast imaging phases. For comparison, a 3D-CNN based method and a machine-learning (ML)-based time-intensity curve (TIC) method were also implemented for performance evaluation. RESULTS: Results of the 4-fold validation demonstrate that the mean AUC is 0.91, 0.88, and 0.78 for the proposed method, the 3D-CNN based method, and the ML-based TIC method, respectively. CONCLUSIONS: The proposed CNN-LSTM method is promising in making malignancy diagnosis of liver lesions in CEUS without any additional manual features selection.


Asunto(s)
Aprendizaje Profundo , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Medios de Contraste , Ultrasonografía/métodos
2.
BMC Med Imaging ; 24(1): 42, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38350842

RESUMEN

BACKGROUND: Parathyroid glands are important endocrine glands, and the identification of normal parathyroid glands is crucial for their protection. The aim of this study is to explore the sonographic characteristics of normal parathyroid glands and analyze the factors affecting their display. METHODS: Seven hundred three subjects who underwent physical examination at our hospital were included. The number, location, size, morphology, echogenicity and blood flow distribution of parathyroid glands were recorded. The ultrasound characteristics and display rate were also summarized. Meanwhile, shear wave elastography was performed in 50 cases to provide the stiffness measurements, and 26 cases received contrast-enhanced ultrasonography for the assessment of microcirculatory perfusion. Furthermore, we analyzed the factors affecting parathyroid display, including basic information of the subjects and ultrasound features of the thyroid. RESULTS: ① A total of 1038 parathyroid glands were detected, among which, 79.29% were hyperechoic, 20.71% were isoechoic, 88.15% were oval-shaped, and 86.71% had blood flow of grade 0-I. ② 81.79% of the subjects had at least one parathyroid gland detected. ③ The Emean, Emax, PI and AUC of the parathyroid glands were significantly lower than those of the adjacent thyroid tissue (P < 0.05). ④ The display of normal parathyroid glands was related to BMI, thyroid echogenicity and thyroid volume of the subjects (P < 0.05). CONCLUSIONS: Normal parathyroid glands tend to appear as oval-shaped hyperechoic nodules with blood flow of grade 0-I. BMI, thyroid echogenicity and thyroid volume are independent factors affecting the display of parathyroid glands.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Glándulas Paratiroides , Humanos , Glándulas Paratiroides/diagnóstico por imagen , Microcirculación , Ultrasonografía , Glándula Tiroides/diagnóstico por imagen
3.
J Ultrasound Med ; 43(3): 563-571, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38088445

RESUMEN

OBJECTIVES: Reporting contrast-enhanced ultrasound (CEUS) for focal liver masses in at risk patients is a challenging task. Traditionally used prose reporting (PR) is inconsistent and lacks standardization. We propose synoptic reporting (SR), encompassing algorithmic interpretation and liver imaging and reporting data system (LI-RADS) categorization. METHODS: A software worksheet from Kailo Medical (Melbourne, AU), incorporates the CEUS algorithm for liver interpretation and CEUS LI-RADS categorization. Part 1. Feasibility of SR: twenty participants of varying experience were presented a brief lecture on SR, algorithmic approach to liver mass interpretation, and CEUS LI-RADS categorization. Ten representative liver masses were shown as unknown cases. Participants inputted data into SR worksheets. Results and LI-RADS category were generated solely by SR. Data were categorized as "correct" or "incorrect." Part 2. Prospective Analysis: Ninety-one patients for SR and 56 for PR, all were tested for completeness, efficiency, and user satisfaction. RESULTS: Part 1: Junior participants, pass rate 81.6%, and senior participants, pass rate 83.3% showed no difference in performance. Part 2: Completeness: SR 98.4% and PR 87.0%. Efficiency: Average total time to completion: SR 11 minutes and PR 20 minutes. User satisfaction: Ultrasound technologists, all referring physicians, and six out of seven radiologists preferred SR over PR. Major benefits cited were total time saved, consistency and accuracy in documentation, and report completeness. CONCLUSIONS: SR is a reliable and useful tool in clinical practice to report liver masses on ultrasound and assign an appropriate LI-RADS categorization and management pathway. This ultimately improves communication with referring clinicians and leads to better patient outcomes.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Estudios Prospectivos , Medios de Contraste , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
4.
J Ultrasound Med ; 43(4): 697-711, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38189176

RESUMEN

OBJECTIVES: To determine the added diagnostic value of contrast-enhanced ultrasound (CEUS) in pediatric chest abnormalities by comparing interpretation of CEUS studies and confidence level to conventional US studies. METHODS: CEUS studies in patients with a variety of clinically suspected chest abnormalities performed between 2016 and 2020 were reviewed and compared to same-day conventional US studies. Examinations were independently interpreted by 4 radiologists blinded to clinical and other imaging data. Rater confidence was classified as low, moderate, or high. Diagnostic accuracy was determined by comparing image interpretation to patient outcome as the ground truth. Interobserver agreement was also assessed. RESULTS: Sixteen patients (10 male) with 18 CEUS studies were included. Median rater agreement with ground truth was significantly higher for CEUS (100%) than conventional US (50%; P = .004). Median rater confidence was high (3.0) for CEUS, and low-moderate (1.5) for conventional US (P < .001). CEUS sensitivity (54.6-81.8%) and specificity (63.4-100.0%) were greater than conventional US (45.5-72.7% and 12.5-63.5%, respectively). CEUS false positives (0-4) and false negatives (2-5) were fewer than conventional US (4-7 and 3-6, respectively). Except for one rater pair where agreement was substantial (κ = .78, P < .01), inter-rater agreement for CEUS for all other rater pairs was nonsignificant (κ = .25-0.51, P ≥ .07). Agreement for conventional US was moderate and statistically significant for 3 rater pairs (κ = .55-0.78) and nonsignificant for the remaining 3 rater pairs (P ≥ .06). CONCLUSIONS: CEUS adds diagnostic value to the assessment of a variety of chest abnormalities. The data support further evaluation of the role of CEUS as a non-invasive, problem-solving technique in children.


Asunto(s)
Medios de Contraste , Aumento de la Imagen , Humanos , Masculino , Adolescente , Niño , Proyectos Piloto , Ultrasonografía/métodos , Aumento de la Imagen/métodos , Examen Físico , Sensibilidad y Especificidad
5.
Radiol Med ; 129(4): 536-548, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38512611

RESUMEN

Although contrast-enhanced ultrasound (CEUS) is a widespread and easily manageable technique, image interpretation errors can occur due to the operator's inexperience and/or lack of knowledge of the frequent pitfalls, which may cause uncertain diagnosis and misdiagnosis. Indeed, knowledge of the basic physical and technical principles of ultrasound is needed both to understand sonographic image findings and to evaluate the potential and limits of the method. Like the B-mode ultrasound, the quality of the CEUS examination is also subject not only to the adequate manual skill of the operator but also to his/her deep knowledge of the technique which improves the quality of the image helping avoid misleading artifacts. In this review, the main parameters influencing a CEUS examination will be described by taking into account the most common errors and pitfalls and their possible solutions.


Asunto(s)
Artefactos , Medios de Contraste , Humanos , Masculino , Femenino , Ultrasonografía/métodos , Errores Diagnósticos
6.
Vet Radiol Ultrasound ; 65(3): 208-218, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38363188

RESUMEN

B-mode ultrasound is routinely performed to evaluate the prostate gland in neutered dogs, although, the detection of malignancies may be challenging. Contrast-enhanced ultrasound (CEUS) has shown to be useful for the assessment of prostatic perfusion in normal and diseased dogs, although the interpretation of contrast ultrasonographic features may still be subjective. A quantitative tool for evaluating prostatic perfusion might improve the reliability of the results in terms of early detection of prostate neoplasia in neutered dogs. The present study aimed to evaluate the applicability of a postprocessing analysis tool to CEUS of the prostate in healthy neutered dogs, to provide quantitative measurements, and to study the influence of individual characteristics on prostatic regression. Twenty-three neutered dogs underwent a B-mode and CEUS examination of the prostate to acquire data about prostatic morphology and microcirculation. The prostate was imaged using a 5-7.5 MHz linear transducer and contrast was administered intravenously. Videoclips were analyzed by using Qontrast software and a postprocessing digital analysis tool (ImageJ) to measure perfusion peak intensity, time to peak, and vascularization ratio at the moment of the peak, which were then related to body weight, age, and time elapsed since orchiectomy. Correlation tests revealed higher vascularization in younger compared with older dogs (P < .05) and in smaller compared with larger dogs (P < .05). Time elapsed since orchiectomy (P > .05) did not affect prostatic perfusion. Contrast-enhanced ultrasound and the postprocessing analysis tool ImageJ allowed analysis of vascular perfusion in all dogs and have the potential to improve the diagnostic possibilities for andrological examination.


Asunto(s)
Medios de Contraste , Próstata , Ultrasonografía , Perros , Animales , Masculino , Próstata/irrigación sanguínea , Próstata/diagnóstico por imagen , Ultrasonografía/veterinaria , Procesamiento de Imagen Asistido por Computador
7.
Medicina (Kaunas) ; 60(3)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38541101

RESUMEN

Background and Objectives: Unstable atherosclerotic plaque in the arteries is one of the main risk factors for cerebral ischemia. Duplex ultrasound is a frequently used diagnostic method, but it has some limitations for microvascularization and neovascularization evaluation. The aim of this review was to evaluate the role of the new multiparametric US method-contrast-enhanced ultrasound (CEUS)-in atherosclerotic plaque instability verification. Materials and Methods: Original studies, reviews, and meta-analyses were included in this article. A total of 53 studies were retrieved; 29 were included in this study. Results: Carotid artery CEUS as a part of the multiparametric ultrasound method shows promising results and provides additional characteristics of soft- and high-risk atherosclerotic plaques; it can be advised in clinical practice for patients with carotid artery soft- and high-risk plaques. However, there are some limitations, such as extensive calcinosis with important acoustic shadows in carotid atherosclerotic plaque neovascularization diagnostics by CEUS. The added value of CEUS in the characterization of atherosclerotic plaque is that it indicates regions with high neovascularization and visualizes ulcerations on plaque surfaces, suggestive of increased instability risk.


Asunto(s)
Estenosis Carotídea , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Medios de Contraste , Arterias Carótidas/diagnóstico por imagen , Ultrasonografía
8.
Medicina (Kaunas) ; 60(3)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38541175

RESUMEN

Hepatic hemangiomas are the most common benign liver tumors. Typically, small- to medium-sized hemangiomas are asymptomatic and discovered incidentally through the widespread use of imaging techniques. Giant hemangiomas (>5 cm) have a higher risk of complications. A variety of imaging methods are used for diagnosis. Cavernous hemangioma is the most frequent type, but radiologists must be aware of other varieties. Conservative management is often adequate, but some cases necessitate targeted interventions. Although surgery was traditionally the main treatment, the evolution of minimally invasive procedures now often recommends transarterial chemoembolization as the treatment of choice.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Hemangioma Cavernoso , Hemangioma , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patología , Carcinoma Hepatocelular/terapia , Imagen por Resonancia Magnética/métodos , Hemangioma/diagnóstico por imagen , Hemangioma/terapia , Hemangioma Cavernoso/diagnóstico por imagen , Hemangioma Cavernoso/terapia
9.
Eur J Orthop Surg Traumatol ; 34(1): 371-378, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37540246

RESUMEN

PURPOSE: Medial knee osteoarthritis can be treated with medial open wedge high tibial osteotomy (OWHTO). We sought to investigate osseous consolidation of the osteotomy with and without autologous bone grafts (ABG) to detect possible benefits of ABG in osseous healing and functional outcome. METHODS: In this prospective study, patients without graft transplantation were compared to those receiving ABG after medial OWHTO. They were followed up 6 weeks, 12 weeks, 6 months and 12 months postoperatively. Radiographic progress of consolidation, clinical scores, contrast-enhanced ultrasound (CEUS) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) were assessed at each appointment. RESULTS: A total of 35 patients were enrolled, 20 without and 15 with graft transplantation. Radiologic evaluation showed a significantly earlier consolidation of the osteotomy gaps (p = 0.012) in patients with ABG, resulting in a significantly higher rate of consolidation 12 months after surgery (60% without bone graft vs. 100% with bone graft, p = 0.006). At 6 weeks as well as 6-month follow-up, a tendency of earlier consolidation with ABG was apparent, but not statistically significant (6 weeks: 50% vs. 80%, p = 0.089; 6 months: 30% vs. 60%, p = 0.097). CEUS and DCE-MRI showed physiological perfusion of the osteotomy gaps in both groups. A tendency to better function and less pain in patients with ABG was recognizable. CONCLUSION: In our study, autologous bone grafting evocated earlier osseous consolidation after medial OWHTO and showed a tendency to a better functional outcome.


Asunto(s)
Trasplante Óseo , Osteoartritis de la Rodilla , Humanos , Trasplante Óseo/métodos , Estudios Prospectivos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Rodilla , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Osteotomía/métodos , Tibia/diagnóstico por imagen , Tibia/cirugía , Estudios Retrospectivos
10.
Breast Cancer Res ; 25(1): 61, 2023 05 30.
Artículo en Inglés | MEDLINE | ID: mdl-37254149

RESUMEN

BACKGROUND: Multiparametric magnetic resonance imaging (MP-MRI) has high sensitivity for diagnosing breast cancers but cannot always be used as a routine diagnostic tool. The present study aimed to evaluate whether the diagnostic performance of perfluorobutane (PFB) contrast-enhanced ultrasound (CEUS) is similar to that of MP-MRI in breast cancer and whether combining the two methods would enhance diagnostic efficiency. PATIENTS AND METHODS: This was a head-to-head, prospective, multicenter study. Patients with breast lesions diagnosed by US as Breast Imaging Reporting and Data System (BI-RADS) categories 3, 4, and 5 underwent both PFB-CEUS and MP-MRI scans. On-site operators and three reviewers categorized the BI-RADS of all lesions on two images. Logistic-bootstrap 1000-sample analysis and cross-validation were used to construct PFB-CEUS, MP-MRI, and hybrid (PFB-CEUS + MP-MRI) models to distinguish breast lesions. RESULTS: In total, 179 women with 186 breast lesions were evaluated from 17 centers in China. The area under the receiver operating characteristic curve (AUC) for the PFB-CEUS model to diagnose breast cancer (0.89; 95% confidence interval [CI] 0.74, 0.97) was similar to that of the MP-MRI model (0.89; 95% CI 0.73, 0.97) (P = 0.85). The AUC of the hybrid model (0.92, 95% CI 0.77, 0.98) did not show a statistical advantage over the PFB-CEUS and MP-MRI models (P = 0.29 and 0.40, respectively). However, 90.3% false-positive and 66.7% false-negative results of PFB-CEUS radiologists and 90.5% false-positive and 42.8% false-negative results of MP-MRI radiologists could be corrected by the hybrid model. Three dynamic nomograms of PFB-CEUS, MP-MRI and hybrid models to diagnose breast cancer are freely available online. CONCLUSIONS: PFB-CEUS can be used in the differential diagnosis of breast cancer with comparable performance to MP-MRI and with less time consumption. Using PFB-CEUS and MP-MRI as joint diagnostics could further strengthen the diagnostic ability. Trial registration Clinicaltrials.gov; NCT04657328. Registered 26 September 2020. IRB number 2020-300 was approved in Chinese PLA General Hospital. Every patient signed a written informed consent form in each center.


Asunto(s)
Neoplasias de la Mama , Imágenes de Resonancia Magnética Multiparamétrica , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Medios de Contraste , Sensibilidad y Especificidad , Estudios Prospectivos , Ultrasonografía Mamaria/métodos , Imagen por Resonancia Magnética/métodos
11.
World J Urol ; 41(3): 679-685, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35986781

RESUMEN

PURPOSE: Renal cysts comprise benign and malignant entities. Risk assessment profits from CT/MRI imaging using the Bosniak classification. While Bosniak-IIF, -III, and -IV cover complex cyst variants, Bosniak-IIF and -III stand out due to notorious overestimation. Contrast-enhanced ultrasound (CEUS) is promising to overcome this deficit but warrants standardization. This study addresses the benefits of a combined CEUS and CT/MRI evaluation of renal cysts. The study provides a realistic account of kidney tumor boards' intricacies in trying to validate renal cysts. METHODS: 247 patients were examined over 8 years. CEUS lesions were graded according to CEUS-Bosniak (IIF, III, IV). 55 lesions were resected, CEUS-Bosniak- and CT/MRI-Bosniak-classification were correlated with histopathological diagnosis. Interobserver agreement between the classifications was evaluated statistically. 105 lesions were followed by ultrasound, and change in CEUS-Bosniak-types and lesion size were documented. RESULTS: 146 patients (156 lesions) were included. CEUS classified 67 lesions as CEUS-Bosniak-IIF, 44 as CEUS-Bosniak-III, and 45 as CEUS-Bosniak-IV. Histopathology of 55 resected lesions revealed benign cysts in all CEUS-Bosniak-IIF lesions (2/2), 40% of CEUS-Bosniak-III and 8% of CEUS-Bosniak-IV, whereas malignancy was uncovered in 60% of CEUS-Bosniak-III and 92% of CEUS-Bosniak-IV. Overall, CEUS-Bosniak-types matched CT/MRI-Bosniak types in 58% (fair agreement, κ = 0.28). CEUS-Bosniak resulted in higher stages than CT/MRI-Bosniak (40%). Ultrasound follow-up of 105 lesions detected no relevant differences between CEUS-Bosniak-types concerning cysts size. 99% of lesions showed the same CEUS-Bosniak-type. CONCLUSION: The CEUS-Bosniak classification is an essential tool in clinical practice to differentiate and monitor renal cystic lesions and empowers diagnostic work-up and patient care.


Asunto(s)
Quistes , Enfermedades Renales Quísticas , Neoplasias Renales , Humanos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Riñón/diagnóstico por imagen , Riñón/patología , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Enfermedades Renales Quísticas/diagnóstico por imagen , Enfermedades Renales Quísticas/patología , Quistes/patología
12.
BMC Gastroenterol ; 23(1): 173, 2023 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-37217841

RESUMEN

OBJECTIVE: To evaluate the value of transrectal ultrasound (TRUS) guided biopsy in endoscopy negative biopsy patients with rectal lesions. METHODS: 150 endoscopy negative biopsy result rectal lesions adopted the transrectal ultrasound-guided biopsy. Based on whether the patients received contrast-enhanced ultrasound examination or not before the biopsies, all enrolled cases were divided into TRUS guided group and contrast-enhanced TRUS (CE-TRUS) guided group, and the safety and diagnostic performances were analyzed retrospectively. RESULTS: We obtained adequate specimens in the majority of cases (98.7%,148/150); There were no complications identified in our study. 126 patients received contrast-enhanced TRUS examination before biopsy to evaluate vascular perfusion and necrosis. The sensitivity, specificity, PPV, NPV, and overall accuracy of all biopsies were 89.1%, 100%,100%, 70.4%, and 91.3% respectively; The sensitivity, specificity, PPV, NPV, and accuracy for TRUS-guided biopsy and CE-TRUS guided biopsy were 73.7%, 100%,100%, 50%,79.2% and 92.1%,100%,100%,75%,93.6% separately; The increase in correct diagnoses was significant (p < 0.05) between TRUS guided biopsy and CE-TRUS guided biopsy. CONCLUSION: TRUS-guided biopsy is a reliable procedure that can be augmented by endoscopic biopsy techniques if the biopsy yields negative results. CE-TRUS might assist in the location of the biopsy and decrease sampling errors.


Asunto(s)
Recto , Ultrasonografía Intervencional , Humanos , Estudios Retrospectivos , Biopsia , Ultrasonografía , Biopsia Guiada por Imagen/métodos
13.
BMC Vet Res ; 19(1): 180, 2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37777757

RESUMEN

BACKGROUND: Sepsis is a condition characterized by organic dysfunction, leading to hemodynamic instability and high morbidity and mortality rates in humans and animals. Early identification of perfusion changes and appropriate management of sepsis are crucial for improving patient prognosis. Currently, the Systemic Inflammatory Response Syndrome (SIRS) and Sequential Organ Failure Assessment (SOFA) scores are widely studied for sepsis identification and evaluation of organ dysfunction. However, these scores do not assess gastrointestinal involvement, which is common in this condition. Contrast-enhanced ultrasound (CEUS) and Doppler have been considered promising diagnostic techniques for detecting changes in vascularization and microcirculation in a non-invasive and safe manner, particularly in the gastrointestinal system. This study aimed to evaluate duodenal perfusion using CEUS, as well as abdominal aortic and cranial mesenteric artery blood flow using Doppler ultrasound, and systolic arterial pressure (SAP) in 17 bitches with pyometra and in 10 healthy animals. RESULTS: The variables were compared between the pyometra and control groups, as well between patients with and without sepsis determined by the SOFA or SIRS scores. Pyometra was found to cause a reduction in abdominal aortic blood flow volume, aortic peak systolic velocity, and resistivity index as evaluated by Doppler ultrasound. Patients with sepsis according to the SOFA criteria only presented lower SAP. In contrast, sepsis animals identified by the SIRS score exhibited lower SAP, aortic peak systolic velocity, aortic blood flow volume, and aortic resistivity index and additionally, higher peak intensity of contrast in the duodenal wall. CONCLUSIONS: Pyometra causes a reduction in abdominal aortic blood flow, which is more pronounced in animals with sepsis identified by the SIRS criteria. These animals also exhibited a decrease in systolic blood pressure and an increase in duodenal perfusion, as evident by CEUS. However, these changes were not observed in patients with sepsis identified by the SOFA criteria. The alterations in intestinal perfusion observed in animals with sepsis indicate the presence of inflammation or dysfunction. In this regard, CEUS proves to be a valuable technique for detecting subtle changes in tissue hemodynamics that may not be apparent in conventional exams.


Asunto(s)
Enfermedades de los Perros , Piómetra , Sepsis , Femenino , Humanos , Animales , Perros , Piómetra/veterinaria , Sepsis/diagnóstico por imagen , Sepsis/veterinaria , Síndrome de Respuesta Inflamatoria Sistémica/diagnóstico por imagen , Síndrome de Respuesta Inflamatoria Sistémica/veterinaria , Ultrasonografía Doppler , Pronóstico , Perfusión/veterinaria , Estudios Retrospectivos , Enfermedades de los Perros/diagnóstico por imagen
14.
J Ultrasound Med ; 42(1): 247-253, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35579375

RESUMEN

Hemoperitoneum in cirrhosis is a life-threatening condition that requires emergent evaluation. Contrast-enhanced ultrasound (CEUS) permits multiple dynamic characterizations of abdominal structures through all vascular phases, and contrast extravasation or the presence of microbubbles in the ascites could be a sensitive tool. We reviewed 13 patients with cirrhosis that underwent CEUS due to high suspicion for intra-abdominal bleeding. In 10 cases, CEUS demonstrated extravasation of contrast, including 2 instances where CEUS detected active bleeding despite negative computed tomography. These data support further study of CEUS in direct comparison to other imaging modalities in this clinical context.


Asunto(s)
Medios de Contraste , Hemoperitoneo , Humanos , Cirrosis Hepática , Ultrasonografía , Extravasación de Materiales Terapéuticos y Diagnósticos
15.
J Ultrasound Med ; 42(11): 2603-2614, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37401549

RESUMEN

OBJECTIVES: In high-BMI patients with and without fatty liver, we evaluate performance of a commercially available specially designed ultrasound probe (SDP) for scanning at depth. Greyscale and contrast-enhanced ultrasound (CEUS) capability of SDP for parenchymal assessment and liver mass characterization, emphasizing HCC, is compared with standard curvilinear probes. METHODS: This retrospective study included 60 patients. Fifty-five with measured BMI included 46/55 (84%) overweight or obese, and 9/55(16%) in the normal range with severe fatty liver. Fifty-six patients with focal liver abnormality included 37 with a mass and 19 with post-ablative treatment site. Masses included 23 confirmed malignancies, 15 HCC, 4 ICC, and 4 metastases. SDP followed suboptimal ultrasound using a standard probe. Images with varying fat content were compared for depth of penetration on greyscale and ability of CEUS to diagnose tumors. RESULTS: SDP showed statistically significant improvement P = <.05 in CEUS penetration for all degrees of fatty liver (mild, moderate, and severe). In malignant tumors, SDP improved detection of lesion washout in the portal venous/late phase (PVP/LP) at depth >10 cm, and in all malignant masses (P < .05). Fifteen confirmed deep HCC showed arterial phase hyperenhancement on standard probe in 10/15 (67%) and 15/15 (100%) on SDP. PVP/LP washout on standard probe was shown in 4/15 (26%) and on SDP, 14/15, (93%). Therefore, 93% of LR-5 tumors were diagnosed with SDP. Removing necessity for biopsy. CONCLUSIONS: Metabolic syndrome and obesity challenge ultrasound, especially CEUS. SDP overcame limitations of standard probes for CEUS penetration especially in fatty liver. SDP was optimal for the liver mass characterization by detecting washout.

16.
J Ultrasound Med ; 42(5): 963-968, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36634009

RESUMEN

PURPOSE: To determine the natural history and necessity of long-term follow-up of renal masses that do not demonstrate enhancement on contrast-enhanced ultrasound (CEUS). METHODS: This retrospective single-center study was approved by our local IRB and is HIPAA compliant. Exactly 405 patients with 620 non-enhancing renal masses on CEUS from a previously reported study were followed for up to 10 years. Techniques and equipment are described in the original manuscript. Patient charts and imaging studies were reviewed for the change in features. There were 117 (18.6%) patients lost to follow-up leading to 341 patients with 512 lesions. The lesion size, patient age, number of lesions per patient, and Bosniak class assigned at the initial examination was recorded. RESULTS: Mean patient age was 66 ± 12.6 years (range 17-95 years). Average time of follow-up was 58.9 ± 41.7 months (range 1-207 months). There was a mean of 1.5 ± 1.0 lesions per patient (range 1-7 lesions). Lesion size was 24.9 ± 18.2 mm (range 3-161 mm). There were 276 (53.9%) patients with >5-year follow-up and 78 (15.2%) patients with >10-year follow-up. The probability of change within 5 years was 0% (95% CI: 0-0.37 per 100PY) and 10 years 0% (95% CI: 0.0-0.18 per 100PY). Two lesions (0.4%) resolved by 60 months. Five lesions (1.0%) decreased in size. Four lesions (0.8%) increased in size >20% during the follow-up period but remained benign on subsequent imaging. CONCLUSION: Any non-enhancing renal mass on CEUS can be classified as benign.


Asunto(s)
Neoplasias Renales , Tomografía Computarizada por Rayos X , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Ultrasonografía/métodos , Neoplasias Renales/diagnóstico por imagen
17.
J Ultrasound Med ; 42(11): 2501-2511, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37269244

RESUMEN

OBJECTIVES: The present study aimed to determine the feasibility of the American College of Radiology's (ACR) contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) (version 2017) in examinations using Sonazoid and compare its diagnostic performance with that of modified LI-RADS in patients at high risk of hepatocellular carcinoma (HCC). METHODS: This retrospective study's sample population consisted of 137 participants with a total of 140 nodules who underwent CEUS with Sonazoid and pathological confirmation via surgery or biopsy from January 2020 to February 2022. The lesions were evaluated and classified based on the reference standards (ie, ACR CEUS LI-RADS and modified LI-RADS). The overall diagnostic capabilities of the two systems were evaluated in terms of accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% confidence intervals (CIs). RESULTS: The participants had a median age of 51 years and an interquartile range of 43-58 years. Regarding LR-5 as a predictor of HCC, the accuracy results of the ACR LI-RADS and modified LI-RADS algorithms were 72.9 and 71.4%, respectively (P = .50). The sensitivity of both systems was the same (69.7%; 95% CI: 60.7-77.8%). Regarding LR-M as a predictor of non-HCC malignancy, the diagnostic performance of the algorithms was the same, with accuracy and sensitivity results of 76.4 and 73.3%, respectively (95% CI: 44.9-92.2%). CONCLUSION: The findings indicate that modified LI-RADS had a moderate level of diagnostic performance for HCC in examinations using Sonazoid, which was comparable to ACR LI-RADS.

18.
World J Surg Oncol ; 21(1): 143, 2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37158920

RESUMEN

OBJECTIVE: This study evaluated the identification efficiency of contrast-enhanced ultrasound (CEUS) for sentinel lymph nodes (SLN) to accurately represent the axillary node status in early-stage breast cancer. METHOD: In total, 109 consecutive consenting patients with clinically node-negative and T1-2 breast cancer were included in this study. All patients received CEUS to identify SLN before surgery, and a guidewire was deployed to locate SLN in those who were successfully explored by CEUS. The patients underwent sentinel lymph node biopsy (SLNB), and the blue dye was used to trace SLN during the surgery. The decision to perform axillary lymph node dissection (ALND) depended on the intraoperative pathological identification of SLN by CEUS (CE-SLN). The concordance rate of pathological status between CE-SLN and dyed SLN was calculated. RESULT: The CEUS detection rate was 96.3%; CE-SLN failed in 4 patients. Among the remaining 105 successful identifications, 18 were CE-SLN positive by intraoperative frozen section, and one with CE-SLN micrometastasis was diagnosed by paraffin section. No additional lymph node metastases were found in CE-SLN-negative patients. The concordance rate of pathological status between CE-SLN and dyed SLN was 100%. CONCLUSION: CEUS can accurately represent the status of axillary lymph nodes in patients with clinically node-negative and small tumor burden breast cancer.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Biopsia del Ganglio Linfático Centinela , Estudios Prospectivos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/cirugía , Colorantes , Ultrasonografía Intervencional
19.
Pediatr Surg Int ; 39(1): 106, 2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36757505

RESUMEN

BACKGROUND: Blunt abdominal trauma is a prevailing cause of pediatric morbidity and mortality. It constitutes the most frequent type of pediatric injuries. Contrast-enhanced sonography (CEUS) and contrast-enhanced computed tomography (CECT) are considered pivotal diagnostic modalities in hemodynamically stable patients. AIM: To report the experience in management of pediatric split liver and spleen injuries using CEUS and CECT. PATIENTS AND METHODS: This study included 246 children who sustained blunt abdominal trauma, and admitted and treated at three tertiary hospitals in the period of 5 years. Primary resuscitation was offered to all children based on the advanced trauma and life support (ATLS) protocol. A special algorithm for decision-making was followed. It incorporated the FAST, baseline ultrasound (US), CEUS, and CECT. Patients were treated according to the imaging findings and hemodynamic stability. RESULTS: All 246 children who sustained a blunt abdominal were studied. Patients' age was 10.5 ± 2.1. Road traffic accidents were the most common cause of trauma; 155 patients (63%). CECT showed the extent of injury in 153 patients' spleen (62%) and 78 patients' liver (32%), while the remaining 15 (6%) patients had both injuries. CEUS detected 142 (57.7%) spleen injury, and 67 (27.2%) liver injury. CONCLUSIONS: CEUS may be a useful diagnostic tool among hemodynamically stable children who sustained low-to-moderate energy isolated blunt abdominal trauma. It may be also helpful for further evaluation of uncertain CECT findings and follow-up of conservatively managed traumatic injuries.


Asunto(s)
Traumatismos Abdominales , Heridas no Penetrantes , Humanos , Niño , Bazo/diagnóstico por imagen , Bazo/lesiones , Estudios Retrospectivos , Medios de Contraste , Abdomen , Hígado/diagnóstico por imagen , Traumatismos Abdominales/diagnóstico por imagen , Traumatismos Abdominales/terapia , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/terapia
20.
J Clin Ultrasound ; 51(3): 543-559, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36515988

RESUMEN

This paper summarizes the main splenic emergencies and their ultrasonographic findings to orient appropriate patient management. US requires minimal preparation time and allows to examine the parenchyma and to detect intraperitoneal fluid collections, which may be indirect evidence of solid organ injuries. In this paper, we analyze the role of B-mode, Doppler and Contrast-Enhanced Ultrasound in the diagnosis of splenic emergencies, with a particular focus on splenic infarction, infection, traumatic injuries and vascular splenic anomalies.


Asunto(s)
Urgencias Médicas , Bazo , Humanos , Bazo/diagnóstico por imagen , Medios de Contraste , Abdomen , Ultrasonografía
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda