Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 684
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(15): e2201937119, 2022 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-35377784

RESUMEN

The awareness of individuals' biological status is critical for creating interactive and adaptive environments that can actively assist the users to achieve optimal outcomes. Accordingly, specialized human­machine interfaces­equipped with bioperception and interpretation capabilities­are required. To this end, we devised a multimodal cryptographic bio-human­machine interface (CB-HMI), which seamlessly translates the user's touch-based entries into encrypted biochemical, biophysical, and biometric indices. As its central component, the CB-HMI features thin hydrogel-coated chemical sensors and inference algorithms to noninvasively and inconspicuously acquire biochemical indices such as circulating molecules that partition onto the skin (here, ethanol and acetaminophen). Additionally, the CB-HMI hosts physical sensors and associated algorithms to simultaneously acquire the user's heart rate, blood oxygen level, and fingerprint minutiae pattern. Supported by human subject studies, we demonstrated the CB-HMI's capability in terms of acquiring physiologically relevant readouts of target bioindices, as well as user-identifying and biometrically encrypting/decrypting these indices in situ (leveraging the fingerprint feature). By upgrading the common surrounding objects with the CB-HMI, we created interactive solutions for driving safety and medication use. Specifically, we demonstrated a vehicle-activation system and a medication-dispensing system, where the integrated CB-HMI uniquely enabled user bioauthentication (on the basis of the user's biological state and identity) prior to rendering the intended services. Harnessing the levels of bioperception achieved by the CB-HMI and other intelligent HMIs, we can equip our surroundings with a comprehensive and deep awareness of individuals' psychophysiological state and needs.


Asunto(s)
Conducción de Automóvil , Percepción del Tacto , Interfaz Usuario-Computador , Humanos , Tacto
2.
Med Res Rev ; 44(1): 23-65, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37246889

RESUMEN

Cytokines are compounds that belong to a special class of signaling biomolecules that are responsible for several functions in the human body, being involved in cell growth, inflammatory, and neoplastic processes. Thus, they represent valuable biomarkers for diagnosing and drug therapy monitoring certain medical conditions. Because cytokines are secreted in the human body, they can be detected in both conventional samples, such as blood or urine, but also in samples less used in medical practice such as sweat or saliva. As the importance of cytokines was identified, various analytical methods for their determination in biological fluids were reported. The gold standard in cytokine detection is considered the enzyme-linked immunosorbent assay method and the most recent ones have been considered and compared in this study. It is known that the conventional methods are accompanied by a few disadvantages that new methods of analysis, especially electrochemical sensors, are trying to overcome. Electrochemical sensors proved to be suited for the elaboration of integrated, portable, and wearable sensing devices, which could also facilitate cytokines determination in medical practice.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Humanos , Sudor/química , Saliva/química , Técnicas Biosensibles/métodos
3.
Small ; : e2400650, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566534

RESUMEN

Holey graphenic nanomaterials with porosity within the basal plane attract significant interest. It is observed that the perforation of graphene can enhance the specific surface area of the nanosheet, ensuring effective wetting and penetration of electrolytes to the electrode surface, facilitating rapid charge transfer, and boosting the electrocatalytic efficacy of the transducers. This study reports the first example of nitrogen-doped holey reduced graphene oxide with a mesoporous morphology of the graphene basal plane (N-MHG). It is shown that N-MHG can be synthesized through a one-step hydrothermal treatment of GO using NH3 and H2O2. A straightforward procedure for the purification of N-MHG has also been developed. AFM, TEM, and Raman analyses have revealed that N-MHG possesses a highly mesoporous network structure with a pore size ranging from 10 to 50 nm. X-ray photoelectron spectroscopy data have indicated a partial reduction of the graphene oxide sheets during the etching process but also show a 3-5 times higher content of C═O and O-C═O fragments compared to rGO. This could account for the remarkable stability of the N-MHG aqueous suspension. An electrochemical sensor for dopamine analysis is assembled on a glassy carbon electrode with N-MHG/Nafion membrane and characterized by cyclic voltammetry and electrochemical impedance spectroscopy.

4.
Small ; : e2403320, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39113348

RESUMEN

The diagnosis of diabetes mellitus (DM) affecting 537 million adults worldwide relies on invasive and costly enzymatic methods that have limited stability. Electroactive polypyrrole (PPy)-based molecularly imprinted polymer nanoparticles (eMIPs) have been developed that rival the affinity of enzymes whilst being low-cost, highly robust, and facile to produce. By drop-casting eMIPs onto low-cost disposable screen-printed electrodes (SPEs), sensors have been manufactured that can electrochemically detect glucose in a wide dynamic range (1 µm-10 mm) with a limit of detection (LOD) of 26 nm. The eMIPs sensors exhibit no cross reactivity to similar compounds and negligible glucose binding to non-imprinted polymeric nanoparticles (eNIPs). Measurements of serum samples of diabetic patients demonstrate excellent correlation (>0.93) between these eMIPs sensor and the current gold standard Roche blood analyzer test. Finally, the eMIPs sensors are highly durable and reproducible (storage >12 months), showcasing excellent robustness and thermal and chemical stability. Proof-of-application is provided via measuring glucose using these eMIPs sensor in a two-electrode configuration in spiked artificial interstitial fluid (AISF), highlighting its potential for non-invasive wearable monitoring. Due to the versatility of the eMIPs that can be adapted to virtually any target, this platform technology holds high promise for sustainable healthcare applications via providing rapid detection, low-cost, and inherent robustness.

5.
Small ; : e2401148, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38801400

RESUMEN

Electrochemical paper-based microfluidics has attracted much attention due to the promise of transforming point-of-care diagnostics by facilitating quantitative analysis with low-cost and portable analyzers. Such devices harness capillary flow to transport samples and reagents, enabling bioassays to be executed passively. Despite exciting demonstrations of capillary-driven electrochemical tests, conventional methods for fabricating electrodes on paper impede capillary flow, limit fluidic pathways, and constrain accessible device architectures. This account reviews recent developments in paper-based electroanalytical devices and offers perspective by revisiting key milestones in lateral flow tests and paper-based microfluidics engineering. The study highlights the benefits associated with electrochemical sensing and discusses how the detection modality can be leveraged to unlock novel functionalities. Particular focus is given to electrofluidic platforms that embed electrodes into paper for enhanced biosensing applications. Together, these innovations pave the way for diagnostic technologies that offer portability, quantitative analysis, and seamless integration with digital healthcare, all without compromising the simplicity of commercially available rapid diagnostic tests.

6.
Chembiochem ; 25(3): e202300560, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-37966365

RESUMEN

Demand for biocompatible, non-invasive, and continuous real-time monitoring of organs-on-chip has driven the development of a variety of novel sensors. However, highest accuracy and sensitivity can arguably be achieved by integrated biosensing, which enables in situ monitoring of the in vitro microenvironment and dynamic responses of tissues and miniature organs recapitulated in organs-on-chip. This paper reviews integrated electrical, electrochemical, and optical sensing methods within organ-on-chip devices and platforms. By affording precise detection of analytes and biochemical reactions, these methods expand and advance the monitoring capabilities and reproducibility of organ-on-chip technology. The integration of these sensing techniques allows a deeper understanding of organ functions, and paves the way for important applications such as drug testing, disease modeling, and personalized medicine. By consolidating recent advancements and highlighting challenges in the field, this review aims to foster further research and innovation in the integration of biosensing in organs-on-chip.


Asunto(s)
Técnicas Biosensibles , Técnicas Biosensibles/métodos , Reproducibilidad de los Resultados , Dispositivos Laboratorio en un Chip
7.
Chembiochem ; 25(17): e202400294, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-38742670

RESUMEN

This work describes the development and evaluation of a novel electrochemical aptasensor for testosterone detection. The sensor utilizes a specifically designed DNA immobilized on a screen-printed gold electrode (SPGE) modified with a conductive hydrogel and gold nanoparticles (HG/NP) composite. The aptasensor exhibited a dose-dependent response to testosterone (0.05 to 50 ng/mL) with a detection limit of 0.14 ng/mL and a good sensitivity of 0.23 µA ng-1 mL cm-2. The sensor displayed excellent selectivity towards testosterone compared to structurally similar steroid hormones. Importantly, the incorporation of HG/NP not only improved the sensor's conductivity but also acted as an antifouling layer, minimizing signal interference from non-specific biomolecule interactions in complex biological samples like human serum. The results obtained from the aptasensor showed good correlation with a standard ELISA method, demonstrating its effectiveness in real-world scenarios.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Técnicas Electroquímicas , Electrodos , Oro , Hidrogeles , Nanocompuestos , Testosterona , Humanos , Oro/química , Aptámeros de Nucleótidos/química , Testosterona/sangre , Técnicas Electroquímicas/métodos , Nanocompuestos/química , Técnicas Biosensibles/métodos , Hidrogeles/química , Límite de Detección , Nanopartículas del Metal/química , Sistemas de Atención de Punto
8.
Anal Biochem ; 691: 115551, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38702023

RESUMEN

A molecularly imprinted electrochemical sensor was facilely fabricated for the detection of thymol (THY). o-Phenylenediamine (oPD) was used as the functional monomer and electropolymerized on the surface of the glassy carbon electrode (GCE) by using THY as the templates. After the THY templates were removed with 50 % (v/v) ethanol, imprinted cavities complementary to the templates were formed within the poly(o-phenylenediamine) (PoPD) films. The resultant molecularly imprinted PoPD/GCE (MI-PoPD/GCE) was used for the detection of THY, and a wide linear range from 0.5 to 100 µM with a low limit of detection (LOD) of 0.084 µM were obtained under the optimal conditions. The developed MI-PoPD/GCE also displays high selectivity, reproducibility and stability for THY detection. Finally, the content of THY in the real samples was accurately determined by the as-fabricated MI-PoPD/GCE, demonstrating its high practicability and reliability.


Asunto(s)
Técnicas Electroquímicas , Impresión Molecular , Fenilendiaminas , Timol , Fenilendiaminas/química , Timol/análisis , Timol/química , Técnicas Electroquímicas/métodos , Límite de Detección , Electrodos , Polímeros Impresos Molecularmente/química , Carbono/química , Reproducibilidad de los Resultados
9.
Anal Biochem ; 688: 115477, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38296105

RESUMEN

Propyl gallate (PG), a prevalent synthetic phenolic antioxidant found in food products, has generated considerable apprehension owing to its potential adverse impacts on human health. Therefore, as a result of the current inquiry, an innovative electrochemical sensor with improved sensitivity and selectivity for PG detection has been created. Under optimal conditions, the manufactured sensor exhibits the capability to identify PG within a broad range from 0.01 µM to 5 µM and from 5 µM to 1000 µM with a limit of detection (LOD) of 6 nM, demonstrating exceptional levels of reproducibility, repeatability, stability, and selectivity. The sensor demonstrated successful detection of PG in edible oils and mayonnaise, with good recoveries ranging from 98.44 % to 101.37 %.


Asunto(s)
Impresión Molecular , Galato de Propilo , Humanos , Técnicas Electroquímicas , Reproducibilidad de los Resultados , Antioxidantes , Límite de Detección , Electrodos
10.
Chemphyschem ; 25(16): e202400355, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-38749914

RESUMEN

Currently, electrochemical sensors are being developed and widely used in various fields, and new materials are being explored to enhance the precision and selectivity of the sensors. The present investigation involved the fabrication of a Fe/graphene/porphyrin nanocomposite through self-assembly, wherein the individual porphyrin molecules were arranged on the Fe/graphene nanomaterials' surface. The Fe/graphene nanoparticles were synthesized utilizing a green approach, wherein leaf extract was employed as the reducing agent. The resulting materials underwent comprehensive characterization using a range of contemporary techniques, including scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), and Raman spectroscopy. The study's findings revealed that the nanocomposites of Fe/graphene/porphyrin comprised zero-valent iron nanoparticles, exhibiting an average particle size ranging from 15 to 60 nm. These nanoparticles were seen to be evenly dispersed across the graphene sheets. The presence of nanostructure porphyrin nanofibers, measuring 20 nm in diameter, was also shown to exhibit strong integration with the surface of the Fe/graphene nanomaterials. The electrochemical properties of the Fe/graphene/porphyrin nanocomposite were also investigated, demonstrating that the prepared material could be effectively employed as a sensing electrode in the electrochemical sensor for detecting Chloramphenicol (CAP) through CV, EIS, and DPV techniques using a three-electrode electrochemical system. Under optimal conditions, Fe/graphene/porphyrin exhibited a high current response when detecting CAPs. Electrochemical sensors created using Fe/graphene/porphyrin nanocomposite have high stability and repeatability, and they hold promise in developing sensors capable of identifying other antibiotic residues in agriculture.

11.
Anal Bioanal Chem ; 416(1): 21-36, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37837539

RESUMEN

Fibrinogen as a major inflammation marker and blood coagulation factor has a direct impact on the health of humanity. The variations in fibrinogen content lead to risky conditions such as bleeding and cardiovascular diseases. So, accurate methods for monitoring of this glycoprotein are of high importance. The conventional methods, such as the Clauss method, are time consuming and require highly specialized expert analysts. The development of fast, simple, easy to use, and inexpensive methods is highly desired. In this way, biosensors have gained outstanding attention since they offer means for performing analyses at the points-of-care using self-testing devices, which can be applied outside of clinical laboratories or hospital. This review indicates that different electrochemical and optical sensors have been successfully implemented for the detection of fibrinogen under normal levels of fibrinogen in plasma. The biosensors for the detection of fibrinogen have been designed based on the quartz crystal microbalance, field-effect transistor, electrochemical impedance spectroscopy, amperometry, surface plasmon resonance, localized surface plasmon resonance, and colorimetric techniques. Also, this review demonstrates the utility of the application of nanoparticles in different detection techniques.


Asunto(s)
Técnicas Biosensibles , Fibrinógeno , Fibrinógeno/química , Técnicas Biosensibles/métodos , Resonancia por Plasmón de Superficie , Colorimetría
12.
Anal Bioanal Chem ; 416(21): 4717-4726, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38970677

RESUMEN

As biomarkers of cancer, the accurate and sensitive detection of microRNAs is of great significance. Therefore, we proposed a surface-enhanced Raman scattering (SERS)/electrochemical (EC) dual-mode nanosensor for sensitively detecting miRNA-141. The nanosensor uses Au@Ag nanowires as a novel SERS/EC sensing platform, which has the advantages of good biocompatibility, fast response, and high sensitivity. The dual-mode nanosensor can not only effectively overcome the problem of insufficient reliability of single signal, but also realize the amplification and stable output of the detection signal, to ensure the reliability and repeatability of miRNA detection. With this sensing strategy, the target miRNA-141 can be detected over a wide linear range (100 fM to 50 nM) (LOD of 18.4 fM for SERS and 16.0 fM for electrochemical methods). In addition, the process shows good selectivity and can distinguish miRNA-141 from other interfering miRNAs. The actual analysis of human serum samples also proves that our strategy has good reliability, repeatability, and has broad application prospects in the field of analysis and detection.


Asunto(s)
Técnicas Electroquímicas , Oro , Límite de Detección , MicroARNs , Nanocables , Plata , Espectrometría Raman , MicroARNs/análisis , MicroARNs/sangre , Nanocables/química , Oro/química , Espectrometría Raman/métodos , Humanos , Plata/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Técnicas Biosensibles/métodos , Reproducibilidad de los Resultados , Nanopartículas del Metal/química
13.
Anal Bioanal Chem ; 416(21): 4679-4690, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38664267

RESUMEN

Prototyping analytical devices with three-dimensional (3D) printing techniques is becoming common in research laboratories. The attractiveness is associated with printers' price reduction and the possibility of creating customized objects that could form complete analytical systems. Even though 3D printing enables the rapid fabrication of electrochemical sensors, its wider adoption by research laboratories is hindered by the lack of reference material and the high "entry barrier" to the field, manifested by the need to learn how to use 3D design software and operate the printers. This review article provides insights into fused deposition modeling 3D printing, discussing key challenges in producing electrochemical sensors using currently available extrusion tools, which include desktop 3D printers and 3D printing pens. Further, we discuss the electrode processing steps, including designing, printing conditions, and post-treatment steps. Finally, this work shed some light on the current applications of such electrochemical devices that can be a reference material for new research involving 3D printing.

14.
Environ Res ; 247: 118285, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38266896

RESUMEN

Traditional microbial electrochemical sensors encounter challenges due to their inherent complexity. In response to these challenges, the microbial potentiometric sensor (MPS) technology was introduced, featuring a straightforward high-impedance measurement circuit tailored for environmental monitoring. Nonetheless, the practical implementation of conventional MPS is constrained by issues such as the exposure of the reference electrode to the monitored water and the absence of methodologies to stimulate microbial metabolism. In this study, our objective was to enhance MPS performance by imbuing it with unique cathodic catalytic properties, specifically tailored for distinct application scenarios. Notably, the anodic region served as the sensing element, with both the cathodic region and reference electrode physically isolated from the analyzed water sample. In the realm of organic monitoring, the sensor without Pt/C coated in the cathodic region exhibited a faster response time (1 h) and lower detection limits (1 mg L-1 BOD, 1 mM acetic acid). Conversely, when monitoring toxic substances, the sensor with Pt/C showcased a lower detection limit (0.004% formaldehyde), while the Pt/C-free sensor demonstrated superior reusability. The sensor with Pt/C displayed a heightened anode biofilm thickness and coverage, predominantly composed of Rhodococcus. In conclusion, this study introduces simple, cost-effective, and tailorable biosensors holding substantial promise for water quality monitoring.


Asunto(s)
Técnicas Biosensibles , Monitoreo del Ambiente , Electrodos , Monitoreo del Ambiente/métodos , Técnicas Biosensibles/métodos , Calidad del Agua
15.
Electrochim Acta ; 4942024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38881690

RESUMEN

Laser-induced graphene (LIG) electrodes have become popular for electrochemical sensor fabrication due to their simplicity for batch production without the use of reagents. The high surface area and favorable electrocatalytic properties also enable the design of small electrochemical devices while retaining the desired electrochemical performance. In this work, we systematically investigated the effect of LIG working electrode size, from 0.8 mm to 4.0 mm diameter, on their electrochemical properties, since it has been widely assumed that the electrochemistry of LIG electrodes is independent of size above the microelectrode size regime. The background and faradaic current from cyclic voltammetry (CV) of an outer-sphere redox probe [Ru(NH3)6]3+ showed that smaller LIG electrodes had a higher electrode roughness factor and electroactive surface ratio than those of the larger electrodes. Moreover, CV of the surface-sensitive redox probes [Fe(CN)6]3- and dopamine revealed that smaller electrodes exhibited better electrocatalytic properties, with enhanced electron transfer kinetics. Scanning electron microscopy, Raman spectroscopy, and X-ray photoelectron spectroscopy showed that the physical and chemical surface structure were different at the electrode center versus the edges, so the electrochemical properties of the smaller electrodes were improved by having rougher surface and more density of the graphitic edge planes, and more oxide-containing groups, leading to better electrochemistry. The difference could be explained by the different photothermal reaction time from the laser scribing process that causes different stable carbon morphology to form on the polymer surface. Our results give a new insight on relationships between surface structure and electrochemistry of LIG electrodes and are useful for designing miniaturized electrochemical devices.

16.
Ecotoxicol Environ Saf ; 282: 116701, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39018731

RESUMEN

Herein, we reported the dual functions of molybdenum disulfide/sulfur-doped graphitic carbon nitride (MoS2/SGCN) composite as a sensing material for electrochemical detection of 4-NP and a catalyst for 4-NP degradation. The MoS2 nanosheet, sulfur-doped graphitic carbon nitride (SGCN) and MoS2/SGCN were characterized using field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD) spectroscopy and X-ray photoelectron spectroscopy (XPS). Electrochemical characterization of these materials with electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) in 1 mM K4[Fe(CN)6]3-/4- show that the composite has the lowest charge transfer resistance and the best electrocatalytic activity. The limit of detection (LOD) and the linear range of 4-nitrophenol at MoS2/SGCN modified glassy carbon electrode (MoS2/SGCN/GCE) were computed as 12.8 nM and 0.1 - 2.6 µM, respectively. Also, the percentage recoveries of 4-NP in spiked tap water samples ranged from 97.8 - 99.1 %. The electroanalysis of 4-NP in the presence of notable interferons shows that the proposed electrochemical sensor features outstanding selectivity toward 4-NP. Additionally, the results of the catalytic degradation of 4-NP at MoS2/SGCN show that the nanocatalyst catalyzed the transformation of 4-NP to 4-aminophenol (4-AP) with a first-order rate constant (k) estimated to be 4.2 ×10-2 s-1. The results of this study confirm that the MoS2/SGCN nanocatalyst is a useful implement for electroanalytical monitoring and catalytic degradation of the hazardous 4-NP in water samples.


Asunto(s)
Disulfuros , Técnicas Electroquímicas , Grafito , Límite de Detección , Molibdeno , Nitrofenoles , Contaminantes Químicos del Agua , Molibdeno/química , Molibdeno/análisis , Nitrofenoles/análisis , Nitrofenoles/química , Técnicas Electroquímicas/métodos , Disulfuros/química , Catálisis , Contaminantes Químicos del Agua/análisis , Grafito/química , Compuestos de Nitrógeno/química , Compuestos de Nitrógeno/análisis , Electrodos
17.
Mikrochim Acta ; 191(8): 463, 2024 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-38995455

RESUMEN

The intensifying global opioid crisis, majorly attributed to fentanyl (FT) and its analogs, has necessitated the development of rapid and ultrasensitive remote/on-site FT sensing modalities. However, current approaches for tracking FT exposure through wastewater-based epidemiology (WBE) are unadaptable, time-consuming, and require trained professionals. Toward developing an extended in situ wastewater opioid monitoring system, we have developed a screen-printed electrochemical FT sensor and integrated it with a customized submersible remote sensing probe. The sensor composition and design have been optimized to address the challenges for extended in situ FT monitoring. Specifically, ZIF-8 metal-organic framework (MOF)-derived mesoporous carbon (MPC) nanoparticles (NPs) are incorporated in the screen-printed carbon electrode (SPCE) transducer to improve FT accumulation and its electrocatalytic oxidation. A rapid (10 s) and sensitive square wave voltammetric (SWV) FT detection down to 9.9 µgL-1 is thus achieved in aqueous buffer solution. A protective mixed-matrix membrane (MMM) has been optimized as the anti-fouling sensor coating to mitigate electrode passivation by FT oxidation products and enable long-term, intermittent FT monitoring. The unique MMM, comprising an insulating polyvinyl chloride (PVC) matrix and carboxyl-functionalized multi-walled carbon nanotubes (CNT-COOH) as semiconductive fillers, yielded highly stable FT sensor operation (> 95% normalized response) up to 10 h in domestic wastewater, and up to 4 h in untreated river water. This sensing platform enables wireless data acquisition on a smartphone via Bluetooth. Such effective remote operation of submersible opioid sensing probes could enable stricter surveillance of community water systems toward timely alerts, countermeasures, and legal enforcement.


Asunto(s)
Analgésicos Opioides , Técnicas Electroquímicas , Fentanilo , Estructuras Metalorgánicas , Contaminantes Químicos del Agua , Contaminantes Químicos del Agua/análisis , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Fentanilo/análisis , Fentanilo/sangre , Analgésicos Opioides/análisis , Estructuras Metalorgánicas/química , Electrodos , Aguas Residuales/análisis , Monitoreo del Ambiente/métodos , Límite de Detección , Carbono/química , Nanopartículas/química , Tecnología de Sensores Remotos/métodos
18.
Mikrochim Acta ; 191(8): 481, 2024 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046557

RESUMEN

It is crucial to accurately and rapidly monitor the levodopa (LD) concentration for accurate classification and treatment of dyskinesia in Parkinson's disease. In this paper, 3D graphene foam (GF) with a highly conductive network is obtained by chemical vapor deposition. 3D GF serves as the substrate for hydrothermal in situ growth of tapered cross-linked ZnO nanowire bundle arrays (ZnO NWBAs), enabling the development of a highly sensitive detection platform for LD. The formation mechanism of a tapered cross-linked ZnO nanowire bundle arrays on 3D GF is put forward. The integration of 3D GF and ZnO NWBAs can accelerate the electron transfer rate and increase the contact area with biomolecules, resulting in high electrochemical properties. The electrode composed of ZnO NWBAs on 3D GF exhibits significant sensitivity (1.66 µA·µM-1·cm-2) for LD detection in the concentration range 0-60 µM. The electrode is able to rapidly and specifically determine LD in mixed AA or UA solution. The selectivity mechanism of the electrode is also explained by the bandgap model. Furthermore, the successful detection of LD in serum demonstrates the practicality of the electrode and its great potential for clinical application.


Asunto(s)
Técnicas Electroquímicas , Grafito , Levodopa , Límite de Detección , Nanocables , Óxido de Zinc , Grafito/química , Óxido de Zinc/química , Nanocables/química , Levodopa/sangre , Levodopa/análisis , Levodopa/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Electrodos , Humanos
19.
Mikrochim Acta ; 191(3): 146, 2024 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-38372811

RESUMEN

Salmonella contamination is a major global health challenge, causing significant foodborne illness. However, current detection methods face limitations in sensitivity and time, which mostly rely on the culture-based detection techniques. Hence, there is an immediate and critical need to enhance early detection, reduce the incidence and impact of Salmonella contamination resulting in outbreaks. In this work, we demonstrate a portable non-faradaic, electrochemical sensing platform capable of detecting Salmonella in potable water with an assay turnaround time of ~ 9 min. We evaluated the effectiveness of this sensing platform by studying two sensor configurations: one utilizing pure gold (Au) and the other incorporating a semiconductor namely a zinc oxide thin film coated on the surface of the gold (Au/ZnO). The inclusion of zinc oxide was intended to enhance the sensing capabilities of the system. Through comprehensive experimentation and analysis, the LoD (limit of detection) values for the Au sensor and Au/ZnO sensor were 0.9 and 0.6 CFU/mL, respectively. In addition to sensitivity, we examined the sensing platform's precision and reproducibility. Both the Au sensor and Au/ZnO sensor exhibited remarkable consistency, with inter-study percentage coefficient of variation (%CV) and intra-study %CV consistently below 10%. The proposed sensing platform exhibits high sensitivity in detecting low concentrations of Salmonella in potable water. Its successful development demonstrates its potential as a rapid and on-site detection tool, offering portability and ease of use. This research opens new avenues for electrochemical-based sensors in food safety and public health, mitigating Salmonella outbreaks and improving water quality monitoring.


Asunto(s)
Agua Potable , Óxido de Zinc , Reproducibilidad de los Resultados , Oro , Salmonella
20.
Mikrochim Acta ; 191(8): 500, 2024 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-39088046

RESUMEN

Detecting lipopolysaccharide (LPS) using electrochemical methods is significant because of their exceptional sensitivity, simplicity, and user-friendliness. Two-dimensional metal-organic framework (2D-MOF) that merges the benefits of MOF and 2D nanostructure has exhibited remarkable performance in constructing electrochemical sensors, notably surpassing traditional 3D-MOFs. In this study, Cu[tetrakis(4-carboxylphenyl)porphyrin] (Cu-TCPP) and Cu(tetrahydroxyquinone) (Cu-THQ) 2D nanosheets were synthesized and applied on a glassy carbon electrode (GCE). The 2D-MOF nanosheets, which serve as supporting layers, exhibit improved electron transfer and electronic conductivity characteristics. Subsequently, the modified electrode was subjected to electrodeposition with Au nanostructures, resulting in the formation of Au/Cu-TCPP/GCE and Au/Cu-THQ/GCE. Notably, the Au/Cu-THQ/GCE demonstrated superior electrochemical activity because of the 2D morphology, redox ligand, dense Cu sites, and improved deposition of flower-like Au nanostructure based on Cu-THQ. The electron transfer specific surface area was increased by the improved deposition of Au nanostructures, which facilitates enriched binding of LPS aptamer and significantly improved the detection performance of Apt/Au/Cu-THQ/GCE electrochemical aptasensor. The limit of detection for LPS reached 0.15 fg/mL with a linear range of 1 fg/mL - 100 pg/mL. The proposed aptasensor demonstrated the ability to detect LPS in serum samples with satisfactory accuracy, indicating significant potential for clinical diagnosis.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Cobre , Técnicas Electroquímicas , Oro , Límite de Detección , Lipopolisacáridos , Estructuras Metalorgánicas , Estructuras Metalorgánicas/química , Oro/química , Cobre/química , Técnicas Electroquímicas/métodos , Lipopolisacáridos/análisis , Lipopolisacáridos/sangre , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Electrodos , Nanoestructuras/química , Porfirinas/química , Humanos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda