Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
BMC Infect Dis ; 23(1): 374, 2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37277736

RESUMEN

BACKGROUND: University students commonly received COVID-19 vaccinations before returning to U.S. campuses in the Fall of 2021. Given likely immunologic variation among students based on differences in type of primary series and/or booster dose vaccine received, we conducted serologic investigations in September and December 2021 on a large university campus in Wisconsin to assess anti-SARS-CoV-2 antibody levels. METHODS: We collected blood samples, demographic information, and COVID-19 illness and vaccination history from a convenience sample of students. Sera were analyzed for both anti-spike (anti-S) and anti-nucleocapsid (anti-N) antibody levels using World Health Organization standardized binding antibody units per milliliter (BAU/mL). Levels were compared across categorical primary COVID-19 vaccine series received and binary COVID-19 mRNA booster status. The association between anti-S levels and time since most recent vaccination dose was estimated by mixed-effects linear regression. RESULTS: In total, 356 students participated, of whom 219 (61.5%) had received a primary vaccine series of Pfizer-BioNTech or Moderna mRNA vaccines and 85 (23.9%) had received vaccines from Sinovac or Sinopharm. Median anti-S levels were significantly higher for mRNA primary vaccine series recipients (2.90 and 2.86 log [BAU/mL], respectively), compared with those who received Sinopharm or Sinovac vaccines (1.63 and 1.95 log [BAU/mL], respectively). Sinopharm and Sinovac vaccine recipients were associated with a significantly faster anti-S decline over time, compared with mRNA vaccine recipients (P <.001). By December, 48/172 (27.9%) participants reported receiving an mRNA COVID-19 vaccine booster, which reduced the anti-S antibody discrepancies between primary series vaccine types. CONCLUSIONS: Our work supports the benefit of heterologous boosting against COVID-19. COVID-19 mRNA vaccine booster doses were associated with increases in anti-SARS-CoV-2 antibody levels; following an mRNA booster dose, students with both mRNA and non-mRNA primary series receipt were associated with comparable levels of anti-S IgG.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Humanos , COVID-19/prevención & control , Wisconsin/epidemiología , Universidades , Anticuerpos Antivirales , ARN Mensajero
2.
BMC Psychiatry ; 23(1): 396, 2023 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-37270510

RESUMEN

BACKGROUND: There is increasing evidence that immune dysfunction plays an important role in the pathogenesis of schizophrenia. Meso Scale Discovery (MSD) is bioanalytical method, which can detect serum inflammatory factors in patients. MSD has higher sensitivities, capturing a narrower range of proteins compared to other methods typically used in similar studies. The present study was aimed to explore the correlation between the levels of serum inflammatory factors and psychiatric symptoms in patients with schizophrenia at different stages and investigate a wide panel of inflammatory factors as independent factors for the pathogenesis of schizophrenia. METHODS: We recruited 116 participants, including patients with first-episode schizophrenia (FEG, n = 40), recurrence patients (REG, n = 40) with relapse-episode schizophrenia, and a control group (healthy people, HP, n = 36). Patients are diagnosed according to the DSM -V. The plasma levels of IFN-γ, IL-10, IL-1ß, IL-2, IL-6, TNF-α, CRP, VEGF, IL-15, and IL-16 were tested by the MSD technique. Patient-related data was collected, including sociodemographic data, positive and negative symptom scale (PANSS), and brief psychiatric rating scale (BPRS) and subscale scores. The independent sample T test, χ2 test, Analysis of covariance (ANCOVA), the least significant difference method (LSD), Spearman's correlation test, binary logistic regression analysis and ROC curve analysis were used in this study. RESULTS: There were significant differences in serum IL-1ß (F = 2.37, P = 0.014) and IL-16 (F = 4.40, P < 0.001) levels among the three groups. The level of serum IL-1ß in the first-episode group was significantly higher than in the recurrence group (F = 0.87, P = 0.021) and control group (F = 2.03, P = 0.013), but there was no significant difference between the recurrence group and control group (F = 1.65, P = 0.806). The serum IL-16 levels in the first-episode group (F = 1.18, P < 0.001) and the recurrence group (F = 0.83, P < 0.001) were significantly higher than in the control group, and there was no significant difference between the first-episode group and the recurrence group (F = 1.65, P = 0.61). Serum IL-1ß was negatively correlated with the general psychopathological score (GPS) of PANSS (R=-0.353, P = 0.026). In the recurrence group, serum IL-16 was positively correlated with the negative score (NEG) of the PANSS scale (R = 0.335, P = 0.035) and negatively correlated with the composite score (COM) (R=-0.329, P = 0.038). In the study, IL-16 levels were an independent variable of the onset of schizophrenia both in the first-episode (OR = 1.034, P = 0.002) and recurrence groups (OR = 1.049, P = 0.003). ROC curve analysis showed that the areas under IL-16(FEG) and IL-16(REG) curves were 0.883 (95%CI:0.794-0.942) and 0.887 (95%CI:0.801-0.950). CONCLUSIONS: Serum IL-1ß and IL-16 levels were different between patients with schizophrenia and healthy people. Serum IL-1ß levels in first-episode schizophrenia and serum IL-16 levels in relapsing schizophrenia were correlated with the parts of psychiatric symptoms. The IL-16 level may be an independent factor associating with the onset of schizophrenia.


Asunto(s)
Esquizofrenia , Humanos , Interleucina-16 , Interleucina-1beta , Factor de Necrosis Tumoral alfa , Escalas de Valoración Psiquiátrica Breve
3.
Cytokine ; 111: 481-489, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29908923

RESUMEN

BACKGROUND: Quantification of biofluid cytokines is a rapidly growing area of translational research. However, comparability across the expanding number of available assay platforms for detection of the same proteins remains to be determined. We aimed to directly compare a panel of commonly measured cytokines in plasma of typically aging adults across two high sensitivity quantification platforms, Meso Scale Discovery high performance electrochemiluminiscence (HPE) and single-molecule immunosorbent assays (Simoa) by Quanterix. METHODS: 57 community-dwelling older adults completed a blood draw, neuropsychological assessment, and brain MRI as part of a healthy brain aging study. Plasma samples from the same draw dates were analyzed for IL-10, IP-10, IL-6, TNFα, and IL-1ß on HPE and Simoa, separately. Reliable detectability (coefficient of variance (CV) < 20% and outliers 3 interquartiles above the median removed), intra-assay precision, absolute concentrations, reproducibility across platforms, and concurrent associations with external variables of interest (e.g., demographics, peripheral markers of vascular health, and brain health) were examined. RESULTS: The proportion of cytokines reliably measured on HPE (87.7-93.0%) and Simoa (75.4-93.0%) did not differ (ps > 0.32), with the exception of IL-1ß which was only reliably measured using Simoa (68.4%). On average, CVs were acceptable at <8% across both platforms. Absolute measured concentrations were higher using Simoa for IL-10, IL-6, and TNFα (ps < 0.05). HPE and Simoa shared only small-to-moderate proportions of variance with one another on the same cytokine proteins (range: r = 0.26 for IL-10 to r = 0.64 for IL-6), though platform agreement did not dependent on cytokine concentrations. Cytokine ratios within each platform demonstrated similar relative patterns of up- and down-regulation across HPE and Simoa, though still significantly differed (ps < 0.001). Supporting concurrent validity, all 95% confidence intervals of the correlations between cytokines and external variables overlapped between the two platforms. Moreover, most associations were in expected directions and consistently so across platforms (e.g., IL-6 and TNFα), though with several notable exceptions for IP-10 and IL-10. CONCLUSIONS: HPE and Simoa showed comparable detectability and intra-assay precision measuring a panel of commonly examined cytokine proteins, with the exception of IL-1ß which was not reliably detected on HPE. However, Simoa demonstrated overall higher concentrations and the two platforms did not show agreement when directly compared against one another. Relative cytokine ratios and associations demonstrated similar patterns across platforms. Absolute cytokine concentrations may not be directly comparable across platforms, may be analyte dependent, and interpretation may be best limited to discussion of relative associations.


Asunto(s)
Biomarcadores/sangre , Biomarcadores/metabolismo , Citocinas/sangre , Citocinas/metabolismo , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inmunoensayo/métodos , Interleucina-10/sangre , Interleucina-10/metabolismo , Interleucina-1beta/sangre , Interleucina-1beta/metabolismo , Interleucina-6/sangre , Interleucina-6/metabolismo , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Factor de Necrosis Tumoral alfa/sangre , Factor de Necrosis Tumoral alfa/metabolismo
4.
Ann Behav Med ; 51(5): 782-786, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28281135

RESUMEN

BACKGROUND: Exposure to adverse childhood experiences (ACE) has been associated with elevated circulating inflammatory markers in adulthood. Despite the robust effect of ACE on later health outcomes, not all individuals exposed to ACE suffer from poor health. PURPOSE: The goal of this study was to evaluate whether current resilience resources may attenuate the impact of ACE on inflammatory markers among individuals with elevated C-reactive protein (CRP) levels. METHODS: Participants (N = 174) completed one-time self-report questionnaires assessing ACE exposure within the first 18 years of life and current resilience resources, and provided blood samples for interleukin-6 (IL-6) and CRP. RESULTS: Individuals who were exposed to multiple ACE had greater IL-6 than participants with lesser ACE exposure. However, current resilience resources significantly moderated this effect. Among individuals who reported multiple ACE, higher resilience resources were associated with lower IL-6 levels. CONCLUSION: These data suggest that resilience resources might attenuate the association between ACE and later health outcomes.


Asunto(s)
Adultos Sobrevivientes de Eventos Adversos Infantiles/psicología , Inflamación/psicología , Resiliencia Psicológica , Proteína C-Reactiva/metabolismo , Femenino , Humanos , Inflamación/sangre , Interleucina-6/sangre , Acontecimientos que Cambian la Vida , Masculino , Persona de Mediana Edad
5.
Methods ; 65(1): 114-26, 2014 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23872058

RESUMEN

The Fc variant of IgG2, designated as IgG2σ, was engineered with V234A/G237A /P238S/H268A/V309L/A330S/P331S substitutions to eliminate affinity for Fcγ receptors and C1q complement protein and consequently, immune effector functions. IgG2σ was compared to other previously well-characterized Fc 'muted' variants, including aglycosylated IgG1, IgG2m4 (H268Q/V309L/A330S/P331S, changes to IgG4), and IgG4 ProAlaAla (S228P/L234A/L235A) in its capacity to bind FcγRs and activate various immune-stimulatory responses. In contrast to the previously characterized muted Fc variants, which retain selective FcγR binding and effector functions, IgG2σ shows no detectable binding to the Fcγ receptors in affinity and avidity measurements, nor any detectable antibody-dependent cytotoxicity, phagocytosis, complement activity, or Fc-mediated cytokine release. Moreover, IgG2σ shows minimal immunogenic potential by T-cell epitope analysis. The circulating half-life of IgG2σ in monkeys is extended relative to IgG1 and IgG2, in spite of similar in vitro binding to recombinant FcRn. The three-dimensional structure of the Fc, needed for assessing the basis for the absence of effector function, was compared with that of IgG2 revealing a number of conformational differences near the hinge region of the CH2 domain that result from the amino acid substitutions. Modeling reveals that at least one of the key interactions with FcγRs is disrupted by a conformational change that reorients P329 to a position that prevents it from interacting with conserved W90 and W113 residues of the FcγRs. Inspection of the structure also indicated significant changes to the conformations of D270 and P329 in the CH2 domain that could negatively impact C1q binding. Thus, structural perturbations of the Fc provide a rationale for the loss of function. In toto, these properties of IgG2σ suggest that it is a superior alternative to previously described IgG variants of minimal effector function, for future therapeutic applications of non-immunostimulatory mAb and Fc-fusion platforms.


Asunto(s)
Fragmentos Fc de Inmunoglobulinas/química , Inmunoglobulina G/química , Factores Inmunológicos/química , Sustitución de Aminoácidos , Animales , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/genética , Anticuerpos Monoclonales/farmacología , Afinidad de Anticuerpos , Citotoxicidad Celular Dependiente de Anticuerpos , Sitios de Unión , Cristalografía por Rayos X , Citocinas/metabolismo , Células HEK293 , Semivida , Humanos , Fragmentos Fc de Inmunoglobulinas/genética , Fragmentos Fc de Inmunoglobulinas/farmacología , Inmunoglobulina G/genética , Inmunoglobulina G/farmacología , Factores Inmunológicos/genética , Factores Inmunológicos/farmacología , Macaca fascicularis , Masculino , Modelos Moleculares , Mutagénesis Sitio-Dirigida , Unión Proteica , Estructura Secundaria de Proteína , Receptor ErbB-2/inmunología , Receptores de IgG/química
6.
J Allergy Clin Immunol ; 132(3): 665-675.e8, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23632299

RESUMEN

BACKGROUND: Because TNF-α is increased in severe asthma, we hypothesized that TNF-α contributes to barrier dysfunction and cell activation in bronchial epithelial cells. We further hypothesized that src-family kinase inhibition would improve barrier function in healthy cells in the presence of TNF-α and directly in cultures of severe asthmatic cells where the barrier is disrupted. OBJECTIVES: We assessed the effect of TNF-α, with or without src-family kinase inhibitor SU6656, on barrier properties and cytokine release in differentiated human bronchial epithelial cultures. Further, we tested the effect of SU6656 on differentiated primary cultures from severe asthma. METHODS: Barrier properties of differentiated human bronchial epithelial air-liquid interface cultures from healthy subjects and subjects with severe asthma were assessed with transepithelial electrical resistance and fluorescent dextran passage. Proteins were detected by immunostaining or Western blot analysis and cytokines by immunoassay. Mechanisms were investigated with src kinase and other inhibitors. RESULTS: TNF-α lowered transepithelial electrical resistance and increased fluorescent dextran permeability, caused loss of occludin and claudins from tight junctions with redistribution of p120 catenin and E-cadherin from adherens junctions, and also increased endogenous TNF-α, IL-6, IL-1ß, IL-8, thymic stromal lymphoprotein, and pro-matrix metalloprotease 9 release. SU6656 reduced TNF-α-mediated paracellular permeability changes, restored occludin, p120, and E-cadherin and lowered autocrine TNF-α release. Importantly, SU6656 improved the barrier properties of severe asthmatic air-liquid interface cultures. Redistribution of E-cadherin and p120 was observed in bronchial biopsies from severe asthmatic airways. CONCLUSIONS: Inhibiting TNF-α or src kinases may be a therapeutic option to normalize barrier integrity and cytokine release in airway diseases associated with barrier dysfunction.


Asunto(s)
Asma/metabolismo , Bronquios/metabolismo , Células Epiteliales/metabolismo , Factor de Necrosis Tumoral alfa/metabolismo , Familia-src Quinasas/metabolismo , Uniones Adherentes/efectos de los fármacos , Uniones Adherentes/metabolismo , Bronquios/citología , Cadherinas/metabolismo , Cateninas/metabolismo , Células Cultivadas , Citocinas/metabolismo , Células Epiteliales/efectos de los fármacos , Humanos , Indoles/farmacología , Inhibidores de Proteínas Quinasas/farmacología , Sulfonamidas/farmacología , Uniones Estrechas/efectos de los fármacos , Uniones Estrechas/metabolismo , Factor de Necrosis Tumoral alfa/antagonistas & inhibidores , Factor de Necrosis Tumoral alfa/genética , Familia-src Quinasas/antagonistas & inhibidores , Catenina delta
7.
Pathog Immun ; 9(2): 58-78, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39165724

RESUMEN

Background: Assessing the breadth and duration of antigen-specific binding antibodies provides valuable information for evaluating interventions to treat or prevent SARS-CoV-2 infection. Multiplex immunoassays are a convenient method for rapid measurement of antibody responses but can sometimes provide discordant results, and antibody positive percent agreement for COVID-19 diagnosis can vary depending on assay type, disease severity, and population sampled. Therefore, we compared two assays marked for research applications, MSD and Bio-Plex Pro, to evaluate qualitative interpretation of serostatus and quantitative detection of antibodies of varying isotypes (IgG, IgM, and IgA) against receptor binding domain (RBD) and nucleocapsid (N) antigens. Methods: Specimens from ACTIV-2/A5401, a placebo-controlled clinical trial of the SARSCoV-2 monoclonal antibody (mAb) bamlanivimab to prevent COVID-19 disease progression, were used to evaluate the concordance of the Bio-Rad Bio-Plex Pro Human SARS-CoV-2 Serology Assay and the Meso Scale Discovery (MSD) V-PLEX COVID-19 Panel 1 serology assay in detecting and quantifying IgG, IgA, and IgM binding anti-SARS-CoV-2 antibody responses against the RBD and N antigens. Data were disaggregated by study arm, bamlanivimab dose, days post-enrollment, and presence of emerging resistance. Results: We observed 90.5% (412 of 455 tests) concordance for anti-RBD IgG and 87% (396 of 455) concordance for anti-N IgG in classifying samples as negative or positive based on assay-defined cutoffs. Antibody levels converted to the WHO standard BAU/mL were significantly correlated for all isotypes (IgG, IgM, and IgA) and SARS-CoV-2 antigen targets (RBD and N) tested that were common between the two assays (Spearman r 0.65 to 0.92, P < 0.0001). Both assays uncovered evidence of diminished host-derived IgG immune responses in participants treated with bamlanivimab compared to placebo. Assessment of immune responses in the four individuals treated with the 700 mg of bamlanivimab with emerging mAb resistance demonstrated a stronger anti-N IgG response (MSD) at day 28 (median 2.18 log BAU/mL) compared to participants treated with bamlanivimab who did not develop resistance (median 1.55 log BAU/mL). Conclusions: These data demonstrate the utility in using multiplex immunoassays for characterizing the immune responses with and without treatment in a study population and provide evidence that monoclonal antibody treatment in acute COVID-19 may have a modest negative impact on development of host IgG responses.

8.
AAPS J ; 26(3): 37, 2024 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-38548953

RESUMEN

The utilization of antibody-drug conjugates (ADCs) has gained considerable attention in the field of targeted cancer therapy due to their ability to synergistically combine the specificity of monoclonal antibodies (mAbs) and the potency of small molecular drugs. However, the immunogenic nature of the antibody component within ADCs warrants the need for robust immunogenicity testing, including a neutralizing antibody (NAb) assay. Since the mechanism of action (MOA) of the ADC is to first bind to the target cells and then release the payload intracellularly to kill the cells, the most relevant NAb assay format would be a cell-based killing assay. However, in this paper, we present a case where a cell-based killing assay could not be developed after multiple cell lines and NAb-positive controls (PC) had been tested. Surprisingly, contrary to our expectations, all NAb PCs tested exhibited an increased killing effect on the target cells, instead of the expected protective response. This unexpected phenomenon most likely is due to the non-specific internalization of drug/NAb complexes via FcγRs, as an excessive amount of human IgG1 and mouse IgG2a, but not mouse IgG1, greatly inhibited drug or drug/NAb complexes induced cell death. To overcome this obstacle, we implemented a novel cell-based binding assay utilizing the Meso Scale Discovery (MSD) platform. We also propose that an in vitro cell killing NAb assay is limited to at best monitoring the target binding and internalization induced cell death, but not by-stander killing induced by prematurely released or dead-cell released payload, hence cannot really mimic the in vivo MOA of ADC.


Asunto(s)
Inmunoconjugados , Animales , Humanos , Ratones , Inmunoconjugados/farmacología , Anticuerpos Neutralizantes , Anticuerpos Monoclonales/farmacología , Línea Celular , Inmunoglobulina G
9.
AAPS J ; 26(6): 104, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39285067

RESUMEN

Pre-existing anti-AAV antibodies can be detected using ligand binding-based assay formats. One such format is the MSD-based bridging assay, which uses sulfo-tag-labeled AAV vectors as detection reagents. However, no method has been developed to accurately measure the degree of sulfo-tag labeling on AAV vectors. To fill this gap, we developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method to assess the degree of labeling (DoL) of sulfo-tag on AAV5 vectors, enabling the measurement of the DoL on AAV5 at six increasing levels of sulfo-tag challenge ratio. In addition, a Biacore-based assay was used to evaluate the binding affinity between an anti-AAV5 monoclonal antibody and various sulfo-tag labeled AAV5 vectors. The results indicated that increased DoL of sulfo-tag labeling on AAV5 did not compromise the binding affinity.Our study further employed the MSD-bridging assay to detect the binding Signal/Noise (S/N) ratios of four anti-AAV5 monoclonal antibodies (mAbs) to various sulfo-tag-labeled AAV5 vectors. The findings revealed a strong correlation between the degree of sulfo-tag labeling and both the S/N ratios and the sensitivity of MSD bridging assays. This result underscores the importance of optimizing the labeling of detection reagents to enhance assay sensitivity for detecting anti-AAV5 antibodies.


Asunto(s)
Anticuerpos Monoclonales , Dependovirus , Vectores Genéticos , Dependovirus/genética , Dependovirus/inmunología , Anticuerpos Monoclonales/inmunología , Anticuerpos Monoclonales/química , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Afinidad de Anticuerpos/inmunología , Animales
10.
Biomark Med ; 17(9): 459-464, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37650680

RESUMEN

Objectives: Explore whether plasma IL-6 levels are similar across biomarker platforms and association with COVID-19 clinical outcomes. Methods: Plasma IL-6 concentrations were measured on 191 COVID-19 patients using the Roche Elecsys IL-6 assay and the Meso Scale Discovery assay. Results: Correlation of IL-6 levels between platforms was high (r = 0.87; 95% CI: 0.82-0.89); however, agreement was low (bias: 147.2 pg/ml; 95% limits of agreement: -489.5-783.9 pg/ml). The optimal IL-6 threshold to predict invasive mechanical ventilation and in-hospital mortality were 3- and 3.4-fold higher in Roche compared with Meso Scale Discovery, respectively. Conclusion: The absolute IL-6 threshold to predict outcomes was consistently higher using the Roche platform, and IL-6 thresholds to inform prognosis vary based on the biomarker platform.


Asunto(s)
COVID-19 , Interleucina-6 , Humanos , Inmunoensayo , Bioensayo , Unidades de Cuidados Intensivos
11.
Brain Sci ; 12(8)2022 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-35892413

RESUMEN

Humans and rodents have sexually dimorphic immune responses, which could influence the brain's response to a systemic inflammatory insult. Lipopolysaccharide (LPS) is a stimulator of the innate immune system and is routinely used in animal models to study blood-brain barrier (BBB) dysfunction under inflammatory conditions. Therefore, we examined whether inflammatory response to LPS and the associated BBB disruption differed in male and female adult rats. Rats were treated with saline or two injections of 1 mg/kg LPS and studied 24 h after the second LPS injection. Plasma isolated from trunk blood and brain tissue homogenates of the prefrontal cortex (PFC), dorsal striatum (DS), hippocampus, and cerebellum were analyzed for cytokines and chemokines using a 9-plex panel from Meso Scale Discovery. BBB disruption was analyzed with tight junction proteins claudin-5 and VE-cadherin via Western blotting and VEGF by ELISA. This allowed us to compare sex differences in the levels of individual cytokines as well as associations among cytokines and expression of tight junction proteins between the plasma and specific brain regions. Higher levels of interferon-γ, interleukin-10 (IL-10), IL-13, IL-4, CXCL-1, and VEGF in the plasma were revealed compared to the brain homogenates, and higher levels of TNFα, IL-1ß, IL-6, and IL-5 in the PFC were seen compared with plasma and other brain regions in males. Females showed higher levels of plasma CXCL1 and VEGF compared to males, and males showed higher levels of PFC TNFα, IL-6, IL-4, and VEGF compared to females. LPS induced significant increases in plasma cytokines and VEGF in both sexes. LPS did not significantly alter cytokines in brain tissue homogenates, however, it increased chemokines in the PFC, DS, and hippocampus. In the PFC, LPS produced BBB disruption, which is evident as reduced expression of claudin-5 in males and reduced expression of VE-cadherin in both sexes. Taken together, our results reveal significant sex differences in pro-inflammatory cytokine and chemokine levels in plasma and brain that were associated with BBB disruption after LPS, and validate the use of multiplex assay for plasma and brain tissue samples.

12.
J Immunol Methods ; 498: 113136, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34464605

RESUMEN

Well-characterized HPV serology assays are required to evaluate performance of biosimilar candidate vaccines, reduced dosing schedules and novel administration methods. We report characterization of an expanded assay, M9ELISA, that detects antibodies to HPV virus-like particles (VLP) of nine types using direct IgG ELISA on the Meso Scale Discovery (MSD) electrochemiluminescence platform. The method is based on the previously published M4ELISA which detects antibodies to HPV6,11,16, and 18. It has been modified to add detection of antibodies to HPV31,33,45,52 and 58, and to streamline assay and reduce background. The M9ELISA plates were prepared with purified type specific L1 + L2 VLPs coated on 10-spot/well standard MSD microplates. Results of ELISA on three serial dilutions of serum were read on MSD imager, and titers calculated using the parallel line method. Evaluations included dynamic range, assay reproducibility, and stability over time. We compared M9ELISA results to those from a pseudovirion-based neutralization assay in sera from a mixed cohort of unvaccinated and vaccinated individuals (n = ~116) and to competitive Luminex immunoassay (cLIA) results in sera from a predominantly unvaccinated cohort (n = 4426). The linear range of the assay extended over 5 logs, with inter-assay reproducibility coefficient of variation ≤25% for all types. The pre-coated plates were stable for at least 2 years. Spearman correlation of antibody titers showed excellent correlation with PBNA (r = 0.86-0.97) and moderate correlation (r = 0.52-0.68) with cLIA. Thus, the M9ELISA can serve as a useful platform for high-throughput, sensitive and simultaneous quantitation of the antibody responses to nine HPV vaccine types.


Asunto(s)
Anticuerpos Antivirales/sangre , Ensayo de Inmunoadsorción Enzimática , Inmunogenicidad Vacunal , Inmunoglobulina G/sangre , Vacunas contra Papillomavirus/inmunología , Pruebas Serológicas , Biomarcadores/sangre , Técnicas Electroquímicas , Ensayos Analíticos de Alto Rendimiento , Humanos , Mediciones Luminiscentes , Vacunas contra Papillomavirus/administración & dosificación , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
13.
J Gerontol A Biol Sci Med Sci ; 76(11): 1954-1961, 2021 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-34110415

RESUMEN

Blood-based inflammatory markers hold considerable promise for diagnosis and prognostication of age-related neurodegenerative disease, though a paucity of research has empirically tested how reliably they can be measured across different experimental runs ("batches"). We quantified the interbatch reliability of 13 cytokines and chemokines in a cross-sectional study of 92 community-dwelling older adults (mean age = 74; 48% female). Plasma aliquots from the same blood draw were parallelly processed in 2 separate batches using the same analytic platform and procedures (high-performance electrochemiluminescence by Meso Scale Discovery). Interbatch correlations (Pearson's r) ranged from small and nonsignificant (r = .13 for macrophage inflammatory protein-1 alpha [MIP-1α]) to very large (r > .90 for interferon gamma [IFNγ], interleukin-10 [IL-10], interferon gamma-induced protein 10 [IP-10], MIP-1ß, thymus and activation-regulated chemokine [TARC]) with most markers falling somewhere in between (.67 ≤ r ≤ .90 for IL-6, tumor necrosis factor alpha [TNF-α], Eotaxin, Eotaxin-3, monocyte chemoattractant protein-1 [MCP-1], MCP-4, macrophage-derived chemokine [MDC]). All markers, except for IL-6 and MCP-4, showed significant differences in absolute values between batches, with discrepancies ranging in effect size (Cohen's d) from small to moderate (0.2 ≤ |d| ≤ 0.5 for IL-10, IP-10, MDC) to large or very large (0.68 ≤ |d| ≤ 1.5 for IFNγ, TNF-α, Eotaxin, Eotaxin-3, MCP-1, MIP-1α, MIP-1ß, TARC). Relatively consistent associations with external variables of interest (age, sex, systolic blood pressure, body mass index, cognition) were observed across batches. Taken together, our results suggest heterogeneity in measurement reliability of blood-based cytokines and chemokines, with some analytes outperforming others. Future work is needed to evaluate the generalizability of these findings while identifying potential sources of batch effect measurement error.


Asunto(s)
Citocinas , Enfermedades Neurodegenerativas , Anciano , Quimiocina CCL26 , Quimiocina CCL3 , Quimiocina CCL4 , Quimiocina CXCL10 , Estudios Transversales , Femenino , Humanos , Vida Independiente , Interferón gamma , Interleucina-10 , Interleucina-6 , Masculino , Reproducibilidad de los Resultados , Factor de Necrosis Tumoral alfa
14.
Heliyon ; 7(3): e06445, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33748497

RESUMEN

BACKGROUND: Multiplex analyses allow for detection of dozens of cytokines/chemokines in small sample volumes. Although several commercially available assay kits are available, there are no comparative data in plasma measurements among pediatric or epilepsy cohorts. NEW METHOD: Cohort study of 38 children with epilepsy. We evaluated plasma levels of cytokines/chemokines using three different assays: Luminex® xMAP high-sensitivity (HS) and standard-sensitivity (SS) assays, and Meso-Scale Discovery (MSD). We calculated recovery rates of each analyte, correlation coefficients between assays, and level of agreement between measurements. We repeated analyses in a subset of samples after a single freeze-thaw cycle. RESULTS: Among ten analytes common to all assays, HS had high recovery (<15% of values extrapolated or out-of- range [OOR]) for all analytes, SS for 50%, and MSD for 40%. While several analytes had a high correlation between assays, Bland-Altman plots demonstrated assays were not interchangeable. For most analytes, a single freeze-thaw cycle decreased cytokines/chemokine measurements. There was good correlation of measurements after a freeze-thaw cycle with acceptable agreement between measurements for six of 13 (46%) analytes using HS, one of 9 (11%) for SS, and none for MSD. COMPARISON WITH EXISTING METHODS: HS assays may optimize yield in plasma for proteins of particular interest in epilepsy research, limit values extrapolated beyond the standard curve, and improve precision compared to other SS and MSD assays. CONCLUSION: Our results demonstrate assay choice may be critical to study results and support the need for a standardized approach to biomarker assessment across epilepsy research and other domains.

15.
Biomark Med ; 15(17): 1693-1708, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34743546

RESUMEN

Purpose: Neurodegenerative disorders are a global health burden with costly and invasive diagnoses relying on brain imaging technology or CSF-based biomarkers. Therefore, considerable efforts to identify blood-biomarkers for Alzheimer's (AD) and Parkinson's diseases (PD) are ongoing. Objectives: This review evaluates the blood biomarkers for AD and PD for their diagnostic value. Methods: This study systematically reviewed articles published between July 1984 and February 2021. Among 1266 papers, we selected 42 studies for a systematic review and 23 studies for meta-analysis. Results & conclusion: Our analysis highlights P-tau181, T-tau and Nfl as promising blood biomarkers for AD diagnosis. Nfl levels were consistently raised in 16 AD and three PD cohorts. P-tau181 and T-tau were also significantly increased in 12 and eight AD cohorts, respectively.


Asunto(s)
Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Biomarcadores/sangre , Enfermedad de Parkinson/sangre , Enfermedad de Parkinson/diagnóstico , Estudios de Casos y Controles , Humanos , Estudios Longitudinales , Sesgo de Publicación , Publicaciones , Riesgo
16.
Bio Protoc ; 11(3): e3910, 2021 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-33732797

RESUMEN

Densitometric analysis is often used to quantify NaV1.1 protein on immunoblots, although the sensitivity and dilution linearity of the method are usually poor. Here we present a protocol for quantification of NaV1.1 in mouse brain tissues using a Meso Scale Discovery-Electrochemiluminescence (MSD-ECL) method. MSD-ECL is based on ELISA (enzyme-linked immunosorbent assay) and uses electrochemiluminescence to produce measurable signals. Two different antibodies are used in this assay to capture and detect NaV1.1 respectively in brain tissue lysate. The specificity of the antibodies is confirmed by Scn1a gene knock-out tissue. The calibration curve standards used in this assay were generated with mouse liver lysate spiked with mouse brain lysate, instead of using a recombinant protein. We showed that this method was qualified and used for quantification of NaV1.1 in mouse brain tissues with specificity, accuracy and precision.

17.
Bioanalysis ; 13(7): 575-585, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33749335

RESUMEN

Aim: To quantify the free form of a protein as a target-engagement biomarker in nonhuman primate serum, a Meso Scale Discovery ligand-binding assay was developed and qualified. Results: The initial assay produced an unexpected artifact when used to measure the free target in study samples dosed with drug. By using incurred study samples dosed with high drug levels to test assay performance, we developed an alternative assay that does not suffer from drug interference. Conclusion: Our work demonstrated that an assay designed to measure free target may not necessarily deliver reliable quantitation. In our case, incurred study samples dosed with drug proved to be useful in developing an alternative free assay that does not suffer from drug interference.


Asunto(s)
Desarrollo de Medicamentos , Preparaciones Farmacéuticas/sangre , Animales , Biomarcadores/sangre , Ligandos
18.
J Alzheimers Dis ; 80(4): 1353-1362, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33682718

RESUMEN

The detection of plasma tau and its phosphorylation is technically challenging due to the relatively low sensitivity. However, in Alzheimer's disease and other tauopathies, it is hypothesized that tau in the biofluid may serve as a biomarker. In recent years, several ultrasensitive assays have been developed, which can successfully detect tau and its phosphorylation in various biofluids, and collectively demonstrated the prognostic and diagnostic value of plasma tau/phosphorylated tau. Here we have summarized the principle of four ultrasensitive assays newly developed suitable for plasma tau detection, namely single-molecule array, immunomagnetic reduction assay, enhanced immunoassay using multi-arrayed fiber optics, and meso scale discovery assay, with their advantages and applications. We have also compared these assays with traditional enzyme-linked-immunosorbent serologic assay, hoping to facilitate future tau-based biomarker discovery for Alzheimer's disease and other neurodegenerative diseases.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico , Bioensayo/métodos , Proteínas tau/sangre , Enfermedad de Alzheimer/sangre , Biomarcadores/sangre , Ensayo de Inmunoadsorción Enzimática , Humanos , Fosforilación
19.
Bioanalysis ; 12(19): 1363-1375, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32975436

RESUMEN

Aim: To re-optimize the pneumococcal (Pn) electrochemiluminescence (ECL) assay and to validate and bridge the enhanced assay to the WHO ELISA, to support the Phase III clinical trial program for V114, a 15-valent Pn conjugate vaccine. Materials & methods: The Pn ECL assay was re-optimized, validated and formally bridged to the WHO ELISA. Results: The enhanced Pn ECL assay met all prespecified validation acceptance criteria and demonstrated concordance with the WHO ELISA. The corresponding threshold value remains at 0.35 µg/ml for all 15 serotypes. Conclusion: The enhanced Pn ECL assay has been validated for the measurement of antibodies to 15 Pn capsular polysaccharides and is concordant with the WHO ELISA, supporting its use in clinical trials.


Asunto(s)
Bioensayo/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Vacunas Neumococicas/inmunología , Organización Mundial de la Salud/organización & administración , Humanos
20.
Acta Neuropathol Commun ; 8(1): 184, 2020 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-33168090

RESUMEN

A C9orf72 repeat expansion is the most common genetic cause of frontotemporal dementia (FTD) and amyotrophic lateral sclerosis. One of the suggested pathomechanisms is toxicity from dipeptide repeat proteins (DPRs), which are generated via unconventional translation of sense and antisense repeat transcripts with poly-GA, poly-GP and poly-GR being the most abundant dipeptide proteins. Animal and cellular studies highlight a neurotoxic role of poly-GR and poly-PR and to a lesser degree of poly-GA. Human post-mortem studies in contrast have been much less clear on a potential role of DPR toxicity but have largely focused on immunohistochemical methods to detect aggregated DPR inclusions. This study uses protein fractionation and sensitive immunoassays to quantify not only insoluble but also soluble poly-GA, poly-GP and poly-GR concentrations in brain homogenates of FTD patients with C9orf72 mutation across four brain regions. We show that soluble DPRs are less abundant in clinically affected areas (i.e. frontal and temporal cortices). In contrast, the cerebellum not only shows the largest DPR load but also the highest relative DPR solubility. Finally, poly-GR levels and poly-GP solubility correlate with clinical severity. These findings provide the first cross-comparison of soluble and insoluble forms of all sense DPRs and shed light on the distribution and role of soluble DPRs in the etiopathogenesis of human C9orf72-FTD.


Asunto(s)
Encéfalo/metabolismo , Dipéptidos/metabolismo , Demencia Frontotemporal/metabolismo , Polímeros/metabolismo , Proteínas/metabolismo , Anciano , Proteína C9orf72/genética , Expansión de las Repeticiones de ADN/genética , Femenino , Demencia Frontotemporal/genética , Humanos , Masculino , Persona de Mediana Edad , Secuencias Repetitivas de Aminoácido/genética , Solubilidad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda