Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 868
Filtrar
Más filtros

Tipo del documento
Publication year range
1.
Postgrad Med J ; 100(1185): 496-503, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38366645

RESUMEN

BACKGROUND: Multiple displaced rib fractures often result in a poor prognosis. Open reduction and internal fixation has been shown to provide benefits for patients with displaced rib fractures and flail chest. Nevertheless, for patients who are unwilling or unsuitable for surgery, the therapeutic options are limited. We developed a novel plastic vacuum device for rib fractures external stabilization. This study aims to compare the therapeutic efficacy of this device against a traditional chest strap in polytrauma patients with multiple rib fractures. METHODS: A retrospective investigation was conducted on polytrauma patients with multiple rib fractures admitted to our trauma center between March 2020 and March 2023. Patients were categorized into two groups: vacuum external fixation and chest strap. Comparative analysis was conducted on baseline parameters, injury characteristics, and clinical outcomes between the two groups. RESULTS: In this study, 54 patients were included, with 28 receiving chest strap and 26 undergoing vacuum external fixation. Results showed that, at 3 days and 7 days postintervention, the vacuum external fixation group had significantly lower visual analog scale scores during deep breathing and coughing (P < .05). Vacuum external fixation also reduced pleural drainage duration and volume, as well as lowered the risk of pneumonia and other complications (P < .05). Furthermore, the vacuum external fixation group demonstrated notable improvements in vital capacity, tidal volume, blood-gas test results, and a shorter hospital length of stay. CONCLUSIONS: According to the study findings, vacuum external fixation appears to offer benefits to patients with multiple rib fractures, potentially reducing the risk of complications and improving overall clinical outcomes.


Asunto(s)
Fijación de Fractura , Traumatismo Múltiple , Fracturas de las Costillas , Humanos , Fracturas de las Costillas/cirugía , Fracturas de las Costillas/terapia , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Traumatismo Múltiple/cirugía , Traumatismo Múltiple/terapia , Fijación de Fractura/métodos , Fijación de Fractura/instrumentación , Vacio , Adulto , Fijadores Externos , Anciano , Resultado del Tratamiento , Tiempo de Internación , Fracturas Múltiples/cirugía
2.
BMC Musculoskelet Disord ; 25(1): 483, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38898453

RESUMEN

INTRODUCTION: The Ilizarov bone transport technique is widely recognised as an effective method for treating large segment bone defects in clinical practice. However, axial deviation is a common complication in the treatment of tibial large segment bone defects, which can have a serious impact on the clinical efficacy of bone transport. Our study aims to construct and validate a nomogram for predicting axial deviation of tibial bone transport. METHOD: This study retrospectively collected data from 363 patients who underwent the tibial Ilizarov technique for bone transport. Univariate and multivariate logistic regression analyses were performed to determine the independent risk factors for axial deviation, which were later used to construct a nomogram. The nomogram was evaluated using the decision curve analysis (DCA), the calibration curve, and the area under the receiver operating characteristic curve (AUC). RESULTS: Of the 363 patients who underwent Ilizarov tibial bone transport, 31.7% (115/363) experienced axial deviation. Multivariate logistic regression analysis showed that gender, height, defect site, and external fixation index were important risk factors for axial deviation. The AUC value of the nomogram model was 0.705. The calibration curve and the decision curve analysis showed a good consistency between the actual axial deviation and the predicted probability. CONCLUSION: The model assigns a quantitative risk score to each variable, which can be used to predict the risk of axial deviation during tibial bone transport.


Asunto(s)
Técnica de Ilizarov , Nomogramas , Tibia , Humanos , Femenino , Masculino , Estudios Retrospectivos , Adulto , Tibia/cirugía , Persona de Mediana Edad , Factores de Riesgo , Adulto Joven , Adolescente , Anciano , Complicaciones Posoperatorias/etiología
3.
BMC Musculoskelet Disord ; 25(1): 104, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38297262

RESUMEN

BACKGROUND: The shortcomings of plaster in water resistance, air permeability, skin comfort, fixed stability and weight of wearing are still to be solved. 3D printed cast can overcome the above shortcomings. At present, there is a relative lack of data on the clinical application of 3D printed cast, probably due to its complexity, relatively long operating time, and high price. We aimed to compare and evaluate the short-term effectiveness, safety and advantages of 3D printed wrist cast versus polymer orthosis in the treatment of Colles fracture. METHODS: Forty patients with Colles fracture in our hospital from June to December 2022 were selected and divided into an observation group (20 patients, treated with instant 3D printed cast) and a control group (20 cases, treated with polymer orthosis). Both groups treated with manual reduction and external fixation. The visual analogue scale (VAS), immobilization effectiveness and satisfaction scores, Disability of the Arm, Shoulder and Hand (DASH) score, complications and imaging data were collected and compared before immobilization and at 2, 6 and 12 weeks after the fracture. RESULTS: VAS at 2 weeks after the fracture was significantly lower in the observation group than in the control group ( P < 0.05). The immobilization effectiveness and satisfaction scores at 6 weeks after the fracture were significantly higher in the observation group than in the control group (all P < 0.05). The DASH scores at 2 and 6 weeks after the fracture were significantly lower in the observation group than in the control group (all P < 0.05). There wasn't rupture of the printed cast or orthosis in both groups. There were 2 cases of skin irritation in the control group, and no skin irritation occurred in the observation group. The palmar tilt angle and ulnar inclination angle at 2 weeks and 12 weeks after the fracture were significantly higher in the observation group than in the control group (all P < 0.05). CONCLUSIONS: Both instant 3D printed cast and polymer orthosis are effective in the treatment of Colles fracture. But instant 3D printed cast is better than polymer orthosis in areas of good clinical and imaging performance, and high patient satisfaction and comfort.


Asunto(s)
Fractura de Colles , Fracturas del Radio , Humanos , Fractura de Colles/cirugía , Aparatos Ortopédicos , Tirantes , Fijación de Fractura/métodos , Impresión Tridimensional , Resultado del Tratamiento , Fracturas del Radio/cirugía , Moldes Quirúrgicos
4.
BMC Musculoskelet Disord ; 25(1): 622, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103800

RESUMEN

OBJECTIVE: The management of length-unstable femoral shaft fractures(LUFSFs) in pediatric patients is still controversial. This study aims to explore the clinical efficacy of ultrasound-guided closed reduction combined with external fixation for treating LUFSFs in children. METHODS: We conducted a retrospective analysis of clinical data from 19 pediatric patients with LUFSFs who underwent ultrasound-guided closed reduction and external fixation between January 2018 and January 2023. Ultrasound was employed not only to facilitate closed reduction of the fracture but also to guide real-time insertion of Schanz pins and monitor pin length as it traversed the opposite cortex. Surgical time, intraoperative fluoroscopy count, hospital stay length, fracture fixation duration, complication incidence, fracture reduction quality at the final follow-up were recorded. RESULTS: The patients' average age was 7.5 years( range: 5 to 11 years). The mean surgical duration was 70.4 min (range: 48-105 min), and the average intraoperative fluoroscopy count was 6.5 (range: 2-16). Fracture fixation lasted an average of 10.9 weeks (range: 7-20 weeks). All patients were followed up for more than one year. 6 cases of superficial pin tract infection occurred, which resolved with oral antibiotics and enhanced needle tract care. No deep infections were observed. Temporary stiffness of the knee joint was observed in 2 patients. According to Flynn's efficacy evaluation system, fracture reduction quality at the final follow-up was rated as excellent in 11 cases and satisfactory in 8 cases, yielding a combined success rate of 100% (19/19). CONCLUSIONS: The technique of ultrasound-guided closed reduction combined with external fixation offers favorable outcomes for children aged 5 to 11 years with LUFSFs, reducing reliance on fluoroscopic guidance.


Asunto(s)
Fracturas del Fémur , Fijación de Fractura , Ultrasonografía Intervencional , Humanos , Niño , Estudios Retrospectivos , Femenino , Preescolar , Fracturas del Fémur/cirugía , Fracturas del Fémur/diagnóstico por imagen , Masculino , Ultrasonografía Intervencional/métodos , Fijación de Fractura/métodos , Reducción Cerrada/métodos , Resultado del Tratamiento , Clavos Ortopédicos , Tempo Operativo
5.
J Arthroplasty ; 39(9S1): S124-S130, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38631515

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) for dislocated hips (Crowe IV dysplasia) presents unique challenges. Conventional approaches involve subtrochanteric osteotomies, but are complex with additional fixation and potentially lead to limb length discrepancies, nerve palsies, and other complications. An alternative strategy is a staged approach, where the femoral head (or remnant) is gradually lowered (distraction technique) to align with the true acetabulum over a period of time, followed by a second-stage anatomically acetabular-positioned THA. External fixation distraction and telescoping internal lengthening devices have been utilized to achieve preoperative alignment. We evaluated these techniques, including the types, time, and amount of distraction needed, as well as outcomes and complication rates. METHODS: In this retrospective case series, 14 patients (9 women, 5 men), who had a mean age of 32 years (range, 16 to 67), underwent staged surgical interventions using hip distraction using external fixators or internal lengthening devices for hip dysplasia and other pathologies (Perthes disease, osteonecrosis) in preparation for a second-stage anatomically placed THA. The mean follow-up duration for external-fixation patients was 10 years (range, 6.5 to 13.4). RESULTS: Staged treatment involved external fixators (n = 8) or internal lengthening devices (n = 6) with a device placement mean of 48 days (range, 42 to 71). The amount of distraction ranged from 6 to 12 cm. There were 2 patients who required uncomplicated revision of the internal lengthening devices, and another patient had a temporary peroneal nerve palsy. There was 1 patient who underwent an acetabular revision at 7 years. CONCLUSIONS: We focused on a challenging patient cohort that emphasizes the efficacy of staged interventions in managing Crowe Type IV dysplasia and similar cases. Favorable outcomes were found with the immediate transition to THA after device removal that effectively addressed soft-tissue contractures and femoral migration. Despite the need for further validation via larger, prospective studies, this innovative approach may pave the way toward optimizing this strategy for these difficult hip pathologies.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteogénesis por Distracción , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Adolescente , Anciano , Osteogénesis por Distracción/instrumentación , Osteogénesis por Distracción/métodos , Adulto Joven , Resultado del Tratamiento , Displasia del Desarrollo de la Cadera/cirugía , Fijadores Externos , Acetábulo/cirugía , Articulación de la Cadera/cirugía
6.
J Orthop Sci ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39054230

RESUMEN

BACKGROUND: This study aimed to introduce a potential alternative percutaneous treatment for AO types C1, C2, and C3 distal radius fractures using dual-external fixator (a no-bridging cemented-pin frame and a conventional wrist-bridging external fixator). MATERIALS AND METHODS: From January 2018 to January 2021, 52 patients (52 distal radius fractures) were treated with dual-external fixator. For comparison, 61 patients (61 distal radius fractures) were treated with a plate and screw system. Wrist function was assessed using the Mayo Wrist Score. Patient satisfaction was assessed using the Short Assessment of Patient Satisfaction. A P < 0.05 was considered statistically significant. RESULTS: Fracture healing was achieved in all patients. At the final follow-up of 29 months (range, 24-34 months) vs 36 months (range, 26-39 months) (P > 0.05), the patients treated with dual-external fixator and a plate and screw system achieved mean ulnar deviations of 31° vs 29° (P < 0.05), mean Mayo Wrist Scores of 91.12 ± 5.98 vs 88.12 ± 7.54 (P < 0.05), and mean patient satisfaction scores of 23.42 ± 2.47 vs 23.04 ± 2.32 (P > 0.05). CONCLUSIONS: AO types C1, C2, and C3 distal radius fractures can be treated successfully using dual-external fixator. The technique is a potential alternative in addition to the conventional treatments. LEVEL OF EVIDENCE: Level IIa.

7.
Chin J Traumatol ; 27(5): 254-262, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39079771

RESUMEN

PURPOSE: Shaping and assembling contemporary external fixators rapidly for the severe mandibular fractures remains a challenge, especially in emergency circumstance. We designed a novel external fixator that incorporates universal joints to provide the stabilization for mandibular comminuted fractures. This study aims to confirm the efficacy of this novel external fixator through biomechanical tests in vitro and animal experiments. METHODS: In vitro biomechanical tests were conducted using 6 fresh canine with mandibular defect to simulate critical comminuted fractures. Three mandibles were stabilized by the novel external fixator and other mandibles were fixed by 2.5 mm reconstruction plates. All fixed mandibles were subjected to loads of 350 N on the anterior regions of teeth and 550 N on the first molar of the unaffected side. The stability was evaluated based on the maximum displacement and the slope of the load-displacement curve. In animal experiments, 9 beagles with comminuted mandibular fractures were divided into 3 groups, which were treated with the novel external fixation, reconstruction plate, and dental arch bar, respectively. The general observation, the changes in animals' weight, and the surgical duration were recorded and compared among 3 groups. The CT scans were performed at various intervals of 0 day (immediately after the surgery), 3 days, 7 days, 14 days, 21 days, and 28 days to analyze the displacement of feature points on the canine mandible and situation of fracture healing at 28 days. The statistical significance was assessed by the two-way analysis of variance test followed by the Bonferroni test, enabling multiple comparisons for all tests using GraphPad Prism10.1.0 (GraphPad Inc, USA). RESULTS: The outcomes of the biomechanical tests indicated that no statistically significant differences were found in terms of the maximum displacement (p = 0.496, 0.079) and the slope of load displacement curves (p = 0.374, 0.349) under 2 load modes between the external and internal fixation groups. The animal experiment data showed that there were minor displacements of feature points between the external and internal fixation groups without statistic difference, while the arch bar group demonstrated inferior stability. The CT analysis revealed that the best fracture healing happened in the internal fixation group, followed by the external fixation and arch baring at 28 days after fixation. The external fixation group had the shortest fixation duration (25.67 ± 3.79) min compared to internal fixation ((70.67 ± 4.51) min, p < 0.001) and arch baring ((42.00 ± 3.00) min, p = 0.046). CONCLUSION: The conclusion of this study highlighted the efficacy and reliability of this novel external fixator in managing mandibular fractures rapidly, offering a viable option for the initial stabilization of comminuted mandibular fractures in the setting of emergency rescue.


Asunto(s)
Fijadores Externos , Fijación de Fractura , Fracturas Conminutas , Fracturas Mandibulares , Animales , Fracturas Mandibulares/cirugía , Fracturas Mandibulares/diagnóstico por imagen , Fracturas Conminutas/cirugía , Perros , Fijación de Fractura/métodos , Fenómenos Biomecánicos
8.
Int Wound J ; 21(4): e14548, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38151911

RESUMEN

The clinical management of traumatic chest incisions accompanied by rib fractures presents the formidable challenge. The study was carried out to compare the outcomes of auscultatory triangle internal fixation (ATIF) and external fixation (EF) in such injuries. From June 2019 to June 2022, 105 patients with multiple rib fractures participated in the cohort study in which they were divided into two groups: 53 patients underwent ATIF and 52 patients underwent EF. The incidence of surgical site infection, wound healing time, incidence of wound dehiscence, number of dressing changes, pain as measured by the visual analogue scale (VAS), duration of hospitalization, period of return to work, pulmonary complications and functionality of the upper limbs as assessed by the Disability of Arm, Shoulder, and Hand (DASH) questionnaire were among the parameters evaluated. In comparison with EF, ATIF demonstrated the decreased incidence of wound dehiscence (1.9% vs. 9.6%) (p < 0.05), surgical site infection (3.8 vs. 11.5) and wound healing time (12.3 ± 2.1 vs. 18.5 ± 3.7 days) (p < 0.05). Furthermore, during their ATIF treatment, patients required fewer changes of dressing (3.5 ± 0.8 vs. 5.7 ± 1.2) and demonstrated enhanced pain management, reduced hospital stays and expedited return to work (p < 0.05). ATIF group demonstrated enhancements in both upper limb functionality and post-operative pulmonary function (p < 0.05). The utilization of ATIF as opposed to EF for the treatment of traumatic chest wounds accompanied by rib fractures yields superior outcomes in terms of wound healing, infection reduction and restoration of pulmonary and upper limb functionality.


Asunto(s)
Fracturas de las Costillas , Humanos , Fracturas de las Costillas/complicaciones , Fracturas de las Costillas/cirugía , Infección de la Herida Quirúrgica/terapia , Estudios de Cohortes , Fijación Interna de Fracturas/efectos adversos , Cicatrización de Heridas , Estudios Retrospectivos
9.
Medicina (Kaunas) ; 60(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39336460

RESUMEN

Background: The most problematic complication of external fixation is infection at the pin insertion site. Technology that improves the adhesion of the external fixation pin to the skin, subcutaneous tissue, and bone may prevent infection at the pin site. The purpose of this study is to formulate a calcium phosphate-fibroblast growth factor (Cp-FGF) coating on a stainless-steel external fixation pin and to verify its effectiveness in reducing infection at the pin site and its possible influence on bone fixation in animal experiments. Methods: We compared stainless-steel screws without coating (SS group; n = 32), those with a calcium phosphate coating (Cp group; n = 30), those with a Cp-FGF coating (FGF group; n = 32), and those with a Cp-FGF coating having enhanced biological activity (FGF+ group; n = 32) in male Japanese white domesticated rabbits. Screws were inserted percutaneously into the bilateral proximal tibial diaphysis of the rabbits and implanted for 4 weeks. Screws and periscrew tissue were observed postoperatively for qualitatively assessing infection. Results: Infection assessment by gross findings after 4 weeks (at screw removal) showed no significant differences between the groups. Histopathological evaluation of soft tissue infection and bone tissue infection showed no significant differences between the groups for either soft tissue or bone tissue. Since neither the FGF+ group nor the FGF group showed anti-infective effects, the biological activity of FGF is not the only determining factor. We compared SEM, XRD, coating detaching test, sustained release test, and bioassay to examine physicochemical properties among the coatings but found no sufficient differences. Conclusions: It is suggested that improving the tissue adhesion to and/or biocompatibility of pins is also important to improve the in vivo performance of Cp-FGF-coated external fixation pins.


Asunto(s)
Antiinfecciosos , Factores de Crecimiento de Fibroblastos , Acero Inoxidable , Animales , Masculino , Conejos , Antiinfecciosos/farmacología , Antiinfecciosos/uso terapéutico , Antiinfecciosos/administración & dosificación , Clavos Ortopédicos , Fosfatos de Calcio/uso terapéutico , Materiales Biocompatibles Revestidos , Factores de Crecimiento de Fibroblastos/uso terapéutico , Factores de Crecimiento de Fibroblastos/administración & dosificación , Factores de Crecimiento de Fibroblastos/farmacología
10.
Foot Ankle Surg ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39245585

RESUMEN

INTRODUCTION: Foot and ankle pathology can often require complex surgical reconstruction. Until recently, circular external fixators such as the Ilizarov frame have proven to be useful, yet they fall short when progressive, precise corrections are required. Computer-assisted hexapod external fixators seek to address many of the shortfalls of traditional circular fixators. However, evidence for their use is scarce. The objective of this work was to evaluate the functional and quality of life outcomes and post-operative complications of patients treated with computer-assisted hexapod external fixation. METHODS: A retrospective, observational study was conducted. All cases were treated with either a TrueLok hex (TL-HEX) or a Taylor Spatial Frame (TSF) fixator. Primary outcomes were post-operative improvement in 12-Item Short Form Survey (SF12) and American Orthopaedic Foot and Ankle Score (AOFAS) scores, and complications following Paley's classification. RESULTS: A total of 59 patients with complex foot and ankle conditions using 64 external fixation frames were included. The median sum of both SF12 score domains improved from a preoperative score of 63.6 to 91.3 at last follow-up (p < 0.001). Median AOFAS improved from a preoperative score of 35 to 75.5 at last follow up (p < 0.001). Functional improvement was not affected by the choice of external fixator. Complications occurred in 49 cases (77 %). The most common post-operative complications included pin tract complications in 37 (58 %) cases, joint rigidity in 24 (38 %) and axial deviation in 9 (14 %). CONCLUSIONS: Computer-assisted hexapod external fixation is an effective technique to correct complex foot and ankle deformities and leads to a marked improvement in post-operative functional and quality-of-life outcomes with a high minor complication rate.

11.
Foot Ankle Surg ; 30(3): 239-244, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38123374

RESUMEN

BACKGROUND: The authors developed a simple extensible external fixator, which has the advantages of easy application and inexpensiveness. The present study aimed to make a comparison between this external fixator and calcaneal traction in preoperative temporary fixation for malaligned ankle fractures and pilon fractures. METHODS: From May 2020 to February 2022, patients with malaligned ankle fractures or Rüedi-Allgöwer type 2 or 3 pilon fractures with obvious soft tissue swelling were retrospectively reviewed and divided into the calcaneal traction group and the external fixation group. The two groups of patients were matched 1:1 before making comparisons. RESULTS: A total of 38 patients were included. Higher General Comfort Questionnaire score and lower visual analog scale score were noticed in the external fixation group during hospitalization (p < 0.05), while the operation latency time, total cost, patient satisfaction, and functional outcomes one year after surgery were not significantly different between the two groups. No wound complications were observed. CONCLUSION: Preoperative temporary fixation for fractures around the ankle using this simple extensible external fixator significantly improves patient comfort when compared to calcaneal traction. LEVEL OF EVIDENCE: III, retrospective comparative study.


Asunto(s)
Fracturas de Tobillo , Traumatismos del Tobillo , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Fracturas de Tobillo/cirugía , Tobillo , Comodidad del Paciente , Fijación Interna de Fracturas , Resultado del Tratamiento , Traumatismos del Tobillo/cirugía , Fracturas de la Tibia/cirugía , Fijadores Externos
12.
Eur J Orthop Surg Traumatol ; 34(1): 237-242, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37433971

RESUMEN

PURPOSE: Pilon fractures are often complex injuries involving severe soft tissue injury. Studies have shown pilon fractures may entrap soft tissue structures between fracture fragments. Staged fixation of pilon fractures with spanning external fixation (SEF) is important for soft tissue rest and plays an important role in the management of these injuries. While SEF has been shown to promote soft tissue rest prior to definitive fixation, no studies have shown the effect SEF has on entrapped structures (ES). The purpose of this study was to evaluate how SEF effects ES in pilon fractures. METHODS: A retrospective review of 212 pilon fractures treated at our institution between 2010 and 2022 was performed. Patients with a CT scan pre-SEF and post-SEF met inclusion criteria. CTs were reviewed to characterize ES in pre- and post-SEF imaging. RESULTS: Of the 19 patients with ES identified on CT pre-SEF, seven (36.8%) had full release of ES post-SEF and 12 (63.2%) had no release of ES. The posterior tibial tendon was the most commonly ES and remained entrapped in 62.5% of cases. Only 25% of 43-C3 fractures had release of ES post-SEF, while 100% of 43-C1 and 43-C2 fractures demonstrated complete release of ES post-SEF. CONCLUSION: Entrapped structures in pilon fractures are likely to remain entrapped post-SEF, with only one-third of our cohort demonstrating release. In 43-C3 patterns, if ES are identified on CT pre-SEF, surgeons should consider addressing these either through mini open versus open approaches at the time of SEF as they are likely to remain entrapped post-SEF.


Asunto(s)
Fracturas de Tobillo , Traumatismos del Tobillo , Fracturas de la Tibia , Humanos , Fijación Interna de Fracturas , Fijación de Fractura , Fijadores Externos , Resultado del Tratamiento , Traumatismos del Tobillo/cirugía , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Estudios Retrospectivos
13.
Eur J Orthop Surg Traumatol ; 34(5): 2773-2778, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38771369

RESUMEN

PURPOSE: Determine if anterior internal versus supra-acetabular external fixation of unstable pelvic fractures is associated with care needs or discharge. METHODS: A retrospective cohort study was performed at two tertiary trauma referral centers. Adults with unstable pelvis fractures (AO/OTA 61B/61C) who received operative fixation of the anterior and posterior pelvic ring by two orthopedic trauma surgeons from October 2020 to November 2022 were included. The primary outcome was discharge destination. Secondary outcomes included intensive care unit (ICU) or ventilator days, length of stay, and hospital charges. RESULTS: Eighty-three eligible patients were 38.6% female, with a mean age of 47.2 ± 20.3 years and BMI 28.1 ± 6.4 kg/m2. Fifty-nine patients (71.1%) received anterior pelvis internal fixation and 24 (28.9%) received external fixation. External fixation was associated with weight-bearing restrictions (91.7% versus 49.2%, p = 0.01). No differences in demographic, functional status, insurance type, fracture classification, or injury severity measures were observed by treatment. Internal versus external anterior pelvic fixation was not associated with discharge to home (49.2% versus 29.2%, p = 0.10), median ICU days (3.0 [interquartile range (IQR) 7.8 versus 5.5 [IQR 4.3], p = 0.14, ventilator days (0 [IQR 6.0] versus 0 [IQR 2.8], p = 0.51), length of stay (13.0 [IQR 13.0] versus 17.5 (IQR 20.5), p = 0.38), or total hospital charges (US dollars 180,311 [IQR 219,061.75] versus 243,622 [IQR 187,111], p = 0.14). CONCLUSIONS: Anterior internal versus supra-acetabular external fixation of unstable pelvis fractures was not significantly associated with discharge destination, critical care, hospital length of stay, or hospital charges. This sample may be underpowered to detect differences between groups. LEVEL OF EVIDENCE: Therapeutic Level IV.


Asunto(s)
Cuidados Críticos , Fijación Interna de Fracturas , Fijación de Fractura , Fracturas Óseas , Precios de Hospital , Tiempo de Internación , Alta del Paciente , Huesos Pélvicos , Humanos , Femenino , Tiempo de Internación/estadística & datos numéricos , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Alta del Paciente/estadística & datos numéricos , Huesos Pélvicos/lesiones , Precios de Hospital/estadística & datos numéricos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/economía , Fijación Interna de Fracturas/métodos , Cuidados Críticos/economía , Cuidados Críticos/estadística & datos numéricos , Fijación de Fractura/métodos , Fijación de Fractura/economía , Adulto
14.
Eur J Orthop Surg Traumatol ; 34(1): 161-166, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37386191

RESUMEN

PURPOSE: Fracture blisters, a common soft-tissue complication of pilon fractures, are associated with post-operative wound infections, delays in definitive fixation, and alterations in surgical plan. The purpose of this study was to (1) identify the delay in surgery attributable to the presence fracture blisters and (2) investigate the relationship of fracture blisters to comorbidities and fracture severity. METHODS: Patients with pilon fractures at an urban level 1 Trauma center from 2010 to 2021 were identified. The presence or absence of fracture blisters was noted, along with location. Demographic information, time from injury to external fixator placement, and time to definitive open reduction internal fixation (ORIF) were collected. Pilon fractures were classified according to AO/OTA guidelines using CT imaging and plain radiographs. RESULTS: 314 patients with pilon fractures were available for analysis, eighty (25%) of whom were found to have fracture blisters. Patients with fracture blisters had longer time to surgery compared to those without fracture blisters (14.2 days vs 7.9 days, p < 0.001). A greater proportion of patients with fracture blisters had AO/OTA 43C fracture patterns, compared with those without fracture blisters (71.3% vs 53.8%, p = 0.03). Fractures blisters were less likely to be localized over the posterior ankle (12%, p = 0.007). CONCLUSION: The presence of fracture blisters in pilon fractures are associated with significant delays in time to definitive fixation and higher energy fracture patterns. Fracture blisters are less commonly located over the posterior ankle which may support the implementation of a staged posterolateral approach when managing these injures.


Asunto(s)
Fracturas de Tobillo , Traumatismos del Tobillo , Fracturas de la Tibia , Humanos , Vesícula/etiología , Resultado del Tratamiento , Traumatismos del Tobillo/cirugía , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Fijación de Fractura/efectos adversos , Fijación de Fractura/métodos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos
15.
Eur J Orthop Surg Traumatol ; 34(1): 353-361, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37530905

RESUMEN

BACKGROUND: The management of failed tibial fracture fixation remains a challenge for orthopaedic surgeons. This study investigate the utility and outcomes of circular external fixation in the management of failed internal fixation of tibial fractures. METHODS: Retrospective review of a prospectively collected database of a complex limb reconstruction unit at a major trauma centre was done during December 2022. Patients with failed internal fixation of tibial fracture who underwent revision surgery with circular external fixation frame were included. RESULTS: 20 patients with a mean age of 47.8 ± 16.5 years (range: 15-69) were included. Fourteen (70.0%) patients had failed plate and screws fixations, and the remaining six (30.0%) failed intramedullary nail fixation. The most common indication for revision surgery was development of early postoperative surgical site infection (5 patients; 25.0%). The mean duration of frame treatment was 199.5 ± 80.1 days (range = 49-364), while the mean follow-up duration following frame removal was 3.2 ± 1.8 years (range = 2-8). The overall union rate in this series was 100%; and all infected cases had complete resolution from infection. The total number of complications was 11, however, only two complications required surgical intervention. The most common complications reported were pin site infection (6; 30.0%) and limb length discrepancy of 2 cm (2; 10.0%). CONCLUSIONS: Circular external fixation is a reliable surgical option in the treatment of failed internal fixation of tibia fractures. This technique can provide limb salvage in complex infected and noninfected cases with a high union rate and minimal major complications.


Asunto(s)
Tibia , Fracturas de la Tibia , Humanos , Adulto , Persona de Mediana Edad , Tibia/cirugía , Fijación de Fractura/efectos adversos , Fijación de Fractura/métodos , Fijadores Externos , Resultado del Tratamiento , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fracturas de la Tibia/cirugía , Estudios Retrospectivos
16.
Eur J Orthop Surg Traumatol ; 34(5): 2457-2464, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38796813

RESUMEN

PURPOSE: Ankle fracture-dislocations (AFD) often necessitate staged management involving temporary external fixation (EF) due to mechanical instability or blistering. However, limited literature exists on the optimal temporary immobilization method for low-energy closed AFD. This study compared baseline patient and fracture characteristics, along with clinical and radiological outcomes between AFD initially immobilized with EF versus splinting. METHODS: A retrospective cohort study was conducted involving patients with AFD temporarily immobilized using EF or splinting, followed by definitive open reduction and internal fixation. Quality of reduction (QOR) was assessed for each patient post-initial immobilization and after the definitive surgery. RESULTS: The study encompassed 194 patients: 138 treated with a splint (71.1%) and 56 (28.9%) with EF. Secondary loss of reduction had occurred in three patients who were splinted (2.2%). The mean ages in the EF and splint groups were 63.2 and 56.1 years, respectively (p = 0.01). Posterior malleolus fracture (PMF) and blisters were more prevalent in EF patients (69.6% vs. 43.5% for PMF and 76.8% vs. 20.3% for blisters, respectively; p = 0.05 and p < 0.01). Postoperative complication rates were 8.9% for EF versus 10.9% for splinting (p = 0.69). Satisfactory final QOR was attained in 79.8% of patients treated with a splint versus 64.3% with EF (p = 0.02). CONCLUSION: Patients immobilized by EF presented with poorer baseline characteristics and had more unstable injuries. Nevertheless, postoperative complication rates were comparable. Thus, EF appears to be a valuable tool for standardizing outcomes in AFD patients with a less favorable prognosis.


Asunto(s)
Fracturas de Tobillo , Fractura-Luxación , Inmovilización , Férulas (Fijadores) , Humanos , Estudios Retrospectivos , Masculino , Fracturas de Tobillo/cirugía , Femenino , Persona de Mediana Edad , Fractura-Luxación/cirugía , Fractura-Luxación/diagnóstico por imagen , Inmovilización/métodos , Fijación Interna de Fracturas/métodos , Anciano , Reducción Abierta/métodos , Adulto , Resultado del Tratamiento , Fijadores Externos
17.
Khirurgiia (Mosk) ; (5): 43-50, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38785238

RESUMEN

OBJECTIVE: To reduce the incidence of postoperative complications and mortality after conversion of external fixation device into various types of submerged osteosynthesis in patients with polytrauma. MATERIAL AND METHODS: A retrospective and prospective analysis of treatment outcomes in 351 patients with polytrauma was divided into 2 stages. At the first stage, we analyzed significant predictors of complications after conversion of osteosynthesis in the 1st group (retrospective analysis). At the second stage, we estimated the efficacy of the developed scale for assessing the risk of complications after conversion of osteosynthesis in a prospective group of patients. RESULTS: According to the complication risk assessment scale for conversion of osteosynthesis, analysis of time to surgical treatment depending on objective criteria in patients with polytrauma can significantly reduce the incidence of postoperative complications by 14% and mortality rate by 1.7%. CONCLUSION: The complication risk assessment scale after conversion of osteosynthesis will personalize the approach to timing and methods of conversion. This measure will eliminate the «second hit¼ in damage control orthopedics and improve the results of treatment.


Asunto(s)
Fijación Interna de Fracturas , Traumatismo Múltiple , Complicaciones Posoperatorias , Humanos , Masculino , Femenino , Traumatismo Múltiple/cirugía , Traumatismo Múltiple/mortalidad , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/efectos adversos , Persona de Mediana Edad , Adulto , Federación de Rusia/epidemiología , Medición de Riesgo/métodos , Estudios Retrospectivos
18.
BMC Musculoskelet Disord ; 24(1): 864, 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37936087

RESUMEN

BACKGROUND: The clinical treatment of long bone defets in the extremities caused by trauma, infection, tumours, and nonunion has been a challenge for orthopaedic surgeons. Bone transport techniques have become the only way to treat such bone defects. However, inevitable difficulties and complications related to bone transport techniques have been reported in many studies. AIM: The purpose of this study was to investigate the risk factors for complications and the effectiveness of the Ilizarov bone transport technique in the treatment of tibial bone defects. METHODS: The study was conducted in 199 patients who underwent treatment with the Ilizarov bone transport technique at our institution from May 2012 to September 2019. Patient demographic data, complications and clinical outcomes after a minimum of 2 years of follow-up were collected and retrospectively analysed. Additionally, a risk factor analysis was performed for the top three major complications. The clinical outcomes were evaluated using the Association for the Study and Application of the Method of Ilizarov (ASAMI) criteria at the last clinical follow-up. RESULTS: A total of 199 patients underwent follow-up for 12-40 months, with an average of 23.5 months, and all achieved bone healing. A total of 310 complications occurred, with an average of 1.04 minor complications and 0.48 major complications per patient. The top three complications were pin tract infection in 48 cases (61.3%), axial deviation in 86 cases (43.2%), and delayed union in 50 cases (25.13%). Multivariate analysis showed that the bone defect length (P = 0.02, OR = 5.489), the number of previous surgeries (P = 0.003, OR = 2.204), and the external fixation index (P = 0.01, OR = 1.202) were significantly correlated with pin tract infection. Bone defects of the middle 1/3 (P < 0.001, OR = 23.769), the bone defect length (P < 0.001, OR = 2.776), and the external fixation index (P < 0.001, OR = 1.154) were significantly correlated with axial deviation. The bone defect length (P = 0.003, OR = 1.242), soft tissue defects (P = 0.013, OR = 0.312) and bone defects of the distal 1/3 (P = 0.023, OR = 4.257) were significantly correlated with delayed healing. The ASAMI bone score at the last follow-up showed a rate of excellent and good bone results of 95.48% and a rate of excellent functional results of 87.94%. CONCLUSION: The Ilizarov bone transfer technique is an effective method for treating tibial bone defects, and shortening the treatment period can reduce the incidence of complications. Older patients and those with longer bone defects, a higher external fixation index, more previous operations, and defects of the middle and distal 1/3 had a higher incidence of complications.


Asunto(s)
Técnica de Ilizarov , Fracturas de la Tibia , Humanos , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Tibia/patología , Técnica de Ilizarov/efectos adversos , Cicatrización de Heridas , Resultado del Tratamiento , Fijadores Externos
19.
BMC Musculoskelet Disord ; 24(1): 899, 2023 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-37980527

RESUMEN

OBJECTIVE: The purpose of this study was to compare the therapeutic effects of Kirschner wire fixation and external fixation in the treatment of proximal humeral fractures in older children and adolescents. METHODS: A retrospective analysis was performed on the clinical data of older children and adolescents who underwent surgery at our institution for proximal humeral fractures between April 2014 and May 2022. One group (n = 28) underwent fracture reduction and Kirschner wire fixation, and the other group (n = 23) underwent external fixation. During the follow-up, the differences in shoulder joint function between the two groups were compared by analysing Quick Disabilities of the Arm, Shoulder, and Hand (Quick DASH) and Constant-Murley scores. Postoperative complications were also recorded. RESULTS: The operation time of the Kirschner wire group was shorter than that of the external fixation group (69.07 ± 11.34 min vs. 77.39 ± 15.74 min, P = 0.33). The time to remove the fixator in the external fixation group was shorter than that in the Kirschner wire group (6.74 ± 1.57 vs. 7.61 ± 1.22, P = 0.032). The Quick DASH score and Constant-Murley score of the patients in the external fixation group were significantly better than those in the Kirschner wire group at 3 months after surgery (5.63 ± 4.33 vs. 8.93 ± 6.40, P = 0.040; 93.78 ± 2.43 vs. 91.75 ± 2.15, P = 0.003). There was no significant difference in the Quick DASH score or Constant-Murley score between the patients in the external fixator group and those in the Kirschner wire group at 9 months after the operation (2.77 ± 3.14 vs. 3.17 ± 3.68, P = 0.683; 97.39 ± 1.80 vs. 96.57 ± 2.15, P = 0.152). The most common complication of the two groups was pin tract infection. The incidence rate of infection was higher in the external fixation group than that in the Kirschner wire group (9 vs. 4, P = 0.043). CONCLUSION: Both Kirschner wire fixation and external fixation of N-H III and IV proximal humeral fractures in older children and adolescents produce good outcomes. External fixation is a preferred surgical treatment option for paediatric proximal humerus fractures because early mobilization of the affected limb can be realized.


Asunto(s)
Fracturas del Húmero , Fracturas del Hombro , Humanos , Niño , Adolescente , Hilos Ortopédicos , Fijación de Fractura/efectos adversos , Fijadores Externos , Fijación Interna de Fracturas/efectos adversos , Estudios Retrospectivos , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía , Resultado del Tratamiento , Fracturas del Húmero/cirugía
20.
BMC Musculoskelet Disord ; 24(1): 832, 2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37872566

RESUMEN

PURPOSE: This study was conducted aimed at comparing the curative effect of external fixation combined with Kirschner wire fixation versus hollow screw fixation in the treatment of first metacarpal bone base fracture. METHODS: The current retrospective study included a total of 80 patients diagnosed with first metacarpal bone base fracture who were admitted in Wuxi 9th People's Hospital Affiliated to Soochow University between October 2017 and October 2020. The patients enrolled were equally divided into the combined group (40 cases, receiving external fixation combined with Kirschner wire fixation), and the control group (40 cases, receiving hollow screw fixation). Perioperative indices were collected and compared between the two groups. Pain scores before operation and three months, six months, and one year after operation were compared. Additionally, we compared the finger function in the last follow-up visit ( the follow-up period was 1 year) and rate of complications. RESULTS: Operation time, amount of bleeding, length of incision, length of hospital stay, and fracture healing time did not differ between the two groups (all P > 0.05). Pain score was comparable between the two groups before operation (P = 0.704). Despite lower results showing at 3, 6, and 12 months after operation in both groups, the pain score did not significantly differ in any time point between the two groups (all P > 0.05). Additionally, no significant differences were observed in finger function and rate of complications at the last follow-up between the two groups (both P > 0.05). CONCLUSION: External fixation combined with Kirschner wire fixation and hollow screw fixation exhibited similar curative effect in treating first metacarpal bone base fracture, indicating both surgery methods may be considered as the preferred approach.


Asunto(s)
Fracturas Óseas , Huesos del Metacarpo , Humanos , Hilos Ortopédicos , Estudios Retrospectivos , Huesos del Metacarpo/diagnóstico por imagen , Huesos del Metacarpo/cirugía , Fijadores Externos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento , Fijación de Fractura/efectos adversos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Tornillos Óseos , Dolor
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda