1.
Heart Lung Circ ; 31(12): 1677-1684, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36089464

RESUMEN

AIM: The Occlutech duct occluder (ODO) with a novel design has been available for closure of patent ductus arteriosus (PDA) since 2011. Available data on initial experience with the ODO have shown that operators continue to choose device sizes based on their experience with conventional duct occluders (CDO). This study postulated that occlusion of the pulmonary arterial (PA) end of the ductus should achieve satisfactory PDA closure without additional complications. Accordingly, the size of the ODO was chosen such that the larger PA diameter in the new design exceeded the PA end of the ductus by 2-3 mm and 2-4 mm for normotensive and hypertensive ducts, respectively. It sought to examine the feasibility and safety of such an approach, and compared ODO and CDO devices with respect to device sizes deployed, to ascertain if the newer design had any advantages. METHODS: This prospective study enrolled 105 infants, children and a few adults with various duct morphologies and PA pressures for ductal closure using the ODO from 2018-2020. The control group consisted of 105 ducts closed with CDO. A comparison of the two groups with respect to duct diameter and implanted device sizes was performed using appropriate statistical software. RESULTS: The study found that 40% of the ducts had moderate-to-severe pulmonary hypertension. Most ducts measured between 3-4 mm in both groups. The mean weight of the subjects in both groups was 12 kg. Although there was no change in the way that duct occluders were chosen in both groups (2-3 mm over the pulmonary artery diameter), ODO could be significantly downsized in most ducts measuring between 2.5-6.4 mm in diameter (p<0.05). CONCLUSIONS: This study found successful closure of relatively larger PDA in infants and children using smaller ODO compared with CDO, without embolisation or aortic narrowing. It also demonstrated that a different device size selection technique may be safely employed with the ODO.


Asunto(s)
Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Niño , Lactante , Adulto , Humanos , Resultado del Tratamiento , Estudios Prospectivos , Cateterismo Cardíaco/métodos , Diseño de Prótesis , Conducto Arterioso Permeable/cirugía
2.
Heart Vessels ; 36(5): 704-709, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33386412

RESUMEN

Few studies have reported the efficacy of Occlutech Figulla Flex II (FFII) device compared with Amplatzer Septal Occluder (ASO) device. The aim of this study was to examine the efficacy and safety of FFII compared with ASO for transcatheter atrial septal defect (ASD) closure. We retrospectively evaluated 190 patients using FFII and 190 patients using ASO who underwent transcatheter ASD closure. ASD characteristics were evaluated by transesophageal echocardiography. The prevalence of procedural complications, including erosion, device embolization, stroke, and new-onset atrial arrhythmia, and the presence of a residual shunt were evaluated between the two groups during 12-month follow-up. FFII was used more frequently than ASO in patients with a deficient aortic rim or septal malalignment (P = 0.02, P < 0.01, respectively). The procedural complications of erosion, device embolization, and stroke did not occur in any patients. New-onset atrial arrhythmia occurred in 3 patients of the FFII group and 4 patients of the ASO group, and the difference between the two groups was not significant (P = 0.70). A large residual shunt (≥ 3 mm) was observed in 6 patients of the FFII group and 5 patients of the ASO group, and the difference between the two groups was not significant (P = 0.76). FFII was used frequently in patients with high-risk ASD morphology; however, there was no difference in the prevalence of procedural complications or efficacy between patients using FFII and those using ASO.


Asunto(s)
Cateterismo Cardíaco/métodos , Defectos del Tabique Interatrial/cirugía , Dispositivo Oclusor Septal , Ecocardiografía Transesofágica/métodos , Femenino , Estudios de Seguimiento , Defectos del Tabique Interatrial/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
3.
Pediatr Cardiol ; 42(8): 1879-1881, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34561725

RESUMEN

Percutaneous closure of secundum atrial septal defect (sASD) in children with interrupted inferior vena cava is challenging, especially in case of deficient aortic rim. Trans-jugular access is generally preferred in this scenario. Patients with situs inversus and sASD also carry technical difficulties for transcatheter closure because of the orientation of the atrial septum. We report a successful case of percutaneous closure of a sASD with deficient aortic rim using an occlutech figulla flex II ASD device through the left internal jugular vein in a child with situs inversus, dextrocardia, and interrupted IVC. This case was facilitated by the absence of left-sided hub of the Occlutech device to provide stable opening of the device into the left atrium, whereas the ball-connection of the delivery system allowed an angle of almost 180 degrees between the device and the atrial septum.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Situs Inversus , Cateterismo Cardíaco , Niño , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/cirugía , Humanos , Venas Yugulares/diagnóstico por imagen , Venas Yugulares/cirugía , Situs Inversus/complicaciones , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen
4.
Cardiol Young ; 30(3): 444-445, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32066513

RESUMEN

We report a case of Figulla-II Occlutech septal occluder malposition with residual shunt at posteriosuperior margin of an atrial septal defect. Improvising its bioptome type delivery cable, same system was used to recapture the device and redeploy it successfully. This report highlights a potential malfunction of Figulla-II Occlutech disc and the advantage of its delivery system for retrieval of the device.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Defectos del Tabique Interatrial/terapia , Falla de Prótesis , Dispositivo Oclusor Septal , Adolescente , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Masculino , Diseño de Prótesis , Resultado del Tratamiento
5.
Cardiol Young ; 28(4): 598-601, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29513202

RESUMEN

Patent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.


Asunto(s)
Cateterismo Cardíaco/métodos , Defectos del Tabique Interventricular/cirugía , Dispositivo Oclusor Septal , Adolescente , Angiografía , Ecocardiografía , Femenino , Defectos del Tabique Interventricular/diagnóstico , Humanos , Diseño de Prótesis , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 28(3): 315-320, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27925332

RESUMEN

AIMS: Percutaneous left atrial appendage closure (LAAC) is a valuable treatment option for stroke prevention in patients with atrial fibrillation and a HAS-BLED-Score ≥3. Determinants of procedural safety events and neurological outcome of the patients with the Occlutech device (OD) are not established yet. METHODS AND RESULTS: Between 2012 and 2016, 30 patients underwent LAAC using the OD. This is a prospective study. Neurological examination and transesophageal echocardiography was performed directly before and after the procedure and after 1, 3, and 12 months. The OC was successfully implanted in 28 of the 30 enrolled patients (93%). Two patients presented a hemodynamic relevant pericardial effusion. A leak <3 mm could be documented direct after implantation in 4 patients. After 3 months, there were only 2/4 patients with persistent LAA leakage with a maximum leakage of <3 mm. The correct position of the device was confirmed in 27/28 patients during 3-month follow-up. In 2 patients, there was a thrombus at the OC. In 12 patients, a transoesophageal echocardiography was performed after 12 months. All patients (12/12) showed a correct placement of the device. None of the patients developed a clinically apparent stroke or died during follow-up. CONCLUSION: In this uncontrolled, nonrandomized study, acute and 3-month follow-up success of LAAC using OD was high. No patient showed significant neurological deficits.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Examen Neurológico , Estudios Prospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 89(4): 690-698, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-27860188

RESUMEN

AIMS: To gather current experience in Occlutech ASD device retrieval, to determine whether snaring is an effective technique and to highlight alternative retrieval techniques; METHODS AND RESULTS: United Kingdom and European Occlutech ASD device implanters reported their experience in dealing with device embolization and retrieval. Six operators reported 12 retrieval cases. Retrieval was successful in 92% (11/12), although in most cases it was not straightforward and required multiple attempts using different techniques and equipment. When each different technique or equipment combination was considered separately, there were a total of 23 retrieval attempts. Fifteen attempts involved snaring the ball on the right atrial disc of the device ("the RA pin"). In 12/15 of these attempts the snare slipped off the RA pin. In 8/15 attempts snaring eventually failed. In two cases retrieval was facilitated by elongating the device in a blood vessel. In three cases retrieval was achieved by grasping the RA pin with the jaws of the Occlutech Flex II delivery cable; CONCLUSIONS: Snares do not grip the RA pin sufficiently to reliably retrieve the device. Funnelling the device into a blood vessel or grasping the RA pin with the jaws of the delivery cable may be successful alternatives. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/métodos , Remoción de Dispositivos/métodos , Dispositivo Oclusor Septal/efectos adversos , Ecocardiografía Transesofágica , Falla de Equipo , Europa (Continente) , Estudios de Seguimiento , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/cirugía , Humanos , Estudios Retrospectivos
8.
Catheter Cardiovasc Interv ; 89(4): 718-725, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-27860161

RESUMEN

OBJECTIVE: We report our recent experience with the new Occlutech® PDA Occluder, which seems suitable especially for closure of large patent ductus arteriosus (PDA) sizes with elevated pulmonary artery pressure (PAH). BACKGROUND: Although considered a standard procedure in pediatric cath labs, closure of very large PDA (PDA/Aorta ratio > 0.5) and PAH remains a challenge. METHODS/RESULTS: The Occlutech® PDA occluder was used in eight children and adolescents (age 4-16, median 10.75 years), body weight from 14 to 54 kg (median 21 kg) with very large PDA and PAH: PDA diameter was 5-13 mm (median 10 mm); PAP/Aortic pressure ratio was 0.58-0.96. Sufficient occlusion of the PDA was documented by angiography and/or echocardiography in all cases. Four different device sizes were selected: Minimal diameter 6-14 mm (median 12 mm), length 6.3-16 mm (median 14 mm), aortic disc 13-24 mm (median 20 mm), size at the pulmonary end 8-18 mm (median 15 mm). A balloon test occlusion of the PDA was performed in five patients in order to evaulate the decline of pulmonary artery pressure or to delineate the exact anatomy of the PDA. Before release of the device, a careful "wiggle manoevre" was performed to assess the stability of the implanted device and to proof the inability to embolize to the aorta. CONCLUSIONS: With the new Occlutech® PDA Occluder closure of very large PDAs and PAH is feasible and efficient. The wider pulmonary artery end of the Occlutech® PDA Occluder offers enhanced stability and reduces the risk of embolization. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Conducto Arterioso Permeable/cirugía , Hipertensión Pulmonar/etiología , Dispositivo Oclusor Septal , Adolescente , Angiografía , Niño , Preescolar , Conducto Arterioso Permeable/complicaciones , Conducto Arterioso Permeable/diagnóstico , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/cirugía , Masculino , Diseño de Prótesis , Presión Esfenoidal Pulmonar , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
9.
Pediatr Cardiol ; 38(8): 1598-1605, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28828684

RESUMEN

The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.


Asunto(s)
Cateterismo Cardíaco/métodos , Conducto Arterioso Permeable/cirugía , Dispositivo Oclusor Septal/efectos adversos , Adolescente , Angiografía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Diseño de Prótesis/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
10.
Heart Lung Circ ; 26(3): 246-250, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27555053

RESUMEN

BACKGROUND: Percutaneous patent foramen ovale (PFO) closure is a therapeutic option to prevent recurrent cerebral ischaemia in patients with cryptogenic stroke and transient cerebral ischaemia (TIA). The apparent lack of benefit seen in previous randomised trials has, in part, reflected inclusion of patients with alternate mechanisms of stroke. The role of formal neurology involvement in accurately delineating the likely aetiology of stroke or TIA is crucial in appropriate identification of patients for device closure. Furthermore, as the benefits of device closure may accrue over time, long-term follow-up is essential to define the role of device closure in management of presumed cryptogenic stroke. METHODS: We retrospectively reviewed our experience with percutaneous PFO device closure since 2005. All subjects who underwent PFO closure at John Hunter and Lake Macquarie Private Hospitals were included in the study. All patients referred for device closure following cryptogenic stroke or TIA had first undergone formal neurology review with appropriate imaging and exclusion of paroxysmal atrial arrhythmia. Patients with a history of transient ischaemic attack (TIA) are frequently referred to a specialised clinic, aimed to identify patients with conditions not referable to cerebral ischaemia, with investigations initiated by the specialist clinic to elucidate an underlying aetiology. Outcome data was derived from the Hunter New England Area Local Health District Cardiac and Stroke Outcomes Unit, in addition to review of the medical record. The Cardiac and Stroke Outcomes Unit prospectively identified all patients presenting with stroke, TIA and atrial fibrillation. RESULTS: One hundred and twelve consecutive patients undergoing percutaneous patent foramen ovale closure between 2005 and 2015 were identified. The average age was 42.7 years and 57 (50.9%) patients were male. Cryptogenic stroke (68.8%) and transient cerebral ischaemia (23.2%) were the most common indications for PFO closure, with the Amplatzer device used in 83 cases (74.1%). Early residual shunting was visible in seven patients (6.3%), however on follow-up agitated saline study only two patients had residual shunt (1.8%). The annual risk of recurrent stroke or TIA was 0.21%. CONCLUSIONS: Percutaneous patent foramen ovale closure can be performed safely and effectively in patients with paradoxical embolism. In selected patients, following appropriate multidisciplinary specialist pre-procedural assessment, excellent long-term results with low incidence of recurrent events may be achieved.


Asunto(s)
Isquemia Encefálica , Procedimientos Quirúrgicos Cardíacos , Foramen Oval Permeable , Complicaciones Posoperatorias , Accidente Cerebrovascular , Adulto , Isquemia Encefálica/epidemiología , Isquemia Encefálica/etiología , Isquemia Encefálica/terapia , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Estudios de Seguimiento , Foramen Oval Permeable/epidemiología , Foramen Oval Permeable/cirugía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/terapia
11.
Catheter Cardiovasc Interv ; 88(4): 571-581, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27029396

RESUMEN

BACKGROUND: The Occlutech Figulla ASD device series (OFSO) shows an improved device design for interventional ASD closure, larger follow-up series are missing. METHODS: We retrospectively reviewed the feasibility, safety, implantation properties, results, and follow-up of ASD closure using Occlutech devices over a 5 year period by establishing a multi-institutional collaborative result registry with 16 contributing centers from 11 countries (IRFACODE). RESULTS: In 1315 patients of all age groups (female 66.9%), successful (98%) ASD closure was performed (mean age 28.9 years, weight 52 kg, height 148.6 cm). Of the defects, 47.9% showed no or only a deficient aortic rim; in 11.9%, there was more than one defect; a septum aneurysm was present in 21.5%; and the mean implanted device size was 20.5 mm. Immediate closure was achieved in 78.6%, at discharge in 83.1%, and 96.4% and 97.3% at 6 and 12 months follow-up, respectively. During a mean follow-up of 2.7 years (in total 3597 patient years), significant complications were minimal (total = 8, <1%) with secondary device embolizations in five and AV-blocks in three patients. No erosion or death was reported. CONCLUSION: ASD closure using OFSO is feasible in a large variety of patients, safe with only a minimal risk of severe side effects and especially without any aortic erosions despite a large percentage of large and complicated defects. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Defectos del Tabique Interatrial/terapia , Dispositivo Oclusor Septal , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Asia , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Europa (Continente) , Estudios de Factibilidad , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Lactante , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
BMC Cardiovasc Disord ; 16(1): 217, 2016 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-27832757

RESUMEN

BACKGROUND: Patients with a patent foramen ovale (PFO) who suffered from stroke, TIA or peripheral paradoxical embolism are at substantial risk for recurrent neurologic events and in need for secondary prevention. Interventional closure of PFO has been performed for over 20 years. Numerous devices have been developed and used for treatment. We investigated PFO closure with the third generation Occlutech Figulla® Flex II Occluder device. METHODS: Between 2012 and 2015 57 patients (mean age 47.3 ± 1.5 years) who had suffered from a thromboembolic event of unknown cause underwent transcatheter PFO closure with the Occlutech Figulla® Flex II Occluder at our department. 68.4 % of all patients had suffered from cryptogenic stroke, while TIA had occurred in 28.1 %. Almost all patients were diagnosed with an atrial septum aneurysm (90.9 %) and a severe right-to-left shunt grade 3: >20 microbubbles (92.0 %). Follow-up was done 6 months post intervention by clinical examination and transesophageal contrast echocardiography. RESULTS: No major periprocedural or in-hospital complication occurred. Closure was sufficient with no residual right-to-left shunt in 94.4 % of all patients at 6 months post implantation and only minimal residual shunt in three cases. There were no thrombotic formations associated to the occluder device. Atrial fibrillation occurred in one patient and a recurrent cerebral ischemic event was seen in one patient, who suffered from another TIA. CONCLUSIONS: The Occlutech Figulla® Flex II Occluder device and its delivery system is safe and provides sufficient closure of PFO in patients who suffered from cryptogenic stroke, TIA or paradoxical peripheral embolism.


Asunto(s)
Cateterismo Cardíaco/métodos , Foramen Oval Permeable/cirugía , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Ecocardiografía Transesofágica , Electrocardiografía , Femenino , Estudios de Seguimiento , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Prevención Secundaria/métodos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 86(1): 94-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25675888

RESUMEN

OBJECTIVES: To evaluate the feasibility, safety, and efficacy of the Occlutech® PDA occluder for closure of patent ductus arteriosus (PDA). BACKGROUND: The Occlutech® PDA occluder is novel, self-shaping Nitinol wire device with PET (polyethylene terephthalate) patches integrated into the shank of the device to assure a better obturation of the ductus. The Occlutech® PDA occluder has undergone two design modifications. METHODS: A prospective, non-randomized pilot study was started in November 2011. Thirty-three patients were included until April 2013. Patients weighing <6 kg or those with associated cardiac anomalies that required surgery were excluded. All patients were followed up by transthoracic echocardiography at 24 hr, 30 days, 90 days, 180 days, and 360 days after implantation. Residual shunt, left pulmonary artery (LPA) and descending aortic velocities were among the parameters assessed. All occluders were delivered via 6-8 F long sheaths and PDA closures were performed following standard techniques. RESULTS: Thirty three patients (20 female/13 male), with a median age of 2 years (6 month to 38 years), and median weight of 9.3 kg (6-69.2 kg) were included. The narrowest median PDA diameter was 3mm (1.8-5.8 mm). All the 33 patients were closed successfully using Occlutech ductal occluder, 16 patients (48.4%) had immediate and complete closure on angiography. Within 24 hr, color Doppler revealed complete closure in 27patients (81.8%), 32patients (97%) at 30 days, and in 100% of patients at 90 days. All patients with a large PDA had immediate residual shunt which was closed at the 90-day follow-up. There was no device embolization, hemolysis, or obstruction to the LPA or descending aorta. CONCLUSION: The new Occlutech® PDA is safe and effective. In patients with a large PDA complete closure tended to take longer time.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Conducto Arterioso Permeable/cirugía , Dispositivo Oclusor Septal , Adolescente , Adulto , Cateterismo Cardíaco , Niño , Preescolar , Conducto Arterioso Permeable/diagnóstico , Ecocardiografía Doppler en Color , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Proyectos Piloto , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento , Adulto Joven
14.
Front Cardiovasc Med ; 11: 1371692, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39026998

RESUMEN

Left-sided bioprosthesis valve thrombosis (LSBVT) is a challenging complication necessitating invasive interventions. In this study, we introduce a novel, minimally invasive approach. We used a cerebral embolic protection system and an Occlutech cannula connected to an extracorporeal circuit, providing safer thrombus aspiration compared to the AngioVac system. This technique offers a promising alternative for high-risk patients with LSBVT.

15.
Int J Cardiol ; 261: 54-57, 2018 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-29551254

RESUMEN

AIM: To describe our initial experience with the Occlutech Duct Occluder (ODO) for percutaneous closure of patent ductus arteriosus (PDA). METHODS: Retrospective review of patients undergoing transcatheter PDA closure with the ODO in 2 academic centers. RESULTS: From April 2013 to September 2017, 42 patients underwent PDA closure. Median age at implantation was 34 months (range 4 months-68 years) and median weight was 12 kg (range 4.1-57 kg). Ducts were Krichenko type A duct (n = 34), type E (n = 6), and type C (n = 2). The mean duct diameter was 3.76 mm (range 1.69 to 9.95 mm, median 3.1 mm). Implantation succeeded in all. There was neither device embolization nor hemolysis. At device release, immediate angiogram showed a small residual shunt in 54.7%. During follow-up, Doppler echocardiography demonstrated 71% of full occlusion at day one, rising to 95% at one month and 100% at one year and half after implantation. The mean maximal systolic pressure gradient in left pulmonary artery was 4.2 ±â€¯4.3 mm and across the distal aortic arch 5.4 ±â€¯4.7 mm Hg. No patient had any significant stenosis with clinical relevance. CONCLUSIONS: ODO is safe and effective in transcatheter closure of PDA including relatively large sized ducts. The results are satisfactory with a high level of full occlusion and a low rate of complications. Further evaluation with larger studies and longer follow-up will be required to confirm these preliminary good results.


Asunto(s)
Cateterismo Cardíaco/tendencias , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/cirugía , Diseño de Prótesis/tendencias , Dispositivo Oclusor Septal/tendencias , Adolescente , Adulto , Anciano , Cateterismo Cardíaco/normas , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Diseño de Prótesis/normas , Estudios Retrospectivos , Dispositivo Oclusor Septal/normas , Resultado del Tratamiento , Adulto Joven
16.
Ann Pediatr Cardiol ; 10(2): 131-136, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28566820

RESUMEN

BACKGROUND: Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. METHODS: Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. RESULTS: From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1-454 months) and the median weight was 8.5 kg (range 2.5-78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12-100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1-7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. CONCLUSION: The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients.

17.
Int J Cardiol ; 245: 99-104, 2017 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-28778466

RESUMEN

INTRODUCTION: Safety and efficacy data on patent foramen ovale (PFO) closure with the Occlutech Figulla Flex II device are lacking. We undertook a fully monitored prospective Registry on PFO closure using this device. METHODS: 100 patients undergoing PFO closure were enrolled into the OPPOSE Registry at 6 UK centres. The primary endpoint was PFO closure (grade 0 or 1 shunt) at 6-month BCTTE assessed by Corelab. Secondary endpoints included implantation success, complications, and atrial fibrillation during follow-up. RESULTS: 100 patients aged 43.8±11.5years, 53% male, were recruited. Indications for PFO closure included stroke (56%), TIA (29%) systemic embolism (4%) and MI (3%). Closure was undertaken under GA (44%) or LA (56%), with TOE (45%), ICE (31%), no imaging (20%) or TTE (3%). Balloon sizing was used in 98% of cases and showed a tunnel length of 7.3±3.6mm, primum-secundum separation of 7.0±2.9mm and basal inlet width of 8.5±3.5mm. Implantation was successful in all cases using 18mm (9%), 25mm (80%), 30mm (10%) and 35mm (1%) devices. 5 patients were lost to follow-up. 92 patients underwent six-month BCTTE. The primary endpoint of PFO closure (grade 0 or 1 shunt) at six months was 79.3%. One patient developed major bleeding (BARC 3b), one patient required vascular surgery, and in one patient device embolization was noted at six months and a larger device implanted. There was one case of new atrial fibrillation. CONCLUSIONS: This first prospective monitored data for the Occlutech Figulla Flex II device demonstrates good safety and efficacy data at implant and six-month follow-up.


Asunto(s)
Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/cirugía , Sistema de Registros , Dispositivo Oclusor Septal/tendencias , Adulto , Ecocardiografía Transesofágica/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dispositivo Oclusor Septal/efectos adversos , Dispositivo Oclusor Septal/normas , Resultado del Tratamiento
20.
Eur J Cardiothorac Surg ; 51(4): 702-708, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28082466

RESUMEN

Objectives: Bronchopleural fistula (BPF) is an uncommon complication following a lung resection to address various conditions. BPFs are associated with high morbidity and mortality rates. This study evaluated the endoscopic treatment of 'total' BPFs using the Occlutech-Fígulla® cardiac device at a single centre. Methods: We selected nine patients with chronic and complete BPFs. Under direct bronchoscopic visualization, the BPFs were treated using the Occlutech-Fígulla device. The patients were followed up for 12 months to determine the treatment level and complications. Results: The procedure had a favourable outcome in three patients, resulting in complete fistula closure. Two patients had partial closure and showed improvements in their clinical conditions. In two other cases, closure of the bronchial stump was unsuccessful using this method. Two patients died from causes unrelated to the procedure or the device. During the follow-up period, no complications related to infection or device-related injuries were reported. Conclusions: In patients without clinical conditions that require surgical treatment, the Occlutech-Fígulla cardiac device can be a safe and effective method for the endoscopic treatment of large BPFs resulting from complete dehiscence of a bronchial stump. No severe events were reported.


Asunto(s)
Broncoscopía/métodos , Fístula del Sistema Respiratorio/etiología , Fístula del Sistema Respiratorio/cirugía , Dehiscencia de la Herida Operatoria/complicaciones , Adulto , Anciano , Fístula Bronquial/etiología , Fístula Bronquial/cirugía , Broncoscopía/efectos adversos , Enfermedad Crónica , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Enfermedades Pleurales/etiología , Enfermedades Pleurales/cirugía , Neumonectomía/efectos adversos , Estudios Prospectivos , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento