Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Neuroimage ; 288: 120528, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38311125

RESUMEN

Quantitative susceptibility mapping (QSM) is frequently employed in investigating brain iron related to brain development and diseases within deep gray matter (DGM). Nonetheless, the acquisition of whole-brain QSM data is time-intensive. An alternative approach, focusing the QSM specifically on areas of interest such as the DGM by reducing the field-of-view (FOV), can significantly decrease scan times. However, severe susceptibility value underestimations have been reported during QSM reconstruction with a limited FOV, largely attributable to artifacts from incorrect background field removal in the boundary region. This presents a considerable barrier to the clinical use of QSM with small spatial coverages using conventional methods alone. To mitigate the propagation of these errors, we proposed a harmonic field extension method based on a physics-informed generative adversarial network. Both quantitative and qualitative results demonstrate that our method outperforms conventional methods and delivers results comparable to those obtained with full FOV. Furthermore, we demonstrate the versatility of our method by applying it to data acquired prospectively with limited FOV and to data from patients with Parkinson's disease. The method has shown significant improvements in local field results, with QSM outcomes. In a clear illustration of its feasibility and effectiveness in real clinical environments, our proposed method addresses the prevalent issue of susceptibility underestimation in QSM with small spatial coverage.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Encéfalo/diagnóstico por imagen , Mapeo Encefálico/métodos
2.
J Appl Clin Med Phys ; 24(5): e13912, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36659871

RESUMEN

PURPOSE: The aim of this study was to evaluate generalization ability of segmentation accuracy for limited FOV CBCT in the male pelvic region using a full-image CNN. Auto-segmentation accuracy was evaluated using various datasets with different intensity distributions and FOV sizes. METHODS: A total of 171 CBCT datasets from patients with prostate cancer were enrolled. There were 151, 10, and 10 CBCT datasets acquired from Vero4DRT, TrueBeam STx, and Clinac-iX, respectively. The FOV for Vero4DRT, TrueBeam STx, and Clinac-iX was 20, 26, and 25 cm, respectively. The ROIs, including the bladder, prostate, rectum, and seminal vesicles, were manually delineated. The U2 -Net CNN network architecture was used to train the segmentation model. A total of 131 limited FOV CBCT datasets from Vero4DRT were used for training (104 datasets) and validation (27 datasets); thereafter the rest were for testing. The training routine was set to save the best weight values when the DSC in the validation set was maximized. Segmentation accuracy was qualitatively and quantitatively evaluated between the ground truth and predicted ROIs in the different testing datasets. RESULTS: The mean scores ± standard deviation of visual evaluation for bladder, prostate, rectum, and seminal vesicle in all treatment machines were 1.0 ± 0.7, 1.5 ± 0.6, 1.4 ± 0.6, and 2.1 ± 0.8 points, respectively. The median DSC values for all imaging devices were ≥0.94 for the bladder, 0.84-0.87 for the prostate and rectum, and 0.48-0.69 for the seminal vesicles. Although the DSC values for the bladder and seminal vesicles were significantly different among the three imaging devices, the DSC value of the bladder changed by less than 1% point. The median MSD values for all imaging devices were ≤1.2 mm for the bladder and 1.4-2.2 mm for the prostate, rectum, and seminal vesicles. The MSD values for the seminal vesicles were significantly different between the three imaging devices. CONCLUSION: The proposed method is effective for testing datasets with different intensity distributions and FOV from training datasets.


Asunto(s)
Aprendizaje Profundo , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Masculino , Planificación de la Radioterapia Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Pelvis/diagnóstico por imagen
3.
Comput Assist Surg (Abingdon) ; 29(1): 2327981, 2024 12.
Artículo en Inglés | MEDLINE | ID: mdl-38468391

RESUMEN

Radiotherapy commonly utilizes cone beam computed tomography (CBCT) for patient positioning and treatment monitoring. CBCT is deemed to be secure for patients, making it suitable for the delivery of fractional doses. However, limitations such as a narrow field of view, beam hardening, scattered radiation artifacts, and variability in pixel intensity hinder the direct use of raw CBCT for dose recalculation during treatment. To address this issue, reliable correction techniques are necessary to remove artifacts and remap pixel intensity into Hounsfield Units (HU) values. This study proposes a deep-learning framework for calibrating CBCT images acquired with narrow field of view (FOV) systems and demonstrates its potential use in proton treatment planning updates. Cycle-consistent generative adversarial networks (cGAN) processes raw CBCT to reduce scatter and remap HU. Monte Carlo simulation is used to generate CBCT scans, enabling the possibility to focus solely on the algorithm's ability to reduce artifacts and cupping effects without considering intra-patient longitudinal variability and producing a fair comparison between planning CT (pCT) and calibrated CBCT dosimetry. To showcase the viability of the approach using real-world data, experiments were also conducted using real CBCT. Tests were performed on a publicly available dataset of 40 patients who received ablative radiation therapy for pancreatic cancer. The simulated CBCT calibration led to a difference in proton dosimetry of less than 2%, compared to the planning CT. The potential toxicity effect on the organs at risk decreased from about 50% (uncalibrated) up the 2% (calibrated). The gamma pass rate at 3%/2 mm produced an improvement of about 37% in replicating the prescribed dose before and after calibration (53.78% vs 90.26%). Real data also confirmed this with slightly inferior performances for the same criteria (65.36% vs 87.20%). These results may confirm that generative artificial intelligence brings the use of narrow FOV CBCT scans incrementally closer to clinical translation in proton therapy planning updates.


Asunto(s)
Protones , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Dosificación Radioterapéutica , Inteligencia Artificial , Estudios de Factibilidad , Procesamiento de Imagen Asistido por Computador/métodos
4.
Med Phys ; 48(11): 7112-7126, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34636429

RESUMEN

PURPOSE: Cone beam computed tomography (CBCT) is a standard solution for in-room image guidance for radiation therapy. It is used to evaluate and compensate for anatomopathological changes between the dose delivery plan and the fraction delivery day. CBCT is a fast and versatile solution, but it suffers from drawbacks like low contrast and requires proper calibration to derive density values. Although these limitations are even more prominent with in-room customized CBCT systems, strategies based on deep learning have shown potential in improving image quality. As such, this article presents a method based on a convolutional neural network and a novel two-step supervised training based on the transfer learning paradigm for shading correction in CBCT volumes with narrow field of view (FOV) acquired with an ad hoc in-room system. METHODS: We designed a U-Net convolutional neural network, trained on axial slices of corresponding CT/CBCT couples. To improve the generalization capability of the network, we exploited two-stage learning using two distinct data sets. At first, the network weights were trained using synthetic CBCT scans generated from a public data set, and then only the deepest layers of the network were trained again with real-world clinical data to fine-tune the weights. Synthetic data were generated according to real data acquisition parameters. The network takes a single grayscale volume as input and outputs the same volume with corrected shading and improved HU values. RESULTS: Evaluation was carried out with a leave-one-out cross-validation, computed on 18 unique CT/CBCT pairs from six different patients from a real-world dataset. Comparing original CBCT to CT and improved CBCT to CT, we obtained an average improvement of 6 dB on peak signal-to-noise ratio (PSNR), +2% on structural similarity index measure (SSIM). The median interquartile range (IQR) Hounsfield unit (HU) difference between CBCT and CT improved from 161.37 (162.54) HU to 49.41 (66.70) HU. Region of interest (ROI)-based HU difference was narrowed by 75% in the spongy bone (femoral head), 89% in the bladder, 85% for fat, and 83% for muscle. The improvement in contrast-to-noise ratio for these ROIs was about 67%. CONCLUSIONS: We demonstrated that shading correction obtaining CT-compatible data from narrow-FOV CBCTs acquired with a customized in-room system is possible. Moreover, the transfer learning approach proved particularly beneficial for such a shading correction approach.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Tomografía Computarizada de Haz Cónico , Humanos , Procesamiento de Imagen Asistido por Computador , Aprendizaje Automático , Redes Neurales de la Computación , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda