Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Resultados 1 - 20 de 4.546
Filtrar
Más filtros

Publication year range
1.
Methods ; 225: 62-73, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38490594

RESUMEN

The multipotent stem cells of our body have been largely harnessed in biotherapeutics. However, as they are derived from multiple anatomical sources, from different tissues, human mesenchymal stem cells (hMSCs) are a heterogeneous population showing ambiguity in their in vitro behavior. Intra-clonal population heterogeneity has also been identified and pre-clinical mechanistic studies suggest that these cumulatively depreciate the therapeutic effects of hMSC transplantation. Although various biomarkers identify these specific stem cell populations, recent artificial intelligence-based methods have capitalized on the cellular morphologies of hMSCs, opening a new approach to understand their attributes. A robust and rapid platform is required to accommodate and eliminate the heterogeneity observed in the cell population, to standardize the quality of hMSC therapeutics globally. Here, we report our primary findings of morphological heterogeneity observed within and across two sources of hMSCs namely, stem cells from human exfoliated deciduous teeth (SHEDs) and human Wharton jelly mesenchymal stem cells (hWJ MSCs), using real-time single-cell images generated on immunophenotyping by imaging flow cytometry (IFC). We used the ImageJ software for identification and comparison between the two types of hMSCs using statistically significant morphometric descriptors that are biologically relevant. To expand on these insights, we have further applied deep learning methods and successfully report the development of a Convolutional Neural Network-based image classifier. In our research, we introduced a machine learning methodology to streamline the entire procedure, utilizing convolutional neural networks and transfer learning for binary classification, achieving an accuracy rate of 97.54%. We have also critically discussed the challenges, comparisons between solutions and future directions of machine learning in hMSC classification in biotherapeutics.


Asunto(s)
Aprendizaje Automático , Células Madre Mesenquimatosas , Análisis de la Célula Individual , Humanos , Células Madre Mesenquimatosas/citología , Análisis de la Célula Individual/métodos , Inmunofenotipificación/métodos , Citometría de Flujo/métodos , Diente Primario/citología , Procesamiento de Imagen Asistido por Computador/métodos , Gelatina de Wharton/citología , Células Cultivadas
2.
Crit Rev Clin Lab Sci ; 61(2): 107-126, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37776896

RESUMEN

Monoclonal gammopathy (MG) is a spectrum of diseases ranging from the benign asymptomatic monoclonal gammopathy of undetermined significance to the malignant multiple myeloma. Clinical guidelines and laboratory recommendations have been developed to inform best practices in the diagnosis, monitoring, and management of MG. In this review, the pathophysiology, relevant laboratory testing recommended in clinical practice guidelines and laboratory recommendations related to MG testing and reporting are examined. The clinical guidelines recommend serum protein electrophoresis, serum immunofixation and serum free light chain measurement as initial screening. The laboratory recommendations omit serum immunofixation as it offers limited additional diagnostic value. The laboratory recommendations offer guidance on reporting findings beyond monoclonal protein, which was not required by the clinical guidelines. The clinical guidelines suggested monitoring total IgA concentration by turbidimetry or nephelometry method if the monoclonal protein migrates in the non-gamma region, whereas the laboratory recommendations make allowance for involved IgM and IgG. Additionally, several external quality assurance programs for MG protein electrophoresis and free light chain testing are also appraised. The external quality assurance programs show varied assessment criteria for protein electrophoresis reporting and unit of measurement. There is also significant disparity in reported monoclonal protein concentrations with wide inter-method analytical variation noted for both monoclonal protein quantification and serum free light chain measurement, however this variation appears smaller when the same method was used. Greater harmonization among laboratory recommendations and reporting format may improve clinical interpretation of MG testing.


Asunto(s)
Gammopatía Monoclonal de Relevancia Indeterminada , Paraproteinemias , Humanos , Gammopatía Monoclonal de Relevancia Indeterminada/diagnóstico , Paraproteinemias/diagnóstico , Laboratorios , Cadenas Ligeras de Inmunoglobulina
3.
J Gen Virol ; 105(10)2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39422666

RESUMEN

Foot-and-mouth disease vaccination using inactivated virus is suboptimal, as the icosahedral viral capsids often disassemble into antigenically distinct pentameric units during long-term storage, or exposure to elevated temperature or lowered pH, and thus raise a response that is no longer protective. Furthermore, as foot-and-mouth disease virus (FMDV)'s seven serotypes are antigenically diverse, cross-protection from a single serotype vaccine is limited, and most existing mouse and bovine antibodies and camelid single-domain heavy chain-only antibodies are serotype-specific. For quality control purposes, there is a real need for pan-serotype antibodies that clearly distinguish between pentamer (12S) and protective intact FMDV capsid. To date, few cross-serotype bovine-derived antibodies have been reported in the literature. We identify a bovine antibody with an ultralong CDR-H3, Ab117, whose structural analysis reveals that it binds to a deep, hydrophobic pocket on the interior surface of the capsid via the CDR-H3. Main-chain and hydrophobic interactions provide broad serotype specificity. ELISA analysis confirms that Ab117 is a novel pan-serotype and conformational epitope-specific 12S reagent, suitable for assessing capsid integrity.


Asunto(s)
Anticuerpos Antivirales , Proteínas de la Cápside , Cápside , Virus de la Fiebre Aftosa , Virus de la Fiebre Aftosa/inmunología , Animales , Bovinos , Anticuerpos Antivirales/inmunología , Cápside/inmunología , Proteínas de la Cápside/inmunología , Fiebre Aftosa/inmunología , Fiebre Aftosa/virología , Serogrupo , Reacciones Cruzadas , Epítopos/inmunología
4.
Brief Bioinform ; 23(3)2022 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-35419584

RESUMEN

Gene Ontology (GO) is widely used in the biological domain. It is the most comprehensive ontology providing formal representation of gene functions (GO concepts) and relations between them. However, unintentional quality defects (e.g. missing or erroneous relations) in GO may exist due to the large size of GO concepts and complexity of GO structures. Such quality defects would impact the results of GO-based analyses and applications. In this work, we introduce a novel evidence-based lexical pattern approach for quality assurance of GO relations. We leverage two layers of evidence to suggest potentially missing relations in GO as follows. We first utilize related concept pairs (i.e. existing relations) in GO to extract relationship-specific lexical patterns, which serve as the first layer evidence to automatically suggest potentially missing relations between unrelated concept pairs. For each suggested missing relation, we further identify two other existing relations as the second layer of evidence that resemble the difference between the missing relation and the existing relation based on which the missing relation is suggested. Applied to the 15 December 2021 release of GO, this approach suggested a total of 866 potentially missing relations. Local domain experts evaluated the entire set of potentially missing relations, and identified 821 as missing relations and 45 indicate erroneous existing relations. We submitted these findings to the GO consortium for further validation and received encouraging feedback. These indicate that our evidence-based approach can be utilized to uncover missing relations and erroneous existing relations in GO.


Asunto(s)
Ontología de Genes
5.
Histochem Cell Biol ; 162(6): 541-550, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39317804

RESUMEN

The use of cold formalin fixation (CFF; i.e., fixating tissue samples with 4 °C precooled formalin) recently attracted further attention owing to its putative improved ability to preserve nucleic acid compared with standard room temperature formalin (SFF). In this study, we aimed to assess the effect of four formalin-based fixation protocols (SFF, CFF, delayed formalin fixation-DFF, and cold formalin hyperfixation; CFH) on both DNA and RNA quality. We collected 97 colorectal cancer (CRC) and analyzed 23 metrics of nucleic acid quantity and quality yield using a multiplatform approach by combining spectrophotometric, fluorimetric, electrophoretic, and polymerase chain reaction (PCR) assays. Following confirmation of fixation-protocol-related different effects via clustering analysis, CFF presented best metrics compared with all protocols, specifically positive coefficients of DV1000-60000, DV2/DV1, DNA λ ratio 260/230, and ABL gene expression absolute copies, and negative coefficient of DV150-1000. The SFF subgroup presented a positive coefficient of DV150-1000 and negative coefficients for DV1000-60000, DV2/DV1, RNA λ ratio 260/230, RNA QuBit concentration, DV100/200, RNA electrophoresis concentration and absolute quantity, and ABL copies. Overall, we confirmed the superior yield performances of CFF preservation for both DNA and RNA compared with the other protocols in our series of CRC samples. Pending further validations and clarification of the specific mechanisms behind these findings, our study supports the implementation of CFF in the pathology unit routine specimen management for tumor tissue molecular profiling.


Asunto(s)
Neoplasias Colorrectales , Formaldehído , Fijación del Tejido , Humanos , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/genética , Neoplasias Colorrectales/metabolismo , Neoplasias Colorrectales/diagnóstico , Formaldehído/química , ADN/análisis , ARN/análisis , Frío
6.
J Cardiovasc Electrophysiol ; 35(8): 1645-1655, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38924224

RESUMEN

INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Competencia Clínica , Educación de Postgrado en Medicina , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Curva de Aprendizaje , Técnicas Electrofisiológicas Cardíacas , Inteligencia Artificial , Factores de Tiempo , Resultado del Tratamiento , Becas , Cardiólogos/educación , Electrofisiología Cardíaca/educación , Catéteres Cardíacos
7.
Metabolomics ; 20(3): 49, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689195

RESUMEN

INTRODUCTION: Untargeted metabolomics studies are expected to cover a wide range of compound classes with high chemical diversity and complexity. Thus, optimizing (pre-)analytical parameters such as the analytical liquid chromatography (LC) column is crucial and the selection of the column depends primarily on the study purpose. OBJECTIVES: The current investigation aimed to compare six different analytical columns. First, by comparing the chromatographic resolution of selected compounds. Second, on the outcome of an untargeted toxicometabolomics study using pooled human liver microsomes (pHLM), rat plasma, and rat urine as matrices. METHODS: Separation and analysis were performed using three different reversed-phase (Phenyl-Hexyl, BEH C18, and Gold C18), two hydrophilic interaction chromatography (HILIC) (ammonium-sulfonic acid and sulfobetaine), and one porous graphitic carbon (PGC) columns coupled to high-resolution mass spectrometry (HRMS). Their impact was evaluated based on the column performance and the size of feature count, amongst others. RESULTS: All three reversed-phase columns showed a similar performance, whereas the PGC column was superior to both HILIC columns at least for polar compounds. Comparing the size of feature count across all datasets, most features were detected using the Phenyl-Hexyl or sulfobetaine column. Considering the matrices, most significant features were detected in urine and pHLM after using the sulfobetaine and in plasma after using the ammonium-sulfonic acid column. CONCLUSION: The results underline that the outcome of this untargeted toxicometabolomic study LC-HRMS metabolomic study was highly influenced by the analytical column, with the Phenyl-Hexyl or sulfobetaine column being the most suitable. However, column selection may also depend on the investigated compounds as well as on the investigated matrix.


Asunto(s)
Interacciones Hidrofóbicas e Hidrofílicas , Metabolómica , Microsomas Hepáticos , Ratas , Animales , Humanos , Metabolómica/métodos , Microsomas Hepáticos/metabolismo , Cromatografía de Fase Inversa/métodos , Grafito/química , Plasma/química , Plasma/metabolismo , Cromatografía Liquida/métodos , Porosidad , Metaboloma
8.
Metabolomics ; 20(2): 20, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38345679

RESUMEN

BACKGROUND: Quality assurance (QA) and quality control (QC) practices are key tenets that facilitate study and data quality across all applications of untargeted metabolomics. These important practices will strengthen this field and accelerate its success. The Best Practices Working Group (WG) within the Metabolomics Quality Assurance and Quality Control Consortium (mQACC) focuses on community use of QA/QC practices and protocols and aims to identify, catalogue, harmonize, and disseminate current best practices in untargeted metabolomics through community-driven activities. AIM OF REVIEW: A present goal of the Best Practices WG is to develop a working strategy, or roadmap, that guides the actions of practitioners and progress in the field. The framework in which mQACC operates promotes the harmonization and dissemination of current best QA/QC practice guidance and encourages widespread adoption of these essential QA/QC activities for liquid chromatography-mass spectrometry. KEY SCIENTIFIC CONCEPTS OF REVIEW: Community engagement and QA/QC information gathering activities have been occurring through conference workshops, virtual and in-person interactive forum discussions, and community surveys. Seven principal QC stages prioritized by internal discussions of the Best Practices WG have received participant input, feedback and discussion. We outline these stages, each involving a multitude of activities, as the framework for identifying QA/QC best practices. The ultimate planned product of these endeavors is a "living guidance" document of current QA/QC best practices for untargeted metabolomics that will grow and change with the evolution of the field.


Asunto(s)
Exactitud de los Datos , Metabolómica , Humanos , Metabolómica/métodos , Control de Calidad , Encuestas y Cuestionarios
9.
Metabolomics ; 20(4): 73, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38980450

RESUMEN

INTRODUCTION: During the Metabolomics 2023 conference, the Metabolomics Quality Assurance and Quality Control Consortium (mQACC) presented a QA/QC workshop for LC-MS-based untargeted metabolomics. OBJECTIVES: The Best Practices Working Group disseminated recent findings from community forums and discussed aspects to include in a living guidance document. METHODS: Presentations focused on reference materials, data quality review, metabolite identification/annotation and quality assurance. RESULTS: Live polling results and follow-up discussions offered a broad international perspective on QA/QC practices. CONCLUSIONS: Community input gathered from this workshop series is being used to shape the living guidance document, a continually evolving QA/QC best practices resource for metabolomics researchers.


Asunto(s)
Espectrometría de Masas , Metabolómica , Control de Calidad , Metabolómica/métodos , Metabolómica/normas , Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Espectrometría de Masas/métodos , Humanos , Consenso , Cromatografía Líquida con Espectrometría de Masas
10.
Eur J Nucl Med Mol Imaging ; 51(6): 1498-1505, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38319322

RESUMEN

BACKGROUND: In the rapidly evolving field of nuclear medicine, the paramount importance of radiation protection, safety, and quality systems cannot be overstated. This document provides a comprehensive analysis of the intricate regulatory frameworks and guidelines, meticulously crafted and updated by national and international regulatory bodies to ensure the utmost safety and efficiency in the practice of nuclear medicine. METHODS: We explore the dynamic nature of these regulations, emphasizing their adaptability in accommodating technological advancements and the integration of nuclear medicine with other medical and scientific disciplines. RESULTS: Audits, both internal and external, are spotlighted for their pivotal role in assessing and ensuring compliance with established standards, promoting a culture of continuous improvement and excellence. We delve into the significant contributions of entities like the International Atomic Energy Agency (IAEA) and relevant professional societies in offering universally applicable guidelines that amalgamate the latest in scientific research, ethical considerations, and practical applicability. CONCLUSIONS: The document underscores the essence of international collaborations in pooling expertise, resources, and insights, fostering a global community of practice where knowledge and innovations are shared. Readers will gain an in-depth understanding of the practical applications, challenges, and opportunities presented by these regulatory frameworks and audit processes. The ultimate goal is to inspire and inform ongoing efforts to enhance safety, quality, and effectiveness in nuclear medicine globally.


Asunto(s)
Medicina Nuclear , Protección Radiológica , Medicina Nuclear/normas , Protección Radiológica/normas , Humanos , Control de Calidad , Seguridad
11.
J Magn Reson Imaging ; 59(1): 325-336, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37141174

RESUMEN

BACKGROUND: There exist several fMRI quality assurance measures to assess scanner stability. Because they have practical and/or theoretical limitations, a different and more practical measure for instability would be desirable. PURPOSE: To develop and test a sensitive, reliable and widely applicable temporal instability measure (TIM) for fMRI quality assurance. STUDY TYPE: Technical development. PHANTOM: Spherical gel phantom. POPULATION: A total of 120 datasets from a local Philips scanner with two different receive-only head coils (32ch and 8ch, 60 datasets per coil) were collected as well as 29 additional datasets with three different receive-only head coils (20ch, 32ch, and 64ch) from two additional sites with GE (seven runs with 32ch) and Siemens scanners (seven runs with 32ch and Multiband imaging, five runs with 20ch, 32ch, and 64ch) were borrowed. FIELD STRENGTH/SEQUENCE: 2D Echo-planar-imaging (EPI). ASSESSMENT: A new TIM was proposed that is based on the eigenratio of the correlation coefficient matrix, where each entry of the matrix is a correlation coefficient between two time-points of the time-series. STATISTICAL TESTS: Nonparametric bootstrap resampling was used twice to estimate confidence intervals (CI) of the TIM values and to assess the improved sensitivity of this measure. Differences in coil performance were assessed via a nonparametric bootstrap two-sample t-test. P-values <0.05 were considered significant. RESULTS: The TIM values ranged between 60 parts-per-million and 10,780 parts-per-million across all 149 experiments. The mean CI was 2.96% and 2.16% for the 120 and 29 fMRI datasets, respectively (the repeated bootstrap analysis gave 2.9% and 2.19%, respectively). The 32ch coils of the local Philips data provided more stable measurements than the 8ch coil (observed two-sample t-values = 26.36, -0.2 and -6.2 for TIM, tSNR, and RDC, respectively. PtSNR = 0.58). DATA CONCLUSION: The proposed TIM is particularly useful for multichannel coils with spatially nonuniform receive sensitivity and overcomes several limitations of other measures. As such, it provides a reliable test for ascertaining scanner stability for fMRI experiments. EVIDENCE LEVEL: 5. TECHNICAL EFFICACY: Stage 1.


Asunto(s)
Imagen Eco-Planar , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados
12.
Virol J ; 21(1): 40, 2024 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-38341597

RESUMEN

Since the onset of the coronavirus disease (COVID-19) pandemic in Belgium, UZ/KU Leuven has played a crucial role as the National Reference Centre (NRC) for respiratory pathogens, to be the first Belgian laboratory to develop and implement laboratory developed diagnostic assays for SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) and later to assess the quality of commercial kits. To meet the growing demand for decentralised testing, both clinical laboratories and government-supported high-throughput platforms were gradually deployed across Belgium. Consequently, the role of the NRC transitioned from a specialised testing laboratory to strengthening capacity and coordinating quality assurance. Here, we outline the measures taken by the NRC, the national public health institute Sciensano and the executing clinical laboratories to ensure effective quality management of molecular testing throughout the initial two years of the pandemic (March 2020 to March 2022).


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiología , Bélgica/epidemiología , Prueba de COVID-19 , Pandemias , Técnicas de Laboratorio Clínico , Técnicas de Diagnóstico Molecular
13.
Reprod Biomed Online ; 48(5): 103777, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38460281

RESUMEN

RESEARCH QUESTION: Does the choice of sperm-counting chamber affect the proportion of samples generating results with an erroneous interpretation? DESIGN: Laboratories in an external quality assurance programme were sent 141 semen samples over a 12-year period and asked to return the sperm concentration and whether or not the result was abnormal. Only those using 5th edition of the World Health Organization manual (WHO5) interpretation criteria were included. Submissions from specialist fertility laboratories were used to calculate assigned values for each sample. Laboratory50 values determined the sperm concentration at which the laboratories reported a majority transition from abnormal to normal interpretations, i.e. the tipping point, which should coincide with the lower reference limit. RESULTS: The median and range of bias from the assigned values of each sample were determined for the Makler (-3.3%; -88.6% to +332.8%), haemocytometer (10.6%; -93.3% to +645.5%), Kova (+65.3%; -71.7% to +581.8%) and Vetriplast (+72.4%; -100.0% to +709.1) chambers. Laboratory50 values for the Makler (17.3  ×  106/ml), haemocytometer (13.6  ×  106/ml), Kova (10.0  ×  106/ml) and Vetriplast chambers (8.8  ×  106/ml) reflected the under- and overestimation of the chambers and confirmed a shift in the adjusted lower reference limit then used. The proportion of laboratories reporting erroneous interpretations of the four chambers for oligozoospermic samples were 10.9%, 15.1.%, 40.1% and 44.0%, respectively, and rose as the adjusted lower reference limit decreased. CONCLUSIONS: The between-laboratory and within-sample variation for all the chambers was high and remains a concern. The main impact of an increasing bias of the chambers was a lowering of the laboratory50 tipping point, resulting in an under-reporting of abnormal semen samples.


Asunto(s)
Análisis de Semen , Recuento de Espermatozoides , Humanos , Masculino , Recuento de Espermatozoides/instrumentación , Recuento de Espermatozoides/métodos , Análisis de Semen/métodos , Análisis de Semen/instrumentación , Análisis de Semen/normas , Espermatozoides
14.
World J Urol ; 42(1): 236, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619659

RESUMEN

PURPOSE: We evaluate differences of patient-reported outcome measurements (PROM) based urinary continence and sexual function 12 months after radical prostatectomy (RPE) based on perioperative, surgical, and patient-specific characteristics in a large European academic urology center. MATERIALS AND METHODS: All men enrolled in the Prostate Cancer Outcome Study (PCO) study who were treated with RPE between 2017 and 2021 completed EPIC-26 information surveys before and 12 months after RPE. Survey data were linked to clinical data of our institution. Logistic regression analyses were performed to examine the correlation between individual surgeons, patient characteristics, patient clinical data, and their urinary continence and sexual function. RESULTS: In total, data of 429 men were analyzed: unstratified mean (SD) EPIC-26 domain score for urinary function decreased from 93.3 (0.7) to 60.4 (1.5) one year after RPE, respectively for sexual function from 64.95 (1.6) to 23.24 (1.1). Patients with preoperative adequate urinary function (EPIC-26 score > 80) reported significantly different mean urinary function scores between 53.35 (28.88) and 66.25 (25.15), p= 0.001, stratified by surgeons experience. On binary logistic regression analyses, only nerve sparing techniques (OR: 1,83, 95% CI: 1.01;3.21; p = 0.045) and low body mass index (OR: 0.91, CI: 0.85;0.99, p= 0.032) predicted adequate postoperative urinary function. CONCLUSIONS: The results show how using provider-specific data from a larger cohort study enables to develop institution-specific analysis for functional outcomes after RPE. These models can be used for internal quality improvement as well as enhanced and provider-specific patient communication and shared decision making.


Asunto(s)
Neoplasias de la Próstata , Mejoramiento de la Calidad , Masculino , Humanos , Estudios de Cohortes , Prostatectomía , Medición de Resultados Informados por el Paciente , Neoplasias de la Próstata/cirugía
15.
Eur Radiol ; 34(9): 5876-5885, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38466390

RESUMEN

OBJECTIVES: To evaluate an artificial intelligence (AI)-assisted double reading system for detecting clinically relevant missed findings on routinely reported chest radiographs. METHODS: A retrospective study was performed in two institutions, a secondary care hospital and tertiary referral oncology centre. Commercially available AI software performed a comparative analysis of chest radiographs and radiologists' authorised reports using a deep learning and natural language processing algorithm, respectively. The AI-detected discrepant findings between images and reports were assessed for clinical relevance by an external radiologist, as part of the commercial service provided by the AI vendor. The selected missed findings were subsequently returned to the institution's radiologist for final review. RESULTS: In total, 25,104 chest radiographs of 21,039 patients (mean age 61.1 years ± 16.2 [SD]; 10,436 men) were included. The AI software detected discrepancies between imaging and reports in 21.1% (5289 of 25,104). After review by the external radiologist, 0.9% (47 of 5289) of cases were deemed to contain clinically relevant missed findings. The institution's radiologists confirmed 35 of 47 missed findings (74.5%) as clinically relevant (0.1% of all cases). Missed findings consisted of lung nodules (71.4%, 25 of 35), pneumothoraces (17.1%, 6 of 35) and consolidations (11.4%, 4 of 35). CONCLUSION: The AI-assisted double reading system was able to identify missed findings on chest radiographs after report authorisation. The approach required an external radiologist to review the AI-detected discrepancies. The number of clinically relevant missed findings by radiologists was very low. CLINICAL RELEVANCE STATEMENT: The AI-assisted double reader workflow was shown to detect diagnostic errors and could be applied as a quality assurance tool. Although clinically relevant missed findings were rare, there is potential impact given the common use of chest radiography. KEY POINTS: • A commercially available double reading system supported by artificial intelligence was evaluated to detect reporting errors in chest radiographs (n=25,104) from two institutions. • Clinically relevant missed findings were found in 0.1% of chest radiographs and consisted of unreported lung nodules, pneumothoraces and consolidations. • Applying AI software as a secondary reader after report authorisation can assist in reducing diagnostic errors without interrupting the radiologist's reading workflow. However, the number of AI-detected discrepancies was considerable and required review by a radiologist to assess their relevance.


Asunto(s)
Inteligencia Artificial , Radiografía Torácica , Humanos , Radiografía Torácica/métodos , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Femenino , Errores Diagnósticos/prevención & control , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Aprendizaje Profundo , Procesamiento de Lenguaje Natural , Algoritmos , Anciano
16.
Infection ; 52(2): 413-427, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37684496

RESUMEN

PURPOSE: Timely and accurate data on the epidemiology of sepsis are essential to inform policy decisions and research priorities. We aimed to investigate the validity of inpatient administrative health data (IAHD) for surveillance and quality assurance of sepsis care. METHODS: We conducted a retrospective validation study in a disproportional stratified random sample of 10,334 inpatient cases of age ≥ 15 years treated in 2015-2017 in ten German hospitals. The accuracy of coding of sepsis and risk factors for mortality in IAHD was assessed compared to reference standard diagnoses obtained by a chart review. Hospital-level risk-adjusted mortality of sepsis as calculated from IAHD information was compared to mortality calculated from chart review information. RESULTS: ICD-coding of sepsis in IAHD showed high positive predictive value (76.9-85.7% depending on sepsis definition), but low sensitivity (26.8-38%), which led to an underestimation of sepsis incidence (1.4% vs. 3.3% for severe sepsis-1). Not naming sepsis in the chart was strongly associated with under-coding of sepsis. The frequency of correctly naming sepsis and ICD-coding of sepsis varied strongly between hospitals (range of sensitivity of naming: 29-71.7%, of ICD-diagnosis: 10.7-58.5%). Risk-adjusted mortality of sepsis per hospital calculated from coding in IAHD showed no substantial correlation to reference standard risk-adjusted mortality (r = 0.09). CONCLUSION: Due to the under-coding of sepsis in IAHD, previous epidemiological studies underestimated the burden of sepsis in Germany. There is a large variability between hospitals in accuracy of diagnosing and coding of sepsis. Therefore, IAHD alone is not suited to assess quality of sepsis care.


Asunto(s)
Hospitales , Sepsis , Humanos , Adolescente , Estudios Retrospectivos , Mortalidad Hospitalaria , Sepsis/diagnóstico , Sepsis/epidemiología , Sesgo
17.
Pediatr Blood Cancer ; 71(3): e30766, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37950538

RESUMEN

Surgery plays a crucial role in the treatment of children with solid malignancies. A well-conducted operation is often essential for cure. Collaboration with the primary care team is important for determining if and when surgery should be performed, and if performed, an operation must be done in accordance with well-established standards. The long-term consequences of surgery also need to be considered. Indications and objectives for a procedure vary. Providing education and developing and analyzing new research protocols that include aims relevant to surgery are key objectives of the Surgery Discipline of the Children's Oncology Group. The critical evaluation of emerging technologies to ensure safe, effective procedures is another key objective. Through research, education, and advancing technologies, the role of the pediatric surgeon in the multidisciplinary care of children with solid malignancies will continue to evolve.


Asunto(s)
Neoplasias , Niño , Humanos , Neoplasias/cirugía , Oncología Médica
18.
Scand J Gastroenterol ; 59(11): 1234-1239, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39350740

RESUMEN

BACKGROUND: Fecal Microbiota Transplant (FMT) is an effective treatment for recurring Clostridioides Difficile Infections (rCDI). FMT administered via oral capsules (caFMT) offers several practical advantages to conventional liquid FMT. We began using caFMT in 2021 imported from an external institution. Based on similar production methods, we began our own caFMT production in 2022. We aimed to evaluate the quality of our caFMT. STUDY DESIGN AND METHODS: We created a database of all FMT treatments (n = 180) provided by our institution. Quality of all FMT was evaluated by treatment success rates. We compared our caFMT to the imported caFMT. RESULTS: Our caFMT yielded similar success rates compared to that of the imported caFMT, 65% (CI 95% 58-72%) and 72% (CI 95% 66-79%) respectively. FMT administered via colonoscopy had a significantly higher success rate, 79% (CI 95% 73-85%) than own our caFMT and other routes of administration. The combined success rate of treatments increased notably for all routes of administration when repeating FMT after prior failure. DISCUSSION: The fact that our caFMT compared similarly to the imported caFMT was viewed as a success in terms of quality assurance. Our caFMT had a slightly lower success rates compared to data from other studies, but could be affected by several other factors than our FMT-production methods. A lower success rate of caFMT compared to FMT via colonoscopy is acceptable due to the practical advantages offed by caFMT. Our study serves as a practical example, proving that of the standardization of caFMT production is indeed viable.


Asunto(s)
Infecciones por Clostridium , Trasplante de Microbiota Fecal , Humanos , Infecciones por Clostridium/terapia , Femenino , Masculino , Persona de Mediana Edad , Cápsulas , Anciano , Garantía de la Calidad de Atención de Salud , Colonoscopía , Resultado del Tratamiento , Clostridioides difficile , Heces/microbiología , Adulto , Anciano de 80 o más Años , Administración Oral
19.
Gastric Cancer ; 27(4): 876-883, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38761290

RESUMEN

BACKGROUND: Despite its recognized importance, there is currently no reliable tool for surgical quality assurance (SQA) of gastrectomy in surgical oncology. The aim of this study was to develop an SQA tool for gastrectomy and to apply this tool within the ADDICT Trial in order to assess the extent and completeness of lymphadenectomy. METHODS: The operative steps for D1+ and D2 gastrectomy have been previously described in the literature and ADDICT trial manual. Two researchers also performed fieldwork in the UK and Japan to document key operative steps through photographs and semi-structured interviews with expert surgeons. This provided the steps that were used as the framework for the SQA tool. Sixty-two photographic cases from the ADDICT Trial were rated by three independent surgeons. Generalizability (G) theory determined inter-rater reliability. D-studies examined the effect of varying the number of assessors and photographic series they rated. Chi-square assessed intra-rater reliability, comparing how the individual assessor's responses corresponded to their global rating for extent of lymphadenectomy. RESULTS: The tool comprised 20 items, including 19 anatomical landmarks and a global rating score. Overall reliability had G-coefficient of 0.557. Internal consistency was measured with a Cronbach's alpha score of 0.869 and Chi-square confirmed intra-rater reliability for each assessor as < 0.05. CONCLUSIONS: A photographic surgical quality assurance tool is presented for gastrectomy. Using this tool, the assessor can reliably determine not only the quality but also the extent of the lymphadenectomy performed based on remaining anatomy rather than the excised specimen.


Asunto(s)
Gastrectomía , Escisión del Ganglio Linfático , Garantía de la Calidad de Atención de Salud , Neoplasias Gástricas , Gastrectomía/normas , Gastrectomía/métodos , Humanos , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Garantía de la Calidad de Atención de Salud/normas , Escisión del Ganglio Linfático/normas , Escisión del Ganglio Linfático/métodos , Reproducibilidad de los Resultados
20.
BMC Infect Dis ; 24(Suppl 1): 194, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38418989

RESUMEN

BACKGROUND: Sexually transmitted infections (STIs) such as syphilis and HIV remain to be a significant public health issue worldwide. Dual rapid point-of-care tests (POCTs) have shown promise for detecting antibodies to HIV and syphilis but have not been fully evaluated in the field. Our study supported the WHO ProSPeRo study on Sexually Transmitted Infection Point-of-Care Testing (STI POCT) by providing external quality assessment (EQA) for HIV and syphilis testing in reference laboratories and their associated clinical sites in seven countries. METHODS: HIV/syphilis serum liquid and dried tube specimen (DTS) panels were prepared by CDC. Liquid panels were distributed to the reference laboratories for three rounds of testing using commercially and locally available laboratory-based serological tests. DTS panels were sent to the clinical testing sites for 8 rounds of POC testing using the Abbott SD BIOLINE HIV/Syphilis Duo test (hereafter referred to as SD BIOLINE) and the Chembio Dual Path Platform (DPP) HIV-Syphilis assay. EQA panels were tested at CDC using the Rapid Plasma Reagin (RPR) test and the Treponema pallidum Particle Agglutination assay (TP-PA) for syphilis antibodies. Genetic Systems HIV-1/HIV-2 Plus O EIA, Geenius HIV Supplemental Assay and the Oraquick Advance HIV test were used to detect HIV antibodies in the EQA panels. Results from the reference laboratories and POCT sites were compared to those obtained at the CDC and a percentage agreement was calculated. RESULTS: Qualitative RPR and TP-PA performed at the reference laboratories demonstrated 95.4-100% agreement with CDC results while quantitative RPR and TP-PA tests demonstrated 87.7% and 89.2% agreement, respectively. A 93.8% concordance rate was observed for qualitative HIV testing in laboratories. EQA testing at clinical sites using dual tests showed 98.7% and 99.1% agreement for detection of HIV antibodies and eight out of 10 sites had > 95.8% agreement for syphilis testing. However, two clinical sites showed only 65.0-66.7% agreement for SD BIOLINE and 84.0-86.7% for DPP, respectively, for syphilis testing. CONCLUSIONS: Overall, laboratories demonstrated high EQA performance in this study. Both HIV/syphilis POCTs gave expected results in the clinic-based evaluations using DTS. However, testing errors were identified in a few testing sites suggesting the necessity for continuous training and monitoring the quality of POC testing.


Asunto(s)
Infecciones por VIH , VIH-1 , Sífilis , Humanos , Treponema pallidum , Anticuerpos Anti-VIH , Infecciones por VIH/diagnóstico , Sensibilidad y Especificidad , Anticuerpos Antibacterianos , Pruebas en el Punto de Atención , Serodiagnóstico de la Sífilis/métodos , VIH-2 , Organización Mundial de la Salud , Sistemas de Atención de Punto
SELECCIÓN DE REFERENCIAS
Detalles de la búsqueda