Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Publication year range
1.
Future Microbiol ; 16: 741-751, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34082567

RESUMEN

The value of blood cultures for confirming the clinical diagnosis of sepsis is suboptimal. There is growing interest in the potential of real-time PCR technology by detection of minute amounts of pathogen DNA in patient blood samples with results available within 4-6 h. Adopting a two-step approach, we evaluated the compliance of two versions of the MicrobScan assay on a total of 748 patients with suspected bloodstream infections. The results obtained with a second version of the MicrobScan assay are characterized by increased specificity (from 95.1 to 98.2%) and sensitivity (from 76.7 to 85.1), increased throughput and the possibility of simultaneously testing different kinds of samples collected from the potential sites of infection and utilizing different syndromic panels.


Asunto(s)
Reacción en Cadena en Tiempo Real de la Polimerasa , Sepsis , Humanos , Sepsis/diagnóstico
2.
Artículo en Inglés | MEDLINE | ID: mdl-31799215

RESUMEN

The diagnosis of bloodstream infections (BSIs) still relies on blood culture (BC), but low turnaround times may hinder the early initiation of an appropriate antimicrobial therapy, thus increasing the risk of infection-related death. We describe a direct and rapid multiplex PCR-based assay capable of detecting and identifying 16 bacterial and four Candida species, as well as three antibiotic-resistance determinants, in uncultured samples. Using whole-blood samples spiked with microorganisms at low densities, we found that the MicrobScan assay had a mean limit of detection of 15.1 ± 3.3 CFU of bacteria/Candida per ml of blood. When applied to positive BC samples, the assay allowed the sensitive and specific detection of BSI pathogens, including blaKPC-, mecA-, or vanA/vanB-positive bacteria. We evaluated the assay using prospectively collected blood samples from patients with suspected BSI. The sensitivity and specificity were 86.4 and 97.0%, respectively, among patients with positive BCs for the microorganisms targeted by the assay or patients fulfilling the criteria for infection. The mean times to positive or negative assay results were 5.3 ± 0.2 and 5.1 ± 0.1 h, respectively. Fifteen of 20 patients with MicrobScan assay-positive/BC-negative samples were receiving antimicrobial therapy. In conclusion, the MicrobScan assay is well suited to complement current diagnostic methods for BSIs.


Asunto(s)
Bacteriemia/diagnóstico , Bacteriemia/microbiología , Bacterias/efectos de los fármacos , Bacterias/genética , Candida/efectos de los fármacos , Candida/genética , Candidemia/diagnóstico , Candidemia/microbiología , Reacción en Cadena de la Polimerasa Multiplex , Bacteriemia/tratamiento farmacológico , Candidemia/tratamiento farmacológico , Farmacorresistencia Bacteriana/efectos de los fármacos , Farmacorresistencia Fúngica/efectos de los fármacos , Humanos , Reacción en Cadena de la Polimerasa Multiplex/instrumentación , Reacción en Cadena de la Polimerasa Multiplex/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda