Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Lung ; 202(1): 73-81, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38129333

RESUMEN

PURPOSE: Determining the cause of interstitial lung disease (ILD) remains challenging. While surgical lung biopsy remains the gold standard approach, risks associated with it may be prohibitive. Transbronchial lung cryobiopsy (TBLC) is a minimally invasive alternative with an improved safety profile and acceptable diagnostic accuracy. We retrospectively assessed whether the use of Cone Beam computed tomography guidance for TBLC (TBLC-CBCT) improves safety and diagnostic yield compared to performing TBLC with fluoroscopic guidance (TBLC-F). METHODS: A retrospective cohort review of 120 patients presenting for evaluation of newly diagnosed ILD was performed. Demographic data, pulmonary function test values, chest imaging pattern, procedural information, and final multidisciplinary discussion (MDD) diagnosis were recorded. RESULTS: 62 patients underwent TBLC-F and 58 underwent TBLC-CBCT. Patients undergoing TBLC-CBCT were older (67.86 ± 10.97 vs 61.45 ± 12.77 years, p = 0.004) and had a higher forced vital capacity percent predicted (73.80 ± 17.32% vs 66.00 ± 17.45%, p = 0.03) compared to the TBLC-F group. The average probe-to-pleura distance was 5.1 ± 2.3 mm in the TBLC-CBCT group with 4.0 ± 0.3 CBCT spins performed. Pneumothorax occurred more often in the TBLC-F group (n = 6, 9.7%) compared to the TBLC-CBCT group (n = 1, 1.7%, p = 0.06). Grade 2 bleeding only occurred in the TBLC-F group (n = 4, 6.5%). A final MDD diagnosis was obtained in 89% (n = 57) of TBLC-F patients and 95% (n = 57) of TBLC-CBCT patients. CONCLUSIONS: TBLC-CBCT appears to be safer compared to TBLC-F with both approaches facilitating an MDD diagnosis. Further studies from multiple institutions randomizing patients to each modality are needed to confirm these findings.


Asunto(s)
Biopsia , Enfermedades Pulmonares Intersticiales , Humanos , Biopsia/efectos adversos , Biopsia/métodos , Tomografía Computarizada de Haz Cónico , Fluoroscopía , Pulmón/diagnóstico por imagen , Pulmón/patología , Enfermedades Pulmonares Intersticiales/diagnóstico , Estudios Retrospectivos
2.
Int J Urol ; 31(5): 500-506, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38193342

RESUMEN

OBJECTIVE: We developed fiducial imaging-guidance markers for the prostate with less imaging artifacts than currently commercially available markers. The aim of this study was to evaluate the imaging artifacts and potential usefulness and safety of these novel fiducial imaging markers in preclinical experiments. METHODS: We selected specific metal materials and a shape that can minimize artifacts in line with a license we obtained for a metal with a gold-platinum (Au-Pt) alloy composition that maximized artifact-free MRI images. Both phantom and canine prostate tests were conducted in order to evaluate the imaging artifacts for three imaging modalities, MRI, CT and ultrasound, and the risk of migration of the markers from the site of insertion to elsewhere, as well as crushing. RESULTS: The newly developed Au-Pt material had less imaging artifacts in the MRI, CT and ultrasound imaging modalities in comparison with current commercially available fiducial markers made from gold materials only. The Au-Pt markers had sufficient strength and durability and were considered to be potentially clinically useful and safe markers. CONCLUSION: The developed Au-Pt markers could be potential tools for accurate lesion-targeted, organ-preserving therapies such as lesion-targeted focal therapy and active surveillance in addition to conventional radiation therapies.


Asunto(s)
Marcadores Fiduciales , Oro , Imagen por Resonancia Magnética , Fantasmas de Imagen , Neoplasias de la Próstata , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/terapia , Perros , Animales , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X , Artefactos , Próstata/diagnóstico por imagen , Próstata/patología , Platino (Metal) , Ultrasonografía/métodos , Humanos , Tratamientos Conservadores del Órgano/métodos
3.
Int J Hyperthermia ; 40(1): 2244706, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37574200

RESUMEN

PURPOSE: To report procedural data and outcomes of a novel image guidance technique, CT renal arteriography (CTRA), performed to target and ablate small intraparenchymal renal tumors. MATERIALS AND METHODS: We retrospectively analyzed data of 2 patients undergoing CTRA-guided ablation for 3 renal intraparenchymal tumors, from February to March 2023. We previously evaluated tumor visibility with US/CEUS, and in all cases conspicuity was poor, whereas contrast-enhanced CT (CECT) clearly depicted all hypervascular nodules. Our primary endpoint was CTRA-guidance feasibility for renal ablation, defined as the precise probe deployment inside the target tumor. The secondary endpoint was CTRA-guided ablation technical success, intended as the inclusion of the whole tumor inside the necrotic volume, with 5 mm safety margins. RENAL scores, complications, procedural time, dose length product (DLP), serum creatinine variation and hospital stay length were also recorded. RESULTS: A confident deployment of the probe tip inside the nodule was accomplished in all 3 cases, with a 100% of correct targeting. We observed immediate technical success after all 3 ablations. The 3 nodules had a RENAL score <7 points, and we encountered no complications due to line placement or ablation. The average time from preablative to postablative CTRA was 54 min (50-58min), with a DLP of 3632mGy*cm (2807-4458mGy*cm). Serum creatinine didn't show a significant variation after the procedures; both patients were hospitalized for 2 days. CONCLUSION: Preliminary data showed that CTRA-guidance might provide unique advantages over conventional CECT-guidance to assist the ablation of small renal intraparenchymal tumor not visualized on US/CEUS.


Asunto(s)
Ablación por Catéter , Neoplasias Renales , Humanos , Creatinina , Estudios Retrospectivos , Ultrasonografía Intervencional , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Neoplasias Renales/patología , Tomografía Computarizada por Rayos X , Angiografía , Ablación por Catéter/métodos , Resultado del Tratamiento
4.
J Nanobiotechnology ; 21(1): 489, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38111035

RESUMEN

Orthotopic advanced hepatic tumor resection without precise location and preoperative downstaging may cause clinical postoperative recurrence and metastasis. Early accurate monitoring and tumor size reduction based on the multifunctional diagnostic-therapeutic integration platform could improve real-time imaging-guided resection efficacy. Here, a Near-Infrared II/Photoacoustic Imaging/Magnetic Resonance Imaging (NIR-II/PAI/MRI) organic nanoplatform IRFEP-FA-DOTA-Gd (IFDG) is developed for integrated diagnosis and treatment of orthotopic hepatic tumor. The IFDG is designed rationally based on the core "S-D-A-D-S" NIR-II probe IRFEP modified with folic acid (FA) for active tumor targeting and Gd-DOTA agent for MR imaging. The IFDG exhibits several advantages, including efficient tumor tissue accumulation, good tumor margin imaging effect, and excellent photothermal conversion effect. Therefore, the IFDG could realize accurate long-term monitoring and photothermal therapy non-invasively of the hepatic tumor to reduce its size. Next, the complete resection of the hepatic tumor in situ lesions could be realized by the intraoperative real-time NIR-II imaging guidance. Notably, the preoperative downstaging strategy is confirmed to lower the postoperative recurrence rate of the liver cancer patients under middle and advanced stage effectively with fewer side effects. Overall, the designed nanoplatform demonstrates great potential as a diagnostic-therapeutic integration platform for precise imaging-guided surgical navigation of orthotopic hepatic tumors with a low recurrence rate after surgery, providing a paradigm for diagnosing and treating the advanced tumors in the future clinical translation application.


Asunto(s)
Neoplasias Hepáticas , Nanopartículas , Cirugía Asistida por Computador , Humanos , Fototerapia , Imagen por Resonancia Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Línea Celular Tumoral
5.
Skeletal Radiol ; 52(5): 951-965, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36006462

RESUMEN

Common etiologies of low back pain include degenerative arthrosis and inflammatory arthropathy of the sacroiliac joints. The diagnostic workup revolves around identifying and confirming the sacroiliac joints as a pain generator. Diagnostic sacroiliac joint injections often serve as functional additions to the diagnostic workup through eliciting a pain response that tests the hypothesis that the sacroiliac joints do or do not contribute to the patient's pain syndrome. Therapeutic sacroiliac joint injections aim to provide medium- to long-term relief of symptoms and reduce inflammatory activity and, ultimately, irreversible structural damage. Ultrasonography, fluoroscopy, computed tomography, and magnetic resonance imaging (MRI) may be used to guide sacroiliac joint injections. The populations that may benefit most from MRI-guided sacroiliac joint procedures include children, adolescents, adults of childbearing age, and patients receiving serial injections due to the ability of interventional MRI to avoid radiation exposure. Most clinical wide-bore MRI systems can be used for MRI-guided sacroiliac joint injections. Turbo spin echo pulse sequences optimized for interventional needle display visualize the needle tip with an error margin of < 1 mm or less. Published success rates of intra-articular sacroiliac joint drug delivery with MRI guidance range between 87 and 100%. The time required for MR-guided sacroiliac joint injections in adults range between 23-35 min and 40 min in children. In this article, we describe techniques for MRI-guided sacroiliac joint injections, share our practice of incorporating interventional MRI in the care of patients with sacroiliac joint mediated pain, discuss the rationales, benefits, and limitations of interventional MRI, and conclude with future developments.


Asunto(s)
Dolor de la Región Lumbar , Articulación Sacroiliaca , Adolescente , Humanos , Adulto , Niño , Articulación Sacroiliaca/diagnóstico por imagen , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/tratamiento farmacológico , Agujas , Inyecciones Intraarticulares/métodos , Imagen por Resonancia Magnética , Artralgia/tratamiento farmacológico
6.
J Vasc Surg ; 75(2): 610-617, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34492289

RESUMEN

OBJECTIVE: Endovascular procedures are now the first line option for treatment of lower extremity arterial disease. Fusion imaging guidance has been reported to reduce radiation exposure and reintervention rates during fenestrated and branched endovascular repairs, but limited literature exists on its benefits during lower extremity arterial disease endovascular procedures, and more specifically peripheral occlusive disease (POD). This study aims to evaluate the radiation exposure and technical success benefits of fusion imaging guidance in a large cohort of patients treated endovascularly for complex POD. METHODS: From January 2017 to September 2019, in a single center, all consecutive patients presenting symptomatic occlusions (Rutherford Baker categories 3 to 6) in the setting of POD and treated endovascularly were retrospectively assessed for inclusion. All procedures were performed under augmented fluoroscopy guidance (Vessel ASSIST, GE Healthcare), overlaying on live imaging the 3D path for transluminal recanalization based on the preoperative computed tomography angiography. Technical success, dose area product (DAP), total cumulated air kerma (CAK), and fluoroscopy time were collected. DAP results were compared with the literature. RESULTS: During the study period, 179 patients were treated for iliac (n = 56) or femoropopliteal (n = 123) symptomatic arterial occlusions. Technical success was reported in 171 of 179 procedures (95.5%). The use of a re-entry catheter was required to achieve technical success in 11 patients (6.1%). Mean DAP and CAK were 12.70 Gy·cm2 and 135 mGy, respectively, with a mean fluoroscopy time of 15.26 minutes. DAP and CAK were significantly higher in the iliac group when compared with the femoropopliteal group, although fluoroscopy time was not significantly different. DAP was lower than levels reported in the literature. CONCLUSIONS: Routine use of fusion imaging guidance during POD endovascular treatment is associated with low radiation exposure, high technical success, and reduced need for re-entry systems.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Angiografía por Tomografía Computarizada/métodos , Procedimientos Endovasculares/métodos , Arteria Femoral , Arteria Ilíaca , Arteria Poplítea , Cirugía Asistida por Computador/métodos , Anciano , Arteriopatías Oclusivas/diagnóstico , Femenino , Fluoroscopía/métodos , Estudios de Seguimiento , Humanos , Imagenología Tridimensional/métodos , Masculino , Estudios Retrospectivos
7.
Cancer Control ; 29: 10732748211070702, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35076322

RESUMEN

OBJECTIVES: To evaluate the feasibility, safety, and efficacy of computed tomography(CT)-guided percutaneous radiofrequency ablation (RFA) in medically inoperable older adults with clinical stage I non-small cell lung cancer (NSCLC). PATIENTS AND METHODS: We retrospectively reviewed the records of medically inoperable older adults (≥70 years) with clinical stage I NSCLC who underwent percutaneous multi-tined electrode RFA at our institution between January 2014 and December 2018. We analyzed the patients' characteristics, therapy response, survival, as well as the procedure-related complications. RESULTS: Eighteen patients (10 men and 8 women) with a mean age of 75.9 (71-85) years were treated in during the study period. The median tumor size was 25 mm (range, 19-43 mm); 10 and 8 cases involved stage T1 and T2a disease, respectively. The median follow-up duration was 25 (11-45) months. RFA was technically successful for all 18 lesions, with no treatment-related mortality. The disease control rate was 83.3% (15/18 lesions). There were 6 cases of pneumothorax: one symptomatic case requiring thoracic drainage, and five requiring no treatment. Minor complications, including pulmonary infection, chest pain, fever, and cough, were treated within 4 days (range, 1-4 days). The progression-free survival rates were 83.3%, 64.9%, and 51.9% 1, 2, and 3 years, respectively. The corresponding overall survival rates were 92.2%, 81.5%, and 54.3%, respectively. CONCLUSIONS: CT-guided percutaneous RFA is safe and effective in medically inoperable patients with stage I NSCLC and could be an alternative therapeutic strategy, particularly in older adults with early-stage peripheral lung cancer.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/cirugía , Neoplasias Pulmonares/cirugía , Ablación por Radiofrecuencia/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Estudios de Factibilidad , Femenino , Humanos , Neoplasias Pulmonares/mortalidad , Masculino , Ablación por Radiofrecuencia/mortalidad , Estudios Retrospectivos , Cirugía Asistida por Computador/mortalidad , Tasa de Supervivencia , Resultado del Tratamiento
8.
J Appl Clin Med Phys ; 23(11): e13740, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35906884

RESUMEN

PURPOSE: Beam gating with deep inspiration breath hold (DIBH) usually depends on some external surrogate to infer internal target movement, and the exact internal movement is unknown. In this study, we tracked internal targets and characterized residual motion during DIBH treatment, guided by a surface imaging system, for gastrointestinal cancer. We also report statistics on treatment time. METHODS AND MATERIALS: We included 14 gastrointestinal cancer patients treated with surface imaging-guided DIBH volumetrically modulated arc therapy, each with at least one radiopaque marker implanted near or within the target. They were treated in 25, 15, or 10 fractions. Thirteen patients received treatment for pancreatic cancer, and one underwent separate treatments for two liver metastases. The surface imaging system monitored a three-dimensional surface with ± 3 mm translation and ± 3° rotation threshold. During delivery, a kilovolt image was automatically taken every 20° or 40° gantry rotation, and the internal marker was identified from the image. The displacement and residual motion of the markers were calculated. To analyze the treatment efficiency, the treatment time of each fraction was obtained from the imaging and treatment timestamps in the record and verify system. RESULTS: Although the external surface was monitored and limited to ± 3 mm and ± 3°, significant residual internal target movement was observed in some patients. The range of residual motion was 3-21 mm. The average displacement for this cohort was 0-3 mm. In 19% of the analyzed images, the magnitude of the instantaneous displacement was > 5 mm. The mean treatment time was 17 min with a standard deviation of 4 min. CONCLUSIONS: Precaution is needed when applying surface image guidance for gastrointestinal cancer treatment. Using it as a solo DIBH technique is discouraged when the correlation between internal anatomy and patient surface is limited. Real-time radiographic verification is critical for safe treatments.


Asunto(s)
Neoplasias Gastrointestinales , Neoplasias Pancreáticas , Humanos , Contencion de la Respiración , Movimiento (Física) , Movimiento , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/radioterapia , Neoplasias Gastrointestinales/diagnóstico por imagen , Neoplasias Gastrointestinales/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos
9.
Oncology ; 99(11): 722-731, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34515198

RESUMEN

Interventional oncology plays a major role within modern oncological patient management. Image-guided thermal ablation has been recognized as a successful local therapeutic option in patients with primary and secondary malignant liver diseases, as also recalled by the recent European Society of Medical Oncology (ESMO) guidelines on colorectal metastases. As image-guided treatments may be as effective as surgery in selected patients with liver lesions, the clinical oncologist should be familiar with the indications, risks, and technical aspects of liver ablation in order to provide their patients with the best outcomes. This article provides a broad overview of the most commonly used ablation techniques and highlights the most relevant technical aspects such as the ideal setting in the operating theatre; which image-guided methods are available, including the growing application of fusion imaging; or contrast-enhanced ultrasound for guiding/monitoring the procedure. A further aim is to expand the knowledge among medical oncologists about liver ablation procedures and to provide insights into the future perspectives of percutaneous minimally invasive procedures in the liver.


Asunto(s)
Criocirugía/métodos , Electroporación/métodos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Hipertermia Inducida/métodos , Neoplasias Hepáticas/cirugía , Oncólogos , Ablación por Radiofrecuencia/métodos , Cirugía Asistida por Computador/métodos , Terapia Combinada/métodos , Humanos , Oncología Quirúrgica/métodos , Resultado del Tratamiento
10.
AJR Am J Roentgenol ; 216(5): 1291-1299, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32755214

RESUMEN

BACKGROUND. TIPS placement is an effective method for treating a number of complications of portal hypertension. Although this complex procedure has been firmly established in treatment algorithms, more data are needed to determine the most efficient and safest ways to perform the procedure. OBJECTIVE. The purpose of this study was to determine the effect of three different techniques of portal vein (PV) cannulation during TIPS placement on procedure efficiency. METHODS. The medical records of patients who underwent TIPS creation between 2005 and 2019 were reviewed. On the basis of the PV access technique used, patients were grouped as follows: group 1 (G1) included patients who underwent a transabdominal ultrasound (US)-guided technique to obtain PV access, group 2 (G2) consisted of those who underwent fluoroscopically guided wedged hepatic portography, and group 3 (G3) included those who underwent percutaneous US-guided PV guidewire placement for fluoroscopic targeting. RESULTS. Of the 264 patients who underwent TIPS creation, 54 (20.5%) were in G1, 172 (65.1%) were in G2, and 38 (14.4%) were in G3. The mean (± SD) fluoroscopic time in G1 (34.8 ± 16.6 minutes) did not differ from that in either G2 (38.9 ± 20.8 minutes; p = .09) or G3 (29.5 ± 14.6 minutes; p = .06). However, G2 patients had significantly longer fluoroscopic times than G3 patients (p = .005). The mean total anesthesia time in G1 (190.2 ± 45.6 minutes) did not differ from that in G2 (199.7 ± 59.5 minutes; p = .15). However, G3 had a mean anesthesia time (162.6 ± 39.7 minutes) that was significantly shorter than that in both G1 (p = .003) and G2 (p < .001). The mean contrast volume was significantly lower in G1 than in G2 (67.9 ± 36.8 mL vs 87.1 ± 42.9 mL; p = .005). More intrahepatic needle passes were required in G2 (median, 4 passes; interquartile range [IQR], 1-7 passes) than in G1 (median, 2 passes; IQR, 1-4 passes; p = .004) and G3 (median, 2 passes; IQR, 1-7.25 passes; p = .04). When complications in G1 and G3 were pooled, this cohort had significantly fewer complications than G2 (p = .01). CONCLUSION. Ultrasound-guided PV access and percutaneous PV guidewire placement for fluoroscopic targeting during TIPS creation are associated with shorter procedure and fluoroscopic times and potentially decreased complications. CLINICAL IMPACT. The present study helps interventional radiologists understand the safest and most efficient way to access the PV, which is a key step during TIPS placement.


Asunto(s)
Tempo Operativo , Vena Porta/diagnóstico por imagen , Derivación Portosistémica Intrahepática Transyugular/instrumentación , Derivación Portosistémica Intrahepática Transyugular/métodos , Dosis de Radiación , Ultrasonografía Intervencional/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
11.
Ann Vasc Surg ; 75: 86-93, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33823257

RESUMEN

BACKGROUND: The benefits of imaging guidance using a new fully automated fusion process (CYDAR) have been demonstrated during endovascular aortic aneurysm repair, but little is known about its use during aorto-iliac occlusive disease endovascular revascularization. The aim of this study was to evaluate the influence of CYDAR image fusion guidance during endovascular treatment of symptomatic aorto-iliac occlusive lesions, compared with control patients treated using standard 2D fluoroscopy alone. METHODS: This is a single-center randomized controlled pilot study that recruited patients undergoing aorto-iliac endovascular revascularization. RESULTS: Between January 2019 and February 2020, 37 patients with symptomatic aorto-iliac lesions were enrolled: 18 were assigned to the fusion group and 19 to the control group. Patients and lesions characteristics were well balanced between both study groups. The technical success of the procedure was 100% in the Fusion group and 94% in the control group. All radiation-related parameters were lower in the fusion compared to the control group, including: median DAP 18.5 Gy.cm2 vs. 21.8 Gy.cm2; Air Kerma 0.10 Gy vs. 0.12 Gy; fluoroscopy dose 4.2 Gy.cm2 vs. 5.1 Gy.cm2; and number of DSA 7.5 vs. 8. The volume of iodinated contrast used was higher in the fusion group: 41 mL vs. 30 mL. The total procedure time was the same in both groups:60 min vs. 60 min. CONCLUSIONS: The results of this pilot study suggest the use of fusion imaging in endovascular treatment of aorto-iliac disease results in reduction in radiation-related measured parameters with no change in procedure time and higher doses of iodinated contrast used. These results need to be further investigated in a larger, adequately powered study.


Asunto(s)
Enfermedades de la Aorta/terapia , Aortografía , Arteriopatías Oclusivas/terapia , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Arteria Ilíaca/diagnóstico por imagen , Radiografía Intervencional , Anciano , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Automatización , Procedimientos Endovasculares/efectos adversos , Femenino , Francia , Humanos , Arteria Ilíaca/fisiopatología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Factores de Tiempo , Resultado del Tratamiento
12.
Int J Hyperthermia ; 37(1): 660-667, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32552069

RESUMEN

Purpose: To evaluate feasibility, safety and efficacy of image-guided thermal ablations associated with retrograde pyeloperfusion in patients with centrally located renal tumors.Materials and methods: 48 patients (15 women, 33 men, mean age 69.1 ± 11.8) were treated with image-guided thermal ablation associated with pyeloperfusion for 58 centrally located renal tumors (mean diameter 32.3 ± 7.32 mm). 7 patients had a single kidney. Microwave and radiofrequency ablation were used. All treatments were performed with ultrasound, CT, or fusion imaging guidance under general anesthesia and simultaneous retrograde cold pyeloperfusion technique.Results: Procedure was feasible in all cases. Technical success and primary technical efficacy were reached in 51/58 (88%) and 45/54 tumors (83%). With a second ablation performed in 5 tumors, secondary technical efficacy was achieved in 50/50 (100%) tumors. Minor and major complications occurred in 8/58 (13%) and 5/58 (8%) tumors. No significative change in renal function occurred after treatment.During follow-up, 5 recurrences occurred, that were retreated with a second ablation. At last follow up (mean 32.2 ± 22.0 months), 41/48 (85%) treated patients were free from disease. The median TTP and PFS were 27.0 (range, 2.3-80.0) and 26.5 months (range, 2.3-80.0), respectively.Conclusion: Image-guided thermal ablation associated with protective pyeloperfusion is a feasible, safe, and effective treatment option for patients with central renal tumors with a minimal impact on renal function and relevant potential to avoid nephrectomy.


Asunto(s)
Carcinoma de Células Renales , Ablación por Catéter , Neoplasias Renales , Anciano , Anciano de 80 o más Años , Carcinoma de Células Renales/cirugía , Femenino , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
13.
Int J Hyperthermia ; 37(1): 1033-1045, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32873089

RESUMEN

BACKGROUND: Patient suitability for magnetic resonance-guided high intensity focused ultrasound (MRgHIFU) ablation of pelvic tumors is initially evaluated clinically for treatment feasibility using referral images, acquired using standard supine diagnostic imaging, followed by MR screening of potential patients lying on the MRgHIFU couch in a 'best-guess' treatment position. Existing evaluation methods result in ≥40% of referred patients being screened out because of tumor non-targetability. We hypothesize that this process could be improved by development of a novel algorithm for predicting tumor coverage from referral imaging. METHODS: The algorithm was developed from volunteer images and tested with patient data. MR images were acquired for five healthy volunteers and five patients with recurrent gynaecological cancer. Subjects were MR imaged supine and in oblique-supine-decubitus MRgHIFU treatment positions. Body outline and bones were segmented for all subjects, with organs-at-risk and tumors also segmented for patients. Supine images were aligned with treatment images to simulate a treatment dataset. Target coverage (of patient tumors and volunteer intra-pelvic soft tissue), i.e. the volume reachable by the MRgHIFU focus, was quantified. Target coverage predicted from supine imaging was compared to that from treatment imaging. RESULTS: Mean (±standard deviation) absolute difference between supine-predicted and treatment-predicted coverage for 5 volunteers was 9 ± 6% (range: 2-22%) and for 4 patients, was 12 ± 7% (range: 4-21%), excluding a patient with poor acoustic coupling (coverage difference was 53%). CONCLUSION: Prediction of MRgHIFU target coverage from referral imaging appears feasible, facilitating further development of automated evaluation of patient suitability for MRgHIFU.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Neoplasias Pélvicas , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Recurrencia Local de Neoplasia , Neoplasias Pélvicas/diagnóstico por imagen , Neoplasias Pélvicas/cirugía , Derivación y Consulta
14.
Curr Urol Rep ; 20(9): 48, 2019 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-31286274

RESUMEN

PURPOSE OF REVIEW: The exstrophy-epispadias complex (EEC) represents a group of congenitally acquired malformations involving the musculoskeletal, gastrointestinal, and genitourinary systems. Classic bladder exstrophy (CBE) is the most common and best studied entity within the EEC. In this review, imaging features of CBE anatomy will be presented with surgical correlation. RECENT FINDINGS: Magnetic resonance imaging (MRI) has emerged as a useful modality for pre- and postnatal assessment of the abdominal wall, pelvic floor, and gastrointestinal and genitourinary systems of children with CBE. The authors' experience supports use of preoperative MRI, in conjunction with navigational software, as a method for identifying complex CBE anatomy. Imaging facilitates surgical approach and improves visualization of complex anatomy, potentially helping to avoid complications. Continued investigation of imaging guidance in CBE repair is needed as surgical techniques improve.


Asunto(s)
Extrofia de la Vejiga/diagnóstico por imagen , Extrofia de la Vejiga/cirugía , Epispadias/diagnóstico por imagen , Epispadias/cirugía , Femenino , Humanos , Lactante , Recién Nacido , Imagen por Resonancia Magnética , Masculino , Procedimientos Quirúrgicos Urológicos
15.
J Ultrasound Med ; 38(7): 1875-1885, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30419612

RESUMEN

B-mode ultrasound imaging guidance of cannulas can be compromised by noise, artifacts, and echogenicity that is not distinctive from that of surrounding anatomy. We have modified a venovenous extracorporeal membrane oxygenation cannula by embedding piezoelectric crystals into each of its 3 blood flow ports. Each vibrating crystal acoustically interacts with a Doppler imaging signal and produces an instantaneous color marker. The aim of this study was to compare identification of the extracorporeal membrane oxygenation cannula ports by B-mode imaging versus the color Doppler marker. Unlike B-mode imaging, the color Doppler marker identified the corresponding port even in highly challenging closed-chest scans in anesthetized pigs. The method could improve guidance accuracy of cannulas by ultrasound scans.


Asunto(s)
Oxigenación por Membrana Extracorpórea/instrumentación , Ultrasonografía Doppler en Color , Ultrasonografía Intervencional/métodos , Animales , Diseño de Equipo , Porcinos
16.
J Vasc Surg ; 68(6): 1706-1713.e1, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29804734

RESUMEN

OBJECTIVE: Use of three-dimensional fusion has been shown to significantly reduce radiation exposure and contrast material use in complex (fenestrated and branched) endovascular aneurysm repair (EVAR). Cydar software (CYDAR Medical, Cambridge, United Kingdom) is a cloud-based technology that can provide imaging guidance by overlaying preoperative three-dimensional vessel anatomy from computed tomography scans onto live fluoroscopy images both in hybrid operating rooms and on mobile C-arms. The aim of this study was to determine whether radiation dose reduction would occur with the addition of fusion imaging to infrarenal repair in all imaging environments. METHODS: All patients who consented to involvement in the trial and who were treated with EVAR in our center from March 2016 until April 2017 were included. A teaching session about radiation protection and Cydar fusion software use was provided to all operators before the start of the fusion group enrollment. This group was compared with a retrospective cohort of patients treated in the same center from March 2015 to March 2016, after a dedicated program of radiation awareness and reduction was introduced. Ruptured aneurysms and complex EVAR were excluded. Preoperative and perioperative characteristics were recorded, including parameters of radiation dose, such as air kerma and dose-area product. Results were expressed in median and interquartile range. RESULTS: Forty-four patients were prospectively enrolled and compared with 21 retrospective control patients. No significant differences were found in comparing sex, body mass index, and age at repair. The median operation time (wire to wire) and fluoroscopy time were 90 (75-105) minutes and 30 (22-34) minutes, respectively, without significant differences between groups (P = .56 and P = .36). Dose-area product was nonsignificantly higher in the control group, 21.7 (8.9-85.9) Gy cm2, compared with the fusion group, 12.4 (7.5-23.4) Gy cm2 (P = .10). Air kerma product was significantly higher in the control group, 142 (61-541) mGy, compared with 82 (51-115) mGy in the fusion group (P = .03). The number of digital subtraction angiography runs was significantly lower in the fusion group (8 [6-11]) compared with the control group (10 [9-14]); (P = .03). There were no significant differences in the frequency of adverse events, endoleaks, or additional procedures required. CONCLUSIONS: When it is used in simple procedures such as infrarenal aneurysm repair, image-based fusion technology is feasible both in hybrid operating rooms and on mobile systems and leads to an overall 50% reduction in radiation dose. Fusion technology should become standard of care for centers attempting to maximize radiation dose reduction, even if capital investment of a hybrid operating room is not feasible.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Angiografía por Tomografía Computarizada/métodos , Procedimientos Endovasculares/métodos , Imagenología Tridimensional/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Intervencional/métodos , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Aortografía/efectos adversos , Nube Computacional , Angiografía por Tomografía Computarizada/efectos adversos , Procedimientos Endovasculares/efectos adversos , Estudios de Factibilidad , Femenino , Fluoroscopía , Humanos , Imagenología Tridimensional/efectos adversos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Radiografía Intervencional/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Resultado del Tratamiento
17.
Minim Invasive Ther Allied Technol ; 27(1): 27-32, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29168421

RESUMEN

Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.


Asunto(s)
Neoplasias/diagnóstico por imagen , Neoplasias/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiografía Intervencional/métodos , Técnicas de Ablación/métodos , Humanos , Biopsia Guiada por Imagen , Neoplasias/patología , Radiofármacos
18.
J Hepatol ; 66(2): 347-354, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27650284

RESUMEN

BACKGROUND & AIMS: Although ultrasonography (US) guided radiofrequency ablation (RFA) is a commonly used treatment option for early hepatocellular carcinoma (HCC), inconspicuous tumors on US limits its feasibility. Thus, we prospectively determined whether real-time US-CT/MR fusion imaging can improve the technical feasibility of RFA compared with B-mode US, and help predict local tumor progression after RFA in patients with HCC. METHODS: A total of 216 patients with 243 HCCs ⩽5cm referred for RFA were prospectively enrolled. Prior to RFA, the operators scored the visibility of tumors, and technical feasibility on a 4-point scale at both B-mode US and fusion imaging. RFA was performed with a switching monopolar system using a separable cluster electrode under fusion imaging guidance. Technique effectiveness, local tumor progression and intrahepatic remote recurrences were evaluated. RESULTS: Tumor visibility and technical feasibility were significantly improved with fusion imaging compared with B-mode US (p<0.001). Under fusion imaging guidance, the technique effectiveness of RFA for invisible tumors on B-mode US was similar to those for visible tumors (96.1% vs. 97.6%, p=0.295). Estimated cumulative incidence of local tumor progression at 24months was 4.7%, and previous treatment for other hepatic tumors (p=0.01), higher expected number of electrode insertions needed and lower technical feasibility scores (p<0.01) on fusion imaging were significant negative predictive factors for local tumor progression. CONCLUSION: Real-time fusion imaging guidance significantly improved the tumor visibility and technical feasibility of RFA in patients with HCCs compared with B-mode US, and low feasibility scores on fusion imaging was a significant negative predictive factor for local tumor progression. LAY SUMMARY: US/CT-MR fusion imaging guidance improved the tumor visibility and technical feasibility of RFA in patients with HCCs. In addition, fusion imaging guided RFA using multiple electrodes demonstrated a high technique effectiveness rate and a low local tumor progression rate during mid-term follow-up. Clinical trial number: ClinicalTrials.gov number, NCT02687113.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter/métodos , Neoplasias Hepáticas , Imagen Multimodal/métodos , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/cirugía , Estudios de Factibilidad , Femenino , Humanos , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética Intervencional/métodos , Masculino , Persona de Mediana Edad , República de Corea , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional/métodos
19.
Radiologia ; 57(4): 275-86, 2015.
Artículo en Inglés, Español | MEDLINE | ID: mdl-25766072

RESUMEN

The risks involved in surgical treatment and conventional radiotherapy in patients with early lung cancer or lung metastases often make these treatments difficult to justify. However, on the other hand, it is also unacceptable to allow these lesions to evolve freely because, left untreated, these neoplasms will usually lead to the death of the patient. In recent years, alternative local therapies have been developed, such as pulmonary radiofrequency ablation, which has proven to increase survival with a minimal risk of complications. There are common recommendations for these treatments, and although the specific indications for using one technique or another have yet to be established, there are clearly defined situations that will determine the outcome of the treatment. It is important to know these situations, because appropriate patient selection is essential for therapeutic success. This article aims to describe the characteristics and constraints of pulmonary radiofrequency ablation and to outline its role in thoracic oncology in light of the current evidence.


Asunto(s)
Ablación por Catéter , Neoplasias Pulmonares/cirugía , Neumonectomía/métodos , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Humanos
20.
Aesthet Surg J ; 34(4): 520-5, 2014 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24658062

RESUMEN

UNLABELLED: The lacrimal sac is the structure most vulnerable to injury when performing rhinoplastic osteotomies. When performed in a low lateral position or along the frontal process of the frontal-maxillary suture, osteotomies can potentially tear the medial canthal tendon and injure the underlying lacrimal sac, possibly resulting in dacryocystitis. In this case report, the authors discuss a case of dacryocystitis following primary rhinoplasty; this injury was repaired with endoscopic dacryocystorhinostomy (DCR) using a Sonopet ultrasonic bone aspirator (Stryker, Kalamazoo, Michigan) at a single institution. This method achieved nasolacrimal duct patency, and the patient continued to be symptom-free at an 18-month follow-up. This is the first reported case of recurrent dacryocystitis following rhinoplasty as treated by endoscopic DCR. LEVEL OF EVIDENCE: 5.


Asunto(s)
Dacriocistitis/cirugía , Dacriocistorrinostomía/métodos , Endosonografía , Rinoplastia/efectos adversos , Cirugía Asistida por Computador , Dacriocistitis/diagnóstico , Dacriocistitis/etiología , Humanos , Masculino , Recurrencia , Reoperación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda