Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 503
Filtrar
1.
J Magn Reson Imaging ; 59(5): 1809-1817, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37427759

RESUMEN

BACKGROUND: In clinical practice, the right heart filling status is assessed using the respirophasic variation of the inferior vena cava (IVC) assessed by transthoracic echocardiography (TTE) showing moderate correlations with the catheter-based reference standard. PURPOSE: To develop and validate a similar approach using MRI. STUDY TYPE: Prospective. POPULATION: 37 male elite cyclists (mean age 26 ± 4 years). FIELD STRENGTH/SEQUENCE: Real-time balanced steady-state free-precession cine sequence at 1.5 Tesla. ASSESSMENT: Respirophasic variation included assessment of expiratory size of the upper hepatic part of the IVC and degree of inspiratory collapse expressed as collapsibility index (CI). The IVC was studied either in long-axis direction (TTE) or using two transverse slices, separated by 30 mm (MRI) during operator-guided deep breathing. For MRI, in addition to the TTE-like diameter, IVC area and major and minor axis diameters were also assessed, together with the corresponding CIs. STATISTICAL TESTS: Repeated measures ANOVA test with Bonferroni correction. Intraclass correlation coefficient (ICC) and Bland-Altman analysis for intrareader and inter-reader agreement. A P value <0.05 was considered statistically significant. RESULTS: No significant differences in expiratory IVC diameter were found between TTE and MRI, i.e., 25 ± 4 mm vs. 25 ± 3 mm (P = 0.242), but MRI showed a higher CI, i.e., 76% ± 14% vs. 66% ± 14% (P < 0.05). As the IVC presented a noncircular shape, i.e., major and minor expiratory diameter of 28 ± 4 mm and 21 ± 4 mm, respectively, the CI varied according to the orientation, i.e., 63% ± 27% vs. 75% ± 16%, respectively. Alternatively, expiratory IVC area was 4.3 ± 1.1 cm2 and showed a significantly higher CI, i.e., 86% ± 14% than diameter-based CI (P < 0.05). All participants showed a CI >50% with MRI versus 35/37 (94%) with TTE. ICC values ranged 0.546-0.841 for MRI and 0.545-0.704 for TTE. CONCLUSION: Assessment of the respirophasic IVC variation is feasible with MRI. Adding this biomarker may be of particular use in evaluating heart failure patients. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Imagen por Resonancia Cinemagnética , Vena Cava Inferior , Humanos , Masculino , Adulto Joven , Adulto , Vena Cava Inferior/diagnóstico por imagen , Estudios Prospectivos , Ecocardiografía , Corazón
2.
Langenbecks Arch Surg ; 409(1): 160, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758232

RESUMEN

PURPOSE: Intraoperative bleeding during hepatectomy is primarily controlled through anaesthesiological interventions or surgical techniques such as Pringle maneuver (PM). Infrahepatic IVC clamping (IIVCC) is an alternative surgical technique to reduce central venous pressure and prevent retrograde hepatic venous bleeding. The aim of the meta-analysis was to compare IIVCC+PM with PM alone in terms of intraoperative outcomes and perioperative complications. METHODS: Medline, Cochrane Library, Scopus, Web of Science, and EMBASE were searched for comparative studies till 16.04.2024, resulting in 679 articles, of which eight studies met inclusion criteria. Data on patient demographics, surgical technique, and perioperative outcomes was assessed. Cochrane Risk of Bias 2.0 (RoB 2.0) Tool and Newcastle-Ottawa Scale (NOS) were used for risk of bias assessment. RESULTS: Two randomized controlled trials, one prospective, and five retrospective cohort studies with 358 patients in IIVCC+PM and 397 patients in PM alone group were included. IIVCC+PM resulted in significantly greater CVP reduction, less intraoperative blood loss (MD (95% CI) = - 233.03 (- 360.48 to - 105.58), P < 0.001), and less intraoperative blood transfusion (OR (95% CI) = 0.38 (0.25 to 0.57), P < 0.001) compared to PM alone. The two groups had comparable total operative time, transection time and total intraoperative fluid infusion. Patients undergoing IIVCC+PM had significantly shorter length of stay (MD (95% CI) = - 0.63 days (- 1.21 to - 0.05 days), P = 0.03) and overall complication rates (OR (95% CI) = 0.63 (0.43-0.92), P = 0.02) compared to PM alone group. CONCLUSION: The utilization of IIVCC along with PM during liver resection may be beneficial in reducing intraoperative bleeding and blood transfusion without adversely influencing operative times or perioperative outcomes compared to PM alone.


Asunto(s)
Pérdida de Sangre Quirúrgica , Hepatectomía , Vena Cava Inferior , Hepatectomía/métodos , Hepatectomía/efectos adversos , Humanos , Vena Cava Inferior/cirugía , Pérdida de Sangre Quirúrgica/prevención & control , Pérdida de Sangre Quirúrgica/estadística & datos numéricos , Constricción , Tempo Operativo
3.
BMC Anesthesiol ; 24(1): 244, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39026144

RESUMEN

BACKGROUND: Conventional anesthesia used to reduce central venous pressure (CVP) during hepatectomy includes fluid restriction and vasodilator drugs, which can lead to a reduction in blood perfusion in vital organs and may counteract the benefits of low blood loss. In this study, we hypothesized that milrinone is feasible and effective in controlling low CVP (LCVP) during laparoscopic hepatectomy (LH). Compared with conventional anesthesia such as nitroglycerin, milrinone is beneficial in terms of intraoperative blood loss, surgical environment, hemodynamic stability, and patients' recovery. METHODS: In total, 68 patients undergoing LH under LCVP were randomly divided into the milrinone group (n = 34) and the nitroglycerin group (n = 34). Milrinone was infused with a loading dose of 10 µg/kg followed by a maintenance dose of 0.2-0.5 µg/kg/min and nitroglycerin was administered at a rate of 0.2-0.5 µg/kg/min until the liver lesions were removed. The characteristics of patients, surgery, intraoperative vital signs, blood loss, the condition of the surgical field, the dosage of norepinephrine, perioperative laboratory data, and postoperative complications were compared between groups. Blood loss during LH was considered the primary outcome. RESULTS: Blood loss during hepatectomy and total blood loss were significantly lower in the milrinone group compared with those in the nitroglycerin group (P < 0.05). Both the nitroglycerin group and milrinone group exerted similar CVP (P > 0.05). Nevertheless, the milrinone group had better surgical field grading during liver resection (P < 0.05) and also exhibited higher cardiac index and cardiac output during the surgery (P < 0.05). Significant differences were also found in terms of fluids administered during hepatectomy, urine volume during hepatectomy, total urine volume, and norepinephrine dosage used in the surgery between the two groups. The two groups showed a similar incidence of postoperative complications (P > 0.05). CONCLUSION: Our findings indicate that the intraoperative infusion of milrinone can help in maintaining an LCVP and hemodynamic stability during LH while reducing intraoperative blood loss and providing a better surgical field compared with nitroglycerin. TRIAL REGISTRATION: ChiCTR2200056891,first registered on 22/02/2022.


Asunto(s)
Pérdida de Sangre Quirúrgica , Presión Venosa Central , Hepatectomía , Laparoscopía , Milrinona , Nitroglicerina , Vasodilatadores , Humanos , Milrinona/administración & dosificación , Nitroglicerina/administración & dosificación , Hepatectomía/métodos , Masculino , Femenino , Método Doble Ciego , Laparoscopía/métodos , Persona de Mediana Edad , Presión Venosa Central/efectos de los fármacos , Vasodilatadores/administración & dosificación , Pérdida de Sangre Quirúrgica/prevención & control , Anciano , Adulto , Complicaciones Posoperatorias/prevención & control
4.
BMC Anesthesiol ; 24(1): 128, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38575875

RESUMEN

BACKGROUND: Elevated central venous pressure (CVP) is deemed as a sign of right ventricular (RV) dysfunction. We aimed to characterize the echocardiographic features of RV in septic patients with elevated CVP, and quantify associations between RV function parameters and 30-day mortality. METHODS: We retrospectively reviewed a cohort of septic patients with CVP ≥ 8 mmHg in a tertiary hospital intensive care unit. General characteristics and echocardiographic parameters including tricuspid annular plane systolic excursion (TAPSE), pulmonary vascular resistance (PVR) as well as prognostic data were collected. Associations between RV function parameters and 30-day mortality were assessed using Cox regression models. RESULTS: Echocardiography was performed in 244 septic patients with CVP ≥ 8 mmHg. Echocardiographic findings revealed that various types of abnormal RV function can occur individually or collectively. Prevalence of RV systolic dysfunction was 46%, prevalence of RV enlargement was 34%, and prevalence of PVR increase was 14%. In addition, we collected haemodynamic consequences and found that prevalence of systemic venous congestion was 16%, prevalence of RV-pulmonary artery decoupling was 34%, and prevalence of low cardiac index (CI) was 23%. The 30-day mortality of the enrolled population was 24.2%. In a Cox regression analysis, TAPSE (HR:0.542, 95% CI:0.302-0.972, p = 0.040) and PVR (HR:1.384, 95% CI:1.007-1.903, p = 0.045) were independently associated with 30-day mortality. CONCLUSIONS: Echocardiographic findings demonstrated a high prevalence of RV-related abnormalities (RV enlargement, RV systolic dysfunction and PVR increase) in septic patients with elevated CVP. Among those echocardiographic parameters, TAPSE and PVR were independently associated with 30-day mortality in these patients.


Asunto(s)
Sepsis , Disfunción Ventricular Derecha , Humanos , Presión Venosa Central , Ventrículos Cardíacos/diagnóstico por imagen , Estudios Retrospectivos , Ecocardiografía , Hipertrofia Ventricular Derecha , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha , Volumen Sistólico
5.
Eur Heart J ; 44(5): 368-380, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36148485

RESUMEN

AIMS: Albuminuria is common in patients with heart failure and associated with worse outcomes. The underlying pathophysiological mechanism of albuminuria in heart failure is still incompletely understood. The association of clinical characteristics and biomarker profile with albuminuria in patients with heart failure with both reduced and preserved ejection fractions were evaluated. METHODS AND RESULTS: Two thousand three hundred and fifteen patients included in the index cohort of BIOSTAT-CHF were evaluated and findings were validated in the independent BIOSTAT-CHF validation cohort (1431 patients). Micro-albuminuria and macro-albuminuria were defined as urinary albumincreatinine ratio (UACR) 30 mg/gCr and 300 mg/gCr in spot urines, respectively. The prevalence of micro- and macro-albuminuria was 35.4 and 10.0, respectively. Patients with albuminuria had more severe heart failure, as indicated by inclusion during admission, higher New York Heart Association functional class, more clinical signs and symptoms of congestion, and higher concentrations of biomarkers related to congestion, such as biologically active adrenomedullin, cancer antigen 125, and N-terminal pro-B-type natriuretic peptide (NT-proBNP) (all P 0.001). The presence of albuminuria was associated with increased risk of mortality and heart failure (re)hospitalization in both cohorts. The strongest independent association with log UACR was found for log NT-proBNP (standardized regression coefficient 0.438, 95 confidence interval 0.350.53, P 0.001). Hierarchical clustering analysis demonstrated that UACR clusters with markers of congestion and less with indices of renal function. The validation cohort yielded similar findings. CONCLUSION: In patients with new-onset or worsening heart failure, albuminuria is consistently associated with clinical, echocardiographic, and circulating biomarkers of congestion.


Asunto(s)
Albuminuria , Insuficiencia Cardíaca , Humanos , Pronóstico , Albuminuria/diagnóstico , Albuminuria/orina , Biomarcadores/orina , Péptido Natriurético Encefálico , Hospitalización , Fragmentos de Péptidos , Volumen Sistólico/fisiología
6.
Cardiol Young ; : 1-6, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38752303

RESUMEN

INTRODUCTION: Acute kidney injury is associated with worse outcomes after cardiac surgery. The haemodynamic goals to ameliorate kidney injury are not clear. Low post-operative renal perfusion pressure has been associated with acute kidney injury in adults. Inadequate oxygen delivery may also cause kidney injury. This study evaluates pressure and oximetric haemodynamics after paediatric cardiac surgery and their association with acute kidney injury. MATERIALS AND METHODS: Retrospective case-control study at a children's hospital. Patients were < 6 months of age who underwent a Society of Thoracic Surgery-European Association for Cardio-Thoracic Surgery Congenital Heart Surgery categories ≥ 3. Low renal perfusion pressure was time and depth below several tested thresholds. The primary outcome was serum creatine-defined acute kidney injury in the first 7 days. RESULTS: Sixty-six patients (median age 8 days) were included. Acute kidney injury occurred in 36%. The time and depth of renal perfusion pressure < 42 mmHg in the first 24 hours was greater in acute kidney injury patients (94 versus 35 mmHg*minutes of low renal perfusion pressure/hour, p = 0.008). In the multivariable model, renal perfusion pressure < 42 mmHg was associated with acute kidney injury (aOR: 2.07, 95%CI: 1.25-3.82, p = 0.009). Mean arterial pressure, central venous pressure, and measures of inadequate oxygen delivery were not associated with acute kidney injury. CONCLUSION: Periods of low renal perfusion pressure (<42 mmHg) in the first 24 post-operative hours are associated with acute kidney injury. Renal perfusion pressure is a potential modifiable target that may mitigate the impact of acute kidney injury after paediatric cardiac surgery.

7.
J Clin Monit Comput ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38954170

RESUMEN

This pilot study aimed to investigate the relation between cardio-respiratory parameters derived from Central Venous Pressure (CVP) waveform and Extubation Failure (EF) in mechanically ventilated ICU patients during post-extubation period. This study also proposes a new methodology for analysing these parameters during rest/sleep periods to try to improve the identification of EF. We conducted a prospective observational study, computing CVP-derived parameters including breathing effort, spectral analyses, and entropy in twenty critically ill patients post-extubation. The Dynamic Warping Index (DWi) was calculated from the respiratory component extracted from the CVP signal to identify rest/sleep states. The obtained parameters from EF patients and patients without EF were compared both during arbitrary periods and during reduced DWi (rest/sleep). We have analysed data from twenty patients of which nine experienced EF. Our findings may suggest significantly increased respiratory effort in EF patients compared to those successfully extubated. Our study also suggests the occurrence of significant change in the frequency dispersion of the cardiac signal component. We also identified a possible improvement in the differentiation between the two groups of patients when assessed during rest/sleep states. Although with caveats regarding the sample size, the results of this pilot study may suggest that CVP-derived cardio-respiratory parameters are valuable for monitoring respiratory failure during post-extubation, which could aid in managing non-invasive interventions and possibly reduce the incidence of EF. Our findings also indicate the possible importance of considering sleep/rest state when assessing cardio-respiratory parameters, which could enhance respiratory failure detection/monitoring.

8.
J Clin Monit Comput ; 38(2): 531-538, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38064134

RESUMEN

Microinfusions are commonly used for the administration of catecholamines, but start-up delays pose a problem for reliable and timely drug delivery. Recent findings show that venting of the syringe infusion pump with draining of fluid to ambient pressure before directing the flow towards the central venous catheter does not counteract start-up delays. With the aim to reduce start-up delays, this study compared fluid delivery during start-up of syringe infusion pumps without venting, with ambient pressure venting, and with central venous pressure (CVP)-adjusted venting. Start-up fluid delivery from syringe pumps using a microinfusion of 1 mL/h was assessed by means of liquid flow measurement at 10, 60, 180 and 360 s after opening the stopcock and starting the pump. Assessments were performed using no venting, ambient pressure venting or CVP-adjusted venting, with the pump placed either at zero, - 43 cm or + 43 cm level and exposed to a simulated CVP of 10 mmHg. Measured fluid delivery was closest to the calculated fluid delivery for CVP-adjusted venting (87% to 100% at the different timepoints). The largest deviations were found for ambient pressure venting (- 1151% to + 82%). At 360 s after start-up 72% to 92% of expected fluid volumes were delivered without venting, 46% to 82% with ambient pressure venting and 96% to 99% with CVP-adjusted venting. CVP-adjusted venting demonstrated consistent results across vertical pump placements (p = 0.485), whereas the other methods had significant variances (p < 0.001 for both). In conclusion, CVP-adjusted venting effectively eliminates imprecise drug delivery and start-up delays when using microinfusions.


Asunto(s)
Catéteres Venosos Centrales , Bombas de Infusión , Humanos , Diseño de Equipo , Catecolaminas , Sistemas de Liberación de Medicamentos
9.
J Clin Monit Comput ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38512359

RESUMEN

Transpulmonary pressure (PL) calculation requires esophageal pressure (PES) as a surrogate of pleural pressure (Ppl), but its calibration is a cumbersome technique. Central venous pressure (CVP) swings may reflect tidal variations in Ppl and could be used instead of PES, but the interpretation of CVP waveforms could be difficult due to superposition of heartbeat-induced pressure changes. Thus, we developed a digital filter able to remove the cardiac noise to obtain a filtered CVP (f-CVP). The aim of the study was to evaluate the accuracy of CVP and filtered CVP swings (ΔCVP and Δf-CVP, respectively) in estimating esophageal respiratory swings (ΔPES) and compare PL calculated with CVP, f-CVP and PES; then we tested the diagnostic accuracy of the f-CVP method to identify unsafe high PL levels, defined as PL>10 cmH2O. Twenty patients with acute respiratory failure (defined as PaO2/FiO2 ratio below 200 mmHg) treated with invasive mechanical ventilation and monitored with an esophageal balloon and central venous catheter were enrolled prospectively. For each patient a recording session at baseline was performed, repeated if a modification in ventilatory settings occurred. PES, CVP and airway pressure during an end-inspiratory and -expiratory pause were simultaneously recorded; CVP, f-CVP and PES waveforms were analyzed off-line and used to calculate transpulmonary pressure (PLCVP, PLf-CVP, PLPES, respectively). Δf-CVP correlated better than ΔCVP with ΔPES (r = 0.8, p = 0.001 vs. r = 0.08, p = 0.73), with a lower bias in Bland Altman analysis in favor of PLf-CVP (mean bias - 0.16, Limits of Agreement (LoA) -1.31, 0.98 cmH2O vs. mean bias - 0.79, LoA - 3.14, 1.55 cmH2O). Both PLf-CVP and PLCVP correlated well with PLPES (r = 0.98, p < 0.001 vs. r = 0.94, p < 0.001), again with a lower bias in Bland Altman analysis in favor of PLf-CVP (0.15, LoA - 0.95, 1.26 cmH2O vs. 0.80, LoA - 1.51, 3.12, cmH2O). PLf-CVP discriminated high PL value with an area under the receiver operating characteristic curve 0.99 (standard deviation, SD, 0.02) (AUC difference = 0.01 [-0.024; 0.05], p = 0.48). In mechanically ventilated patients with acute respiratory failure, the digital filtered CVP estimated ΔPES and PL obtained from digital filtered CVP represented a reliable value of standard PL measured with the esophageal method and could identify patients with non-protective ventilation settings.

10.
J Anesth ; 38(1): 77-85, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38091035

RESUMEN

PURPOSE: The purpose of this prospective single blinded randomized controlled trial was to find out whether goal-directed fluid therapy (GDFT) strategy in post-transection period in low central venous pressure (CVP) assisted laparoscopic hepatectomy (LH) has more benefit than traditional fluid strategy. METHODS: Between April 2020 and Dec 2021, patients who were scheduled for laparoscopic liver resection surgery were eligible to participate in the study. Patients were randomly divided into two groups: control group that received traditional fluid strategy in post-transection period in low CVP assisted laparoscopic hepatectomy and GDFT strategy group that received GDFT strategy in post-transection period. The primary outcome parameter is the incidence of postoperative complications. Secondary outcome parameters include perioperative clinical outcomes, postoperative clinical outcomes, length of hospital stay after surgery, postoperative lactic acid, fluids and vasoactive medications during the operation. RESULTS: A total of 159 patients in the control group and 160 patients in the GDFT were included. Two groups had no significant difference in the incidence of postoperative complications including pneumonia (P = 0.34), acute kidney injury (P = 0.72), hepatic insufficiency (P = 0.25), pleural effusion (P = 0.08) and seroperitoneum (P = 1.00), respectively. The amount of perioperative urine output is fewer in GDFT group than in the control group (P = 0.0354), while other perioperative variables and postoperative variables were comparable between two groups. CONCLUSIONS: The results show the implementation of GDFT strategy is not associated with fewer postoperative complications. GDFT strategy did not result in improved outcomes in low CVP-assisted laparoscopic hepatectomy.


Asunto(s)
Hepatectomía , Laparoscopía , Humanos , Presión Venosa Central , Objetivos , Estudios Prospectivos , Fluidoterapia/métodos , Complicaciones Posoperatorias/epidemiología
11.
Exp Physiol ; 108(12): 1560-1568, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37824038

RESUMEN

Compression sonography has been proposed as a method for non-invasive measurement of venous pressures during spaceflight, but initial reports of venous pressure measured by compression ultrasound conflict with prior reports of invasively measured central venous pressure (CVP). The aim of this study is to determine the agreement of compression sonography of the internal jugular vein (IJVP) with invasive measures of CVP over a range of pressures relevant to microgravity exposure. Ten healthy volunteers (18-55 years, five female) completed two 3-day sessions of supine bed rest to simulate microgravity. IJVP and CVP were measured in the seated position, and in the supine position throughout 3 days of bed rest. The range of CVP recorded was in line with previous reports of CVP during changes in posture on Earth and in microgravity. The correlation between IJVP and CVP was poor when measured during spontaneous breathing (r = 0.29; R2  = 0.09; P = 0.0002; standard error of the estimate (SEE) = 3.0 mmHg) or end-expiration CVP (CVPEE ; r = 0.19; R2  = 0.04; P = 0.121; SEE = 3.0 mmHg). There was a modest correlation between the change in CVP and the change in IJVP for both spontaneous ΔCVP (r = 0.49; R2  = 0.24; P < 0.0001) and ΔCVPEE (r = 0.58; R2  = 0.34; P < 0.0001). Bland-Altman analysis of IJVP revealed a large positive bias compared to spontaneous breathing CVP (3.6 mmHg; SD = 4.0; CV = 85%; P < 0.0001) and CVPEE (3.6 mmHg; SD = 4.2; CV = 84%; P < 0.0001). Assessment of absolute IJVP via compression sonography correlated poorly with direct measurements of CVP by invasive catheterization over a range of venous pressures that are physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time. NEW FINDINGS: What is the central question of this study? Compression sonography has been proposed as a novel method for non-invasive measurement of venous pressures during spaceflight. However, the accuracy has not yet been confirmed in the range of CVP experienced by astronauts during spaceflight. What is the main finding and its importance? Our data show that compression sonography of the internal jugular vein correlates poorly with direct measurement of central venous pressures in a range that is physiologically relevant to spaceflight. However, compression sonography showed modest utility for tracking changes in venous pressure over time.


Asunto(s)
Reposo en Cama , Venas Yugulares , Humanos , Femenino , Venas Yugulares/diagnóstico por imagen , Venas Yugulares/fisiología , Presión Venosa , Presión Venosa Central/fisiología , Ultrasonografía
12.
Scand J Gastroenterol ; 58(5): 497-504, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36384398

RESUMEN

Background: The optimal occlusion and reperfusion time to balance blood loss and ischemia-reperfusion injury to the remnant liver remains unclear. The aim was to explore the clinical impact of prolonging the hepatic hilum occlusion time from 15 to 20 min using the intermittent Pringle maneuver (IPM) combined with controlled low central venous pressure (CLCVP).Methods: A total of 151 patients were included and divided into an experimental group (Group 20,75 cases) and a control group (Group 15,76 cases). In both groups, the hepatic hilum was blocked by the IPM combined with CLCVP to control intraoperative hepatic cross-sectional bleeding. The preoperative, intraoperative and postoperative parameters and safety were compared between the two groups.Results: There were no significant differences between the two groups in the postoperative aminotransferase serum levels (p > 0.05). However, the operation time in Group 20 was significantly lower than that in Group 15 (222.4 ± 87.8 vs. 250.7 ± 94.5 min, p < 0.05). The procalcitonin at 1 day after operation in Group 20 was lower than that at 1 day after operation in Group 15 (0.78 ± 0.66 vs. 1.45 ± 1.33 ng/mL, p < 0.05). There was no significant difference in the incidence of postoperative bleeding, postoperative bile leakage and postoperative infection between the two groups (p > 0.05).Conclusions: For patients with hepatocellular carcinoma after hepatitis B cirrhosis, it is feasible and safe to prolong the hepatic hilum occlusion time from 15 to 20 min using the IPM combined with CLCVP.


Asunto(s)
Carcinoma Hepatocelular , Hepatitis B , Neoplasias Hepáticas , Enfermedades Vasculares , Humanos , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Presión Venosa Central , Estudios Transversales , Hepatectomía , Estudios Retrospectivos , Pérdida de Sangre Quirúrgica/prevención & control , Hígado/patología , Cirrosis Hepática/patología , Enfermedades Vasculares/patología
13.
Langenbecks Arch Surg ; 408(1): 455, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38049533

RESUMEN

PURPOSE: Uncontrollable bleeding remained problematic in anatomical hepatectomy exposing hepatic veins. Based on the inferior vena cava (IVC) anatomy, we attempted to analyze the hemodynamic and surgical effects of the combined IVC-partial clamp (PC) accompanied with the Trendelenburg position (TP). METHODS: We prospectively assessed 26 consecutive patients who underwent anatomical hepatectomies exposing HV trunks between 2020 and 2023. Patients were divided into three groups: use of IVC-PC (group 1), no use of IVC-PC (group 2), and use of IVC-PC accompanied with TP (group 3). In 10 of 26 patients (38%), hepatic venous pressure was examined using transhepatic catheter insertion. RESULTS: IVC-PC was performed in 15 patients (58%). Operating time and procedures did not significantly differ between groups. A direct hemostatic effect on hepatic veins was evaluated in 60% and 70% of patients in groups 1 and 3, respectively. Group 1 showed significantly more unstable vital status and vasopressor use (p < 0.01). Blood or fluid transfusion and urinary output were similar between groups. Group 2 had a significantly lower baseline central venous pressure (CVP), while group 3 showed a significant increase in CVP in TP. CVP under IVC-PC seemed lower than under TP; however, not significantly. Hepatic venous pressure did not significantly differ between groups. Systolic arterial blood pressure significantly decreased via IVC-PC in group 1 and to a similar extent in group 3. Heart rate significantly increased during IVC-PC (p < 0.05). CONCLUSION: IVC-PC combined with the TP may be an alternative procedure to control intrahepatic venous bleeding during anatomical hepatectomy exposing hepatic venous trunks.


Asunto(s)
Anestésicos , Vena Cava Inferior , Humanos , Vena Cava Inferior/cirugía , Hepatectomía/métodos , Constricción , Pérdida de Sangre Quirúrgica/prevención & control
14.
Am J Emerg Med ; 74: 146-151, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37837823

RESUMEN

PURPOSE: This study's objective was to investigate the association between exposure to different intensities of central venous pressure (CVP) over time in patients with septic shock with 28-day mortality and acute kidney injury (AKI). MATERIALS AND METHODS: We obtained data from the AmsterdamUMCdb, which includes data on patients ≥18 years old with septic shock undergoing CVP monitoring. The primary outcome was mortality by day 28. Piecewise exponential additive mixed models were used to estimate the strength of the association over time. RESULTS: 9668 patients were included in the study. They exhibited 8.2% overall mortality at 28 days and 41.1% AKI incidence. Daily time-weighted average CVP was strongly associated with increased mortality at 28 days, primarily within 24 h of ICU admission. The mortality rate of patients was lowest when the CVP was 6-12 cmH2O. When the time of high CVP (TWA-CVP >12 cmH2O) exposure within the first 24 h was >5 h, the risk of death increased by 2.69-fold. Additionally, patients exposed to high CVP had a significantly increased risk of developing AKI. CONCLUSIONS: The optimal CVP range for patients with septic shock within 24 h of ICU admission is 6-12 cmH2O. Mortality increased when patients were exposed to high CVP for >5 h.


Asunto(s)
Lesión Renal Aguda , Choque Séptico , Humanos , Adolescente , Presión Venosa Central , Estudios Retrospectivos , Lesión Renal Aguda/etiología , Hospitalización
15.
BMC Anesthesiol ; 23(1): 249, 2023 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-37481588

RESUMEN

BACKGROUND: In patients undergoing high-risk surgery, it is recommended to titrate fluid administration using stroke volume or a dynamic variable of fluid responsiveness (FR). However, this strategy usually requires the use of a hemodynamic monitor and/or an arterial catheter. Recently, it has been shown that variations of central venous pressure (ΔCVP) during an alveolar recruitment maneuver (ARM) can predict FR and that there is a correlation between CVP and peripheral venous pressure (PVP). This prospective study tested the hypothesis that variations of PVP (ΔPVP) induced by an ARM could predict FR. METHODS: We studied 60 consecutive patients scheduled for high-risk abdominal surgery, excluding those with preoperative cardiac arrhythmias or right ventricular dysfunction. All patients had a peripheral venous catheter, a central venous catheter and a radial arterial catheter linked to a pulse contour monitoring device. PVP was always measured via an 18-gauge catheter inserted at the antecubital fossa. Then an ARM consisting of a standardized gas insufflation to reach a plateau of 30 cmH2O for 30 s was performed before skin incision. Invasive mean arterial pressure (MAP), pulse pressure, heart rate, CVP, PVP, pulse pressure variation (PPV), and stroke volume index (SVI) were recorded before ARM (T1), at the end of ARM (T2), before volume expansion (T3), and one minute after volume expansion (T4). Receiver-operating curves (ROC) analysis with the corresponding grey zone approach were performed to assess the ability of ∆PVP (index test) to predict FR, defined as an ≥ 10% increase in SVI following the administration of a 4 ml/kg balanced crystalloid solution over 5 min. RESULTS: ∆PVP during ARM predicted FR with an area under the ROC curve of 0.76 (95%CI, 0.63 to 0.86). The optimal threshold determined by the Youden Index was a ∆PVP value of 5 mmHg (95%CI, 4 to 6) with a sensitivity of 66% (95%CI, 47 to 81) and a specificity of 82% (95%CI, 63 to 94). The AUC's for predicting FR were not different between ΔPVP, ΔCVP, and PPV. CONCLUSION: During high-risk abdominal surgery, ∆PVP induced by an ARM can moderately predict FR. Nevertheless, other hemodynamic variables did not perform better.


Asunto(s)
Catéteres de Permanencia , Humanos , Estudios Prospectivos , Presión Venosa , Presión Sanguínea , Presión Venosa Central
16.
BMC Anesthesiol ; 23(1): 8, 2023 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-36609229

RESUMEN

BACKGROUND: Blood pressure measurement is an essential element during intraoperative patient management. However, errors caused by changes in transducer levels can occur during surgery. METHODS: This single center, prospective, observational study enrolled 25 consecutive patients scheduled for elective cardiac surgery with invasive arterial and central venous pressure (CVP) monitoring. Hydrostatic pressures caused by level differences (leveling pressure) between a reference point (on the center of the left biceps brachii muscle) and the transducers (fixed on the right side of the operating table) for arterial and central lines were continuously measured using a leveling transducer. Adjusted pressures were calculated as measured pressure - leveling pressure. Hypotension (mean arterial pressure < 80, <70, and < 60 mmHg), and CVP (< 6, ≥6 and < 15, or ≥ 15 mmHg) and pulmonary artery pressure (PAP, mean > 20 mmHg) levels were determined using unadjusted and adjusted pressures. RESULTS: Twenty-two patients were included in the analysis. Leveling pressure ≥ 3 mmHg and ≥ 5 mmHg observed at 46.0 and 18.7% of pooled data points, respectively. Determinations of hypotension using unadjusted and adjusted pressures showed disagreements ranging from 3.3 to 9.4% depending on the cutoffs. Disagreements in defined levels of CVP and PAP were observed at 23.0 and 17.2% of the data points, respectively. CONCLUSIONS: The errors in pressure measurement due to changes in transducer level were not trivial and caused variable disagreements in the determination of MAP, CVP, and PAP levels. To prevent distortions in intraoperative hemodynamic management, strategies should be sought to minimize or adjust for these errors in clinical practice. TRIAL REGISTRATION: cris.nih.go.kr (KCT0006510).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hipotensión , Humanos , Adulto , Presión Venosa Central/fisiología , Transductores de Presión , Estudios Prospectivos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Hipotensión/diagnóstico
17.
Echocardiography ; 40(11): 1216-1226, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37742087

RESUMEN

BACKGROUND: Evaluation of the venous system has long been underestimated as an important component of the circulatory system. As systemic venous pressure increases, the perfusion pressure to the tissues is compromised. During initial resuscitation in cardiac surgery, excessive fluid administration is associated with increased morbidity and mortality. METHODS: We conducted a cross-sectional study of 60 consecutive adult patients who underwent cardiac surgery and in whom it was possible to obtain the venous excess ultrasound (VExUS) grading system and mean systemic filling pressure (Pmsf) in the postoperative period upon admission, at 24 and 48 h. We then determined the correlation between VExUS grading and Pmsf. RESULTS: On admission, patients with VExUS grading 0 predominated, with a progressive increase in venous congestion and an increase in Pmsf over the course of the first 48 h. There was a strong positive correlation between VExUS grading and the invasive measurement of Pmsf at 24 and 48 h after arrival. The presence of grade 2 or grade 3 venous congestion in the postoperative period poses an increased risk of developing acute kidney injury. CONCLUSION: The VExUS grading system indicates a high degree of systemic venous congestion in the first 48 h of the postoperative period after cardiac surgery and correlates with the Pmsf, which is the best surrogate of stressed circulatory volume.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Sistema Cardiovascular , Hiperemia , Humanos , Estudios Transversales
18.
J Cardiothorac Vasc Anesth ; 37(9): 1793-1800, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37286401

RESUMEN

Invasive pressure monitors are ubiquitous in cardiothoracic and vascular anesthesia. This technology allows beat-to-beat assessment of central venous, pulmonary, and arterial blood pressures during surgery, procedural interventions, and critical care. Education is commonly focused on the procedural aspects and the complications associated with the initial placement of these monitors without instruction on the technical concepts required for obtaining accurate data. Anesthesiologists must understand the fundamental concepts on which measurements are made to effectively use invasive pressure monitors, including pulmonary artery catheters, central venous catheters, intra-arterial catheters, external ventricular drains, and spinal or lumbar drains. This review will address important gaps in knowledge surrounding leveling and zeroing of invasive pressure monitors, emphasizing the impact of varied practice patterns on patient care.


Asunto(s)
Cateterismo Periférico , Catéteres Venosos Centrales , Humanos , Presión Arterial , Catéteres de Permanencia , Cuidados Críticos
19.
J Ultrasound Med ; 42(1): 211-220, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35811405

RESUMEN

OBJECTIVES: The Venous Excess Ultrasound (VExUS) score has been described as a useful tool to estimate the degree of venous congestion in adult patients. The present study aimed to analyze the feasibility and usefulness of the VExUS score to detect and grade central venous pressure (CVP) elevation in critically ill children. METHODS: A cross-sectional pilot study was conducted in a tertiary-care pediatric intensive care unit between November 2020 and June 2021. All children in whom CVP was monitored, were enrolled. At the time of central venous catheter placement, CVP and VExUS score grade were determined, analyzing the inferior vena cava (IVC) diameter and the hepatic (HVD), portal (PVD), and intrarenal (IRVD) venous Doppler waveforms. RESULTS: A total of 33 children were studied (median age 12.2 [interquartile range (IQR) 4.1-100.6] months old; median weight 8.5 [IQR 5.6-35] kg; 20 [60.6%] males). The VExUS score was successfully obtained in 100% of the patients and its severity was strongly associated with the CVP levels (P < .001). Analyzing the VExUS score components separately, IVC dilation (P < .001) and severe HVD (P = .026), mild IRVD (P = .005), and severe IRVD (P = .025) patterns were associated with elevated CVP. After adjustment for confounding factors, IRVD pattern remained the only independent variable associated with elevated CVP. CONCLUSIONS: The VExUS score appears to be a feasible and potentially useful bedside noninvasive monitoring tool for the detection and grading of CVP elevation in critically ill children. Among all its components, IRVD assessment seems most associated with high CVP in this population.


Asunto(s)
Enfermedad Crítica , Vena Cava Inferior , Masculino , Adulto , Humanos , Niño , Lactante , Preescolar , Femenino , Presión Venosa Central , Estudios Transversales , Proyectos Piloto , Estudios de Factibilidad
20.
Paediatr Anaesth ; 33(10): 837-843, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37403751

RESUMEN

BACKGROUND: Intravenous administration of highly concentrated and potent drugs at low flow rates is common practice, particularly in critically ill children. Drug delivery during infusion start-up can be considerably delayed by intrinsic factors of syringe infusion pump assemblies. The impact of central venous pressures on the course of start-up fluid delivery of such microinfusions remains unknown. METHODS: Infusion volumes delivered after activation of the start button in a conventional 50 mL syringe infusion pump assembly equilibrated (representing classical in vitro testing) and not equilibrated (representing real clinical conditions) to central venous pressure levels of 0, 10 and 20 mmHg at a set infusion flow rate of 1 mL/h were measured using a fluidic flow sensor. RESULTS: The experimental setup mimicking real life conditions demonstrated considerable differences in fluid delivery during pump start-up depending on central venous pressure. A central venous pressure of 0 mmHg resulted in massive fluid delivery at infusion start-up, while central venous pressure levels of 10 and 20 mmHg resulted in retrograde flows with related mean (95% CI) zero-drug delivery times of 3.22 (2.98-3.46) min and 4.51 (4.33-4.69) min, respectively (p < .0001). CONCLUSION: Depending on central venous pressure level, connection and starting a new syringe pump can result in significant antegrade or retrograde fluid volumes. In clinical practice, this can lead to hemodynamic instability and hence requires clinical alertness. Further research and methods to improve start-up performance in syringe infusion pump systems are desirable.


Asunto(s)
Bombas de Infusión , Niño , Humanos , Presión Venosa Central , Preparaciones Farmacéuticas , Infusiones Intravenosas
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda