Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 243
Filtrar
1.
J Synchrotron Radiat ; 31(Pt 1): 1-9, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38142406

RESUMEN

The African Light Source (AfLS) project is now almost eight years old. This article assesses the history, current context and future of the project. There is by now considerable momentum in building the user community, including deep training, facilitating access to current facilities, growing the scientific output, scientific networks and growing the local laboratory-scale research infrastructure. The Conceptual Design Report for the AfLS is in its final editing stages. This document specifies the socio-economic and scientific rationales and the technical aspects amongst others. The AfLS is supported by many national and Pan-African scientific professional bodies and voluntary associates across many scientific disciplines, and there are stakeholders throughout the continent and beyond. The current roadmap phases have expanded to include national and Pan-African level conversations with policy makers through new Strategic Task Force groups. The document summarizes this progress and discusses the future of the project.

2.
Proc Natl Acad Sci U S A ; 118(15)2021 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-33876757

RESUMEN

With the increasing pursuit of intelligent systems, the integration of human components into functional systems provides a promising route to the ultimate human-compatible intelligent systems. In this work, we explored the integration of the human hand as the powerless and multiplexed infrared (IR) light source in different functional systems. With the spontaneous IR radiation, the human hand provides a different option as an IR light source. Compared to engineered IR light sources, the human hand brings sustainability with no need of external power and also additional level of controllability to the functional systems. Besides the whole hand, each finger of the hand can also independently provide IR radiation, and the IR radiation from each finger can be selectively diffracted by specific gratings, which helps the hand serve as a multiplexed IR light source. Considering these advantages, we show that the human hand can be integrated into various engineered functional systems. The integration of hand in an encryption/decryption system enables both unclonable and multilevel information encryption/decryption. We also demonstrate the use of the hand in complex signal generation systems and its potential application in sign language recognition, which shows a simplified recognition process with a high level of accuracy and robustness. The use of the human hand as the IR light source provides an alternative sustainable solution that will not only reduce the power used but also help move forward the effort in the integration of human components into functional systems to increase the level of intelligence and achieve ultimate control of these systems.


Asunto(s)
Mano/fisiología , Rayos Infrarrojos , Interfaz Usuario-Computador , Seguridad Computacional , Humanos , Tecnología de la Información
3.
BMC Med Educ ; 24(1): 169, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38389076

RESUMEN

BACKGROUND: Selecting the ideal tooth shade is essential to the success of aesthetic dental restorations. Students' cognitive abilities are involved in the multifaceted and intricate process of shade matching. Hence, the present study aimed to assess and compare the shade-matching ability of undergraduate dental students in various years of dental education under clinical and correcting light. METHODS: This comparative cross-sectional study was instigated amongst male 4th, 5th, and 6th-year students of the dental complex of King Faisal University, Kingdom of Saudi Arabia. A total of 72 male dental students assessed the shade under clinical (fluorescent light) and correcting light (handheld Dental Base Light) by using VITA Classical shade guides. Statistical analysis was done using SPSS version 23 (Armonk, NY, USA). The Chi-square test was used to evaluate the association between correct and incorrect shade matching under correcting and clinical light. RESULTS: Out of 72 male students, 22(30.6%) were from the 4th year, 26(36.1%) were from the 5th year, and 24(33.3%) were from the 6th year, with a mean age of 22.92 ± 1.01 years. The majority of the 6th-year students selected shade of anterior tooth # 11 correctly under clinical and correcting light, and 3(12.5%) students selected incorrectly under clinical and correcting light, with a statistically significant association among them (p = 0.004). As far as the shade selection of the posterior tooth is concerned, a statistically significant difference was observed under clinical light among all clinical students (p = 0.008). CONCLUSION: The clinical performance of dental students in shade matching improved with advancing years of dental education. Additionally, the shade matching ability of all groups of dental students was superior under correcting light compared to conditions under clinical light.


Asunto(s)
Percepción de Color , Estudiantes de Odontología , Humanos , Masculino , Adulto Joven , Adulto , Estudios Transversales , Coloración de Prótesis , Arabia Saudita
4.
Sensors (Basel) ; 24(9)2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38732832

RESUMEN

This paper addresses the design of beam position monitor (BPM) devices suitable for fourth-generation diffraction-limited X-ray storage rings. Detailed investigations of the electromagnetic (EM) phenomena occurring inside the component under various working conditions are carried out by considering different BPM EM models defined by their geometry and materials. Moving from a theoretical characterization of the common round geometry, rhomboidal structures are studied through a careful numerical analysis relying on advanced computer-aided tools. Several critical elements, such as wakefields, pick-up signal extraction, and trapped and propagating modes, are explored from the simulation point of view and from the experimental one, by deploying a manufactured microwave test bench, which is employed to measure the radio frequency behavior of a BPM prototype built at Elettra Sincrotrone Trieste. The aim of the proposed study is to identify a satisfactory tradeoff between achievable performance and practical realizability for BPM devices operating in last-generation light sources.

5.
Nano Lett ; 23(21): 10089-10096, 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37890167

RESUMEN

An in-depth understanding of the structure-property relationships in semiconductor mixed-halide perovskites is critical for their potential applications in various light-absorbing and light-emitting optoelectronic devices. Here we show that during the crystal growth of mixed-halide CsPbBr1.2I1.8 nanocrystals (NCs), abundant Ruddlesden-Popper (RP) plane stacking faults are formed to release the lattice strain. These RP planes hinder the exchange of halide species across them, resulting in the presence of multiple nanodomains with discrete mixed-halide compositions inside a single CsPbBr1.2I1.8 NC. Photoluminescence peaks from these pre-segregated nanodomains, whose correlated intensity and wavelength variations signify the interactions of coupled quantum dots within a single CsPbBr1.2I1.8 NC, can be simultaneously resolved at cryogenic temperature. Our findings thus point to a fascinating scenario in which a semiconductor nanostructure can be further divided into multiple quantum-light sources, the interaction and manipulation of which will promote novel photophysics to facilitate their potential applications in quantum information technologies.

6.
J Synchrotron Radiat ; 30(Pt 5): 910-916, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37610345

RESUMEN

Vertical beam size measurements were carried out at Beijing Electron-Positron Collider II (BEPCII) using a phase grating and an absorption grating based on the Talbot effect. The transverse coherence of synchrotron radiation is closely related to beam size. Due to the partial coherence of the synchrotron radiation source, the coherence length can be calculated by measuring the visibility decay of interferograms recorded at different distances behind the gratings. A vertical beam size of 68.19 ± 2 µm was obtained based on the relationship between the coherence length and beam size at the 3W1 beamline of BEPCII. A comparison of the vertical emittance derived from the grating Talbot method and the synchrotron radiation visible light interferometer method was presented. The vertical emittances from the two methods are 1.41 nm rad and 1.40 nm rad, respectively. The 0.1% difference indicates that the grating Talbot method for beam size measurement is reliable. This technique has great potential for small beam size measurement of fourth-generation synchrotron radiation light sources, considering its small diffraction limitation and simple experimental setups.

7.
J Synchrotron Radiat ; 30(Pt 4): 695-707, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37163303

RESUMEN

In August 2021, the SOLEIL storage ring was restarted after the summer shutdown with a new bending magnet made entirely of permanent magnets. Producing a magnetic field of 2.8 T, it replaced one of the 32 electromagnetic dipoles (magnetic field of 1.7 T) of the ring to allow the ROCK beamline to exploit more intense photon fluxes in the hard X-ray range, thus improving the time resolution performances of the beamline for experiments carried out above 20 keV. The reduction of the new dipole magnetic gap required to produce the higher field has led to the construction and installation of a new vacuum vessel. The realization of the new dipole with permanent magnets was a technological feat due to the very strong magnetic forces. The permanent-magnet assembly required dedicated tools to be designed and constructed. Thanks to accurate magnetic measurements, a precise modelization of the new dipole was performed to identify its effects on the electron beam dynamics. The first measurements carried out on the ROCK beamline have highlighted the expected increase in photon flux, and the operation performances remain unchanged for the other beamlines. Here, the major developments and results of this innovative project are described in terms of technology, electron beam dynamics and photon beam performance on the ROCK beamline.


Asunto(s)
Imanes , Sincrotrones , Rayos X , Fotones
8.
J Synchrotron Radiat ; 30(Pt 1): 76-83, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36601928

RESUMEN

This report presents testing of a prototype cantilevered liquid-nitrogen-cooled silicon mirror. This mirror was designed to be the first mirror for the new soft X-ray beamlines to be built as part of the Advanced Light Source Upgrade. Test activities focused on fracture, heat transfer, modal response and distortion, and indicated that the mirror functions as intended.

9.
J Synchrotron Radiat ; 30(Pt 1): 35-50, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36601924

RESUMEN

A promising accelerator light source mechanism called steady-state microbunching (SSMB) is being actively studied. With the combination of strong coherent radiation from microbunching and high repetition rate of a storage ring, high-average-power narrow-band radiation can be anticipated from an SSMB storage ring, with wavelengths ranging from THz to soft X-ray. Such a novel light source could provide new opportunities for accelerator photon science like high-resolution angle-resolved photoemission spectroscopy and industrial applications like extreme ultraviolet (EUV) lithography. In this paper, a theoretical and numerical study of the average and statistical properties of coherent radiation from SSMB are presented. The results show that 1 kW average-power quasi-continuous-wave EUV radiation can be obtained from an SSMB ring provided that an average current of 1 A and a microbunch train with bunch length of 3 nm can be formed at the radiator which is assumed to be an undulator. Together with the narrow-band feature, the EUV photon flux can reach 6 × 1015 photons s-1 within a 0.1 meV energy bandwidth, which is three orders of magnitude higher than that in a conventional synchrotron source and is appealing for fundamental condensed matter physics and other research. In this theoretical investigation, we have generalized the definition and derivation of the transverse form factor of an electron beam which can quantify the impact of its transverse size on coherent radiation. In particular, it has been shown that the narrow-band feature of SSMB radiation is strongly correlated with the finite transverse electron beam size. Considering the pointlike nature of electrons and quantum nature of radiation, the coherent radiation fluctuates from microbunch to microbunch, or for a single microbunch from turn to turn. Some important results concerning the statistical properties of SSMB radiation are presented, with a brief discussion on its potential applications, for example the beam diagnostics. The presented work is of value for the development of SSMB to better serve potential synchrotron radiation users. In addition, this also sheds light on understanding the radiation characteristics of free-electron lasers, coherent harmonic generation, etc.

10.
Microb Cell Fact ; 22(1): 61, 2023 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-37004064

RESUMEN

Research development in the precise control of gene expression in plant cells is an emerging necessity that would lead to the elucidation of gene function in these biological systems. Conventional gene-interfering techniques, such as micro-RNA and short interfering RNA, have limitations in their ability to downregulate gene expression in plants within short time periods. However, nanotechnology provides a promising new avenue with new tools to overcome these challenges. Here, we show that functionalized gold nanoparticles, decorated with sense and antisense oligonucleotides (FANSAO), can serve as a remote-control optical switch for gene interference in photosynthetic plant cells. We demonstrate the potential of employing LEDs as optimal light sources to photothermally dehybridize the oligonucleotides on the surface of metallic nanostructures, consequently inducing regulation of gene expression in plant cells. We show the efficiency of metallic nanoparticles in absorbing light from an LED source and converting it to thermal energy, resulting in a local temperature increase on the surface of the gold nanoparticles. The antisense oligonucleotides are then released due to the opto-thermal heating of the nanobiosystem composed of the metallic nanoparticles and the sense-antisense oligonucleotides. By applying this approach, we silenced the Carnitine Acyl Carnitine Translocase genes at 90.7%, resulting in the accumulation of lipid bodies in microalgae cells. These results exhibit the feasibility of using functionalized gold nanoparticles with sense and antisense oligonucleotides to enhance nucleic acid delivery efficiency and, most importantly, allow for temporal control of gene silencing in plant cells. These nanobiosystems have broad applications in the development and biosynthesis of biofuels, pharmaceuticals, and specialized chemicals.


Asunto(s)
Chlamydomonas reinhardtii , Nanopartículas del Metal , Nanopartículas del Metal/química , Chlamydomonas reinhardtii/genética , Chlamydomonas reinhardtii/metabolismo , Oro/química , Silenciador del Gen , Oligonucleótidos Antisentido/genética , Oligonucleótidos Antisentido/metabolismo , Lípidos
11.
Photochem Photobiol Sci ; 22(12): 2907-2917, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37940798

RESUMEN

Some people react abnormally when exposed to sunlight by getting easily burned or develop a rash. When testing a patient's level of photosensitivity in the clinic, the UVR dose to provoke erythema is determined by the minimal erythema dose (MED) test. Subsequently, a photoprovocation test is performed to detect abnormal skin reactions by daily exposing the skin to UVR for several consecutive days. Associated problems in MED testing include choice of an even skin area for testing, patients keeping still during the test, testing with different UVR doses simultaneously, and securing clear borders of erythema. To address these issues, a MED Test Patch was developed which adheres closely to the skin to ensure sharp erythema borders and provides six irradiation fields with decremental doses of 20%. For MED testing, we constructed a solar simulator and LED lamps with peak emissions at 309 and 370 nm, small enough to be mounted directly on to the MED Test Patch and accommodate patient movements. These lamps and a 415 nm LED can also be used for provocation testing which is best performed on the back where the skin is assumed to have identical UVR sensitivity, and the area is large enough for adjacent MED and provocation test fields. Reading of erythema is still performed by visual and tactile evaluation. The UVA and UVB MED test can be performed in 1 h. The advantage of these developments is an easy-to-use, standardized test method with improved accuracy of the results.


Asunto(s)
Dermatología , Trastornos por Fotosensibilidad , Humanos , Rayos Ultravioleta/efectos adversos , Piel/efectos de la radiación , Eritema/diagnóstico , Eritema/etiología , Trastornos por Fotosensibilidad/diagnóstico
12.
Sensors (Basel) ; 23(20)2023 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-37896593

RESUMEN

A random fiber laser does not need a traditional resonant cavity and only uses the multiple scattering of disordered media to provide feedback to achieve laser output. Therefore, it has the advantages of a simple structure, narrow linewidth, and low noise and is particularly suitable for fiber optic sensors. This paper provides an introduction to the categories and corresponding principles of random fiber lasers. The research progress of random fiber lasers in the sensing field in recent years, including various aspects of random fiber lasers as low-noise light sources or sensitive elements for fiber sensing systems, is the main focus. Finally, the future development trend of random fiber lasers for optical fiber sensors is explored.

13.
Sensors (Basel) ; 23(20)2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37896651

RESUMEN

In computational color constancy, regressing illumination is one of the most common approaches to manifesting the original color appearance of an object in a real-life scene. However, this approach struggles with the challenge of accuracy arising from label vagueness, which is caused by unknown light sources, different reflection characteristics of scene objects, and extrinsic factors such as various types of imaging sensors. This article introduces a novel learning-based estimation model, an aggregate residual-in-residual transformation network (ARiRTN) architecture, by combining the inception model with the residual network and embedding residual networks into a residual network. The proposed model has two parts: the feature-map group and the ARiRTN operator. In the ARiRTN operator, all splits perform transformations simultaneously, and the resulting outputs are concatenated into their respective cardinal groups. Moreover, the proposed architecture is designed to develop multiple homogeneous branches for high cardinality, and an increased size of a set of transformations, which extends the network in width and in length. As a result of experimenting with the four most popular datasets in the field, the proposed architecture makes a compelling case that complexity increases accuracy. In other words, the combination of the two complicated networks, residual and inception networks, helps reduce overfitting, gradient distortion, and vanishing problems, and thereby contributes to improving accuracy. Our experimental results demonstrate this model's outperformance over its most advanced counterparts in terms of accuracy, as well as the robustness of illuminant invariance and camera invariance.

14.
Sensors (Basel) ; 23(4)2023 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-36850558

RESUMEN

A Tungsten-Halogen (TH) lamp is the most popular light source in NIR spectroscopy and hyperspectral imaging, which requires a warm-up to reach very high temperatures of up to 250 °C and take a long time for radiation stabilization. Consequently, it has a large enough volume to enable heat dissipation to prevent the thermal runaway of the electric circuit and turn out its power efficiency very low. These are major barriers for miniaturizing spectral systems and hyperspectral imaging devices. However, TH lamps can be replaced by pc-NIR LEDs in order to avoid high temperature and large volume. We compared the spectral emission of the available commercial pc-NIR LEDs under the same condition. As a replacement for the TH lamp, the VIS + NIR LED module was developed to combine a warm-white LED and pc-NIR LEDs. In order to feature out the availability of the VIS + NIR LED module against the TH lamp, they were used as the light source for evaluating the Soluble Solid Content (SSC) of an apple through VIS-NIR spectroscopy. The results show a remarkable feasibility in the performance of the partial least square (PLS) model using the VIS + NIR LED module; during PLS calibration, the correlation coefficient (R) values are 0.664 and 0.701, and the Mean Square Error (MSE) values are 0.681 and 0.602 for the TH lamp and VIS + NIR LED module, respectively. In VIS-NIR spectroscopy, this study indicates that the TH lamp could be replaceable with a warm-white LED and pc-NIR LEDs.

15.
Nano Lett ; 22(17): 6923-6929, 2022 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-36006735

RESUMEN

Excitons in two-dimensional (2D) materials have attracted the attention of the community to develop improved photoelectronic devices. Previous reports are based on direct excitation where the out-of-plane illumination projects a uniform single-mode light spot. However, because of the optical diffraction limit, the minimal spot size is a few micrometers, inhibiting the precise manipulation and control of excitons at the nanoscale level. Herein, we introduced the in-plane coherent surface plasmonic interference (SPI) field to excite and modulate excitons remotely. Compared to the out-of-plane light, a uniform in-plane SPI suggests a more compact spatial volume and an abundance of mode selections for a single or an array of device modulation. Our results not only build up a fundamental platform for operating and encoding the exciton states at the nanoscale level but also provide a new avenue toward all-optical integrated valleytronic chips for future quantum computation and information applications.

16.
J Synchrotron Radiat ; 29(Pt 1): 118-124, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985429

RESUMEN

The Hybrid Ring with a superconducting-linac injector as a highly flexible synchrotron radiation source to enable new experimental techniques and enhance many existing ones is proposed. It is designed to be operated with the coexistence of the storage (SR) bunches characterized by the performance of the storage ring, and the single-pass (SP) bunches characterized by the performance of the superconducting linac. Unique experiments can be performed by simultaneous use of the SR and SP beams, in addition to research with various experimental techniques utilizing the versatile SR beam and research in the field of ultrafast dynamics utilizing the ultrashort pulse of the SP beam. The extendability of the Hybrid Ring will allow it to be developed into a synchrotron radiation complex.

17.
J Synchrotron Radiat ; 29(Pt 1): 159-166, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985433

RESUMEN

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

18.
J Synchrotron Radiat ; 29(Pt 1): 80-88, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34985425

RESUMEN

The ACT experimental station of the CAT-ACT wiggler beamline at the Karlsruhe Institute of Technology (KIT) Light Source is dedicated to the investigation of radionuclide materials with radioactivities up to 1000000 times the exemption limit by various speciation techniques applying monochromatic X-rays. In this article, the latest technological developments at the ACT station that enable high-resolution X-ray absorption near-edge structure (HR-XANES) spectroscopy for low radionuclide loading samples are highlighted - encompassing the investigation of actinide elements down to 1 p.p.m. concentration - combined with a cryogenic sample environment reducing beam-induced sample alterations. One important part of this development is a versatile gas tight plexiglass encasement ensuring that all beam paths in the five-analyzer-crystal Johann-type X-ray emission spectrometer run within He atmosphere. The setup enables the easy exchange between different experiments (conventional X-ray absorption fine structure, HR-XANES, high-energy or wide-angle X-ray scattering, tender to hard X-ray spectroscopy) and opens up the possibility for the investigation of environmental samples, such as specimens containing transuranium elements from contaminated land sites or samples from sorption and diffusion experiments to mimic the far field of a breached nuclear waste repository.

20.
Sensors (Basel) ; 23(1)2022 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-36616846

RESUMEN

In a random laser (RL), optical feedback arises from multiple scattering instead of conventional mirrors. RLs generate a laser-like emission, and meanwhile take advantage of a simpler and more flexible laser configuration. The applicability of RLs as light sources and optical sensors has been proved. These applications have been extended to the biological field, with tissues as natural scattering materials. Herein, the current state of the RL properties and applications was reviewed.


Asunto(s)
Rayos Láser , Luz
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda