Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País como asunto
Tipo del documento
Publication year range
1.
Trials ; 18(1): 306, 2017 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-28683837

RESUMEN

BACKGROUND: Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. METHODS/DESIGN: This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device. DISCUSSION: This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01896219 . Registered on 5 July 2013.


Asunto(s)
Abdomen/diagnóstico por imagen , Fenómenos Electromagnéticos , Radiografía Intervencional/instrumentación , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Protocolos Clínicos , Diseño de Equipo , Francia , Humanos , Agujas , Valor Predictivo de las Pruebas , Estudios Prospectivos , Punciones , Dosis de Radiación , Exposición a la Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Intervencional/efectos adversos , Radiografía Intervencional/métodos , Proyectos de Investigación , Programas Informáticos , Factores de Tiempo , Tomografía Computarizada por Rayos X/efectos adversos
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda