Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Molecules ; 29(9)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38731628

RESUMEN

Fluorescence lifetime imaging microscopy (FLIM) has proven to be a useful method for analyzing various aspects of material science and biology, like the supramolecular organization of (slightly) fluorescent compounds or the metabolic activity in non-labeled cells; in particular, FLIM phasor analysis (phasor-FLIM) has the potential for an intuitive representation of complex fluorescence decays and therefore of the analyzed properties. Here we present and make available tools to fully exploit this potential, in particular by coding via hue, saturation, and intensity the phasor positions and their weights both in the phasor plot and in the microscope image. We apply these tools to analyze FLIM data acquired via two-photon microscopy to visualize: (i) different phases of the drug pioglitazone (PGZ) in solutions and/or crystals, (ii) the position in the phasor plot of non-labelled poly(lactic-co-glycolic acid) (PLGA) nanoparticles (NPs), and (iii) the effect of PGZ or PGZ-containing NPs on the metabolism of insulinoma (INS-1 E) model cells. PGZ is recognized for its efficacy in addressing insulin resistance and hyperglycemia in type 2 diabetes mellitus, and polymeric nanoparticles offer versatile platforms for drug delivery due to their biocompatibility and controlled release kinetics. This study lays the foundation for a better understanding via phasor-FLIM of the organization and effects of drugs, in particular, PGZ, within NPs, aiming at better control of encapsulation and pharmacokinetics, and potentially at novel anti-diabetics theragnostic nanotools.


Asunto(s)
Nanopartículas , Pioglitazona , Pioglitazona/farmacología , Pioglitazona/química , Nanopartículas/química , Animales , Línea Celular Tumoral , Humanos , Microscopía Fluorescente/métodos , Ratas , Copolímero de Ácido Poliláctico-Ácido Poliglicólico/química , Hipoglucemiantes/farmacología , Hipoglucemiantes/química
2.
Front Psychiatry ; 13: 902456, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35722558

RESUMEN

Artificial intelligence (AI) advancements have radically altered human production and daily living. When it comes to AI's quick rise, it facilitates the growth of China's citizens, and at the same moment, a lack of intelligence has led to several concerns regarding regulations and laws. Current investigations regarding AI on legal knowledge do not have consistent benefits in predicting adolescents' psychological status, performance, etc. The study's primary purpose is to examine the influence of AI on the legal profession and adolescent mental health using a novel cognitive fuzzy K-nearest neighbor (CF-KNN). Initially, the legal education datasets are gathered and are standardized in the pre-processing stage through the normalization technique to retrieve the unwanted noises or outliers. When normalized data are transformed into numerical features, they can be analyzed using a variational autoencoder (VAE) approach. Multi-gradient ant colony optimization (MG-ACO) is applied to select a proper subset of the features. Tree C4.5 (T-C4.5) and fitness-based logistic regression analysis (F-LRA) techniques assess the adolescent's mental health conditions. Finally, our proposed work's performance is examined and compared with classical techniques to gain our work with the greatest effectiveness. Findings are depicted in chart formation by employing the MATLAB tool.

3.
Tissue Eng Part C Methods ; 26(12): 628-636, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33256558

RESUMEN

Quantifying fiber diameter is important for characterizing electrospun polymer scaffolds. Many researchers use manual measurement methods, which can be time-consuming and variable. Semi-automated tools exist, but there is room for improvement. The current work used Matlab to develop an image analysis program to quickly and consistently measure fiber diameter in scanning electron micrographs. The new Matlab method, termed "SIMPoly" (Semiautomated Image Measurements of Polymers) was validated by using synthetic images with known fiber size and was found to be accurate. The Matlab method was also applied by three different researchers to scanning electron microscopy (SEM) images of electrospun poly(lactic-co-glycolic acid) (PLGA). Results were compared with the semi-automated DiameterJ method and a manual ImageJ measurement approach, and it was found that the Matlab-based SIMPoly method provided measurements in the expected range and with the least variability between researchers. In conclusion, this work provides and describes SIMPoly, a Matlab-based image analysis method that can simply and accurately measure polymer fiber diameters in SEM images with minimal variation between users.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Polímeros , Microscopía Electrónica de Rastreo , Andamios del Tejido
4.
IEEE J Transl Eng Health Med ; 7: 1900808, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-32166049

RESUMEN

INTRODUCTION: The electrocardiogram (ECG) plays an important role in the diagnosis of heart diseases. However, most patterns of diseases are based on old datasets and stepwise algorithms that provide limited accuracy. Improving diagnostic accuracy of the ECG can be done by applying machine learning algorithms. This requires taking existing scanned or printed ECGs of old cohorts and transforming the ECG signal to the raw digital (time (milliseconds), voltage (millivolts)) form. OBJECTIVES: We present a MATLAB-based tool and algorithm that converts a printed or scanned format of the ECG into a digitized ECG signal. METHODS: 30 ECG scanned curves are utilized in our study. An image processing method is first implemented for detecting the ECG regions of interest and extracting the ECG signals. It is followed by serial steps that digitize and validate the results. RESULTS: The validation demonstrates very high correlation values of several standard ECG parameters: PR interval 0.984 +/-0.021 (p-value < 0.001), QRS interval 1+/- SD (p-value < 0.001), QT interval 0.981 +/- 0.023 p-value < 0.001, and RR interval 1 +/- 0.001 p-value < 0.001. CONCLUSION: Digitized ECG signals from existing paper or scanned ECGs can be obtained with more than 95% of precision. This makes it possible to utilize historic ECG signals in machine learning algorithms to identify patterns of heart diseases and aid in the diagnostic and prognostic evaluation of patients with cardiovascular disease.

SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda